Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Current-driven vortex domain wall motion in wire-tube nanostructures

We have investigated the current-driven domain wall motion in nanostructures comprised of a pair of nanotube and nanowire segments. Under certain values of external magnetic fields, it is possible to pin a vortex domain wall in the transition zone between the wire and tube segments. We explored the behavior of this domain wall under the action of an electron flow applied in the opposite direction to the magnetic field. Thus, for a fixed magnetic field, it is possible to release a domain wall pinned simply by increasing the intensity of the current density, or conversely, for a fixed current density, it is possible to release the domain wall simply decreasing the magnetic external field. When the domain wall remains pinned due to the competition between the current density and the magnetic external field, it exhibits a oscillation frequency close to 8 GHz. The amplitude of the oscillations increases with the current density and decreases over time. On the other hand, when the domain wall is released and propagated through the tube segment, this shows the standard separation between a steady and a precessional regime. The ability to pin and release a domain wall by varying the geometric parameters, the current density, or the magnetic field transforms these wire-tube nanostructures in an interesting alternative as an on/off switch nano-transistor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-87: Lung Deformable Image Registration Using Surface Mesh Deformation for Dose Distribution Combination

Purpose: To allow a reliable deformable image registration (DIR) method for dose calculation in radiation therapy. This work proposes a performance assessment of a morphological segmentation algorithm that generates a deformation field from lung surface displacements with 4DCT datasets. Methods: From the 4DCT scans of 15 selected patients, the deep exhale phase of the breathing cycle is identified as the reference scan. Varian TPS EclipseTM is used to draw lung contours, which are given as input to the morphological segmentation algorithm. Voxelized contours are smoothed by a Gaussian filter and then transformed into a surface mesh representation. Such mesh is adapted by rigid and elastic deformations to match each subsequent lung volumes. The segmentation efficiency is assessed by comparing the segmented lung contour and the TPS contour considering two volume metrics, defined as Volumetric Overlap Error (VOE) [%] and Relative Volume Difference (RVD) [%] and three surface metrics, defined as Average Symmetric Surface Distance (ASSD) [mm], Root Mean Square Symmetric Surface Distance (RMSSD) [mm] and Maximum Symmetric Surface Distance (MSSD) [mm]. Then, the surface deformation between two breathing phases is determined by the displacement of corresponding vertices in each deformed surface. The lung surface deformation is linearly propagated in the lung volume to generate 3D deformation fields for each breathing phase. Results: The metrics were averaged over the 15 patients and calculated with the same segmentation parameters. The volume metrics obtained are a VOE of 5.2% and a RVD of 2.6%. The surface metrics computed are an ASSD of 0.5 mm, a RMSSD of 0.8 mm and a MSSD of 6.9 mm. Conclusion: This study shows that the morphological segmentation algorithm can provide an automatic method to capture an organ motion from 4DCT scans and translate it into a volume deformation grid needed by DIR method for dose distribution combination.

60 APPLIED LIFE SCIENCES↗

Microcomputer based software for biodynamic simulation

This paper presents a description of a microcomputer based software package, called DYNAMAN, which has been developed to allow an analyst to simulate the dynamics of a system consisting of a number of mass segments linked by joints. One primary application is in predicting the motion of a human occupant in a vehicle under the influence of a variety of external forces, specially those generated during a crash event. Extensive use of a graphical user interface has been made to aid the user in setting up the input data for the simulation and in viewing the results from the simulation. Among its many applications, it has been successfully used in the prototype design of a moving seat that aids in occupant protection during a crash, by aircraft designers in evaluating occupant injury in airplane crashes, and by users in accident reconstruction for reconstructing the motion of the occupant and correlating the impacts with observed injuries.

Rangarajan, N.↗

Gravitational Wave Sources as Timing References for LISA Data

In the megahertz gravitational-wave band, galactic ultra-compact binaries (UCBs) are continuous sources emitting at near-constant frequency. The signals from many of these galactic binaries will be sufficiently strong to be detectable by the Laser Interferometer Space Antenna (LISA) after approximately Omicron (1 week) of observing. In addition to their astrophysical value, these UCBs can be used to monitor the data quality of the observatory. This paper demonstrates the capabilities of galactic UCBs to be used as calibration sources for LISA by demanding signal coherence between adjacent week-long data segments separated by a gap in time of a priori unknown duration. A parameter for the gap duration is added to the UCB waveform model and used in a Markov-chain Monte Carlo algorithm simultaneously fitting for the astrophysical source parameters. Results from measurements of several UCBs are combined to produce a joint posterior on the gap duration. The measurement accuracy's dependence on how much is known about the UCBs through prior observing, and seasonal variations due to the LISA orbital motion, is quantified. The duration of data gaps in a two-week segment of data can be constrained to within approximately 0.2 s using Omicron (10) UCBs after one month of observing. The timing accuracy from UCBs improves to approximately or less than o.1 s after 1 year of mission operations. These results are robust to within a factor of approximately 2 when taking into account seasonal variations.

Gravitation Wave Sources↗

SU-E-J-20: Adaptive Aperture Morphing for Online Correction for Prostate Cancer Radiotherapy

Purpose: Online adaptive aperture morphing is desirable over translational couch shifts to accommodate not only the target position variation but also anatomic changes (rotation, deformation, and relation of target to organ-atrisks). We proposed quick and reliable method for adapting segment aperture leaves for IMRT treatment of prostate. Methods: The proposed method consists of following steps: (1) delineate the contours of prostate, SV, bladder and rectum on kV-CBCT; (2) determine prostate displacement from the rigid body registration of the contoured prostate manifested on the reference CT and the CBCT; (3) adapt the MLC segment apertures obtained from the pre-treatment IMRT planning to accommodate the shifts as well as anatomic changes. The MLC aperture adaptive algorithm involves two steps; first move the whole aperture according to prostate translational/rotational shifts, and secondly fine-tune the aperture shape to maintain the spatial relationship between the planning target contour and the MLC aperture to the daily target contour. Feasibility of this method was evaluated retrospectively on a seven-field IMRT treatment of prostate cancer patient by comparing dose volume histograms of the original plan and the aperture-adjusted plan, with/without additional segments weight optimization (SWO), on two daily treatment CBCTs selected with relative large motion and rotation. Results: For first daily treatment, the prostate rotation was significant (12degree around lateral-axis). With apertureadjusted plan, the D95 to the target was improved 25% and rectum dose (D30, D40) was reduced 20% relative to original plan on daily volumes. For second treatment-fraction, (lateral shift = 6.7mm), after adjustment target D95 improved by 3% and bladder dose (D30, maximum dose) was reduced by 1%. For both cases, extra SWO did not provide significant improvement. Conclusion: The proposed method of adapting segment apertures is promising in treatment position correction, including target translational displacement, rotation and deformation. Additional SWO could improve ROIs dose distribution.

60 APPLIED LIFE SCIENCES↗

SU-F-303-17: Real Time Dose Calculation of MRI Guided Co-60 Radiotherapy Treatments On Free Breathing Patients, Using a Motion Model and Fast Monte Carlo Dose Calculation

Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment were generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments.

60 APPLIED LIFE SCIENCES↗

Toward an IMU-based Space Suit Motion Capture System

Spacesuits are complex engineering systems that sustain human health and enable performance outside of Earth-like environments. These systems must support human mobility and physical workload demands while minimizing injury risk during extravehicular activity (EVA). Future EVA on the lunar surface during the Artemis program is expected to be more frequent and require higher physical workloads than previous EVAs during the ISS, Shuttle, or Apollo programs. Hence it is important to optimize future as well as current spacesuits to be efficient and comfortable for the success of space and planetary missions. To enable this, an efficient method is needed to test these spacesuits on the ground.When testing spacesuits in ground environments, it is often necessary to understand the kinematics of the suit to validate the design against relevant requirements or characterize the physical workload necessary to operate the suit. This is a challenging task for traditional optical motion capture (OMC) approaches: suit-mounted OMC markers are easily occluded by the subject or environment and may become detached during testing. Controlling lighting and reflectivity of objects in the motion capture volume is also difficult. Fixed-position OMC cameras also constrain testing to a small and contrived laboratory environment, disallowing kinematics capture in field environments.One promising alternative is the use of suit-mounted inertial measurement units (IMUs). These sensors are small, unobtrusive, and portable, but come at the cost of increased sensor noise and complexity of the software and mathematics to analyze the collected data. To this end, engineers at NASA are developing the Augmented Suit Inverse Kinematics (ASIK) system, a complete motion capture methodand inverse kinematics solver which relies solely on a network of wireless IMUs attached to the major kinematic segments of the spacesuit. The ASIK modeling language allows for the simple inclusion of probabilistic priors such as suit size and shape or IMU positions and rotations. Furthermore, to increase accuracy and reduce operational overhead to use this motion capture approach, the developed inverse kinematics solver exploits so-called self-calibratingalgorithmic techniques, which reduce the need for precise alignment of the sensors on the segments or scripted functional calibration procedures. The ASIK system was tested in a 7-subject pilot study. Each subject donned NASA’s new prototype exploration spacesuit in the Active Response Gravity Offload System (ARGOS) facility at the NASA Johnson Space Center. The subjects were outfitted with a set of 14 APDM (Portland, OR, USA) Opal IMUs, 12 of which were used in the ASIK model to estimate lower body and trunk kinematics. The subjects were also outfitted with a set of reflective OMC markers and traditional OMC data was collected and processed. Presented results will include characterization of ASIK-derived suit joint angles accuracy against an optical motion capture datum. Discussion of these results, as well as discussion of system calibration and nuances of mathematical observability, will be included.If successful, IMU-based motion capture will enable testing and validation of spacesuits more frequently, with less overhead, in more extreme environments. Future work will apply these techniques to common spacesuit testing tasks, such as gait, mobility, and balance assessment, physical workload characterization, and ergonomics evaluations.

Timothy Mcgrath↗

Magnetic suspension and pointing system

Apparatus for providing accurate pointing of instruments on a carrier vehicle and for providing isolation of the instruments from the vehicle's motion disturbances is presented. The apparatus includes two assemblies, with connecting interfaces, each assembly having a separate function. The first assembly is attached to the carrier vehicle and consists of an azimuth gimbal and an elevation gimbal which provide coarse pointing of the instruments by allowing two rotations of the instruments relative to the carrier vehicle. The second or vernier pointing assembly is made up of magnetic suspension and fine pointing actuators, roll motor segments, and an instrument mounting plate around which a continuous annular rim is attached which provides appropriate magnetic circuits for the actuators and the roll motor segments. The vernier pointing assembly provides six degree-of-freedom isolation from carrier motion disturbances.

Anderson, W. W.↗

Extracting collective motions underlying nucleosome dynamics via nonlinear manifold learning

The identification of effective collective variables remains a challenge in molecular simulations of complex systems. Here, we use a nonlinear manifold learning technique known as the diffusion map to extract key dynamical motions from a complex biomolecular system known as the nucleosome: a DNA-protein complex consisting of a DNA segment wrapped around a disc-shaped group of eight histone proteins. We show that without any a priori information, diffusion maps can identify and extract meaningful collective variables that characterize the motion of the nucleosome complex. We find excellent agreement between the collective variables identified by the diffusion map and those obtained manually using a free energy-based analysis. Notably, diffusion maps are shown to also identify subtle features of nucleosome dynamics that did not appear in those manually specified collective variables. For example, diffusion maps identify the importance of looped conformations in which DNA bulges away from the histone complex that are important for the motion of DNA around the nucleosome. As a result, this work demonstrates that diffusion maps can be a promising tool for analyzing very large molecular systems and for identifying their characteristic slow modes.

36 MATERIALS SCIENCE↗

An adaptive algorithm for motion compensated color image coding

This paper presents an adaptive algorithm for motion compensated color image coding. The algorithm can be used for video teleconferencing or broadcast signals. Activity segmentation is used to reduce the bit rate and a variable stage search is conducted to save computations. The adaptive algorithm is compared with the nonadaptive algorithm and it is shown that with approximately 60 percent savings in computing the motion vector and 33 percent additional compression, the performance of the adaptive algorithm is similar to the nonadaptive algorithm. The adaptive algorithm results also show improvement of up to 1 bit/pel over interframe DPCM coding with nonuniform quantization. The test pictures used for this study were recorded directly from broadcast video in color.

Kwatra, Subhash C.↗

A coupled vacancy diffusion-dislocation dynamics model for the climb-glide motion of jogged screw dislocations

Here, we develop a novel model to study the climb/glide motion of jogged screw dislocations within the discrete dislocation dynamics (DDD) framework. We present results for the dependence of the climb velocity on the applied stress and on the jog size and distribution statistics. We show that the model predictions are consistent with experimental data in both γ-TiAl and Zircaloy-4. The ranges of the applied stress and jog spacing that determine the dominance of one of three dislocation mechanisms are identified. These are the jog dragging, dipole dragging, and dipole bypass mechanisms, respectively. The overall dislocation motion in the jog dragging regime is composed of glide of screw segments and climb of jogs, controlling the plastic strain and the creep rate, respectively. Based on current simulations and on a detailed examination of the predicted jog heights compared to experiments, we advance the hypothesis that a combination of jog dragging and dipole bypass mechanisms is necessary to reproduce the high creep rate observed in some experiments.

36 MATERIALS SCIENCE↗

Ergonomics - Using Ergonomics to Enhance Safe Production at a Surface Coal Mine - A Case Study with Powder Crews

Job tasks that involve exposure to work-related musculoskeletal disorder (WMSD) risk factors may impact both the risk of injury and production downtime. Common WMSD risks factors associated with mining tasks include forceful exertions, awkward postures, repetitive motion, jolting and jarring, forceful gripping, contact stress, and whole body and segmental vibration. Mining environments that expose workers to temperature/humidity extremes, windy conditions, and slippery and uneven walking surfaces also contribute to injury risk. National Institute for Occupational Safety and Health (NIOSH) researchers worked with powder crew members from the Bridger Coal Company to identify and rank routine work tasks based on perceived exposure to WMSD risk factors. This article presents the process followed to identify tasks that workers believed involved the greatest exposure to risk factors and discusses risk reduction strategies. Specifically, the proposed prill truck design changes addressed cab ingress/egress, loading blast holes, and access to the upper deck of the prill truck.

01 COAL, LIGNITE, AND PEAT↗

Ion Transport in Concentrated Crosslinked Solid Polymer Electrolytes

Crosslinking polymers is a common approach to create mechanically stable solid materials such as polymer electrolytes for lithium batteries. In conventional liquid electrolytes, the solvent molecules move freely to accommodate the field-induced motion of ions. However, in crosslinked polymer electrolytes, the rearrangement of polymer segments is constrained by the deformation limits of the network. Herein, we develop a new transport model that accounts for both the formation of concentration gradients and the elasticity of the electrolyte. The elasticity is incorporated by adding an additional term related to the entropy of crosslinked strands to the electrochemical potential of the salt. The resulting Crosslink Model contains two adjustable parameters: $\mathcal{N}$, the average number of monomers in a strand, and λ crit , the maximum strain the network can sustain. These solid-like constraints produce singularities in the governing transport equations, fundamentally altering the concentration profiles. Plateaus in salt concentrations emerge near the electrodes, and network elasticity introduces a strain overpotential. When compared to a Baseline Model ($\mathcal{N}$ → ∞, equivalent to concentrated solution theory), which predicts steepest gradients near the electrodes, both models yield similar current–voltage relationships. Model predictions are compared to electrochemical data for a poly(ethylene oxide)-based crosslinked polymer electrolyte.

Patel, Vivaan [University of California, Berkeley,↗

Follow-the-leader algorithm for the payload inspection and processing system

This report summarizes the author's summer 1995 work at NASA Kennedy Space Center in the Advanced System Division. The assignment was path planning for the Payload Inspection and Processing System (PIPS). PIPS is an automated system, programmed off-line for inspection of Space Shuttle payloads after integration and prior to launch. PIPS features a hyper-redundant 18-dof serpentine truss manipulator capable of snake-like motions to avoid obstacles. The path planning problem was divided into two segments: (1) determining an obstacle-free trajectory for the inspection camera at the manipulator tip to follow; and (2) development of a follow-the-leader (FTL) algorithm which ensures whole-arm collision avoidance by forcing ensuing links to follow the same tip trajectory. The summer 1995 work focused on the FTL algorithm. This report summarizes development, implementation, testing, and graphical demonstration of the FTL algorithm for prototype PIPS hardware. The method and code was developed in a modular manner so the final PIPS hardware may use them with minimal changes. The FTL algorithm was implemented using MATLAB software and demonstrated with a high-fidelity IGRIP model. The author also supported implementation of the algorithm in C++ for hardware control. The FTL algorithm proved to be successful and robust in graphical simulation. The author intends to return to the project in summer 1996 to implement path planning for PIPS.

Williams, Robert L., II↗

Speed Discrimination: Multiple Stimuli Appear Better Than One

We reported that for a 21FC task with multiple moving grating patches (Gabors) in each interval, thresholds for speed discrimination decreased with the number of patches, while increasing the area of a single grating produced no such effect. Furthermore, this decrease occurred regardless of the spacing of the patches about a circle of eccentricity 4 degrees, i.e., whether they were maximally separated or almost touching. These results suggest that it is the multiple, discrete grating patches that cause thresholds to decrease, rather than the spatial arrangement. To test this hypothesis, we measured the effect of dividing a large grating into four quadrants, by superimposing a mean-luminance cross on it. The mean speed discrimination thresholds (Weber Fractions) for four observers were 19, 15, and 11 plus or minus 2%, for the single large grating, the grating with cross, and the 4 maximally-separated, small gratings, respectively. Thus, breaking up a single large grating into multiple parts caused thresholds to improve, despite the fact that less of the original patch was visible. To investigate the possible contribution of total bounding contour length, we measured the effect of coalescing three small grating patches into a single banana-shaped patch, while keeping the total contour length constant. These two conditions were compared to a single, circular Gabor patch of equivalent area that had (necessarily) a smaller contour length. Preliminary data from 3 of 4 observers were similar for the small-grating and banana configurations, but increased for the single, large grating, suggesting that contour length might play a role. We are also investigating the role of low-level factors pertinent to the large grating, such as the pooling of signals from motion units at different eccentricities, and the stimulation of extended inhibitory motion surrounds, as well as the possible contribution of topdown influences that segment the stimulus into distinct objects.

Verghese, Preeti↗

pH Responsiveness of Polyelectrolyte Dendrimers: A Dynamical Perspective

Quasielastic neutron scattering (QENS) experiments were carried out to investigate the internal dynamics of aqueous (D2O) G5 PAMAM dendrimer solutions as a function of molecular protonation at room temperature. The localized motion was clearly exhibited in data analysis by being separated from the global translational diffusion. Our results unambiguously point out that with the molecular charge increased continuously the local motion is stably enhanced. The charge-induced local dynamics of dendrimer segments may correspond to their interaction with the surrounding counterions and water molecules. The outcome may provide significant information for the application of dendrimer-based packages as drug delivery vehicles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗