Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spin and occupation number entanglement of Dirac fields for noninertial observers

We investigate the Unruh effect on entanglement taking into account the spin degree of freedom of the Dirac field. We analyze spin Bell states in this setting, obtaining their entanglement dependence on the acceleration of one of the partners. Then, we consider simple analogs to the occupation number entangled state |00>+|11> but with spin quantum numbers for |11>. We show that, despite their apparent similitude, while the spinless case is always qubitxqubit, for the spin case acceleration produces a qubitxfour-level quantum system state. We also introduce a procedure to consistently erase the spin information from our setting preserving occupation numbers. We show how the maximally entangled state for occupation number emerges from our setting. We as well analyze its entanglement dependence on acceleration, obtaining greater entanglement degradation than in the spinless case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-Time Fine Grained Occupancy Estimation Using Depth Sensors on ARM Embedded Platforms

Occupancy estimation is an important primitive for a wide range of applications including building energy efficiency, safety, and security. In this paper, we explore the potential of using depth sensors to detect, estimate, identify, and track occupants in buildings. While depth sensors have been widely used for human detection and gesture recognition, computer vision algorithms are typically run on a powerful computer like XBOX or Intel R CoreTM i7 processor. In this work, we develop a prototype system called FORK using off-the-shelf components that performs the entire depth data processing on a cheaper and low power ARM processor in real-time. As ARM processors are extremely weak in running computer vision algorithms, FORK is designed to detect humans and track them in a very efficient way by leveraging a novel lightweight model based approach instead of traditional approaches based on histogram of oriented gradients (HOG) features. Unlike other camera based approaches, FORK is much less privacy invasive (even if the sensor is compromised). Based on a complete implementation, real-world deployment, and extensive evaluation at realistic scenarios, we observe that FORK achieves over 99% accuracy in real-time (4-9 FPS) in occupancy estimation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FORK: fine grained occupancy estimatoR using kinect on ARM embedded platforms

Occupancy estimation is very useful for a wide range of smart building applications including energy efficiency, safety, and security. In this demonstration, we present a novel solution called FORK, which uses a Kinect depth sensor for estimating occupancy in real-time. Unlike other camera-based solutions, FORK is much less privacy invasive (even if the sensor is compromised) and it does not require a powerful machine like a Microsoft XBOX or an Intel® Core™ i7 processor to process the depth data. Our system performs the entire depth data processing on a cheaper and lower-power ARM processor, in real-time. In order to do that, FORK uses a novel lightweight human model by leveraging anthropometric properties of human bodies for detecting individuals. We will show how FORK detects, tracks, and counts occupants accurately in real-time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Occupancy Sensors in LED Parking Lot and Garage Applications: Early Experiences

Occupancy sensor systems are gaining traction as an effective technological approach to reducing energy use in exterior commercial lighting applications. Done correctly, occupancy sensors can substantially enhance the savings from an already efficient lighting system. However, this technology is confronted by several potential challenges and pitfalls that can leave a significant amount of the prospective savings on the table. This report describes anecdotal experiences from field installations of occupancy sensor controlled light-emitting diode (LED) lighting at two parking structures and two parking lots. The relative levels of success at these installations reflect a marked range of potential outcomes: from an additional 76% in energy savings to virtually no additional savings. Several issues that influenced savings were encountered in these early stage installations and are detailed in the report. Ultimately, care must be taken in the design, selection, and commissioning of a sensor-controlled lighting installation, else the only guaranteed result may be its cost.

LED lighting↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Development and Field-Testing of a Study Protocol, including a Web-Based Occupant Survey Tool, for Use in Intervention Studies of Indoor Environmental Quality

We developed and pilot-tested an overall protocol for intervention studies to evaluate the effects of indoor environmental changes in office buildings on the health symptoms and comfort of occupants. The protocol includes a web-based survey to assess the occupant's responses, as well as specific features of study design and analysis. The pilot study, carried out on two similar floors in a single building, compared two types of ventilation system filter media. With support from the building's Facilities staff, the implementation of the filter change intervention went well. While the web-based survey tool worked well also, low overall response rates (21-34percent among the three work groups included) limited our ability to evaluate the filter intervention., The total number of questionnaires returned was low even though we extended the study from eight to ten weeks. Because another simultaneous study we conducted elsewhere using the same survey had a high response rate (>70percent), we conclude that the low response here resulted from issues specific to this pilot, including unexpected restrictions by some employing agencies on communication with occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

The Lawrence Berkeley National Laboratory (LBNL), the University of California Merced (UCM), and the United Technologies Research Center (UTRC) conducted field studies and modeling analyses in the Classroom and Office Building (COB) and the Science and Engineering Building (S&E) at the University of California, Merced. In the first year, of a planned multiyear project, our goal was to study the feasibility and efficacy of occupancy-based energy management. The first-year research goals were twofold. The first was to explore the likely energy savings if we know the number and location of building occupants in a typical commercial building. The second was to model and estimate people movement in a building. Our findings suggest that a 10-14percent reduction in HVAC energy consumption is possible over typical HVAC operating conditions when we know occupancy throughout the building. With the conclusion of the first-year tasks, we plan to review these results further before this group pursues follow-on funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Information Science in Occupational Safety Management

Approaches to information technology in occupational safety management at industrial enterprises are considered. Obstacles to such uses of information technology are noted. Available software and approaches to workplace automation for occupational safety specialists are reviewed. Analysis of the advantages and disadvantages of the available software permits selection of the optimal product for specific problems in occupational safety.

42 ENGINEERING↗

Motion tomography via occupation kernels

The goal of motion tomography is to recover a description of a vector flow field using measurements along the trajectory of a sensing unit. In this paper, we develop a predictor corrector algorithm designed to recover vector flow fields from trajectory data with the use of occupation kernels developed by Rosenfeld et al. [9,10]. Specifically, we use the occupation kernels as an adaptive basis; that is, the trajectories defining our occupation kernels are iteratively updated to improve the estimation in the next stage. Initial estimates are established, then under mild assumptions, such as relatively straight trajectories, convergence is proven using the Contraction Mapping Theorem. We then compare the developed method with the established method by Chang et al. [5] by defining a set of error metrics. Here, we found that for simulated data, where a ground truth is available, our method offers a marked improvement over [5]. For a real-world example, where ground truth is not available, our results are similar results to the established method.

97 MATHEMATICS AND COMPUTING↗

Optimization of Occupancy Based Demand Controlled Ventilation in Residences

Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Poster Abstract: Investigating Occupancy Profiles Using Convolutional Neural Networks: Preprint

In this paper, we implement a convolutional neural networks based autoencoder to investigate occupancy profiles. We use the American time use survey data, which contains 191,558 schedules with binary occupancy information. Our results suggest that the trained filters provide an important insight of occupancy profiles (i.e., dominant and distinct patterns), and the latent space compresses the profiles with representative information.

14 SOLAR ENERGY↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Summer outdoor temperature and occupational heat-related illnesses in Quebec (Canada)

Background: Predicted rise in global mean temperature and intensification of heat waves associated with climate change present an increasing challenge for occupational health and safety. Although important scientific knowledge has been gathered on the health effects of heat, very few studies have focused on quantifying the association between outdoor heat and mortality or morbidity among workers. Objective: To quantify the association between occupational heat-related illnesses and exposure to summer outdoor temperatures. Methods: We modeled 259 heat-related illnesses compensated by the Workers' Compensation Board of Quebec between May and September, from 1998 to 2010, with maximum daily summer outdoor temperatures in 16 health regions of Quebec (Canada) using generalized linear models with negative binomial distributions, and estimated the pooled effect sizes for all regions combined, by sex and age groups, and for different time lags with random-effect models for meta-analyses. Results: The mean daily compensation count was 0.13 for all regions of Quebec combined. The relationship between daily counts of compensations and maximum daily temperatures was log-linear; the pooled incidence rate ratio (IRR) of daily heat-related compensations per 1 °C increase in daily maximum temperatures was 1.419 (95% CI 1.326 to 1.520). Associations were similar for men and women and by age groups. Increases in daily maximum temperatures at lags 1 and 2 and for two and three-day lag averages were also associated with increases in daily counts of compensations (IRRs of 1.206 to 1.471 for every 1 °C increase in temperature). Conclusion: This study is the first to quantify the association between occupational heat-related illnesses and exposure to summer temperatures in Canada. The model (risk function) developed in this study could be useful to improve the assessment of future impacts of predicted summer outdoor temperatures on workers and vulnerable groups, particularly in colder temperate zones. - Highlights: • 259 heat-related compensated illnesses were modeled with ambient temperature • An overall risk ratio of 1.419 (95% CI 1.326–1.520) for every 1 °C increase was found • Risk estimates were similar for men and women and by large age groups. • There were little lag effects (IRRs of 1.206 to 1.471 for every 1 °C increase)

54 ENVIRONMENTAL SCIENCES↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Strain-Induced Anion-Site Occupancy in Perovskite Oxyfluoride Films

Anion ordering is a promising route to engineer physical properties in functional heteroanionic materials. A central challenge in the study of anion-ordered compounds lies in developing robust synthetic strategies to control anion occupation and in understanding the resultant implications for electronic structure. Here, we show that epitaxial strain induces preferential occupation of F and O on the anion sites in perovskite oxyfluorides SrMn O2.5-δ F γ films grown on different substrates. Under compressive strain, F tends to occupy the apical-like sites, which was revealed by F and O K-edge linearly polarized x-ray absorption spectroscopy and density functional theory calculations, resulting in an enhanced c-axis expansion. Under tensile strain, F tends to occupy the equatorial-like sites, enabling the longer Mn-F bonds to lie within the plane. The oxyfluoride films exhibit a significant orbital polarization of the 3d electrons, distinct F-site dependence to their valence band density of states, and an enhanced resistivity when F occupies the apical-like anion site compared to the equatorial-like site. By demonstrating a general strategy for inducing preferential anion-site occupancy in oxyfluoride perovskites, this work lays the foundation for future materials design and synthesis efforts that leverage this greater degree of atomic control to realize new polar or quasi-two-dimensional materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modulating coordinate site occupancy in high-entropy spinel electrocatalysts

High entropy spinel oxides provide a versatile platform for electrocatalysis because multiple metal cations can be incorporated into a single crystalline lattice, enabling tunable electronic structures. However, controlling how these cations distribute between tetrahedral and octahedral coordination sites remains a major challenge, limiting rational catalyst design. Here, we modulate cation coordination site occupancy between tetrahedral and octahedral sites in a Co–Fe–Cr–Mn–Ni framework by introducing a sixth cation (Zn, Ga, Mg, or Al) with distinct site preference energies. Using density functional theory, synchrotron X-ray absorption spectroscopy, and magnetic circular dichroism, we demonstrate that Zn preferentially occupies tetrahedral sites, driving increased octahedral occupancy of cobalt. This redistribution increases the population of octahedrally coordinated cobalt in mixed oxidation states, enhances electrical conductivity, and improves oxygen evolution reaction activity. Our findings establish coordination site occupancy as a critical design parameter, providing a strategic pathway for tailoring multicomponent spinel electrocatalysts with optimized performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗