At least 235 records · Page 13

Surface finish measurement studies

The performance of stylus instruments for measuring the topography of National Transonic Facility (NTF) model surfaces both for monitoring during fabrication and as an absolute measurement of topography was evaluated. It was found that the shop-grade instruments can damage the surface of models and that their use for monitoring fabrication procedures can lead to surface finishes that are substantially out of range in critical areas of the leading edges. The development of a prototype light-scattering instrument which would allow for rapid assessment of the surface finish of a model is also discussed.

Teague, E. C.↗

Angle of attack system

The development of systems for measuring model pitch and roll attitude in the National Transonic Facility (NTF) is discussed. The effort is divided between two approaches: (1) an inertial measurement that is an extrapolation of existing technology into a cryogenic environment, and (2) an optical technique based on a holographic angle sensor.

Finley, T. D.↗

Control of large thermal distortions in a cryogenic wind tunnel

The National Transonic Facility (NTF) is a research wind tunnel capable of operation at temperatures down to 89K (160 R) and pressures up to 900,000 Pa (9 atmospheres) to achieve Reynolds numbers approaching 120,000,000. Wide temperature excursions combined with the precise alignment requirements of the tunnel aerodynamic surfaces imposed constraints on the mechanisms supporting the internal structures of the tunnel. The material selections suitable for this application were also limited. A general design philosophy of utilizing a single fixed point for each linear degree of freedom and guiding the expansion as required was adopted. These support systems allow thermal expansion to take place in a manner that minimizes the development of thermally induced stresses while maintaining structural alignment and resisting high aerodynamic loads. Typical of the support mechanisms are the preload brackets used in the fan shroud system and the Watts linkage used to support the upstream nacelle. The design of these mechanisms along with the basic design requirements and the constraints imposed by the tunnel system are discussed.

Gustafson, J. C.↗

Mechanical properties of adhesive systems at cryogenic and other temperatures

This paper presents a summary of the National Transonic Facility (NTF) fan blade adhesive characterization tests. Data was obtained at -300 F, room temperature (RT) and 200 F. The adhesive characterization data was acquired using specimens fabricated from materials orientated to simulate the lay up of the fan blades. Specimen fabrication, characterization tests, test equipment, test data, results and concluding remarks are reported. Adhesive test results are presented for specimens of the following types: lap shear, double lap shear, butt, short beam shear, flexure, and differential strain.

Staton, W. L.↗

Video model deformation system for the National Transonic Facility

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. A rudimentary theory section is followed by a description of the video-based system and control measures required to protect cameras from the hostile environment. Preliminary results obtained with the same camera placement as planned for NTF are presented and plans for facility testing with a specially designed test wing are discussed.

Burner, A. W.↗

Status of orifice induced pressure error studies

The construction of high Reynolds number facilities, such as the National Transonic Facility (NTF) and the 0.3-m Transonic Cryogenic Tunnel (TCT), has stimulated interest again in the study of orifice induced static pressure. In a high Reynolds number facility, the orifice will have a much larger effect on the boundary layer than in a conventional wind tunnel. The present investigation was performed in the 0.3-m TCT at Mach numbers in the range from 0.60 to 0.80 and Reynolds numbers in the range from 6,000,000 to 40,000,000 with the objective to compare the porous plug orifices to conventional 0.025 cm orifices in a high Reynolds number environment. It was found that there was an error at high Reynolds numbers which could not be neglected and that the use of a porous metal disk in a conventional orifice could virtually eliminate the orifice induced pressure error.

Plentovich, E. B.↗

Thermal analysis of cryogenic wind tunnel models

This paper summarizes the thermal analysis activity being performed in support of the design of wind tunnel models for the National Transonic Facility (NTF) at the NASA Langley Research Center. The goal of the analysis effort has been to address model design difficulties associated with the severe thermal environment of this cryogenic wind tunnel. The unique characteristics of this environment are discussed for various phases of tunnel operation. The methods used to calculate temperatures and thermal stresses in the models are also described. The results indicate that thermal considerations do not drive the design to the extent originally envisioned. In general, the problems identified are localized and associated with thermal mismatch between components. Several specific examples of thermal design problems and proposed solutions are given.

Carlson, A. B.↗

Connectors and Wiring for Cryogenic Temperatures

Tests performed at Langley Research Center to find connectors, cables, and other electrical components suitable for use in cryogenic environment described. In addition, several electrical cables have to flex under cryogenic conditions. Tests necessary to qualify materials for use in National Transonic Facility (NTF), which operates at temperature range from 175 degrees to - 300 degrees F (353 to 89 K).

Turner, R. D.↗

Stereo Electro-optical Tracking System (SETS)

The SETS is a remote, non-contacting, high-accuracy tracking system for the measurement of deflection of models in the National Transonic Facility at Langley Research Center. The system consists of four electronically scanned image dissector trackers which locate the position of Light Emitting Diodes embedded in the wing or body of aircraft models. Target location data is recorded on magnetic tape for later 3-D processing. Up to 63 targets per model may be tracked at typical rates of 1280 targets per second and to precision of 0.02mm at the target under the cold (-193 C) environment of the NTF tunnel.

Koenig, E. W.↗

National transonic facility shakedown test results and calibration plans

The results of the shakedown tests and the calibration plan of the National Transonic Facility (NTF) are presented. The facility is designed to operate in both air and nitrogen modes, cover Mach numbers from 0.2 to 1.2, pressures up to 8.8 atm and temperatures between 77 and 339 K. The facility data system is built around four 16-bit minicomputers with a total memory of three megabytes. A portable cryogenic chamber is available. The tunnel systems were operated in a series of tests in Mach number range of 0.2 to 1.17, pressures up to 8.5 atm, and temperatures down to 100 K. The calibration plan includes steady-state and dynamic calibration, as well as wall interference studies. The facility underwent the checkout of the model attitude, plenum isolation, and model access systems, followed by aerodynamic calibration in 1984. Schematic drawings and diagrams are included.

Bruce, W. E., Jr.↗

Evaluation of a Quartz Bourdon Pressure Gage of Wind Tunnel Mach Number Control System Application

A theoretical and experimental study was undertaken to determine the feasibility of using the National Transonic Facility's high accuracy Mach number measurement system as part of a closed loop Mach number control system. The theoretical and experimental procedures described are applicable to the engineering design of pressure control systems. The results show that the dynamic response characteristics of the NTF Mach number gage (a Ruska DDR-6000 quartz absolute pressure gage) coupled to a typical length of pressure tubing were only marginally acceptable within a limited range of the facility's total pressure envelope and could not be used in the Mach number control system.

Chapin, W. G.↗

Effect of Reynolds Number and Mach Number on flow angularity probe sensitivity

Preliminary calibrations were performed on nine flow angularity probes in the Langley 7- by 10-Foot High-Speed Tunnel (7 x 10 HST) and the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). These probes will be used in surveying the test section flows of the National Transonic Facility (NTF). The probes used in this study have a pyramid head with five pressure orifices. The calibrations consisted of both isolated probe measurements and rake-mounted multiprobe measurements that covered a range of subsonic Mach numbers up to 0.90 and Reynolds numbers per foot up to 40 X 10 to the 6th power. The preliminary calibration in the 7 x 10 HST included testing the probes both individually and in a rake. The 0.3-m TCT calibration tested two probes singly at varying Reynolds numbers. The results from these tests include Mach number, Reynolds number, and rake-mounting effects. The results of these tests showed probe sensitivity to be slightly affected by Mach number. At Reynolds numbers per foot above 10 x 10 to the 6th power, the probe did not exhibit a Reynolds number sensitivity.

Smith, L. A.↗

Description and operational status of the National Transonic Facility computer complex

This paper describes the National Transonic Facility (NTF) computer complex and its support of tunnel operations. The capabilities of the research data acquisition and reduction are discussed along with the types of data that can be acquired and presented. Pretest, test, and posttest capabilities are also outlined along with a discussion of the computer complex to monitor the tunnel control processes and provide the tunnel operators with information needed to control the tunnel. Planned enhancements to the computer complex for support of future testing are presented.

Boyles, G. B., Jr.↗

The National Transonic Facility

The National Transonic Facility, NTF, is a high Reynolds Number facility where the increase in Reynolds Number is obtained by operating at high pressures and low temperatures. Liquid nitrogen is allowed to vaporize, making gaseous nitrogen the test medium with temperatures extending down to approximately 100 degrees Kelvin. These factors have created unique, new challenges to those developing sensors and instrumentation. Pressure vessels, thermal enclosures or elaborate temperature compensations schemes, are needed for environmental protection and special materials are needed for sensors and model fabrication. The need for a new measurement, model deformation, was also created. An extensive program to develop the unique sensors and instrumentation was initiated. The data acquisition system and systems to measure aerodynamic forces and pressures, model attitude, and model deformation, are discussed.

Holmes, H. K.↗

Selected vortex-lift research at NASA Langley Research Center

A focused overview is presented of theoretical and experimental work underway at the NASA Langley Research Center pertinent to separation-induced vortex flows. The theoretical material selected for this review reflects the breadth of methodology in use and under development with limited discussion of details. The experimental discussion concentrates on planned testing of a delta wing in the NTF as well as other facilities. The historical perspective of this current work is also addressed.

Luckring, James M.↗

Wind tunnel wall interference

About a decade ago, interest in alleviating wind tunnel wall interference was renewed by advances in computational aerodynamics, concepts of adaptive test section walls, and plans for high Reynolds number transonic test facilities. Selection of NASA Langley cryogenic concept for the National Transonic Facility (NTF) tended to focus the renewed wall interference efforts. A brief overview and current status of some Langley sponsored transonic wind tunnel wall interference research are presented. Included are continuing efforts in basic wall flow studies, wall interference assessment/correction procedures, and adaptive wall technology.

Newman, Perry A.↗

Preliminary calibration and test results from the National Transonic Facility

The National Transonic Facility (NTF) was operated to design condition of 120 million Reynolds number at a Mach number of 1.0. All systems were checked out except plenum isolation valves; modifications are being made to heaters on the actuators. Initial steady-state calibration indicates excellent steady flow characteristics. The first test of the Pathfinder 1 model indicated significant Reynolds number effects. Some effect of temperature on instrumentation were obtained. The cause of these effects is being evaluated.

Mckinney, Linwood W.↗

Testing and checkout experiences in the National Transonic Facility since becoming operational

The U.S. National Transonic Facility, constructed by NASA to meet the national needs for High Reynolds Number Testing, has been operational in a checkout and test mode since the operational readiness review (ORR) in late 1984. During this time, there have been problems centered around the effect of large temperature excursions on the mechanical movement of large components, the reliable performance of instrumentation systems, and an unexpected moisture problem with dry insulation. The more significant efforts since the ORR are reviewed and NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality and process controls is summarized.

Bruce, W. E., Jr.↗