Search NASA⌕ Search

SEARCH · Search NASA

Results for “Outage optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

222 records · Page 13

Mars Planetary Network for Human Exploration Era – Potential Challenges and Solutions

During 2016-2017, a study was conducted under the sponsorship of the NASA’s Space Communications and Navigation (SCaN) Program to investigate the deep space communications capacity taking into account the needs of all the present and envisioned future missions toward 2030s. It was soon recognized that planning for human exploration to Mars would impose certain unprecedent challenges, both fiscal and technical, to the current space communications paradigm. Targeting the assumed missions concepts, i.e., Crewed Mission to Phobos (CMTP) and Mars Short Stay Mission (MSSM), a Mars Planetary Network for the human exploration era has been formulated. The activity modeling and network traffic simulation/modeling we performed gave some insight into the technical challenges in space communications for the envisioned human Mars exploration era. Chief among the potential challenges are: (1) the high demand on the deep space network (DSN) assets for achieving the high-rate links, both return and forward, from Mars farthest/farther distance (up to 2.67 AU); (2) the need for resilient, persistent communication coverage for crewed vehicles, on surface and in orbits; (3) the significant period of outage for the Mars-Earth link due to superior solar conjunction; (4) the need for on-demand, simultaneous access to the proximity link by multiple vehicles and astronauts in the exploration zone; (5) the capability of determining precise, real-time, positions of surface vehicles and astronauts by the deep space habitat and/or other tele-operations entities. Solution space to each of the above challenges has been explored and analyzed in the context of the individual problem domain and, more importantly, in conjunction with that for the other challenges. This has led to an end-to-end definition of a Mars Planetary Network that would feature: (1) the fusion of deep space Ka-band and optical communications for achieving Mars-Earth high-rate links taking advantage of the optical/RF hybrid 8m/34m antennas in DSN; (2) the integrated application of the Multiple Spacecraft Per Antenna (MSPA) technique, for return link data acquisition, and the Multiple Uplink Per Antenna (MUPA) technique, for forward link data trasnmission, to reduce the number of 34m beam-wave guide (BWG) antennas needed for the era; (3) the integration of three, arrayed, 34m beam-wave guide (BWG) antennas, to provide a high G/T aperture, with the MSPA/MUPA techniques, and a dual “trunk link”approach to cut down the needed G/T -- hence, reducing the number of 34m antennas, relative to that in the single trunk approach by 50%; (4) the deployment of two areostationary/areosynchronous Mars relay orbiters; one of them could also function as (or be served by) a notional Deep Space Habitat (DSH); (5) the opportunistic deployment of a science orbiter in a Pioneer-6 type orbit, equidistant Mars/Earth, that could also serve as an intermediary relay during the Mars superior solar conjunction perod; (6) the existence of the multi-function Mars proximity link that provides the demand-assigned, multiple access (DAMA) capability; and (7) the provision of tracking observables, by leveraging on the planned Mars orbiting and surface infrastructure, to enable the in-situ navigation for surface and orbiting vehicles. This paper provides the description of the proposed Mars Planetary Network in the human exploration era, the trade-off analysis for the various alternative architectures, and the optimal solutions to the key challenges in defining this end-to-end network.

Cheung, Kar-Ming↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Process Anomaly Detection for Sparsely Labeled Events in Nuclear Power Plants

An essential aspect of online monitoring, subtle anomaly detection increases the detection lead time for equipment failure and enables a nuclear power plant (NPP) to mitigate unexpected partial or full outages, resulting in significant cost saving to the plant. Once an anomaly is detected by plant staff, its cause and severity are investigated. Because the vast majority of anomalies require some level of investigation, including some that require time-consuming examination, before they are passed over to the engineering organization for further analysis, plants are often equipped with tools to assist the staff in performing anomaly detection. Those tools operate as a black box and are often based on statistical methods that establish sensor correlations using preconfigured mathematical models and flag correlation deviations as anomalies. Due to the number of anomalies detected at a given NPP on a daily basis, a significant number of flagged anomalies usually await examination for days or weeks. A primary cause of this backlog is that the methods used by the tools generate many false positives. Though this is usually attributed to oversensitive model settings due to very narrow normal operation bands, it can also be associated with the model development being inadequate for the process being monitored, or with missing model inputs that could have explained misclassified positives. The performance of anomaly detection tools impacts their plant acceptance and utilization, especially when the effort to address false positives generated by the tool depletes the value or cost saved by using that tool. Thus, means to advance anomaly detection performance have been investigated by the Department of Energy’s Light Water Reactor Sustainability program. Previous and ongoing efforts have targeted unsupervised machine-learning (ML) methods, which do not require the labeling of any data fed into the ML model. By contrast, in supervised anomaly detection methods, every data point is labeled as either a normal or abnormal process condition, and the model is trained to replicate the classification process. Supervised methods usually outperform unsupervised methods, due to the added value in differentiating normal from anomalous states of the monitored process. An NPP’s corrective action program requires it to track and document, via a dedicated report, the resolution of any issues that occur within the plant. Once created, each report is reviewed by a plant screening committee, and several classifications and decisions are made. Recently, a collaborating NPP developed an artificial intelligence and ML-based classifier to categorize a condition report (CR) into classes that can serve to label the data as normal or anomalous. Applying CRs as labels represents a semi-supervised use case. Semi-supervised ML assumes that labels exist for some data points (i.e., labeled anomalies, in this case) but not for the rest. In this effort, semi-supervised ML methods were used to fuse data from CRs with anomaly detection methods in order to test the hypothesis that partially labeled anomalies would improve the accuracy of the anomaly detection methods. Specifically, two methods were used. The first is the deep Semi-supervised Anomaly Detection (deep SAD) method, which can handle labels ranging from fully unsupervised to fully supervised cases. The second is a newly designed ML method developed specifically for this effort and referred to as the high-order feature (HOF)-based method. To evaluate these two methods in controlled environments, synthetic data generators were developed and used. The first datasets used a spring-mass-damper (SMD) system simulator commonly found in mechanical engineering references. This was used to create two use cases: a one- and a three-mass system. Anomalies were introduced by changing the spring and damper coefficients while the system was actuated by random forces. The second datasets used the commercial Dymola-Modelica software to build a simplified nuclear reactor model. Anomalies were added in the form of corrupted sensor readings and/or control commands. The deep SAD method was tested using the SMD system, while the HOF method was tested using both datasets. Application of the deep SAD semi-supervised ML method demonstrated that labels can generate increased confidence in detecting true anomalies. This helped increase the number of true positives and decrease the number of false negatives—something that would aid in addressing the backlog of possible anomalies. Application of the HOF method demonstrated that labels can aid in down selecting from a candidate set of features to a more optimal subset in order to better differentiate between normal and anomalous conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗