At least 235 records · Page 13

Integrated millimeter-wave cavity electro-optic transduction

Emerging communications and computing technologies will rely ever-more on expanding the useful radio frequency spectrum into the millimeter-wave and terahertz frequency range. Both classical and quantum applications would benefit from advancing integration and incorporation of millimeter-wave and electro-optic technologies into common devices, such as modulators. Here we demonstrate an integrated triply-resonant, superconducting electro-optic transducer. Our design incorporates an on-chip 107 GHz niobium titanium nitride superconducting resonator, modulating a thin-film lithium niobate optical racetrack resonator operating at telecom wavelengths. We observe a maximum photon transduction efficiency of η OE ≈ 0.82 × 10 −6 and an average single-photon electro-optic interaction rate of g 0 /2π ≈ 0.7 kHz. We also present a study and analysis of the challenges associated with the design of integrated millimeter-wave resonators and propose possible solutions to these challenges. Our work paves the way for further advancements in resonant electro-optic technologies operating at millimeter-wave frequencies.

47 OTHER INSTRUMENTATION↗

Mode locking in an optomechanical cavity

Here, we experimentally study a fiber-based optical ring cavity integrated with a mechanical resonator mirror and an optical amplifier. The device exhibits a variety of intriguing nonlinear effects including synchronization and self-excited oscillation. Passively generated optical pulses are observed when the frequency of the optical ring cavity is tuned very close to the mechanical frequency of the suspended mirror. The optical power at the threshold of this process of mechanical mode locking is found to be related to quantum noise of the optical amplifier.

36 MATERIALS SCIENCE↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

An electro-optic resonant modulator for coherent optical communication

A resonant cavity electro-optic phase modulator has been designed and implemented to operate at a data rate of 10 Mbps. The modulator consists of an electro-optic crystal located in a highly resonant cavity. The cavity is electro-optically switched on and off resonance, and the phase dispersion near the cavity resonance provides the output phase modulation. The performance of the modulator was measured by first heterodyne detecting the signal to an intermediate frequency, and measuring the spectral characteristics using an RF spectrum analyzer. The measured phase shift is shown to be in good agreement with the theoretical predictions. Further theoretical analysis shows that the design of the modulator can be scaled to operate at 100 Mbps.

Robinson, D. L.↗

Optical response of a dual membrane active–passive optomechanical cavity

Highlights: • The optical response is determined by competition between photon-tunneling, two-phonon process, gain effect. • The photon-tunneling adjusts supermode frequency. • The absorption coefficient can exceed 1. • Not only realize fast/slow light but conversion between fast and slow light. We investigate a dual membrane active–passive cavity where each mechanical membrane individually quadratically coupled to passive and active cavities via two-phonon process. Due to the fact that in the quadratically coupled optomechanical system mean-field approximation fails, hence to analyze the system completely, we switch to a more generalized out of equilibrium approach, namely Keldysh Green’s functional approach. We calculate transmission rate using predetermined full retarded Green’s function, and then numerically examine the effect of the various parameters on the transmission coefficient and discuss the features and physical mechanism behind them in detail. On the basis of the optical responsivity we further extend our study to fast and slow light phenomenon. The results show that our proposed system can not only realize ultra-fast/ultra-slow light under proper choice of cavity parameters but also a realization of the conversion between fast and slow light and vice versa has also been pointed out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN↗

10-Mbps electro-optic resonant phase modulator

A resonant cavity electro-optic phase modulator has been designed and implemented to operate at a data rate of 10 Mbps. The modulator consists of an electro-optic crystal located in a highly resonant cavity. The cavity is electro-optically switched on and off resonance, and the phase dispersion near the cavity resonance provides the output phase modulation. The performance of the modulator was measured by first heterodyne-detecting the signal to an intermediate frequency and then measuring the spectral characteristics using an rf spectrum analyzer. The measured phase shift is shown to be in good agreement with the theoretical predictions. Further theoretical analysis shows that the design of the modulator can be scaled to operate at 100 Mbps.

Robinson, D. L.↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

In-Situ Measurements of Aerosol Optical Properties using New Cavity Ring-Down and Photoacoustics Instruments and Comparison with more Traditional Techniques

Carbonaceous species (BC and OC) are responsible for most of the absorption associated with aerosol particles. The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult aerosol properties to measure. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-ARC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Aerosol absorption coefficient is also measured by a photoacoustic (PA) instrument (DRI) that was operated on an aircraft for the first time during the DOE Aerosol Intensive Operating Period (IOP). This paper will report on measurements made with this new instrument and other in-situ instruments during two field recent field studies. The first field study was an airborne cam;oaign, the DOE Aerosol Intensive Operating Period flown in May, 2003 over northern Oklahoma. One of the main purposes of the IOP was to assess our ability to measure extinction and absorption coefficient in situ. This paper compares measurements of these aerosol optical properties made by the CRD, PA, nephelometer, and Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model. The second study was conducted in the Caldecott Tunnel, a heavily-used tunnel located north of San Francisco, Ca. The aerosol sampled in this study was characterized by fresh automobile and diesel exhaust. Measurements from Cadenza and from an aethalometer are presented. The aethalometer is a filter-based photometer and the infrared channel is calibrated to produce a measure of BC mass loading.

Strawa, A. W.↗

U.S. Air Force Research Laboratory's Need for Flow Physics and Control With Applications Involving Aero-Optics and Weapon Bay Cavities

To develop New Flow Control Techniques: a) Knowledge of the Flow Physics with and without control. b) How does Flow Control Effect Flow Physics (What Works to Optimize the Design?). c) Energy or Work Efficiency of the Control Technique (Cost - Risk - Benefit Analysis). d) Supportability, e.g. (size of equipment, computational power, power supply) (Allows Designer to include Flow Control in Plans).

Schmit, Ryan↗

Mid-infrared vertical cavity laser

Disclosed is an optically pumped vertical cavity laser structure operating in the mid-infrared region, which has demonstrated room-temperature continuous wave operation. This structure uses a periodic gain active region with type I quantum wells comprised of InGaAsSb, and barrier/cladding regions which provide strong hole confinement and substantial pump absorption. A preferred embodiment includes at least one wafer bonded GaAs-based mirror. Several preferred embodiments also include means for wavelength tuning of mid-IR VCLs as disclosed, including a MEMS-tuning element. This document also includes systems for optical spectroscopy using the VCL as disclosed, including systems for detection concentrations of industrial and environmentally important gases.

42 ENGINEERING↗

Mid-infrared vertical cavity laser

Disclosed is an optically pumped vertical cavity laser structure operating in the mid-infrared region, which has demonstrated room-temperature continuous wave operation. This structure uses a periodic gain active region with type I quantum wells comprised of InGaAsSb, and barrier/cladding regions which provide strong hole confinement and substantial pump absorption. A preferred embodiment includes at least one wafer bonded GaAs-based mirror. Several preferred embodiments also include means for wavelength tuning of mid-IR VCLs as disclosed, including a MEMS-tuning element. This document also includes systems for optical spectroscopy using the VCL as disclosed, including systems for detection concentrations of industrial and environmentally important gases.

Jayaraman, Vijaysekhar↗

Embrace the darkness: An experimental perspective on organic exciton–polaritons

Organic polaritonics has emerged as a captivating interdisciplinary field that marries the complexities of organic photophysics with the fundamental principles of quantum optics. By harnessing strong light–matter coupling in organic materials, exciton–polaritons offer unique opportunities for advanced device performance, including enhanced energy transport and low-threshold lasing, as well as new functionalities like polariton chemistry. In this review, we delve into the foundational principles of exciton–polaritons from an experimental perspective, highlighting the key states, processes, and timescales that govern polariton phenomena. Our review centers on the spectroscopy of exciton–polaritons. We overview the primary spectroscopic approaches that reveal polariton phenomena, and we discuss the challenges in disentangling polaritonic signatures from spectral artifacts. We discuss how organic materials, due to their complex photophysics and disordered nature, not only present challenges to the conventional polariton models but also provide opportunities for new physics, like manipulating dark electronic states. As the research field continues to grow, with increasingly complex materials and devices, this review serves as a valuable introductory guide for researchers navigating the intricate landscape of organic polaritonics.

36 MATERIALS SCIENCE↗

Wind Tunnel Test Results for Gas Flows Inside Axisymmetric Cavities on Cylindric Bodies with Nose Cones

Experimental test results of air flow inside and at the cylindrical cavity located on axisymmetric body are presented. These tests were conducted in the wind tunnel A-7 of Institute of Mechanics at Moscow State University. Pressure distribution along the cavities and optical measurements were obtained. Dependence of these characteristics of length of a cavity in the range: L/D = 0.5 - 14 and free stream Mach in the range: M(sub infinity) = 0.6 - 3.0 was determined. Flow structure inside the cavity, cause of flow regime change, separation zones geometry and others were studied. In particular, the flow modes of with open and closed separation zones are determined.

Shvets, A. L.↗

Investigation of the effect of structural defects from hydride precipitation on superconducting properties of high purity SRF cavity Nb using magneto-optical and electron imaging methods

Abstract Nb is an elemental superconductor with a critical temperature of 9.3 K and is widely used to fabricate superconducting radiofrequency (SRF) cavities for particle accelerators. However, microstructural defects in Nb, such as grain boundaries (GBs) and dislocations, can act as pinning centers for magnetic flux that can degrade SRF cavity performance. Hydrogen contamination is also detrimental to SRF cavity performance due to the formation of normal conducting hydrides during cool down. In this study, disc shaped Nb bi-crystals extracted from high-purity large-grain Nb slices were investigated to study the effects of GBs, hydrogen, and dislocations on superconducting properties. Grain orientation and GB misorientation were measured using Laue x-ray diffraction and electron backscattered diffraction (EBSD) analyses. Cryogenic magneto-optical imaging was used to directly observe magnetic flux penetration below T c = 9.3 K. Damage caused by low temperature precipitation of hydrides and their dissolution upon reheating after cryogenic cycles was examined using electron channeling contrast imaging, and EBSD. The relationships between hydride formation, dislocation content, GBs, cryo-cooling, heat treatment (HT), and flux penetration indicate that both GB character and hydrogen content affect magnetic flux penetration. Such flux penetration could be facilitated by dislocation structures and low angle GBs resulting from hydride precipitation and HT.

36 MATERIALS SCIENCE↗

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers↗

Electro-optic resonant phase modulator

An electro-optic resonant cavity is used to achieve phase modulation with lower driving voltages. Laser damage thresholds are inherently higher than with previously used integrated optics due to the utilization of bulk optics. Phase modulation is achieved at higher speeds with lower driving voltages than previously obtained with non-resonant electro-optic phase modulators. The instant scheme uses a data locking dither approach as opposed to the conventional sinusoidal locking schemes. In accordance with a disclosed embodiment, a resonant cavity modulator has been designed to operate at a data rate in excess of 100 megabits per sec. By carefully choosing the cavity finesse and its dimension, it is possible to control the pulse switching time to within 4 nano-sec. and to limit the required switching voltage to within 10 V. This cavity locking scheme can be applied by using only the random data sequence, and without the need of dithering of the cavity. Compared to waveguide modulators, the resonant cavity has a comparable modulating voltage requirement. Because of its bulk geometry, the resonant cavity modulator has the potential of accommodating higher throughput power. Mode matching into the bulk device is easier and typically can be achieved with higher efficiency. An additional control loop is incorporated into the modulator to maintain the cavity on resonance.

Chen, Chien-Chung↗