Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fast ion studies in the extended high-performance high β P plasma on EAST

Comprehending and optimizing fast ion behaviors is critical for the enhancement of performance in Experimental Advanced Superconducting Tokamak (EAST). This study explores the potential benefits of several factors that can improve the fast ion confinement. First, experiments show the change in the direction of the NBI2 from counter-I p to co-I p leads to a significant reduction in fast ion losses. TRANSP/NUBEAM simulation and tomography results based on fast-ion D-alpha measurements reveal that after the neutral beam injection (NBI) upgrade, the beam ion prompt loss is reduced by approximately 50%. Second, the upgraded ion cyclotron resonant frequency (ICRF) antenna at the N-port features twice the coupling resistance of the original antennas at EAST. This improved ICRF power coupling has enhanced the synergistic heating effect of NBI + ICRF, where the ICRF wave field accelerates beam ions at the harmonics. Experiments demonstrate that NBI + ICRF synergistic not only enhances plasma neutron yield and β P , but also accelerates beam ions to hundreds of keV. Further, the electron density and the neutral beam voltage have been optimized to reduce the fast ion slowing-down time and beam ion losses. Experimental and simulation results indicate that increasing the electron density reduces beam ion losses and enhances the bootstrap current fraction. While higher beam voltage results in a slight decrease in beam power absorption, it can increase the fraction of bootstrap current. With the understanding of these optimization of fast ion confinement, experiments have demonstrated fully non-inductive operation at high density (n e /n G ∼ 0.67, β P ∼ 3.1, β N ∼ 2.1, H 98,y2 ∼ 1.2) even without the support of co-I p beam NBI2. This investigation presents a potential regime to enhance fast ion confinement and extend performance in the high β P plasma for future experiments.

EAST tokamak↗

Discovery of 69 ms periodic X-ray pulsations in A0538-66

The detection of X ray pulsations with a period of 69.2126 ms from A0538-66 was done from the Einstein Observatory. A point source was located by the High Resolution Imager and a proportional counter registered a flux of 40 counts/sec over background. A column spectral density of 2 x 10 to the 23/sq cm identified the object as A0538-66. A persistent periodicity of 0.0692126 sec was observed throughout the event. The outbursts were not detected on three other observations of A0538-66, and a best fit to a change of rotation velocity indicated that the period observed was from a binary star with a Doppler shifted signal. The two stars are separated by less than 39 solar radii, with the larger star having a 40 solar radius. Consideration is given to the possibility that the X rays are due to accretion on a neutron star and that the two stars at times share a common envelope.

Skinner, G. K.↗

Modulation of Uptake and Reactivity of Nitrogen Dioxide in Metal-Organic Framework Materials

We report the modulation of reactivity of nitrogen dioxide (NO 2 ) in a charged metal–organic framework (MOF) material, MFM-305-CH 3 in which unbound N-centres are methylated and the cationic charge counter-balanced by Cl - ions in the pores. Uptake of NO 2 into MFM-305-CH 3 leads to reaction between NO 2 and Cl - to give nitrosyl chloride (NOCl) and NO 3 - anions. A high dynamic uptake of 6.58 mmol g -1 at 298 K is observed for MFM-305-CH 3 as measured using a flow of 500 ppm NO 2 in He. In contrast, the analogous neutral material, MFM-305, shows a much lower uptake of 2.38 mmol g -1 . The binding domains and reactivity of adsorbed NO 2 molecules within MFM-305-CH 3 and MFM-305 have been probed using in situ synchrotron X-ray diffraction, inelastic neutron scattering and by electron paramagnetic resonance, high-field solid-state nuclear magnetic resonance and UV/Vis spectroscopies. The design of charged porous sorbents provides a new platform to control the reactivity of corrosive air pollutants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Investigation of Target keff Search for Fuel Feed in MSRs

Fluid fuel molten salt reactor (MSR) concepts may achieve continuous-at-power operation with continuous or batch fresh fuel feed to counter reactivity loss from fuel burnup and fission product buildup. Accurate modeling and simulation of MSRs requires consideration of online fuel feed during depletion as well as a capability to determine the required feed amount to maintain a target multiplication factor (keff). As a first step supporting a full implementation of a new search capability into the SCALE code system’s TRITON reactor physics and depletion sequence, a preliminary investigation was performed to identify the best approach for a critical feed search capability considering computation time and accuracy. Using a simple iterative approach in which initial feed amounts were guessed based on previous depletion steps, the main drivers of computation time were found as the Monte Carlo neutron transport settings and the applied tolerance for the target keff. In the applied model, with tight convergence criteria (keff convergence to 8 pcm and a tolerance of ±15 pcm), the critical search calculation required twice the number of neutron transport calculations compared to a depletion calculation without critical search. In contrast, with a relaxed tolerance of ±50 pcm, the overall computation time for the critical search for merely increased by 30-40%. Further studies will be performed before implementing the critical search capability into TRITON.

Faulkner, Jonathon [ORNL]↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

X-ray emission from PSR 0355+54

We have obtained a 20 ks observation of PSR 0355+54 using the ROSAT position sensitive proportional counter (PSPC). The pulsar is detected with a count rate of 4.2(+/- 1.3) x 10(exp -3)/s above the background. While the approximately 70 source counts are insufficient for spectral fitting, we have derived source parameters for specific cases of power law as well as blackbody spectra. For a Crab-like spectrum (photon index alpha = 2) we find L(sub x)(0.1-2.4 keV) = 1.0 x 10(exp 32) ergs/s, somewhat higher than upper limits reported from Einstein observations but consistent with typical L(sub x) versus E-dot values for other pulsars. For blackbody emission, we derive a temperature upper limit of approximately 9.5 x 10(exp 5) K for emission from the entire neutron star surface, which is consistent with standard models for cooling of the neutron star interior given a characteristic age 10(exp 5.75) yr. No evidence is present for modulation at the 156 ms pulsar period, setting a weak upper limit of approximately 75% for the pulsed fraction of the X-ray signal.

Slane, Patrick↗

Characterization of beam ion loss in high poloidal beta regime on EAST

A critical issue for achieving the integrated operation of steady-state long-pulse high-confinement (H-mode) plasmas on experimental advanced superconducting tokamak (EAST) is to improve beam ion population confinement during neutral beam injection (NBI). To study the characterization of beam ion loss and improve beam ion confinement, the steady-state long pulse scenario discharges were conducted on EAST (β p $\geqslant$ 2.0, β N $\geqslant$ 1.7, q 95 $\geqslant$ 6.7 and H 98y2 $\geqslant$ 1.1) with NBI heating. Based on neutron yield, the beam voltage and line-averaged electron density were adjusted from 50 kV to 60 kV and 4.4 × 10 19 m –3 to 5.0 × 10 19 m –3 , respectively. The results show that the dominant mechanisms of beam ion loss are shine-through loss, prompt loss, and stochastic ripple loss. The shine-through loss fraction is determined by initial velocity, flight time and entire beam path. The change in prompt loss fraction is caused by the change in the deposition of beam ions. The change in stochastic ripple loss fraction is caused by the change in the initial fraction of trapped-confined ions. Detailed physics shows that the prompt loss fraction during counter-Ip injections (~45%) is far larger than during co-Ip injections (~5%) due to the finite orbit width. The lost ions are mainly deposited on the lower divertor or below the midplane since the direction of magnetic drift is vertical down. The orbit types of prompt loss during counter-Ip injections are mainly trapped-lost and ctr-passing lost. To minimize the prompt loss fraction during counter-Ip injections, a reversed Ip configuration (rev-Ip) discharge #94758 was conducted. The result suggests that the beam ion wall load fraction during counter-Ip tangential injection (~3%) is far lower than that in normal Ip configuration (nor-Ip) discharge #94820. It is also found that the confinement of beam ion population in the counter-Ip injection #94758 was greatly improved when compared to #94820. Finally, this study can provide unique support for the improvement of beam ion population confinement and for the performance evaluation of the NBI system on EAST and future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

The noncompact binary X-ray source 4U 2129+47

The 5.2 hr X-ray binary 4U 2129+47 was observed for a full orbital cycle using the imaging proportional counter detector and the monitor proportional counter detector aboard the Einstein Observatory, as well as a 0.9 m reflector for 5 hrs continuous optical photometry. The X-ray and optical light curves, the X-ray spectrum, and the times of optical and X-ray minimum were determined. The shape of the 5.2 hr X-ray light curve is independent of energy. A partial X-ray eclipse occurred which was centered on the time of optical minimum and which lasted 20 percent of the orbital period. During this interval the X-ray intensity varied smoothly by a factor of three, and the light curve was symmetric relative to the time of minimum. These findings argue that the X-ray emitting region is extended and highly ionized. A model is presented in which an accretion disk corona scatters radiation from a central accreting neutron star.

Mcclintock, J. E.↗

Statistical Properties of SGR 1806-20 Bursts

We present statistics of SGR 1806-20 bursts, combining 290 events detected with the Rossi X-Ray Timing Explorer/Proportional Counter Array, 111 events detected with the Burst and Transient Source Experiment, and 134 events detected with the International Cometary, Explorer. We find that the fluence distribution of bursts observed with each instrument are well described by power laws with indices 1.43, 1.76, and 1.67, respectively. The distribution of time intervals between successive bursts from SGR 1806-20 is described by a lognormal function with a peak at 103 s. There is no correlation between the burst intensity and either the waiting times until the next burst or the time elapsed since the previous burst. In all these statistical properties, SGR 1806-20 bursts resemble a self-organized critical system, similar to earthquakes and solar flares. Our results thus support the hypothesis that the energy source for soft gamma repeater bursts is crustquakes due to the evolving, strong magnetic field of the neutron star, rather than any accretion or nuclear power.

Gogus, Ersin↗

X-ray properties of the Be/X-ray system 28 0114+650 = LSI +65deg 010

Results are presented from experiments on the Einstein Observatory, HEAO 1, and OSO 8 on the temporal and spectral properties of 2S 0114+650. In a 12 hr Einstein monitor proportional counter and solid state spectrometer observation, two episodes of flaring occurred by an order of magnitude over about 1 hr. Variability on shorter time scales showed a preferred period of 14.9 minutes, but periodic pulsations were not seen in the HEAO 1 and OSO 8 data. The spectra above 1 keV were typical of accreting X-ray pulsars; the power law was E exp -alpha with alpha of about 1.2 for the number spectrum up to a cutoff at 14 keV. There is some evidence that the spectrum is steeper when the source is quiescent at low luminosity, but no large spectral changes attended the flares. Absorption column densities were consistent with interstellar reddening of the proposed companion, the Be star LSI +65 deg010. In the minute and hour variability and in the spectral character, 2S0114+650 is similar to other Be star-neutron star binary X-ray sources. Variations over several days in the OSO 8 data suggest orbital effects.

Koenigsberger, G.↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ROSAT observations of pulsed soft X-ray emission from PSR 1055-52

Utilizing the position-sensitive proportional counter and the high-resolution imager aboard the orbiting X-ray observatory ROSAT, we have detected pulsations at the radio period from the pulsar PSR 1055-52. The pulse shapes are energy-dependent and show a transition at about 0.5 keV where the phase angle of the pulse peak changes by about -120 deg and the pulsed fraction increases from 11 percent to 63 percent toward larger energies. Simple spectral models are found to be unsatisfactory, while multicomponent models, such as a soft blackbody and hard power-law tail, yield better fits to the pulse-height data. The hard power-law tail is consistent with the extension of the recently reported EGRET results and may indicate a common emission mechanism for the X-ray through GeV gamma-ray regime. The soft blackbody component with T(infinity) = (7.5 +/- 0.6) x 10 exp 5 K, if interpreted as the initial cooling of a neutron star, is consistent with standard cooling models and does not require the presence of exotic components.

Oegelman, Hakki↗

Parallel-Plate Avalanche Counter (PPAC) Fabrication for 240 Pu PFNS Measurement [Slides]

A LANL-LLNL joint program has been developed successfully to measure PFNS and established the most precisely determined $\chi$ matrices for 235,238 U and 239 Pu. It has been extended to 240 Pu now and possibly to 233 U in the future. An alternative method was developed to fabricate 240 Pu and a total of 12 targets were made with a total mass of 17.9 mg. The PFNS measurement for 240 Pu will begin in June, 2022 when the new beam cycle starts and the data analysis follows immediately afterward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovery of a 450 Hz Quasi-Periodic Oscillation from the Microquasar GRO J1655-40 with the Rossi X-ray Timing Explorer

We report the discovery with the Proportional Counter Array on board the Rossi X-Ray Timing Explorer of a 450 Hz quasi-periodic oscillation (QPO) in the hard X-ray flux from the Galactic microquasar GRO J1655-40. This is the highest frequency QPO modulation seen to date from a black hole. The QPO is detected only in the hard X-ray band above approx. 13 keV. It is both strong and narrow, with a typical rms (root mean square) amplitude of 4.5% in the 13-27 keV range and a width of approx. 40 Hz (FWHM). For two observations in which we detect the 450 Hz QPO, a previously known approx. 300 Hz QPO is also observed in the 2-13 keV band. We show that these two QPOs sometimes appear simultaneously, thus demonstrating the first detection of a pair of high-frequency QPOs in a black hole system. Prior to this, pairs of high-frequency QPOs have been detected only in neutron star systems. GRO J1655-40 is one of only a handful of black hole systems with a good dynamical mass constraint. For a nonrotating black hole with mass between 5.5 and 7.9 solar masses, the innermost stable circular orbit (ISCO) ranges from 45 to 70 km. For any mass in this range the radius at which the orbital frequency reaches 450 Hz is less than the ISCO radius, indicating that, if the modulation is caused by Kepler motion, the black hole must have appreciable spin. If the QPO frequency is set by the orbital frequency of matter at the ISCO, then for this mass range the dimensionless angular momentum lies in the range 0.15 < j < 0.5. Moreover, if the modulation is caused by oscillation modes in the disk or Lense-Thirring precession, then this would also require a rapidly rotating hole. We briefly discuss the implications of our findings for models of X-ray variability in black holes and neutron stars.

Strohmayer, Tod E.↗

Performance of NICER Flight X-Ray Concentrator

Neutron star Interior Composition ExploreR (NICER) is a NASA instrument to be onboard International Space Station, which is equipped with 56 pairs of an X-ray concentrator (XRC) and a silicon drift detector for high timing observations. The XRC is based on an epoxy replicated thin aluminum foil X-ray mirror, similar to those of Suzaku and ASTRO-H (Hitomi), but only a single stage parabolic grazing incidence optic. Each has a focal length of 1.085 m and a diameter of 105 mm, with 24 confocally aligned parabolic shells. Grazing incident angles to individual shells range from 0.4 to 1.4 deg. The flight 56 XRCs have been completed and successfully delivered to the payload integration. All the XRC was characterized at the NASA/GSFC 100-m X-ray beamline using 1.5 keV X-rays (some of them are also at 4.5 keV). The XRC performance, effective area and point spread function, was measured by a CCD camera and a proportional counter. The average effective area is about 44 sq cm at 1.5 keV and about 18 sq cm at 4.5 keV, which is consistent with a micro-roughness of 0.5 nm from individual shell reflectivity measurements. The XRC focuses about 91% of X-rays into a 2mm aperture at the focal plane, which is the NICER detector window size. Each XRC weighs only 325 g. These performance met the project requirement. In this paper, we will present summary of the flight XRC performance as well as co-alignment results of the 56 XRCs on the flight payload as it is important to estimate the total effective for astronomical observations.

X-ray concentrator↗

Statistical Properties of SGR 1900+14 Bursts

We study the statistics of soft gamma repeater (SGR) bursts using a database of 187 events detected with BATSE and 837 events detected with the Rossi X-Ray Timing Explorer Proportional Counter Array: all events are from SGR 1900+14 during its 1998-1999 active phase. We find that the fluence or energy distribution of bursts is consistent with a power law of index 1.66, over 4 orders of magnitude. This scale-free distribution resembles the Gutenberg-Richter law for earthquakes and gives evidence for self-organized criticality in SGRS. The distribution of time intervals between successive bursts from SGR 1900+14 is consistent with a lognormal distribution. There is no correlation between burst intensity and the waiting times till the next burst, but there is some evidence for a correlation between burst intensity and the time elapsed since the previous burst. We also find a correlation between the duration and the energy of the bursts, but with significant scatter. In all these statistical properties, SGR bursts resemble earthquakes and solar flares more closely than they resemble any known accretion-powered or nuclear-powered phenomena. Thus, our analysis lends support to the hypothesis that the energy source for SGR bursts is internal to the neutron star and plausibly magnetic.

Gogus, Ersin↗