Multifunctional two-dimensional metal-organic frameworks for radionuclide sequestration and detection

Two lanthanide containing porous coordination polymers, [Ln2(bpdc)6(phen)2] · nH2O (1) and [Ln2(bpdc)6(terpy)2] · 3H2O (2) (Ln = either Pr, Nd or Sm-Dy); bpdc: 2,2'-bipyridine-5,5'-dicarboxylic acid, phen: 1,10-phenanthroline, and terpy: 2,2':6',2''-terpyridine, have been hydrothermally synthesized and structurally characterized by powder and single crystal X-ray diffraction. The crystallographic analyses reveal compounds 1 and 2 feature Ln3+ containing dimeric nodes that form a porous two-dimensional (2D) and non-porous three-dimensional (3D) framework, respectively. Each material is stable in aqueous media between pH 3-10 and exhibits modest thermal stability to ~400ºC. Notably, a portion of the phen and bpdc ligands in 1 can be removed thermally, without compromising the crystal structure, causing the surface area and pore volume to increase. The optical properties of 1 and 2 with Gd3+, Sm3+, Tb3+, and Eu3+ were explored in the solid-state using absorbance, fluorescence, and lifetime spectroscopies. The analyses reveal a complex blend of metal and ligand emission in the materials containing Sm3+ and Tb3+, while those featuring Eu3+ are dominated by intense metal-based emission. Compound 1 with Eu3+ displayed promise for the capture and detection of the uranyl cation, (UO2)2+, from aqueous media. In short, uranyl capture was observed at pH 4 and the adsorption thereof was detectable via vibrational and fluorescence spectroscopies and colorimetrically as the off-white color of 1 turned yellow with uptake. Finally, both 1 and 2 with Eu3+ produce bright red emission upon irradiation with Cu ka X-ray radiation (8.04 keV) and are candidate materials for applications in solid-state scintillation.

Surbella, Robert G.↗

Luminescence Quenching via Deep Defect States: A Recombination Pathway via Oxygen Vacancies in Ce-Doped YAG

Luminescence quenching via nonradiative recombination channels limits the efficiency of optical materials such as phosphors and scintillators and therefore has implications for conversion efficiency and device lifetimes. In materials such as Ce-doped yttrium aluminum garnet (YAG:Ce), quenching shows strong dependence on both temperature and activator concentration, limiting the fabrication of high-intensity white-light emitting diodes with high operating temperatures. Here, we reveal by means of first-principles calculations an efficient recombination mechanism in YAG:Ce that involves oxygen vacancies and gives rise to thermally activated concentration quenching. We demonstrate that the key requirements for this mechanism to be active are localized states with strong electron-phonon coupling. These conditions are commonly found for intrinsic defects such as anion vacancies in wide band gap materials. The present findings are therefore relevant to a broad class of optical materials and shine light on thermal quenching mechanisms in general.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Ensemble Simulations and Experimental Free Energy Distributions: Evaluation and Characterization of Isoxazole Amides as SMYD3 Inhibitors

Optimization of binding affinities for ligands to their target protein is a primary objective in rational drug discovery. Herein, we report on a collaborative study that evaluates various compounds designed to bind to the SET and MYND domain-containing protein 3 (SMYD3). SMYD3 is a histone methyltransferase and plays an important role in transcriptional regulation in cell proliferation, cell cycle, and human carcinogenesis. Experimental measurements using the scintillation proximity assay show that the distributions of binding free energies from a large number of independent measurements exhibit non-normal properties. We use ESMACS (enhanced sampling of molecular dynamics with approximation of continuum solvent) and TIES (thermodynamic integration with enhanced sampling) protocols to predict the binding free energies and to provide a detailed chemical insight into the nature of ligand-protein binding. Our results show that the 1-trajectory ESMACS protocol works well for the set of ligands studied here. Although one unexplained outlier exists, we obtain excellent statistical ranking across the set of compounds from the ESMACS protocol and good agreement between calculations and experiments for the relative binding free energies from the TIES protocol. ESMACS and TIES are again found to be powerful protocols for the accurate comparison of the binding free energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the optical properties and toxicological profile of zinc tungstate nanorods

Zinc tungstate is a semiconductor known for its favorable photocatalytic, photoluminescence, and scintillation properties, coupled with its relatively low cost, reduced toxicity, and high stability in biological and catalytic environments. In particular, zinc tungstate evinces scintillation properties, namely the ability to emit visible light upon absorption of energetic radiation such as x rays, which has led to applications not only as radiation detectors but also for biomedical applications involving the delivery of optical light to deep tissue, such as photodynamic therapy and optogenetics. Here, we report on the synthesis of zinc tungstate nanorods generated via an optimized but facile method, which allows for synthetic control over the aspect ratio of the as-synthesized anisotropic motifs via rational variation of the solution pH. Additionally, we investigate the effect of aspect ratio on their resulting photoluminescent and radioluminescent properties. We further demonstrate the potential of these zinc tungstate nanorods for biomedical applications, such as photodynamic therapy for cancer treatment, by analyzing their toxicological profile within cell lines and neurons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eutectic Processing of Semiconductor Colloidal Nanocrystals for Energy Applications

Colloidal semiconductor nanocrystals (NCs) offer a costeffective platform for light-energy conversion in X-ray scintillators, photovoltaics, lasers, and display technologies. Yet, device-relevant NCs often require complex heterostructured compositions, where lattice imperfections compromise the efficiency and stability of photoconversion processes. Here, we show that a simple synthetic detour through a eutectic state of II−VI semiconductor NCs (e.g., CdSe, ZnSe) with halide salts (e.g., CdCl 2 , ZnCl 2 ) overcomes this limitation by melting and reconstructing NC lattices into defect-free alloyed and core/shell architectures. Applied to ternary CdSeTe NCs, this process produces downconverters with record brightness and minimal line widths, delivering a 3-fold increase in film-side external quantum efficiency of commercial CdTe photovoltaic modules (First Solar Inc.). Meanwhile, eutectic processing of CdSe-based core/shell emitters yields an 8-fold enhancement in their photoluminescence stability under backlight operation, addressing the reliability bottleneck for display technologies. Together, these findings establish eutectic NC processing as a scalable route to efficient, durable photoconversion materials for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Measurement of Missing Energy due to Nuclear Effects in Monoenergetic Neutrino Charged-Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from 𝐾 + → 𝜇 + ⁢𝜈 𝜇 decay at rest (𝐸 𝜈 𝜇 = 235.5 MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly 𝜈 𝜇 ⁢𝑛 → 𝜇 − ⁢𝑝 or 𝜈 𝜇 ⁢ 12 C → 𝜇 − ⁢ 12 N, we define the missing energy as the energy transferred to the nucleus (𝜔) minus the kinetic energy of the outgoing proton(s), 𝐸 𝑚 ≡ 𝜔−∑ 𝑇 𝑝 , and relate this to visible energy in the detector, 𝐸 𝑚 = 𝐸 𝜈 𝜇 ⁡(235.5 MeV) − 𝑚 𝜇⁡ (105.7 MeV) + [𝑚 𝑛 − 𝑚 𝑝⁡ (1.3 MeV)] − 𝐸 vis . The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g., nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a (77 ± 3)% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements, and Type-II supernova studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling light signals using data from the first pulsed neutron source program at the DUNE vertical drift ColdBox test facility at the CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN Neutrino Platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. We demonstrate the ability to identify the contribution from neutron interactions using X-ARAPUCA photodetectors, and show first comparisons of data to simulation, which indicate reasonable agreement. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and simulation. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

Detector modelling and simulations I (interaction ↗