Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Emergency Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

230 records · Page 13

A high performance UV–visible dual-band photodetector based on an inorganic Cs 2 SnI 6 perovskite/ZnO heterojunction structure

Inorganic metal halide (IMH) perovskites have recently emerged as highly promising optoelectronic materials due to their excellent material properties, including tunable direct bandgap, long carrier diffusion length, high carrier mobility and outstanding environmental stabilities. However, the performance of photodetectors fabricated from IMH perovskites so far is limited as compared to their counterparts based on organic–inorganic hybrid perovskites. In this work, we demonstrate a high performance ultraviolet–visible (UV–Vis) dual-band photodetector based on a Cs 2 SnI 6 /ZnO heterojunction structure. Therefore, by adjusting the polarity of the applied bias voltage, the photodetector can switch between two operation modes: (1) UV–Vis dual-band detection mode and (2) visible-blind UV detection mode. High detectivity in both the UV (1.39 × 10 12 Jones) and visible (5.88 × 10 11 Jones) regions is achieved. In addition, this photodetector demonstrated a fast response speed with a rise and fall time on the order of milliseconds and a large linear dynamic range of 119 dB. The excellent performance of this photodetector originates from efficient charge separation at the heterojunction interfaces, which will be discussed in detail in terms of the energy band diagrams and carrier dynamics of the device. Our study demonstrates the great application potential of inorganic vacancy-ordered perovskites in high-performance heterojunction photodetectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic nanodomains dictate macroscopic properties in lead halide perovskites

Lead halide perovskites have emerged as promising materials for solar energy conversion and X-ray detection owing to their remarkable optoelectronic properties. However, the microscopic origins of their superior performance remain unclear. Here we show that low-symmetry dynamic nanodomains present in the high-symmetry average cubic phases, whose characteristics are dictated by the A-site cation, govern the macroscopic behaviour. We combine X-ray diffuse scattering, inelastic neutron spectroscopy, hyperspectral photoluminescence microscopy and machine-learning-assisted molecular dynamics simulations to directly correlate local nanoscale dynamics with macroscopic optoelectronic response. Our approach reveals that methylammonium-based perovskites form densely packed, anisotropic dynamic nanodomains with out-of-phase octahedral tilting, whereas formamidinium-based systems develop sparse, isotropic, spherical nanodomains with in-phase tilting, even when crystallography reveals cubic symmetry on average. We demonstrate that these sparsely distributed isotropic nanodomains present in formamidinium-based systems reduce electronic dynamic disorder, resulting in a beneficial optoelectronic response, thereby enhancing the performance of formamidinium-based lead halide perovskite devices. By elucidating the influence of the A-site cation on local dynamic nanodomains, and consequently, on the macroscopic properties, we propose leveraging this relationship to engineer the optoelectronic response of these materials, propelling further advancements in perovskite-based photovoltaics, optoelectronics and X-ray imaging.

Materials Science↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of He Ion Irradiation in Simple Borosilicate Glasses for HLW Immobilisation - 20324

High-level radioactive waste (HLW) consists of fission products and minor actinides. Borosilicate glass is the host material of choice in most countries to safely immobilize HLW, followed by eventual geological disposal. HLW glasses will experience both self-heating and self-irradiation effects due to the decay of fission products and minor actinides present therein. During the first 500 years of geological disposal, beta-gamma decay will be the main source of radiation due to short half-lives of fission products, as compared to very long-lived actinides which will be responsible for irradiation over much longer timescales. High-energy alpha particles and alpha recoil nuclei can potentially have significant impact (stored energy, volume change, accumulated dose, chemical durability) on the performance of the wasteform over longer timescales. Thus, to ensure safe and economic disposal over geological periods (10{sup 4} - 10{sup 6} years), the assessment of performance and properties in terms of radiation effects becomes indispensable. This work aims to simulate the effects of alpha decay in radioactive waste glasses. Two international glasses, namely UK 'MW' lithium-sodium borosilicate and Indian sodium-barium borosilicate, which are being used as HLW immobilization matrices by the UK and India respectively, were prepared by a melt-quench method and annealed below their glass transition temperatures. Both glasses were irradiated with 650 KeV He{sup 2+} ions with doses ranging from 10{sup 15} to 10{sup 17} ions/cm{sup 2}. Structural analysis was carried out using electron paramagnetic resonance (EPR) and Raman spectroscopies. First derivative continuous wave EPR spectra were recorded for all pristine and irradiated glass monoliths at room temperature using an X-band (frequency 9.6 GHz) EPR Bruker spectrometer. Results from EPR analyses showed the formation of irradiation induced paramagnetic centers at g ∼ 2.00 in all irradiated glasses. Raman spectra of pristine and irradiated samples were acquired, and showed notable changes in glass structure post-irradiation, with the emergence of a broad Raman band at 1560 cm{sup -1} upon irradiation with high fluences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Utilization of Space Nuclear Systems for Robotic and Human Exploration Missions: Response to EO 13972: Promoting Small Nuclear Reactors for National Defense and Space Exploration

Space Nuclear Systems (SNS) technology development offers a wide range of capabilities to support NASA’s current and future missions. Executive Order (EO) 13972, “Promoting Small Modular Reactors for National Defense and Space Exploration” [1], issued 5 January 2021, directs NASA to define requirements for NASA utilization of nuclear energy systems for human and robotic exploration missions through 2040 and analyze the costs and benefits of such requirements.” Although it is premature to define requirements and cost for future exploration missions that have not yet been formulated, this report describes planned objectives and missions by 2040 that are enabled or enhanced by nuclear systems while taking into account a number of unique considerations for nuclear energy in the space environment. Nuclear energy systems are enabling for space missions and critical capabilities where conventional forms of energy production are impractical or impossible due to mass constraints, mission duration, or distance from the Sun. Space nuclear technologies available or in development for use by 2040 utilize radioisotope decay or nuclear fission and fall into three categories: heat, power, and propulsion. Current applications utilize radioisotope power systems that provide consistent and reliable performance in the sub-kilowatt power range. More advanced SNS can enable new mission objectives where high energy density solutions are critical, or where access to solar solutions is prohibitive. Higher power radioisotope and fission systems are under development within NASA for a wide variety of human exploration and science mission applications. Planned missions designed to use radioisotope systems include Dragonfly, a rotorcraft that will explore the surface of Titan, and Persephone, a mission concept for a Pluto orbiter. Nuclear fission systems have the key advantage of providing significantly higher power, lower mass solutions from tens to even thousands of kilowatts. Fission power is enabling to a sustained human presence on the Moon and developing a robust lunar economy. Fission propulsion is enabling for missions within and beyond cis-lunar space. This report examines NASA-envisioned mission applications and associated performance needs for SNS over the next twenty years leading to 2040 along with the unique technical considerations posed by space nuclear technology development. This includes engineering and operational logistics for ground handling, thermal management, survival of the space environment, operational safety, power requirements, and service longevity. Safety to the public, the NASA work force, and agency assets remains a top priority for NASA and particular attention is given to this aspect in the design, hardware assembly, ground operation, launch, and mission operation of an SNS. NASA relies on the Department of Energy as nuclear authority and its legacy of rigorous safety procedures as standards for ground development, test, transportation, and launch site operation. The principal concern is preventing unintended radiological release to the public or environment. Radioisotope system experience has established processes, including ground operation, transportation, and launch, that are considered directly applicable to emerging fission systems; however, fission systems have unique design needs that impact the safety and performance requirements. High efficiency power conversion from both fission and radioisotope systems requires high operating temperatures necessitating both passive and active thermal management to maintain safe and nominal operating conditions. Effective cooling and waste heat rejection have special considerations for space applications, whether in zero-g or reduced gravity. Fluid and heat transfer within the reactor system is not anticipated to be impacted by reduced or zero-g environments. Cryogenic working fluids and propellant supplies utilized in some space nuclear applications will need low mass, high capacity cryocoolers to meet the long-term storage and near zero-boiloff needs. Integrated, high power density SNS capable of being packaged in a single vehicle is a key consideration for NASA. Due to concerns for complexity and reliability, in space reactor assembly and reactor refueling are not current design considerations. Expanding into a new era for space exploration depends on mass-efficient, high-energy solutions to power deep-space vehicles, operate in harsh environments, and increase mission flexibility. NASA nuclear technology investments are targeting power for surface operations and propulsion for fast-transit, deep-space missions, all with the ability to reliably operate without the need for repair or refueling. NASA’s goals, enabled by nuclear technologies, provide for exciting advances in scientific objectives and human exploration, ushering in a new space age that enables a human presence on bodies beyond our Earth.

nuclear↗

Normal Tissue Injury Induced by Photon and Proton Therapies: Gaps and Opportunities

Despite technological advances in radiation therapy (RT) and cancer treatment, patients still experience adverse effects. Proton therapy (PT) has emerged as a valuable RT modality that can improve treatment outcomes. Normal tissue injury is an important determinant of the outcome; therefore, for this review, we analyzed 2 databases: (1) clinical trials registered with ClinicalTrials.gov and (2) the literature on PT in PubMed, which shows a steady increase in the number of publications. Most studies in PT registered with ClinicalTrials.gov with results available are nonrandomized early phase studies with a relatively small number of patients enrolled. From the larger database of nonrandomized trials, we listed adverse events in specific organs/sites among patients with cancer who are treated with photons and protons to identify critical issues. The present data demonstrate dosimetric advantages of PT with favorable toxicity profiles and form the basis for comparative randomized prospective trials. A comparative analysis of 3 recently completed randomized trials for normal tissue toxicities suggests that for early stage non-small cell lung cancer, no meaningful comparison could be made between stereotactic body RT and stereotactic body PT due to low accrual (NCT01511081). In addition, for locally advanced non-small cell lung cancer, a comparison of intensity modulated RT with passive scattering PT (now largely replaced by spot-scanned intensity modulated PT), PT did not provide any benefit in normal tissue toxicity or locoregional failure over photon therapy. Finally, for locally advanced esophageal cancer, proton beam therapy provided a lower total toxicity burden but did not improve progression-free survival and quality of life (NCT01512589). The purpose of this review is to inform the limitations of current trials looking at protons and photons, considering that advances in technology, physics, and biology are a continuum, and to advocate for future trials geared toward accurate precision RT that need to be viewed as an iterative process in a defined path toward delivering optimal radiation treatment. A foundational understanding of the radiobiologic differences between protons and photons in tumor and normal tissue responses is fundamental to, and necessary for, determining the suitability of a given type of biologically optimized RT to a patient or cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed study of quark-hadron duality in spin structure functions of the proton and neutron

Background: The response of hadrons, the bound states of the strong force (QCD), to external probes can be described in two different, complementary frameworks: as direct interactions with their fundamental constituents, quarks and gluons, or alternatively as elastic or inelastic coherent scattering that leaves the hadrons in their ground state or in one of their excited (resonance) states. The former picture emerges most clearly in hard processes with high momentum transfer, where the hadron response can be described by the perturbative expansion of QCD, while at lower energy and momentum transfers, the resonant excitations of the hadrons dominate the cross section. The overlap region between these two pictures, where both yield similar predictions, is referred to as quark-hadron duality and has been extensively studied in reactions involving unpolarized hadrons. Some limited information on this phenomenon also exists for polarized protons, deuterons, and 3 He nuclei, but not yet for neutrons. Purpose: In this paper, we present comprehensive and detailed results on the correspondence between the extrapolated deep inelastic structure function g 1 of both the proton and the neutron with the same quantity measured in the nucleon resonance region. Thanks to the fine binning and high precision of our data, and using a well-controlled perturbative QCD (pQCD) fit for the partonic prediction, we can make quantitative statements about the kinematic range of applicability of both local duality and global duality. Method: We use the most updated QCD global analysis results at high x from the Jefferson Lab Angular Momentum Collaboration to extrapolate the spin structure function g 1 into the nucleon resonance region and then integrate over various intervals in the scaling variable x. We compare the results with the large data set collected in the quark-hadron transition region by the CLAS Collaboration, including, for the first time, deconvoluted neutron data, integrated over the same intervals. We present this comparison as a function of the momentum transfer Q 2 . Results: We find that, depending on the integration interval and the minimum momentum transfer chosen, a clear transition to quark-hadron duality can be observed in both nucleon species. Furthermore, we show, for the first time, the approach to scaling behavior for g 1 measured in the resonance region at sufficiently high momentum transfer. Conclusions: Here, our results can be used to quantify the deviations from the applicability of pQCD for data taken at moderate energies and can help with extraction of quark distribution functions from such data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Student Support for the “Frontiers in Attosecond & Ultrafast X-ray Science” School

The new millennium witnessed two revolutionary breakthroughs in ultrafast x-ray science: table-top XUV sources based on high harmonic generation in gases ushered in the attosecond era while facility-based x-ray free-electron lasers opened the path for intense, femtosecond hard x-rays. This award requested scholarship funds for a 2019 and 2023 School whose prime objective was the training of young scientists in these emerging complementary areas both relevant to DOE BES mission. The school entitled the “Frontiers of Attosecond and Ultrafast X-ray Science (FAXS)” (http://www.erice-attosecond.it/) was the second and fourth in a series, which began in 2017. The two Schools were held during March 10-16, 2019 and March 26-31, 2023 at the Ettore Majorana Foundation and Centre for Scientific Culture (http://www.ccsem.infn.it/) in Erice, Sicily. The DOE funds supported the registration fee for young scientists (graduate students and postdocs) from US institutions. The registration fees included School participation, lodging and meals over the duration of the School. Note, the third addition of the School was held in 2022 as a virtual event due to the pandemic, DOE funds were not necessary for this event. The FAXS School is a course of the 62th and 63rd International School of Quantum Electronics under the directorship of Prof. Diederik Wiersma (University of Florence). The Directors for the FAXS School are Louis DiMauro (The Ohio State University, USA) and Mauro Nisoli (Politecnico di Milano, Italy). The FAXS School program consisted of approximately 10 lectures by leading experts in attosecond and x-ray science (see attached list). Most lecturers delivered a series of three 1-hour lectures. The lecturers were required to spend the full 5 days at the school so to promote interaction with the students. The Erice Majorana Center venue accommodated ~75 young scientists. The registration fee covered the cost of participating in the school, lodging and meals for the entire duration of the school. The schedule consisted of lectures every morning and afternoon except for one afternoon that was reserved for an archaeological excursion. Every evening had a student/postdoc poster session and social gatherings at the Majorana Center to encourage further interaction of all participants and lecturers. The two FAXS Schools attracted an international group of young scientists. The DOE funds supported the registration fee for 11 students/postdocs from US institutions (5 supported in 2019 and 6 supported in 2023). The management of the DOE fellowships were administered through the Research Foundation of The Ohio State University. FAXS scholarships for European students/postdocs were provided by European funding sources administered by co-Director, Prof. Nisoli. All students/postdocs were encouraged to present a poster. Travel expenses to the FAXS School were the responsibility of the student/postdoc home institution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing tension metrics with dark energy survey and Planck data

ABSTRACT Quantifying tensions – inconsistencies amongst measurements of cosmological parameters by different experiments – has emerged as a crucial part of modern cosmological data analysis. Statistically significant tensions between two experiments or cosmological probes may indicate new physics extending beyond the standard cosmological model and need to be promptly identified. We apply several tension estimators proposed in the literature to the dark energy survey (DES) large-scale structure measurement and Planck cosmic microwave background data. We first evaluate the responsiveness of these metrics to an input tension artificially introduced between the two, using synthetic DES data. We then apply the metrics to the comparison of Planck and actual DES Year 1 data. We find that the parameter differences, Eigentension, and Suspiciousness metrics all yield similar results on both simulated and real data, while the Bayes ratio is inconsistent with the rest due to its dependence on the prior volume. Using these metrics, we calculate the tension between DES Year 1 3 × 2pt and Planck, finding the surveys to be in ∼2.3σ tension under the ΛCDM paradigm. This suite of metrics provides a toolset for robustly testing tensions in the DES Year 3 data and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Uranium Mill Tailings Radiation Control Act Title II DOE Due Diligence and Lessons Learned from a Previous Site Transfer - 20352

Title II of the Uranium Mill Tailings Radiation Control Act (UMTRCA) established that a government agency will provide perpetual care for closed uranium and thorium ore-processing sites that were operating under an NRC source material license in 1978 or were licensed thereafter. Commercial owners (licensees) operating under an NRC or agreement state specific license when UMTRCA was passed are responsible for conducting reclamation of any byproduct material remaining from uranium-ore processing operations in accordance with an NRC or agreement state approved reclamation plan. Reclamation includes both surface and groundwater remedies. Upon completion of reclamation and approval by NRC, the site is required to be transferred to either the host state or the DOE for long-term surveillance and maintenance. Since UMTRCA's enactment, six Title II sites have been transferred to DOE; an additional 24 Title II sites are anticipated to be transferred before 2050. DoE's role mandated under UMTRCA Title II as the long-term care custodian is to perform 'monitoring, maintenance, and emergency measures necessary to protect the public health and safety.' UMTRCA requires that the licensee pay a long-term surveillance charge 'sufficient to cover the annual costs of site surveillance.' However, at some sites such as the Bluewater, New Mexico, Disposal Site, this mandate has required additional effort and expense by DOE, beyond the originally anticipated and intended scope within UMTRCA, but within the authority of DOE under UMTRCA. In 1997, the Bluewater site became the second UMTRCA Title II site to be transferred to DOE. The site was the location of a uranium mill operated from 1953 until 1982. The specific licensee began site reclamation in 1991, and by 1995 all tailings and contaminated materials were encapsulated in two tailings disposal cells and other disposal areas. In addition to surface contamination, milling activities impacted groundwater in the two upper aquifers. In 1989, the specific licensee attempted active groundwater remediation; however, no significant reduction in contaminant concentrations was observed. As a result, the specific licensee applied to NRC for alternate concentration limits (ACLs) in 1990, which were approved in 1996 as being protective, after additional corrective actions were performed. Since transfer of the Bluewater site to DOE, unforeseen challenges have occurred, requiring additional actions. The first challenge is the occurrence of surface depressions located on the northern section of the main tailings disposal cell. The depressions were first observed during DoE's initial inspection in 1998; however, evidence of these can be observed on satellite images taken prior to transfer. Since being first observed, the depressions have continued to grow both in depth and areal extent. Due to the design of the main tailings disposal cell, the depressions impede storm water from being effectively shed off the 101- hectare (250-acre) top slope of the main tailings disposal cell. Instead, storm water accumulates in the depressions, forming a large ephemeral pond that has stored up to 16.3 x 10{sup 6} liters (4.3 million gallons) of stormwater. The ponding poses a potential risk to the integrity of the main tailings disposal cell in the case of a large storm event, with the potential to cause the pond to overtop and erode the cover material and underlying waste. DOE has taken a number of short-term actions to monitor, measure, and reduce the ponding and is currently working with the US Army Corps of Engineers to design and construct a repair. Additional challenges are associated with groundwater at the Bluewater site. Nine wells were present on the 1335-hectare (3300-acre) site upon transfer. Groundwater compliance was called into question after the State of New Mexico reduced its uranium groundwater standard from 5.0 to 0.03 milligrams per liter in 2004, and when an ACL for uranium was exceeded in a site monitoring well in 2010. Acquiring historical groundwater data and subsequent evaluations as well as additional DOE groundwater monitoring led to installing 10 new monitoring wells and performing additional site hydrogeology recharacterization. DOE continues to evaluate groundwater conditions at the site and works with the NRC to determine regulatory requirements and a path forward. As a result of lessons learned at the Bluewater site and other Title II sites, improved processes have been implemented at a programmatic level to increase due diligence before site transfer and prevent similar issues from occurring at other UMTRCA Title II sites under long-term management. DoE's due diligence process is documented in the Process for Transition of UMTRCA Title II Disposal Sites to DOE for Long-Term Surveillance and Maintenance and is designed to ensure that DOE has no technical or compliance concerns with regulatory decisions that might compromise protectiveness following site transfer to DOE. Implementation of the due diligence process has increased DoE's role prior to site transfer and has been effective in identifying potential issues. Actions by NRC and specific licensees, in response to enhanced due diligence efforts by DOE, are expected to minimize, if not totally prevent, the need for unanticipated actions by DOE pertaining to the surface and groundwater remedies after site transfer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗