Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERFORMANCE, ENGINEERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning prediction of self-diffusion in Lennard-Jones fluids

In this work, different machine learning (ML) methods were explored for the prediction of self-diffusion in Lennard-Jones (LJ) fluids. Using a database of diffusion constants obtained from the molecular dynamics simulation literature, multiple Random Forest (RF) and Artificial Neural Net (ANN) regression models were developed and characterized. The role and improved performance of feature engineering coupled to the RF model development was also addressed. The performance of these different ML models was evaluated by comparing the prediction error to an existing empirical relationship used to describe LJ fluid diffusion. It was found that the ANN regression models provided superior prediction of diffusion in comparison to the existing empirical relationships.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Manipulating the Crystallization Kinetics by Additive Engineering toward High-Efficient Photovoltaic Performance

Additive processing is proven to be an effective method to improve the efficiency and stability of perovskite solar cells; however, its intrinsic role in directing the crystallization pathway and thus morphology formation remains unknown. In situ grazing-incidence wide-angle x-ray scattering (GIWAXS) is applied to study the function of a 1,8-diiodooctane (DIO) additive in manipulating the crystallization behavior of perovskite thin films. It is seen that the DIO additive could induce multi-stage intermediate crystallization phases and increases the activation energy for nucleation and growth, which postpones the perovskite phase transformation time and broadens the transition zone. The elongated crystallization process affords improved perovskite thin film crystallinity and reduces defect density, which enables a longer carrier diffusion length. As a result, improved device efficiency, moisture, and thermal stability can be achieved. The following study provides a new prospective in understanding the additive function in perovskite thin film morphology control from fundamental parameters, indicating the importance of minor processing conditions in global property management toward high device performance.

36 MATERIALS SCIENCE↗

Doping engineering: Next step toward room temperature performance of terahertz quantum cascade lasers

We hereby offer a comprehensive analysis of various factors that could potentially enable terahertz quantum cascade lasers (THz QCLs) to achieve room temperature performance. We thoroughly examine and integrate the latest findings from recent studies in the field. Our work goes beyond a mere analysis; it represents a nuanced and comprehensive exploration of the intricate factors influencing the performance of THz QCLs. Through a comprehensive and holistic approach, we propose novel insights that significantly contribute to advancing strategies for improving the temperature performance of THz QCLs. This all-encompassing perspective allows us not only to present a synthesis of existing knowledge but also to offer a fresh and nuanced strategy to improve the temperature performance of THz QCLs. We draw new conclusions from prior works, demonstrating that the key to enhancing THz QCL temperature performance involves not only optimizing interface quality but also strategically managing doping density, its spatial distribution, and profile. This is based on our results from different structures, such as two experimentally demonstrated devices: the spit-well resonant-phonon and the two-well injector direct-phonon schemes for THz QCLs, which allow efficient isolation of the laser levels from excited and continuum states. In these schemes, the doping profile has a setback that lessens the overlap of the doped region with the active laser states. Our work stands as a valuable resource for researchers seeking to gain a deeper understanding of the evolving landscape of THz technology. Furthermore, we present a novel strategy for future endeavors, providing an enhanced framework for continued exploration in this dynamic field. This strategy should pave the way to potentially reach higher temperatures than the latest records reached for T max of THz QCLs.

47 OTHER INSTRUMENTATION↗

High-Performance Passivating Contacts for Si PV Based on Engineered, Doped Nanopinholes through Dielectric Layers

We present a novel, industrially relevant method to fabricate high-performance poly-Si passivating contacts for Si PV. Passivating contacts based on SiOx/poly-Si layer stacks have been implemented in record-efficiency homojunction Si solar cells. In this technology, the carrier transport through a surface-passivating SiOx is enabled either by quantum-tunneling or nanopinholes. The doped poly-Si layer provides charge-carrier selectivity. Previously, the ISFH research group demonstrated a record 26.1% efficient Si homojunction cell, where transport pinholes in ~2 nm SiOx were produced by thermal breakdown at > 1000 degrees C, which is hard to control and is surface morphology-dependent. At room temperature, our new process uses electroless plating of Ag nanoparticles, followed by metal-assisted chemical etching. Nanogalvanic corrosion yields < 20 nm-wide nanopinholes in an insulating > 2 nm SiOx layer. The nanopinholes are filled by a heavily doped a-Si:H overlayer. We drive in the dopants into the Si wafer with subsequent high-temperature annealing. Preferential incorporation of dopants at pinhole locations results in nanoscale p+/n or n+/n junctions near the wafer interface. Each heavily-doped nanoscale pinhole junction collects and transports photogenerated carriers to the cell metal contacts. The density of the engineered nanopinholes can be tuned over a wide range which is critical for optimization of device performance. The same nanogalvanic corrosion principles can be applied to produce doped transport pinholes in well-passivating thick dielectric SiOx/SiNy stacks. Importantly, our process does not rely on thermal breakdown of the dielectric layers and can be applied to textured wafers resulting in Si solar cells with > 20% conversion efficiency.

dielectric layer↗

HelioScope Energy Performance Modeling Validation: Cooperative Research and Development Final Report, CRADA Number CRD-17-00685

HelioScope is a unique solar design and energy performance modeling tool that bridges the worlds of research and industry, bringing the most rigorous methods from the performance modeling community to thousands of solar developers of all backgrounds. However, many financial institutions and municipalities are hesitant to accept the energy production modeling results of HelioScope (including shading losses) in place of costly, time-intensive, and/or redundant methods due to lack of vetting from a respected institution like NREL. We expect that the proposed validation exercises will give municipalities and financial institutions the comfort needed to incorporate HelioScope into their operations, thereby significantly reducing the needs of existing and potential HelioScope users' to otherwise obtain information that HelioScope produces automatically. Folsom Labs was selected for a Small Business Voucher from the U.S. Department of Energy for the National Renewable Energy Laboratory to validate the performance of HelioScope’s simulation engine against measured PV system performance.

14 SOLAR ENERGY↗

Hybrid electric vehicle and method of operating engine of the same

A hybrid electric vehicle (HEV) for multiple operation modes includes: a gasoline diffusion flame (GDF) combustion engine configured to perform gasoline diffusion flame combustion; a motor-generator operatively connected to the GDF combustion engine and configured to selectively drive the HEV with electric power of a battery or generate electric power to charge the battery; and a multi-mode controller including a processor and configured to receive operating conditions of the GDF combustion engine and the motor-generator and define a plurality of mode operating regions based on the received operating conditions. In particular, the plurality of mode operating regions includes: an electric vehicle (EV) only mode operating region, a GDF mode operating region where the GDF combustion engine operates and drives the HEV while the motor-generator stops, and a GDF+EV mode operating region where the motor-generator assists the operation of the GDF combustion engine to drive the HEV.

Bourcier, Mark↗

Effects of stratification and charge cooling on combustion in a gasoline direct-injection compression ignition (GDCI) engine

With the development of low temperature engine combustion strategies, performance of gasoline-type fuels under compression ignition conditions has attracted extensive research interest. Meanwhile, for the sake of co-optimization of engines and fuels for future ground transportation, identification and evaluation of general fuel properties should be a core research priority instead of endless testing of specific fuels. In this study, the roles of fuel octane sensitivity in characterizing the ignition performance of gasoline surrogates have been systematically investigated under typical gasoline direct ignition compression ignition (GDCI) engine conditions using 3D combustion CFD simulation, especially considering the subsequent in-cylinder charge stratification and charge cooling. Two different operating conditions, high boost pressure low boost temperature (beyond-RON) case and low boost pressure high boost temperature (beyond-MON) case, were considered. By comparing with our previous zero-dimensional chemical kinetic study of gasoline surrogates in advanced compression ignition (ACI) engines, the effects of stratification and charge cooling on the combustion processes are investigated. It is found that different fuel octane sensitivities lead to slight difference in equivalence ratio stratification and charge cooling due to differences in volatility. However, fuel reactivity is still the more dominant factor than the stratification and charge cooling effects in determining combustion phasing. The present results help to justify the P-T domain framework for engine autoignition analysis of overlapping pressure-temperature trajectory with ignition delay iso-contour. Here, the results also provide useful guidance to the understanding of GCI combustion process, and to the evaluation of controlling fuel properties and the selection of alternative fuels in GCI engines.

33 ADVANCED PROPULSION SYSTEMS↗

Demonstration and technoeconomic analysis of dodecanol production from acetate using metabolically engineered Escherichia coli

In a circular bioeconomy, the one-way conversion of petroleum to chemicals and CO 2 is replaced with processes that reduce CO 2 to energy carriers and useful materials that are returned to CO 2 upon combustion. A circular bioeconomy that relies on photosynthesis to generate sugars as the chief energy carrier and precursor to chemical building blocks has yet to overcome many recalcitrant aspects of plant-based photosynthesis, namely, high feedstock costs, arable land scarcity, food competition, and fertilizer overuse. Acetate is a potential sustainable energy carrier because it can be produced from CO 2 either electrocatalytically or by acetogens via the Wood-Ljungdahl pathway. Here, in this work, we conducted a metabolic engineering study of Escherichia coli 's ability to convert acetate into dodecanol as a model oleochemical product. We performed techno-economic and life cycle analyses to determine break-even points with alternative fossil fuel-based strategies and identified critical process performance parameters for supporting an industrial acetate-based bioprocess. These analyses showed that oleochemical yield is the primary driver of minimum oleochemical selling price and carbon intensity. Therefore, to increase yield on acetate, we deleted the aceBAK operon, which facilitates funneling of acetate into biomass instead of product. We performed additional strain engineering to increase flux towards dodecanol and increase acetate uptake. Finally, we demonstrated increased yield in controlled bioreactors, improving from 13% of the maximum theoretical yield to 37%. Rigorous uncertainty analyses assuming a range of market conditions and future technological performances resulted in 88% and 37% of simulated scenarios having lower carbon intensities than fossil fuel-based routes and lower minimum selling prices than the market price.

Acetate↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Multitude Characterization and Prediction of DOE Advanced Biofuels Properties

Advanced multitude of experiments ranging from the liquid fuel to combustion are conducted on Co-OPTIMA fuels to aid the characterization of the fuels. The series of targeted experiments characterized Co-OPTIMA fuel spray atomization, flame topology, flame speed, autoignition, volatility, viscosity, soot/coking, and compatibility. The fuels are selected and prioritized based on input from national lab members. The research characterized and predicted biomass-based, low greenhouse gas fuels and blends combustion, autoignition, and physical properties of mixtures of identified compounds at engine-relevant conditions, in particular those properties that blend non-linearly. The main challenge of Co-OPTIMA is the evaluation of a variety of biofuels and blends in all the reaction conditions that might be encountered in new high-efficiency engines. Despite the improved high-throughput experimental techniques, it seems unlikely that all of the performance metrics could be measured for all relevant petroleum derived, bio-derived molecules and mixtures, and reaction conditions. A series of targeted experiments ranging from the liquid fuel to the combustion process is required, and to extract the maximum information from each experiment. These targeted experiments evaluated how a specific fuel will perform in an engine. The series of targeted experiments are as follows: (a) Spray Atomization, Vaporization and Droplet Formation (b) Combustion Flame and Local Fuel/Air Image-Based Measurements (c) Laminar Flame Speed Measurements (d) Autoignition and Soot Measurements (e) Synchrotron Coupled Fundamental Autoignition Experiments (f) Fuel Coking and Hot Surface Deposit g) Fuel Volatility Measurements (h) Viscosity Measurements (i) Seal Flexible Fuel Compatibility These experimental processes provide an essential pathway for the prediction of fuel behaviors in engines and systematic process for fuel down select.

09 BIOMASS FUELS↗

Ducted fuel injection with Low-Net-Carbon fuels as a solution for meeting future emissions regulations

Several studies have proven how ducted fuel injection (DFI) reduces soot emissions for compression-ignition engines. Nevertheless, no comprehensive study has investigated how DFI performs over a load range in combination with low-net-carbon fuels. In this study, optical-engine experiments were performed with four different fuels—conventional diesel and three low-net-carbon fuels—at low and moderate load, to measure emissions levels and performance. The 1.7-liter single-cylinder optical engine was equipped with a high-speed camera to capture natural luminosity images of the combustion event. Conventional diesel and DFI combustion were investigated at four different dilution levels (to simulate exhaust-gas recirculation effects), from 14 to 21 mol% oxygen in the intake. At a given dilution level, with commercial diesel fuel, DFI reduced soot by 82% at medium load, and 75% at low load without increasing NO x . The results further show how DFI with dilution reduces soot and NO x without compromising engine performance or other emission types, especially when combined with low-net-carbon fuels. DFI with the oxygenated low-net-carbon blend HEA67 simultaneously reduced soot and NO x by as much as 93 % and 82 %, respectively, relative to conventional diesel combustion with commercial diesel fuel. These soot and NO x reductions occurred while lifecycle CO 2 was reduced by at least 70 % when using low-net-carbon fuels instead of conventional diesel. All emissions changes were compared with future emissions regulations for different vehicle sectors to investigate how DFI can be used to facilitate achievement of the regulations. Finally, the results show how the DFI cases fall below several future emissions regulation levels, rendering less need for aftertreatment systems and giving a possible lower cost of ownership.

33 ADVANCED PROPULSION SYSTEMS↗

Enhanced Performance of Silicon Anodes through Hybrid Surface Engineering

Silicon (Si) is a promising anode material for nextgeneration lithium-ion batteries (LIBs) due to its high theoretical capacity. However, Si-containing anodes typically suffer from unacceptably short lives because of the unrestricted growth of the solid electrolyte interphase (SEI). Here, in this study, hybrid surface coatings are developed to stabilize the SEI in high loading pure Si anodes using atomic and molecular layer deposition. The coatings, consisting of LiF paired with lithicone, create an ionically conductive surface that enhances the capacity retention, rate performance, and longevity. Careful binder selection helps demonstrate the full utility of the coatings by enabling high loading electrodes to cycle continuously at current densities of 1200 mA/g Si . Uncoated controls, in comparison, fail within just 10 cycles at lower loadings. X-ray photoelectron spectroscopy and electrochemical impedance spectroscopy are used to provide supporting evidence of the coating composition and efficacy. The data indicate that our lithicone coating is converted to Li 2 CO 3 upon cycling contributing to favorable LiF/Li 2 CO 3 interfaces that enhance the space-charge effect at the active material’s surface. When applied to electrodes made with thermally stable binders and increasingly higher loadings (approaching 5 mAh/cm 2 ), ion transport through the bulk electrode, rather than SEI growth, is shown to be the limiting factor. Furthermore, data suggests a favorable interaction between lithicone precursors and poly(acrylic acid) binders mitigates thermal decomposition at higher temperatures. The work presented here represents the successful realization of composite coatings containing LiF/Li 2 CO 3 components to stabilize high-loading Si anodes. This work helps inform advanced surface engineering strategies to achieve highly reversible, high-capacity Si anodes capable of fast charging for high-performance LIBs.

atomic layer deposition↗