Search NASA⌕ Search

SEARCH · Search NASA

Results for “Object storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Recovery of Rare Earth Elements (REEs) from Coal Mine Drainage, Phase 2

Phase 1 research identified a two-step refining train, acid leaching of AMD precipitate feed followed by solvent extraction (SX), to produce a 2% TREE product. For the Phase 2 bench scale system, the objective was to get the acid leaching step to operate in batch-mode with sufficient storage capacity to feed an aqueous, enriched REE liquor to a pilot SX plant operating in continuous-mode at a feed rate capable of producing 3 g/hr 2% TREE. Important process variables included feed rate, extractant makeup, flowsheet configuration, and stripping conditions. Operating parameters were optimized through a feedback-capable SCADA system configured for the SX bench scale plant. These conditions were met and exceeded. TREE grades approaching 90% were produced while our Techno-Economic Assessment indicated highly favorable economic returns. The project led to the design of a pilot facility for producing roughly 500 kg/TREE/year. That plant is now in the procurement stage with constructed expected to begin in late 2020.

01 COAL, LIGNITE, AND PEAT↗

CSP Gen3: Liquid-Phase Pathway to SunShot

The United States Department of Energy (DOE) established the Concentrating Solar Power Generation 3 (CSP Gen3) program to promote the development of advanced CSP systems capable of producing electricity at a levelized cost of energy (LCOE) less than $60/MWh, based on criteria published in the CSP Gen3 Roadmap and a subsequent funding opportunity announcement (Gen3 FOA). This report documents the progress and potential of the “Liquid Pathway” to meet these objectives. The Liquid Pathway proposes the use of low-cost molten chloride salts for energy storage, mated with an operationally flexible solar receiver that employs liquid-metal sodium for heat capture and transfer to the storage salt. This approach leverages molten-salt technology from the current state-of-the-art CSP power towers embodied by plants such as Gemasolar, Crescent Dunes, Noor III, and the DEWA 700 CSP project. Furthermore, the design builds on the knowledge gained over decades of use of liquid-metal sodium as a high-temperature heat transfer fluid (HTF) in solar tests and nuclear-power applications. The commercial representation of the proposed Gen3 design incorporates a high-efficiency sodium receiver operating at ~740°C, with a liquid-liquid heat exchanger feeding a two-tank, molten-chloride salt storage system. Chloride salt is dispatched to a supercritical CO 2 (sCO 2 ) power cycle to provide electric power to the grid. The design integration is a conceptual match for the current sodium receiver → solar salt storage → steam-Rankine power cycle promoted by developer Vast Solar, which may facilitate commercial acceptance and development.

14 SOLAR ENERGY↗

Predeployment progress of the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a summary of the surface sampling activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. One goal of this testing is to collect defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion cracking (CISCC) research. Another goal is to provide data for the validation of computational fluid dynamics (CFD) based deposition modeling. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed CFD modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about the thermal-hydraulic behavior of horizontal dry cask storage systems. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer detailed quantification and composition of the deposited particulates from a realistic storage environment. Discussions of a potential host site for the Canister Deposition Field Demonstration (CDFD) are ongoing. Until a host site is chosen, testing of key CDFD hardware components including the heater assemblies, power skid, and remote data acquisition system will continue. Functional testing of the finalized heater assemblies and test apparatus started this fiscal year. These initial heater tests have shown the assemblies are performing within design specifications. Staged surface sampling of a mockup of a canister outside the AHSM on a transfer skid was also performed. Refinements to the sampling procedures and techniques were captured from observation of these activities and lessons-learned debriefs. These updated sampling procedures and techniques are planned to be tested again in the field using the mockup in order to assure personnel are using the most accurate and repeatable methods possible prior to deployment for actual CDFD testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Regional Assessment for the CO 2 Storage Potential in the Northern Niagaran Pinnacle Reef Trend

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the regional analysis of the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Northern Michigan as part of the MRCSP programs Regional Assessment goals. The goal of this task was to perform an initial assessment of the geologic storage capacity and injectivity of the Northern Fairway of Michigan’s Niagaran Reef Trend. This was achieved through three main objectives: 1) development of a reef atlas, 2) understanding the regional trends in geology, and 3) estimating CO 2 and CO 2 -EOR resources. Data collected across multiple subtasks were integrated into a mappable database that could be accessed from many of the leading software. The reef atlas was used to map the reefs and associated characteristics across the entire NNPRT. Several methodologies were explored to estimate the CO 2 and CO 2 -EOR resources across the trend which included three scenarios: 1) storage only using fluid substitution and volumetric estimations, 2) CO 2 -EOR which applied proximity analysis concepts and measured performance metrics from the Core Energy reefs to predict performance at all oil reefs, and 3) enhanced storage scenario which combined CO 2 -EOR with fluid substitution to represent maximized storage after completion of CO 2 -EOR.

01 COAL, LIGNITE, AND PEAT↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Maximizing energy efficiency in wastewater treatment plants: A data-driven approach for waste heat recovery and an economic analysis using Organic Rankine Cycle and thermal energy storage

Maximizing energy efficiency through waste heat recovery (WHR) processes is crucial for sustainable and ecofriendly operations across multiple industries, notably in wastewater treatment plants (WWTPs). This work proposes a comprehensive approach for assessing the WHR feasibility in WWTPs, structured in two main objectives. Firstly, an Artificial Neural Network (ANN) model is developed to accurately predict WHR based on operational data, including biogas temperature, biogas pressure, daily production in kWh, and WHR values in kWh th . The second objective focuses on economically evaluating the WHR feasibility based on the estimated WHR values obtained by the ANN model, and then realistically assessing the economic feasibility of integrating the Organic Rankine Cycle (ORC) and Seasonal Thermal Energy Storage (STES) systems. With an application to the As-Samra WWTP located in Jordan, the developed ANN model demonstrates promising results in the validation phase, with a root mean square error (RMSE) of 2206 kWh/day, a mean absolute error (MAE) of 1674 kWh/day, and an R-squared (R 2 ) value of 68%. On the other hand, the economic analysis reveals that an optimal ORC system of 412.14 kW e capacity yields a Net Present Value (NPV) of 2.09 million US dollars, a Levelized Cost of Energy (LCOE) of 0.0749 USD/kWh, a Payback Period (PBP) of 4.8 years, and annual revenues of 428 kUSD. This work also investigates the techno-economic feasibility of integrating ORC-STES. Results indicate that the LCOE and PBP are highly affected by the ORC's capital cost, and integrating STES increases the LCOE to 0.0824 USD/kWh, rendering its integration with ORC infeasible. In conclusion, this study aims to advance the understanding and application of WHR in WWTPs, paving the way for more efficient and sustainable practices in the field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic-environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed computational fluid dynamics modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about thermal-hydraulic behavior. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment. Functional testing of the finalized heater assemblies and test apparatus is set to begin in December 2022. The proposed delivery of the canisters to the host test site is June/July 2023, which is well ahead of when the AHSM installations would be completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MRCI - Final Technical Report

The objective of the Midwest Regional Carbon Initiative (MRCI) project was to implement a collaborative Regional Initiative to accelerate the deployment of carbon capture, utilization, and storage (CCUS) in the Midwest-Northeastern and Mid-Atlantic areas of the United States. This area encompasses a 20-state region with much of the country’s carbon dioxide (CO2) emissions. The MRCI project is co-led by Battelle Memorial Institute (Battelle) in Columbus, Ohio, and the Illinois State Geological Survey (ISGS) in Champaign, Illinois, and benefitted from the experience these organizations have acquired over the past 10-plus years leading two Department of Energy (DOE) Regional Carbon Sequestration Partnerships (RCSPs): the Midwestern Regional Carbon Sequestration Partnership (MRCSP), led by Battelle, and the Midwest Geologic Sequestration Consortium (MGSC), led by the ISGS.

CCS↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

toughio v1.2.2

TOUGH is a widely used general purpose numerical simulator designed for fluid and heat flows of multiphase, multicomponent fluid mixtures in porous and fractured media, which has been applied to many real-world problems such as underground geological storage, geothermal reservoir engineering or nuclear waste disposal, to name a few. `toughio` is a lightweight, object-oriented and vectorized Python library that aims to provide user-friendly routines to facilitate pre- and post-processing of a TOUGH simulation. Although its primary target is the latest version TOUGH3, `toughio` can also be used to read/write TOUGH2 input/output files. Currently, to the best of our knowledge, only PyTOUGH offers an exhaustive number of features to carry out a complete TOUGH simulation using a scripting language. `toughio` and PyTOUGH share the same objectives, yet with different approaches and philosophies. On the one hand, a PyTOUGH mesh is represented as a MULGRAPH geometry where elements can be unstructured horizontally but only layered vertically. It also checks that the model parameters are valid to ensure that a TOUGH simulation runs smoothly. On the other hand, although it provides basic meshing features, `toughio` mostly relies on common third-party softwares (e.g. Abaqus, FLAC3D, Gmsh, LaGriT) to generate the mesh by importing and converting it to a TOUGH mesh, which also conveniently facilitates the coupling of TOUGH with any other simulator that also supports the same mesh formats. Besides, `toughio` is designed to be just a TOUGH input and output file reader/writer. It assumes that the user knows what he is doing and does not verify the validity of the model parameters (`toughio` does verify the functional arguments).

Luu, Keurfon↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Assisted High-Temperature Reservoir Thermal Energy Storage Optimization: Numerical Modeling and Machine Learning Input and Output Files

This data set includes the numerical modeling input files and output files used to synthesize data, and the reduced-order machine learning models trained from the synthesized data for reservoir thermal energy storage site identification. In this study, a machine-learning-assisted computational framework is presented to identify High-Temperature Reservoir Thermal Energy Storage (HT-RTES) site with optimal performance metrics by combining physics-based simulation with stochastic hydrogeologic formation and thermal energy storage operation parameters, artificial neural network regression of the simulation data, and genetic algorithm-enabled multi-objective optimization. A doublet well configuration with a layered (aquitard-aquifer-aquitard) generic reservoir is simulated for cases of continuous operation and seasonal-cycle operation scenarios. Neural network-based surrogate models are developed for the two scenarios and applied to generate the Pareto fronts of the HT-RTES performance for four potential HT-RTES sites. The developed Pareto optimal solutions indicate the performance of HT-RTES is operation-scenario (i.e., fluid cycle) and reservoir-site dependent, and the performance metrics have competing effects for a given site and a given fluid cycle. The developed neural network models can be applied to identify suitable sites for HT-RTES, and the proposed framework sheds light on the design of resilient HT-RTES systems. All the simulations and the neural network model were done by Idaho National Laboratory. A detailed description of the work was reported in publication linked below.

15 GEOTHERMAL ENERGY↗

Application of Electromagnetic Methods for Reservoir Monitoring with Emphasis on Carbon Capture, Utilization, and Storage

The Controlled-Source ElectroMagnetic (CSEM) method provides crucial information about reservoir fluids and their spatial distribution. Carbon dioxide (CO2) storage, enhanced oil recovery (EOR), geothermal exploration, and lithium exploration are ideal applications for the CSEM method. The versatility of CSEM permits its customization to specific reservoir objectives by selecting the appropriate components of a multi-component system. To effectively tailor the CSEM approach, it is essential to determine whether the primary target reservoir is resistive or conductive. This task is relatively straightforward in CO2 monitoring, where the injected fluid is resistive. However, for scenarios involving brine-saturated (water-wet) or oil-wet (carbon capture, utilization, and storage—CCUS) reservoirs, consideration must also be given to conductive reservoir components. The optimization of data acquisition before the survey involves analyzing target parameters and the sensitivity of multi-component CSEM. This optimization process typically includes on-site noise measurements and 3D anisotropic modeling. Based on our experience, subsequent surveys tend to proceed smoothly, yielding robust measurements that align with scientific objectives. Other critical aspects to be considered are using magnetotelluric (MT) measurements to define the overall background resistivities and integrating real-time quality assurance during data acquisition with 3D modeling. This integration allows the fine tuning of acquisition parameters such as acquisition time and necessary repeats. As a result, data can be examined in real-time to assess subsurface information content while the acquisition is ongoing. Consequently, high-quality data sets are usually obtained for subsequent processing and initial interpretation with minimal user intervention. The implementation of sensitivity analysis during the inversion process plays a pivotal role in ensuring that the acquired data accurately respond to the target reservoirs’ expected depth range. To elucidate these concepts, we present an illustrative example from a CO2 storage site in North Dakota, USA, wherein the long-offset transient electromagnetic method (LOTEM), a variation of the CSEM method, and the MT method were utilized. This example showcases how surface measurements attain appropriately upscaled log-scale sensitivity. Furthermore, the sensitivity of the CSEM and MT methods was examined in other case histories, where the target reservoirs exhibited conductive properties, such as those encountered in enhanced oil recovery (EOR), geothermal, and lithium exploration applications. The same equipment specifications were utilized for CSEM and MT surveys across all case studies.

Barajas-Olalde, César↗

Life Cycle Assessment for Closed-Loop Pumped Hydropower Energy Storage in the United States

The federal government has initiated an aggressive set of policies to achieve a net-zero carbon emission goal for the electricity sector by 2050. As a result, rapid growth in deployment of renewable energy technologies is expected. Most commercially mature technologies are temporally variable and do not provide grid inertia, while renewable technologies with high projected deployment have intermittent generation methods. Energy storage technologies are needed to both dispatch power on-demand and help provide the needed grid inertia. Pumped storage hydro (PSH) is a well-established technology that has gained renewed interest in recent years offering energy-balancing, grid stability, control of electrical network frequency, and large-scale storage capacity. For widespread adoption of PSH, more information is needed regarding its current life cycle environmental impacts. The objective of this study is to perform a full life cycle assessment (LCA) of new closed-loop PSH in the U.S. The functional unit for this study is 1 kWh of electrical power delivered to the grid and the base case project lifetime is 80 years. The life cycle inventory for this project accounts for all material and energy flows associated with the green-field construction, operation, maintenance, and decommissioning of a closed-loop PSH plant in the U.S. Collected data represents a range of potential PSH specifications and geographic locations coming from all prospective closed-loop PSH installations in the U.S. with data available. In addition, existing PSH installations are used to provide assumptions for inventory inputs. Results presented will include the global warming potential (GWP IPCC 100a) and Energy Return on Investment (EROI) from our base case (average PSH installation) as well as from scenario analyses and model sensitivity. These results will be compared to the impacts from existing PSH sites and alternate storage technologies. Methods align with the assumptions and guidelines put in place by previous PSH LCAs to ensure an accurate comparison with the results from this report.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Grand challenges and opportunities in next-generation batteries and technologies

The development of advanced Li-ion batteries and technologies generally addresses one of four objectives: 1) create a higher volumetric energy density and/or specific energy/power, 2) impart intrinsically safer chemistry, 3) produce speedier charging, and 4) utilize less expensive batteries but with competitive/near-competitive performances. Certainly, other factors can play a role as well, dependent on the type of market targeted and the availability of global supplies; however, for widespread adoption, the above points/criteria remain salient. Li-ion is commercially well entrenched in industry for communication and transportation (EV) applications. Nowadays, slight iterations, mostly electrolyte-defined, are incrementally improving safety, cost, and cycle or calendar life. The last point, calendar life, is one that is often overlooked for very high-energy dense Li-ion batteries, because of their reactivity at higher charge (OCV conditions) and elevated temperatures. While cycle life is debated with respect to capacity/energy performance decline, attempts to re-purpose the battery itself or recycle the internal chemical constituents at end of life have considerably grown in the field. Hopefully, energy-neutral processes are also considered in the recycling loop. Nevertheless, the energy storage arena is quite large, and this pursuit hinges on pushing the field in one of many directions, toward loftier objectives. The pursuit of next-generation batteries and technologies must thus delve deeper into new and novel chemistry and electrochemistry to create a world with a neutral, carbon-free environment, and one that is solely sufficient on energy-producing renewables such as the Sun and wind-derived means. The application of electricity and chemistry within our world is thus a 21st century opus.

25 ENERGY STORAGE↗

Preliminary Test Design and Plan for a Canister Deposition Field Demonstration

This report provides a high-level test plan for deploying three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUHOMS Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.). The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or adapt in response to conflicting requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage systems in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small tensor product distributed active space (STP-DAS) framework for relativistic and non-relativistic multiconfiguration calculations: Scaling from 10 9 on a laptop to 10 12 determinants on a supercomputer

Despite the power and flexibility of configuration interaction (CI) based methods in computational chemistry, their broader application is limited by an exponential increase in both computational and storage requirements, particularly due to the substantial memory needed for excitation lists that are crucial for scalable parallel computing. Here, the objective of this work is to develop a new CI framework, namely, the small tensor product distributed active space (STP-DAS) framework, aimed at drastically reducing memory demands for extensive CI calculations on individual workstations or laptops, while simultaneously enhancing scalability for extensive parallel computing. Moreover, the STP-DAS framework can support various CI-based techniques, such as complete active space (CAS), restricted active space, generalized active space, multireference CI, and multireference perturbation theory, applicable to both relativistic (two- and four-component) and non-relativistic theories, thus extending the utility of CI methods in computational research. We conducted benchmark studies on a supercomputer to evaluate the storage needs, parallel scalability, and communication downtime using a realistic exact-two-component CASCI (X2C-CASCI) approach, covering a range of determinants from 10 9 to 10 12 . Additionally, we performed large X2C-CASCI calculations on a single laptop and examined how the STP-DAS partitioning affects performance.

Complete-active space self-consistent field↗