Search NASASearch

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

QPSK loop lock detection in the advanced receiver

The Advanced Receiver (ARX 2) currently being developed uses a Costas crossover loop to acquire and track the phase of an incoming quadrature phase-shift-keyed (QPSK) signal. The performance is described for the QPSK lock detector to be implemented, taking into account the phase jitter in the tracking loop. Simulations are used to verify the results of the analysis.

Mileant, A.

Interferometer with Continuously Varying Path Length Measured in Wavelengths to the Reference Mirror

An interferometer in which the path length of the reference beam, measured in wavelengths, is continuously changing in sinusoidal fashion and the interference signal created by combining the measurement beam and the reference beam is processed in real time to obtain the physical distance along the measurement beam between the measured surface and a spatial reference frame such as the beam splitter. The processing involves analyzing the Fourier series of the intensity signal at one or more optical detectors in real time and using the time-domain multi-frequency harmonic signals to extract the phase information independently at each pixel position of one or more optical detectors and converting the phase information to distance information.

Ohara, Tetsuo

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast

Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process

Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd 3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd 3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd 3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd 3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd 3+ in different locations within the contactor system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Wide angle Michelson Doppler imaging interferometer

The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

Shepherd, G. G.

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.

Hybrid TLC-pair meter for the Sphinx Project

The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

Wada, T.

Fast Correction For Doppler In MDPSK Signals

Detector of multiple differential phase-shift-keyed (MDPSK) signals designed to effect combination of open-loop estimation of frequency and differential detection of digital modulation. Improved design expected to decrease probability of bit errors in situations in which carrier frequency uncertain and signals transmitted in bursts too short to allow closed-loop tracking of carrier frequency - for example, in transmission of digitally-coded voice signals in land-mobile/satellite communications at ultra-high frequencies.

Simon, M. K.

Effect Of Phase Unbalance In Product Modulator

Paper presents theoretical study of effect of phase unbalance in product modulator of phase-modulation transmitter in deep-space telemetry system upon performance of system. Mathematical model of product modulator used to derive equations for relative strengths of desired suppressed-carrier component and undesired residual-carrier component of transmitted signal. Also addresses effects of unsuppressed-carrier component on carrier-tracking phase-locked loop and bit detector in receiver.

Nguyen, Tien M.

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei

Absolute Distance Measurement with the MSTAR Sensor

The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

modulation sideband technology for absolute rangin

H20 Phase Characterization and Icing Mitigation Through Quantum Sensing in Silicon Carbide Non-Metal Defects

The primary focus of aircraft icing research has been on ice accretion on wings for its serious adverse consequences. When icing occurs on a wing, the change in airfoil shape results in a decrease in lift and an increase in drag, leading to potentially fatal accidents. Although the issue was recognized in the 1920s, the icing problem is still an area of ongoing research due to the complexity of the icing phenomena. A much-improved understanding of how certain weather conditions produce different icing characteristics will lead to new mitigation methods and a better quantification of current methods. This can be done by better understanding of the molecular bonding energy produced by ice polytype combinations when interacting with different surface materials in various environments. This work is currently developing both models that more accurately describe the quantum signatures of H2O states (i.e. supercooled, ice, liquid, glass phase...) and chip-based detectors to evaluate these signatures. These sensors utilize ion defects in Silicon Carbide (SiC) as extremely sensitive atomic magnetic detectors. This effort leverages both the decades-long SiC development expertise and infrastructure at NASA Glenn and its growing capabilities in quantum metrology.

Daniel R. Hart

Monolithic InSb imaging arrays with charge-coupled device /CCD/ readout

The paper demonstrates the detection of infrared radiation and signal readout on a monolithic InSb charge coupled infrared imaging device. The device is a 20-element linear imager with MOS detectors coupled to a four-phase, surface-channel, charge transfer structure. The charge transfer device is p-channel and has planar ion implanted diode structures for zero input and charge readout. Sensitivity measurements on the MOS infrared detectors were determined for the 20-element array. Data are presented on the operational characteristics of the 20-element linear imager under various conditions of electrical and optical inputs in both multiplexed and a time delay and integration (TDI) mode. Plans are discussed for a monolithic InSb 100-element linear imager and a 20 x 16 TDI linear imager.

Miller, W. E.

Design and Construction of the CMS Outer Tracker for the Phase-2 Upgrade

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000-4000~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about 5-7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger, for the first time at hadron colliders, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely spaced silicon sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments (stubs), used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), containing different sensor configurations and multiple ASICs. This contribution will present the design of the Phase-2 OT, the first results with pre-production devices, and the quality assurance procedures used to ensure the functionality of the modules: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication among the module's ASICs.

43 PARTICLE ACCELERATORS

Design and construction of the CMS Outer Tracker for the phase-2 upgrade

The High-Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000–4000 fb −1 over 10 years of operation with the peak instantaneous luminosity reaching about 5–7.5 × 1 0 34 cm −2 s −1 . During Long Shutdown 3, several components of the CMS detector will undergo major improvements, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have increased radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger for the first time at a hadron collider, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely-spaced silicon sensors read out by front-end ASICs that can correlate hits in the two sensors to create short track segments, used in the Level-1 track finder. The modules come in two flavors: strip-strip and pixel-strip, containing different sensor configurations and multiple ASICs. This contribution presents the Phase-2 OT, the finalization of the OT module design, and the quality assurance and control procedures used to ensure that the modules fulfill both the specifications from the assembly steps as well as the proper communication among the ASICs.

Zoi, Irene [Fermilab] (ORCID:0000000257389446)