Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muscle Contraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

224 records · Page 13

Simulated microgravity upregulates an endothelial vasoconstrictor prostaglandin

Endothelial nitric oxide contributes to the vascular hyporesponsiveness to norepinephrine (NE) observed in carotid arteries from rats exposed to simulated microgravity. The goal of the present study was to determine whether a cyclooxygenase product of arachidonic acid also influences vascular responsiveness in this setting. Microgravity was simulated in rats by hindlimb unweighting (HU). After 20 days of HU, carotid arteries were isolated from control and HU-treated rats, and vascular rings were mounted in tissue baths for the measurement of isometric contraction. Two cyclooxygenase inhibitors, indomethacin and ibuprofen, and the selective thromboxane A(2) prostanoid-receptor antagonist, SQ-29548, had no effect on the contraction to NE in control vessels but markedly reduced contraction to NE in HU vessels. When the endothelium was removed, indomethacin no longer had any effect on the NE-induced contraction in HU vessels. In endothelium-intact vessels in the presence of indomethacin, the addition of the nitric oxide synthase inhibitor, N(G)-L-nitro-arginine methyl ester, to the medium bathing HU vessels increased the contraction to NE to the level of that of the control vessels. These results indicate that HU treatment induced two endothelial changes in carotid artery that opposed each other. Nitric oxide activity was increased and was responsible for the vascular hyporesponsiveness to NE. The activity of a vasoconstrictor prostaglandin was also increased, and attenuated the vasodilating effect of nitric oxide.

Non-NASA Center↗

Elastic modulus of the human intact left ventricle - Determination and physiological interpretation

The left ventricle (l.v.) is represented as a shell of muscle whose performance is characterized in terms of the chamber pressure and stress/strain in the ventricular wall; the effective elastic modulus of the l.v. relates these performance variables, and hence represents the transfer function of the left ventricular physiological system. A method is presented for indirectly determining the effective modulus E for the left ventricle. The method employs a thick-walled mathematical model of the l.v. having a homogeneous isotropic medium. Instantaneous values of E are determined for subjects with heart diseases of varied etiologies, in order to assess the responses of the l.v. to chronic overloads of pressure and volume. Resulting values for E are used diagnostically to characterize the physiological state of the l.v. Normal values of E, at systole, indicate that the strength of contraction exercised by the l.v. is normal, and hence is an indication of the l.v. having adjusted to the heart disease.

Ghista, D. N.↗

Muscular activity and its relationship to biomechanics and human performance

The purpose of this manuscript is to address the issue of muscular activity, human motion, fitness, and exercise. Human activity is reviewed from the historical perspective as well as from the basics of muscular contraction, nervous system controls, mechanics, and biomechanical considerations. In addition, attention has been given to some of the principles involved in developing muscular adaptations through strength development. Brief descriptions and findings from a few studies are included. These experiments were conducted in order to investigate muscular adaptation to various exercise regimens. Different theories of strength development were studied and correlated to daily human movements. All measurement tools used represent state of the art exercise equipment and movement analysis. The information presented here is only a small attempt to understand the effects of exercise and conditioning on Earth with the objective of leading to greater knowledge concerning human responses during spaceflight. What makes life from nonliving objects is movement which is generated and controlled by biochemical substances. In mammals. the controlled activators are skeletal muscles and this muscular action is an integral process composed of mechanical, chemical, and neurological processes resulting in voluntary and involuntary motions. The scope of this discussion is limited to voluntary motion.

Ariel, Gideon↗

Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct

There are only a few reports of the influence of imposed flow on an active lymph pump under conditions of controlled intraluminal pressure. Thus, the mechanisms are not clearly defined. Rat mesenteric lymphatics and thoracic ducts were isolated, cannulated and pressurized. Input and output pressures were adjusted to impose various flows. Lymphatic systolic and diastolic diameters were measured and used to determine contraction frequency and pump flow indices. Imposed flow inhibited the active lymph pump in both mesenteric lymphatics and in the thoracic duct. The active pump of the thoracic duct appeared more sensitive to flow than did the active pump of the mesenteric lymphatics. Imposed flow reduced the frequency and amplitude of the contractions and accordingly the active pump flow. Flow-induced inhibition of the active lymph pump followed two temporal patterns. The first pattern was a rapidly developing inhibition of contraction frequency. Upon imposition of flow, the contraction frequency immediately fell and then partially recovered over time during continued flow. This effect was dependent on the magnitude of imposed flow, but did not depend on the direction of flow. The effect also depended upon the rate of change in the direction of flow. The second pattern was a slowly developing reduction of the amplitude of the lymphatic contractions, which increased over time during continued flow. The inhibition of contraction amplitude was dependent on the direction of the imposed flow, but independent of the magnitude of flow. Nitric oxide was partly but not completely responsible for the influence of flow on the mesenteric lymph pump. Exposure to NO mimicked the effects of flow, and inhibition of the NO synthase by N (G)-monomethyl-L-arginine attenuated but did not completely abolish the effects of flow.

NASA Discipline Musculoskeletal↗

Blood pressure and mesenteric resistance arterial function after spaceflight

Ground studies indicate that spaceflight may diminish vascular contraction. To examine that possibility, vascular function was measured in spontaneously hypertensive rats immediately after an 18-day shuttle flight. Isolated mesenteric resistance arterial responses to cumulative additions of norepinephrine, acetylcholine, and sodium nitroprusside were measured using wire myography within 17 h of landing. After flight, maximal contraction to norepinephrine was attenuated (P < 0.001) as was relaxation to acetylcholine (P < 0.001) and sodium nitroprusside (P < 0.05). At high concentrations, acetylcholine caused vascular contraction in vessels from flight animals but not in vessels from vivarium control animals (P < 0.05). The results are consistent with data from ground studies and indicate that spaceflight causes both endothelial-dependent and endothelial-independent alterations in vascular function. The resulting decrement in vascular function may contribute to orthostatic intolerance after spaceflight.

short duration↗

A Biomechanical Comparison of 1-G and Fully-Loaded Simulated Zero-Gravity Locomotion

Exercise will almost certainly play an integral part in minimizing the bone mineral loss and muscular atrophy that occur during spaceflight. It has been hypothesized that an effective exercise regimen can be developed to elicit loads on the lower extremities and require muscle actions which resemble those encountered on Earth. The Penn State Zero-Gravity Simulator (PSZS) is a device which suspends subjects horizontally from multiple latex cords, with each cord negating the weight of a limb segment. A treadmill mounted on the wall under the PSZS enables subjects to run in simulated 0G. Subjects wear a harness to which a number of springs, which provide a gravity replacement load, are connected. The opposite end of each spring is connected to the side of the treadmill. During exercise, astronauts currently wear a similar harness in which the spring tethering load pulls at both the waist and shoulders. Ground reaction forces, muscular activations, and joint angles of the left leg during overground, treadmill, and fully-loaded zero-gravity simulated (ZLS) locomotion were assessed in order to gain insight into the effectiveness of the exercise regimen used by NASA to prevent the muscular atrophy and bone demineralization which occur in weightlessness. There were three hypotheses to this research. It was hypothesized that there will be no differences in peak ground reaction forces and peak loading rates between overground gait and gait in the full body weight loaded conditions in the ZLS. A second hypothesis was that that there will be no differences in hip, knee, and ankle joint positions between walking or running overground, on a standard treadmill, and in full bodyweight loaded conditions in the ZLS. The third hypothesis was that the muscular activations, as a percentage of maximal voluntary contraction, will be similar between walking or running overground, on a standard treadmill, and in full body-weight loaded conditions in the ZLS.

McCrory, Jean L.↗

Work and fatigue characteristics of unsuited and suited humans during isolated isokinetic joint motions

The effects of a pressurized suit on human performance were investigated. The suit is known as an Extra-Vehicular Mobility Unit (EMU) and is worn by astronauts while working outside their spacecraft in a low earth orbit. Isolated isokinetic joint torques of three female and three male subjects (all experienced users of the suit in 1G gravity) were measured while working at 100% and 80% of their maximum voluntary torque (MVT, which is synonymous with maximum voluntary contraction (MVC)). It was found that the average decrease in the total amount of work (the sum of the work in each repetition until fatigue) done when the subjects were wearing the EMU were 48% and 41% while working at 100% and 80% MVT, respectively. There is a clear relationship between the MVT and the time and amount of work done until fatigue. Here, the time to fatigue is defined as the ending time of the repetition for which the computed work done during that repetition dropped below 50% of the work done during the first repetition. In general the stronger joints took longer to fatigue and did more work than the weaker joints. It was found that the EMU decreases the work output at the wrist and shoulder joints the most, due to the EMU joint geometry. The EMU also decreased the joint range of motion. The average total amount of work done by the test subjects increased by 5.2% (20.4%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. Also, the average time to fatigue increased by 9.2% (25.6%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. It was also found that the experimentally measured torque decay could be predicted by a logarithmic equation. The absolute average errors in the predictions were found to be 18.3% and 18.9% for the unsuited and suited subjects, respectively, when working at 100% MVT, and 22.5% and 18.8% for the unsuited and suited subjects, respectively, when working at 80% MVT. These results could be very useful in the design of future EMU suits and the planning of Extra-Vehicular Activity (EVA) for the future International Space Station assembly operations.

NASA Discipline Life Sciences Technologies↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗