Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High luminescence plastic scintillators

A plastic scintillator includes a polymeric matrix comprising a primary fluorophore capable of forming an amorphous glass in its pure form. The primary fluorophore is also capable of generating luminescence in the presence of ionizing radiation and includes: a central species including silicon; a luminescent organic group bonded to the central species or to an optional organic linker group, the luminescent organic group including fluorene or an analog thereof; and the optional organic linker group, if present, is bonded to the central species and the luminescent organic group.

Myllenbeck, Nicholas↗

Hydrogels for isotopic neutron emitters and antineutrino detection and related detection systems and methods

Scintillation compositions comprising a gadolinium compound and a scintillation compound in a polymer matrix precursor. The scintillation compound comprises strontium diiodide, fac-tris(2-phenylpyridine)iridium (Ir(ppy)3), a quinine compound, or combinations thereof, or 2-(4-biphenylyl)-5 phenyl-1,3,4-oxadiazole (PBD), 2-(4-tert-butylphenyl)-5-(4-phenylphenyl)-1,3,4-oxadiazole (b-PBD), 2,5-diphenyl oxazole (PPO), 1,4-bis(5-phenyloxazol-2-yl) benzene (POPOP), or combinations thereof. Hydrogels comprising the gadolinium compound and scintillation compound in a polymer matrix are also disclosed, as are related systems and methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Surface Chemistry and Structure of Colloidal Lead Halide Perovskite Nanocrystals

Since the initial discovery of colloidal lead halide perovskite nanocrystals, there has been significant interest placed on these semiconductors because of their remarkable optoelectronic properties, including very high photoluminescence quantum yields, narrow size- and composition-tunable emission over a wide color gamut, defect tolerance, and suppressed blinking. These material attributes have made them attractive components for next-generation solar cells, light emitting diodes, low-threshold lasers, single photon emitters, and X-ray scintillators. While a great deal of research has gone into the various applications of colloidal lead halide perovskite nanocrystals, comparatively little work has focused on the fundamental surface chemistry of these materials. While the surface chemistry of colloidal semiconductor nanocrystals is generally affected by their particle morphology, surface stoichiometry, and organic ligands that contribute to the first coordination sphere of their surface atoms, these attributes are markedly different in lead halide perovskite nanocrystals because of their ionicity. Herein, emerging work on the surface chemistry of lead halide perovskite nanocrystals is highlighted, with a particular focus placed on the most-studied composition of CsPbBr 3 . We begin with an in-depth exploration of the native surface chemistry of as-prepared, 0-D cuboidal CsPbBr 3 nanocrystals, including an atomistic description of their surface termini, vacancies, and ionic bonding with ligands. We then proceed to discuss various post-synthetic surface treatments that have been developed to increase the photoluminescence quantum yields and stability of CsPbBr 3 nanocrystals, including the use of tetraalkylammonium bromides, metal bromides, zwitterions, and phosphonic acids, and how these various ligands are known to bind to the nanocrystal surface. To underscore the effect of post-synthetic surface treatments on the application of these materials, we focus on lead halide perovskite nanocrystal-based light emitting diodes, and the positive effect of various surface treatments on external quantum efficiencies. We also discuss the current state-of-the-art in the surface chemistry of 1-D nanowires and 2-D nanoplatelets of CsPbBr 3 , which are more quantum confined than the corresponding cuboidal nanocrystals but also generally possess a higher defect density because of their increased surface area-to-volume ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect-resistant plastic scintillation radiation detector compositions and fabrication methods

Scintillating plastics resistant to crazing and fogging, methods of making and using the same are disclosed. The scintillating plastics include: one or more primary polymers present in an amount ranging from about 40 wt % to about 95 wt %; one or more secondary polymers present in an amount ranging from about 1 wt % to about 60 wt %; and one or more fluors present in an amount ranging from about 0.1 wt % to about 50 wt %. Methods of making such plastics include: creating a homogenous mixture of precursor materials including primary polymer, secondary polymer, and fluor in the amounts set forth above; and polymerizing the homogenous mixture. Methods of using such plastics include: exposing the scintillating plastic to one or more extreme environmental conditions for a predetermined amount of time without generating crazing or fogging within the scintillating plastic. Various additional features and specific embodiments of these inventive concepts are also disclosed.

36 MATERIALS SCIENCE↗

The Path to Enlightenment: Progress and Opportunities in High Efficiency Halide Perovskite Light-Emitting Devices

Besides the flourishment in photovoltaics, halide perovskites hold great promise to compete with leading contenders among solution-processed emitters, such as organics and semiconductor colloidal nanocrystals, in the field of light emission. Halide perovskites exhibit outstanding optoelectronic properties, including high photoluminescence quantum yields, facile bandgap tunability, narrow emission line widths, and respectable carrier mobilities, promoting them to thrive in versatile light-emitting applications such as light-emitting diodes, lasers, X-ray scintillators, and circularly polarized light sources. Herein, we discuss the underlying physics of light emission in state-of-the-art perovskite light-emitting devices and focus on promising strategies for further improvement of device performance.

42 ENGINEERING↗

Twenty and thirty GHz millimeter wave experiments with the ATS-6 satellite

The ATS-6 millimeter wave experiment, provided the first direct measurements of 20 and 30 GHz earth-space links from an orbiting satellite. Studies at eleven locations in the continental United States were directed at an evaluation of rain attenuation effects, scintillations, depolarization, site diversity, coherence bandwidth, and analog and digital communications techniques. In addition to direct measurements on the 20 and 30 GHz links, methods of attenuation prediction with radars, rain gages, and radiometers were developed and compared with the directly measured attenuation. Initial data results of the ATS-6 millimeter wave experiment from the major participating organizations are presented.

Ippolito, L. J.↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Mild Hydrothermal Crystal Growth of Two Luminescing Uranyl Phosphates Exhibiting an Autunite-Type Sheet Structure

Two new layered uranyl phosphate compounds, K(UO 2 )PO 4 (H 2 O) 3 and Na(UO 2 )PO 4 (H 2 O) 1.52 , crystallizing in an autunite-type sheet structure, were successfully synthesized as both single-crystals and polycrystalline powders under mild hydrothermal conditions. The compound K(UO 2 )PO 4 (H 2 O) 3 crystallizes in the tetragonal crystal system with the space group P4/ncc, exhibiting lattice parameters of a = b = 6.99320(7) Å and c = 17.8389(3) Å. Similarly, Na(UO 2 )PO 4 (H 2 O) 1.52 also crystallizes in the tetragonal crystal system, however, in the space group P4/nmm and exhibits lattice parameters of a = b = 6.9787 Å and c = 8.6303(17) Å. Both compounds adopt layered structures, a characteristic feature of uranyl phosphates, and exhibit intense green fluorescence typical for uranyl-containing materials. As a result, the infrared spectroscopy, photoluminescence, and scintillation properties of these compounds were investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data analysis of the COMPTEL instrument on the NASA gamma ray observatory

The Compton imaging telescope (COMPTEL) on the Gamma Ray Observatory (GRO) is a wide field of view instrument. The coincidence measurement technique in two scintillation detector layers requires specific analysis methods. Straightforward event projection into the sky is impossible. Therefore, detector events are analyzed in a multi-dimensional dataspace using a gamma ray sky hypothesis convolved with the point spread function of the instrument in this dataspace. Background suppression and analysis techniques have important implications on the gamma ray source results for this background limited telescope. The COMPTEL collaboration applies a software system of analysis utilities, organized around a database management system. The use of this system for the assistance of guest investigators at the various collaboration sites and external sites is foreseen and allows different detail levels of cooperation with the COMPTEL institutes, dependent on the type of data to be studied.

Diehl, R.↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Simplified Method for the In Situ Collection and Laboratory Analysis of Cosmogenic Tracers (Sulfur-35 and Sodium-22) to Determine Residence Time Distributions and Water Ages

The use of cosmogenically produced sulfur-35 (T 1/2 = 87 days) and sodium-22 (T 1/2 = 2.6 years) as intrinsic tracers can provide valuable information on catchment hydrology, flow paths, and subsurface storage. A new and straightforward method was created to determine the activities of both 35 S and 22 Na in various water sources by pumping large volumes (up to 1000 L) of water through cation- and anion-exchange resin columns in the field to collect sodium and sulfate ions and simple chemistry in the lab. Samples are counted for 35 S using liquid scintillation counting (LSC) and for 22 Na via γ spectroscopy. Our novel in situ method provides faster sample throughput as well as better counting statistics and lower detection limits. Both methods were successfully applied at the Southern Sierra Critical Zone Observatory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Twenty and thirty GHz millimeter wave experiments with the ATS-6 satellite

Studies at 11 locations in the continental United States were directed at an evaluation of rain attenuation effects, scintillations, depolarization, site diversity, coherence bandwidth, and analog and digital communications techniques using the Applications Technology Satellite-6(ATS-6). In addition to direct measurements on the 20- and 30-GHz links, methods of attenuation prediction with radars, rain gages, and radiometers were developed and compared with the directly measured attenuation. Initial data results of the ATS-6 millimeter wave experiment were presented. The first section describes the experiment objectives, flight hardware, and modes of operation. The remaining six sections present papers prepared by the major participating organizations in the experiment. The papers present a comprehensive summary of the significant results of the initial 11 months of ATS-6 experiment measurements and related radiometric, radar, and radio-meteorology studies.

Ippolito, L. J.↗

In vitro Ca-45/++/ uptake and exchange by otoconial complexes in high and low K/+/Na/+/ fluids

Recently, data have been accumulating to indicate that saccular and utricular otoconial complexes of the gravity receptor organs are dynamic and interact constantly with their environment. This study investigates the possibility that the ionic composition of the surrounding fluid influences calcium ion binding and release, and explores the importance of the K(+)/Na(+) ratio. Two in-vitro methods were developed, the first of which employed artificial endolymph and perilymph while ionically balanced fluids in which only the K(+)/Na(+) was altered were used in the second. The ability of rat complexes to take up Ca-45(++) during incubation with these fluids was assessed using liquid scintillation spectrometry. In vitro uptake of Ca-45(++) was greater in fluids with a high K(+)/Na(+) ratio than in fluids in which the ratio was low. The ability of the complexes to take up Ca-45(++) appeared to decline with age.

Ross, M. D.↗