Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Radiation Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

The present disclosure relates to a method for detecting incoming radiation having a plurality of differing properties including at least one of differing types, differing energies or differing incoming directions. The method involves using a scintillator structure formed from first and second dissimilar scintillator materials, where the first and second dissimilar scintillator materials emit first and second different colors of light in response to the incoming radiation. A first light detector is used for detecting light having the first color, and a second light detector is used for detecting light having the second color. A first output signal is generated in response to the detection of light having the first color, and a second output signal is generated in response to detecting light having the second color. The first and second output signals are then analyzed to determine at least one property of the incoming radiation.

Brodsky, Jason Philip↗

Neutron Induced Nuclear Reaction Cross Sections for Radiochemistry in the Region of Thallium, Lead, and Bismuth

We have developed a set of modeled nuclear reaction cross sections for use in radiochemical detector diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model developed in the TALYS code system are used to calculate neutron induced nuclear reaction cross sections for targets ranging from Thallium (Z = 81) to Bismuth (Z = 83).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Final Design of a New Pulsed-Neutron Die-Away Experimental Testbed for Thermal Scattering Law Benchmarks (PNDA) (IER-501 CED-2)

This report presents the final design (CED-2) of IER-501, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The PNDA experiments will be high-quality benchmarks that serve to optimize and validate thermal neutron scattering laws (TSLs), which are high-priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). This CED-2 was guided by experimental results gathered from a prototype experimental set-up rather than with detailed simulations as is typically done for criticality experiments. The report presents the PNDA design and its equipment, and it documents the methodology used to postprocess the measured data. It discusses how experimental configurations influenced the decay-constant eigenvalue, or the integral parameter, of the experiment. The studied variations included the distance from the target to the generator, the orientation of the generator relative to the box, the orientation of the target to the generator, the effect of HDPE lining in the shielding box, the settings of the generator, and finally the benefits of using a low-scatter facility. From these results, a final configuration for the target, detectors, shielding box, and neutron generator was chosen. Two factors particularly influenced the chosen configuration: the reproducibility of the experiment’s geometry for benchmark modeling, and the minimization of measured neutrons scattered off the shielding box.

42 ENGINEERING↗

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directed Flow and the Chiral Magnetic Effect in Ultrarelativistic Collisions at the LHC with CMS at the LHC (Final Technical Report)

This Technical Report focuses on two aspects of this project. First, the results from the calibration of the Spectator Reaction Plane Detector (SRPD) addition to the Zero Degree Calorimeter (ZDC) in the CMS experiment are presented, followed by the pre-liminary results from radiation studies of quartz being performed using the electron linac here at the University of Maryland. The data taken in the November 2018 run are being analyzed with the ultimate goal of producing a reaction plane measurement using spectator neutrons detected in the ZDC. Funds provided by this grant partially supported the graduate student who is performing these calibrations. They were also used to support radiation tests of quartz rod material being performed at the University of Maryland Radiation Facilities Electron Linear Accelerator.

43 PARTICLE ACCELERATORS↗

Update of CEA DES Criticality-Safety Activities and Perspectives [Slides]

Neutronics staff at CEA DES are in charge of a whole set of modeling and simulation tools for neutronics: nuclear data evaluation and processing, transport codes development, calculation sequences edition, verification, validation and uncertainty analysis. Advanced user groups are in charge of specific nuclear analysis in reactor physics, fuel cycle, criticality-safety, radiation shielding and nuclear instrumentation for CEA and its partners, at all stages of nuclear facilities life cycle. CEA is willing to participate/collaborate on the following issues: detector design, experiments, analysis and evaluation, DH validation by combining TAGS measurements with Fission Yield variance-covariance matrices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total kinetic energy and mass yields from the fast neutron-induced fission of $^{239}\hbox {Pu}$

The total kinetic energy (TKE) release in fission is an important observable, constituting over 80% of the energy released in fission (E f ≈ 200MeV). While the TKE release in the 239 Pu(n,f) reaction was previously measured up to 50 MeV incident neutron energy (E n ), there were features in TKE release at the highest values of E n that were puzzling. There was a marked flattening of TKE release from E n = 30 to 50 MeV, in disagreement with the clearly decreasing TKE observed from E n = 0.5 to 30 MeV. To verify and clarify this trend, TKE measurements at higher values of E n were made. We present absolute measurements of TKE release in 239 Pu(n,f) from E n = 2.4 to 100 MeV. Here, we used silicon PIN detectors to measure the fragment energies and deduce mass-yield curves using the 2E-method. We also discuss fission asymmetry and the relationships between approx. fission fragment mass and distortion.

239Pu↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chasing Gamma-Ray Signals from Binary Neutron Star Coalescences with the Cherenkov Telescope Array: Prospects and Observing Strategies

The detection of gravitational waves (GWs) from a binary neutron star (BNS) merger by Advanced LIGO and Advanced Virgo (GW170817), together with its electromagnetic counterpart, the short gamma-ray burst GRB 170817A, heralded the birth of multimessenger astronomy. The detection of TeV emission from GRBs motivates follow-up observations with the Cherenkov Telescope Array Observatory (CTAO), which is ideal for detecting such signals due to its unprecedented sensitivity, rapid response, and wide-field survey capabilities. The aim of this work is to evaluate GeV–TeV GW follow-up strategies for CTAO using a multistep simulation pipeline and to estimate the expected rate of joint GW–GRB detections during observing run O5. Using a simulated sample of BNS systems with corresponding GW detections, gamma-ray emission is simulated through phenomenological prescriptions based on the observed population of short GRBs, including off-axis jet scenarios. CTAO observations are simulated to account for instrument response, sky tiling strategies, integration times, and varying observing conditions. Strategies with variable and constant integration times are investigated. We find that, via an optimized follow-up strategy, about 5% of simulated GW-associated short GRBs produce GeV–TeV radiation detectable by CTAO. Detectability is strongly influenced by the jet opening angle and viewing angle, suggesting that even rough estimates of the viewing angle in GW alerts could enhance targeting. This framework motivates future follow-ups of GW-detectable events, including neutron star–black hole mergers, and further supports the development of advanced strategies incorporating galaxy distributions and synergies with future detectors such as the Einstein Telescope.

Abe, S. [University of Tokyo] (ORCID:0000000172503↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

Verification of Spent Fuel Inside Dry Storage Casks Using Neutron Mapping (2022 Midyear Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested to demonstrate a practical rapid verification system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

A scintillator system is disclosed for detecting incoming radiation. The system makes use of a scintillator structure having first and second dissimilar materials. The first dissimilar material emits a first color of light and the second dissimilar material emits a second color of light different from the first color of light. Either one, or both, of the first or second colors of light are emitted in response to receipt of the incoming radiation. A plurality of light detectors is disposed in proximity to the scintillator structure for detecting the first and second different colors of light and generating output signals in response thereto. A detector electronics subsystem is responsive to the output signals and provides an indication of colors emitted by the scintillator structure to infer at least one property of the incoming radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel deuterium–tritium (DT) neutron activation diagnostics for increased neutron yield operations at Sandia’s Z-facility (invited)

As inertial confinement fusion experiments at Sandia National Laboratories’ Z-facility begin using deuterium–tritium (DT) fuels, the expected DT-neutron yields are expected to increase many orders of magnitude. This brings about the need for diagnostics that have a significantly higher dynamic range of operation and ability to obtain yields where there will be significant radiation holds. Using the current activation diagnostic infrastructure at the Z-facility, a pair of activation diagnostics are being developed. Here, the first is fluorine activation, which will be used in a similar manner to current copper activation diagnostics that are fielded in a rabbit for quick removal from the experiments without opening the vacuum experiment containment. The second is a prompt DT-neutron detector that exploits the activation of oxygen with similar operation characteristics as the current Be-probes fielded at Z. We will discuss the design of this pair of instruments, along with calibration work performed at Sandia’s Ion Beam Laboratory in support of the development and anticipated instrument performance.

Mangan, Michael Antony↗

Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker

During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×10 34 cm –2 s –1 . A total integrated luminosity of 3000 or even 4000 fb –1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC,with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons,and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 3000 fb –1 . The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗