A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating radioactive negative ion production via double electron capture

The relative cross sections for radioactive negative ion production via double electron capture have been measured for collisions between a 40 keV projectile beam of uranium-238 and potassium vapor. This was performed at the collinear resonance ionization spectroscopy (CRIS) experiment at CERN-ISOLDE and is a step towards measuring the electron affinities (EAs) of elements that cannot be efficiently produced in negative ion sources at radioactive ion beam (RIB) facilities. This includes short-lived radioactive isotopes that have low production quantities and heavy and superheavy elements that systematically have smaller EAs than work functions of available ion source materials. Negative ions are particularly sensitive to electron–electron correlation effects, which make such studies ideal for benchmarking atomic structure models that go beyond the independent particle model. While the EAs of most light elements have been measured, experimental investigations on heavier elements, namely the actinides, remain scarce due to their radioactive nature and production difficulty. By developing negative ion production by charge exchange, we aim to make these studies feasible at RIB facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SEDONA SpEctroscopic Detection Of Nerve Agents

Although the threat of a liquid explosive attack on a passenger aircraft has been mitigated by limiting the size of carry-on bottles, highly potent chemicals (e.g., nerve agents) are a very serious threat. A single travel bottle full of such chemicals would cause great harm to many people and create a national security incident disrupting civilian air travel. Current screening methods to detect highly potent chemicals require opening a closed bottle. Experts at Los Alamos National Laboratory have developed SEDONA, a low magnetic field nuclear magnetic resonance (NMR) to detect chemical threats through unopened bottles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2022 MB3a Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated an updated version of the MB3a infrasound sensor, designed by CEA and manufactured by SeismoWave. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The MB3a infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Long-length Scintillating Fibers for Nuclear Waste Repositories (Conference Record)

This paper describes the fabrication, testing, and characterization of long-length, up to 50 m, scintillating fibers for the purpose of radiation monitoring in inaccessible radiological and nuclear waste repositories. The fabrication aspect was focused on ruggedizing the 1-mm diameter fiber and limiting external light interference for fibers. Testing and characterization were performed in a laboratory setting with radiation sources, a photosensor module and a multi-channel analyzer. Light attenuation was studied as a function of distance by analyzing both the spectrum and count rate. Additionally, the scintillating fibers were coupled to optical communication fibers (100 m) to extend the reach of the system. This paper also includes the optical spectrometry results from the sensitivity and response of the signal attenuation. Lastly, the paper covers the field testing of the scintillating fibers in a relevant environment.

47 - OTHER INSTRUMENTATION↗

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory

A recently completed LDRD project has provided a new facility at Sandia for testing effects of energetic neutrons on electronic components. 14 MeV neutrons are produced with a deuterium ion beam onto a thin-film tritide target. The goal of the project was to increase the neutron fluence to levels needed for radiation effects testing and qualification. This goal was achieved through two technical advances. First, a new multi-layer target concept was developed to reduce the rate of tritium loss from the target by isotope exchange, thereby reducing tritium usage and increasing target lifetime. The second advance was the construction of a new test chamber designed to maximize neutron flux at test locations. Together, these increased the available neutron fluence by several orders of magnitude. This new capability is being used in tests for Sandia nuclear weapon programs, evaluation of commercial parts such as highly-scaled CMOS SRAM lCs, and tests of new devices under development at Sandia such as lll-V HBTs, gallium nitride high-voltage diodes, and for fundamental studies of physical mechanisms of device failure.

36 MATERIALS SCIENCE↗