At least 235 records · Page 13

Performance of cross-flow turbines with varying blade materials and unsupported blade span

Cross-flow turbines could play a larger role in the diversification of the global energy supply if the impact of more cost-competitive design choices on performance and rotor dynamics was better understood. This study focuses on rotor performance and blade strain measurements while varying the following parameters: blade materials and blade free end length by changing strut support position. Towing tank experiments were performed with a modular 1-meter diameter cross-flow turbine consisting of three NACA 0018 blades with two support struts. One strut was fixed at the lower end of the turbine, while the second strut was adjustable, thereby changing the length of the free end. The blade materials tested were carbon, E-glass, and hollow E-glass fiber composites, in decreasing order of stiffness and cost. High-resolution distributed fiber optic sensors were embedded in two of the three rotor blades for each material and provided hundreds of strain measurements per blade. Turbine performance and blade strain were measured while varying tow speed and tip speed ratio. Performance tests were conducted at towing speeds sufficiently high for the performance to be independent of Reynolds number. E-glass blades and carbon blades performed similarly for the most rigid strut configurations. Higher strain was measured on the E-glass blades, and their performance was reduced for less rigid configurations compared to the carbon fiber blades. The performance of the highly deflective hollow E-glass blades was lower overall and became even more degraded for longer unsupported blade span. Furthermore, the results provide insight into the use of various blade materials in cross-flow turbines and guidance on allowable free end length for each material type.

16 TIDAL AND WAVE POWER↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗

Metabolites of Tobacco- and E-Cigarette-Related Nitrosamines Can Drive Cu 2+ -Mediated DNA Oxidation

Nitrosamine metabolites resulting from cigarette smoking and E-cigarette (E-cig) vaping cause DNA damage that can lead to genotoxicity. While DNA adducts of metabolites of nitrosamines 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and N-nitrosonornicotine (NNN) are well-known tobacco-related cancer biomarkers, only a few studies implicate NNN and NNK in DNA oxidation in humans. NNK and NNN were found in the urine of E-cigarette users who never smoked cigarettes. This paper proposes the first chemical pathways of DNA oxidation driven by NNK and NNN metabolites in redox reactions with Cu 2+ and NADPH leading to reactive oxygen species (ROS). A microfluidic array with thin films of DNA and metabolic enzymes that make metabolites of NNN and NNK in the presence of Cu 2+ and NADPH was used to estimate relative rates of DNA oxidation. Detection by electrochemiluminescence (ECL) employed a new ECL dye [Os(tpy-benz-COOH) 2 ] 2+ that is selective for and sensitive to the primary DNA oxidation product 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in DNA. Enzyme–DNA films on magnetic beads were used to produce nitrosamine metabolites that enter ROS-forming redox cycles with Cu 2+ and NADPH, and liquid chromatography–mass spectrometry (LC–MS) was used to quantify 8-oxodG and identify metabolites. ROS were detected by optical sensors. Metabolites of NNK and NNN + Cu 2+ + NADPH generated relatively high rates of DNA oxidation. Lung is the exposure route in smoking and vaping, human lung tissue contains Cu 2+ and NADPH, and lung microsomal enzymes gave the highest rates of DNA oxidation in this study. Furthermore, E-cigarette vapor contains 6-fold more copper than that in cigarette smoke, which could exacerbate DNA oxidation.

59 BASIC BIOLOGICAL SCIENCES↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-Driven Chemical Disorder in Glassy As 2 S 3 up to 14.7 GPa, Postdensification Effects, and Applications in Materials Design

A small difference in energy between homopolar and heteropolar bonds and the glass-forming ability of pure chalcogens leads to unexpected trends in densification mechanisms of glassy chalcogenides compared to vitreous oxides. Using high-precision compressibility measurements and in situ high-energy X-ray diffraction up to 14.7 GPa, we show herein a new densification route in a canonical glass As 2 S 3 . After the first reversible elastic step with a maximum pressure of 1.3 GPa, characterized by a strong reduction of voids and cavities, a significant bonding or chemical disorder is developed under higher pressure, reaching a saturation of 30% in the population of As-As bonds above 8-9 GPa. The pressure-driven chemical disorder is accompanied by a remarkable structural relaxation and a strongly diminished optical gap and determines structural, vibrational, and optical properties under and after cold compression. The decompressed recovered glass conserves a dark color and exhibits two relaxation processes: (a) fast (a few days) and (b) slow (months/years at room temperature). The enhanced refractive index of the recovered glass is promising for optical applications with improved functionalities. A nearly permanent red shift in optical absorption after decompression can be used in high-impact-force optical sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designed 2D protein crystals as dynamic molecular gatekeepers for a solid-state device

The sensitivity and responsiveness of living cells to environmental changes are enabled by dynamic protein structures, inspiring efforts to construct artificial supramolecular protein assemblies. However, despite their sophisticated structures, designed protein assemblies have yet to be incorporated into macroscale devices for real-life applications. We report a 2D crystalline protein assembly of C98/E57/E66 L-rhamnulose-1-phosphate aldolase ( CEE RhuA) that selectively blocks or passes molecular species when exposed to a chemical trigger. CEE RhuA crystals are engineered via cobalt(II) coordination bonds to undergo a coherent conformational change from a closed state (pore dimensions <1 nm) to an ajar state (pore dimensions ~4 nm) when exposed to an HCN(g) trigger. When layered onto a mesoporous silicon (pSi) photonic crystal optical sensor configured to detect HCN (g) , the 2D CEE RhuA crystal layer effectively blocks interferents that would otherwise result in a false positive signal. The 2D CEE RhuA crystal layer opens in selective response to low-ppm levels of HCN (g) , allowing analyte penetration into the pSi sensor layer for detection. These findings illustrate that designed protein assemblies can function as dynamic components of solid-state devices in non-aqueous environments.

36 MATERIALS SCIENCE↗

Rapid discovery and evolution of nanosensors containing fluorogenic amino acids

Binding-activated optical sensors are powerful tools for imaging, diagnostics, and biomolecular sensing. However, biosensor discovery is slow and requires tedious steps in rational design, screening, and characterization. Here we report on a platform that streamlines biosensor discovery and unlocks directed nanosensor evolution through genetically encodable fluorogenic amino acids (FgAAs). Building on the classical knowledge-based semisynthetic approach, we engineer ~15 kDa nanosensors that recognize specific proteins, peptides, and small molecules with up to 100-fold fluorescence increases and subsecond kinetics, allowing real-time and wash-free target sensing and live-cell bioimaging. An optimized genetic code expansion chemistry with FgAAs further enables rapid (~3 h) ribosomal nanosensor discovery via the cell-free translation of hundreds of candidates in parallel and directed nanosensor evolution with improved variant-specific sensitivities (up to ~250-fold) for SARS-CoV-2 antigens. Altogether, this platform could accelerate the discovery of fluorogenic nanosensors and pave the way to modify proteins with other non-standard functionalities for diverse applications.

Biosensors↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

The ion-gas-neutral interactions with surfaces-2 (IGNIS-2) facility for the study of plasma–material interactions

The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma–material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two <5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.

Instruments & Instrumentation↗

Graph Neural Networks for low-energy event classification & reconstruction in IceCube

IceCube, a cubic-kilometer array of optical sensors built to detect atmospheric and astrophysical neutrinos between 1 GeV and 1 PeV, is deployed 1.45 km to 2.45 km below the surface of the ice sheet at the South Pole. The classification and reconstruction of events from the in-ice detectors play a central role in the analysis of data from IceCube. Reconstructing and classifying events is a challenge due to the irregular detector geometry, inhomogeneous scattering and absorption of light in the ice and, below 100 GeV, the relatively low number of signal photons produced per event. To address this challenge, it is possible to represent IceCube events as point cloud graphs and use a Graph Neural Network (GNN) as the classification and reconstruction method. The GNN is capable of distinguishing neutrino events from cosmic-ray backgrounds, classifying different neutrino event types, and reconstructing the deposited energy, direction and interaction vertex. Based on simulation, we provide a comparison in the 1 GeV–100 GeV energy range to the current state-of-the-art maximum likelihood techniques used in current IceCube analyses, including the effects of known systematic uncertainties. For neutrino event classification, the GNN increases the signal efficiency by 18% at a fixed background rate, compared to current IceCube methods. Alternatively, the GNN offers a reduction of the background (i.e. false positive) rate by over a factor 8 (to below half a percent) at a fixed signal efficiency. For the reconstruction of energy, direction, and interaction vertex, the resolution improves by an average of 13%–20% compared to current maximum likelihood techniques in the energy range of 1 GeV–30 GeV. The GNN, when run on a GPU, is capable of processing IceCube events at a rate nearly double of the median IceCube trigger rate of 2.7 kHz, which opens the possibility of using low energy neutrinos in online searches for transient events.

47 OTHER INSTRUMENTATION↗

Observing fish interactions with marine energy turbines using acoustic cameras

Abstract Marine current energy converters such as tidal and riverine turbines have the potential to provide reliable, clean power. The risk of collision of fishes with marine energy turbines is not yet well understood, in part due to the challenges associated with observing fish at turbine sites. Turbidity and light availability can limit the effectiveness of optical sensors like video cameras, motivating the use of acoustic cameras for this task. However, challenges persist in collecting and interpreting data acquired from acoustic cameras. Given the limited number of turbine deployments to date, it is prudent to draw on the application of acoustic cameras to monitor fish in other scenarios. This article synthesizes their use for other fisheries applications to inform best practices and set realistic expectations for the results of acoustic camera monitoring at turbine sites. We discuss six key tasks performed with acoustic cameras: detecting objects, identifying objects as fish, counting fish, measuring fish, classifying fish taxonomically and analysing fish behavior. Specific challenges to monitoring fish at turbine sites are discussed. This article is intended to serve as a reference for researchers, regulators and marine energy developers on effective use of acoustic cameras to monitor fish at turbine sites. The studies detailed in this article provide evidence that, in some scenarios, acoustic cameras can be used to inform the risk of fish collision with marine energy turbines but doing so requires careful study design and data processing.

Cotter, Emma↗

Increased range and contrast in fog with circularly polarized imaging

Fogs, low lying clouds, and other highly scattering environments pose a challenge for many commercial and national security sensing systems. Current autonomous systems rely on optical sensors for navigation whose performance is degraded by highly scattering environments. In our previous simulation work, we have shown that polarized light can penetrate through a scattering environment such as fog. We have demonstrated that circularly polarized light maintains its initial polarization state better than linearly polarized light, even through large numbers of scattering events and thus ranges. This has recently been experimentally verified by other researchers. In this work, we present the design, construction, and testing of active polarization imagers at short-wave infrared and visible wavelengths. We explore multiple polarimetric configurations for the imagers, focusing on linear and circular polarization states. The polarized imagers were tested at the Sandia National Laboratories Fog Chamber under realistic fog conditions. Here, we show that active circular polarization imagers can increase range and contrast in fog better than linear polarization imagers. We show that when imaging typical road sign and safety retro-reflective films, circularly polarized imaging has enhanced contrast throughout most fog densities/ranges compared to linearly polarized imaging and can penetrate over 15 to 25 m into the fog beyond the range limit of linearly polarized imaging, with a strong dependence on the interaction of the polarization state with the target materials.

47 OTHER INSTRUMENTATION↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

mystic : software for autonomous discovery and design under uncertainty

Throughout the diverse range of science and engineering applications, there is a growing desire to develop computational methods that can reliably predict the behavior of complex systems. Specifically, there is a strategic need for tools that can robustly forecast the behavior of complex physical systems, where data may be high-dimensional, noisy, or sparse, and models of the system may be time-dependent or include uncertainty. We use mystic to build tools that leverage statistical learning, physics-informed learning, and active learning in the efficient generation of reliably predictive surrogates for complex physical systems. mystic is a robust, proven, open-source optimization and uncertainty quantification toolkit with over a decade of use in the design and optimization of neutron instrumentation, solar-powered drones, and gasguns, and in iterative tuning of models for Raman spectroscopy and elastoplastic materials strength. Recent developments have focused on automated learning of statistically robust surrogates under uncertainty, with applications in materials in extreme environments, nanostructures, materials simulations and strength models, and the failure of shielding under particle radiation. In 2020, McKerns demonstrated active learning of optimally robust surrogates with respect to new simulated data for molecular dynamics simulations of materials mixing in warm dense matter, and is currently applying active learning to the automated steering of particle accelerator beams and the optimal design and control of quantum optical sensor instrumentation.

42 ENGINEERING↗

Reduction of Iron (III) Oxide in Microwaves Toward Gasification Studies

The purpose of this study is to reduce hematite (Fe2O3) using hydrogen (H2), carbon monoxide (CO), and methane (CH4) gases using microwave irradiation. Conventional temperature programmed reduction of iron phase transformation under H2, CO, and CH4 agree with the literature. Furthermore, the activation energy for the iron phase transformation in a conventional reactor was in the order of H2>CO>CH4, suggesting that CH4 was the best reductant to initiate the reduction at a much lower temperature than CO, and CO was significantly better than H2 atmosphere. Due to the uneven temperature distribution, the apparent activation energy of microwave reduction under H2 was approximately 1/4th when compared to the conventional reduction in H2. X-ray diffraction (XRD) analysis showed a mixed oxide phase in microwave reduction as opposed to the clear phase transformation in conventional studies. To combat the temperature measurement issues in microwave studies, fiber optic sensors and Forward Looking InfraRed (FLIR) sensors were used to acquire the actual temperature distribution in the catalyst bed. Therefore, a reasonably accurate activation energy estimation was achieved in the catalyst bed. Combining these with the characterization and quantification of the different iron phases in microwave reduction will provide a blueprint for future microwave-assisted gasification studies.

Aireddy, Divakar Reddy↗

Main Shaft Bending Moment Analysis for a Gamesa G97 2-MW Wind Turbine

In a collaborative project between Siemens Gamesa Renewable Energy and the National Renewable Energy Laboratory (NREL), a cost-effective method to measure dynamic main shaft torque and the influence of non-torque loads was applied to the gearbox of the Gamesa G97 2-megawatt (MW) wind turbine at the NREL Flatirons Campus and verified through a field test campaign that took place in 2023. The method involved the installation of fiber-optic sensors on the ring gear of the gearbox. Additionally, traditional strain gauges and a rotary encoder were installed on the main shaft to measure mechanical torque and orthogonal bending moments. We compare the measured total main shaft bending moments from the field test campaign to those predicted by an updated OpenFAST model of the G97 wind turbine for similar environmental conditions. We also assessed the sensitivity of the predicted bending moment to varying levels of turbulence intensity, shear exponent, and yaw error.

17 WIND ENERGY↗