Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Feasibility study for rocket ozone measurements in the 50 to 80 km region using a chemiluminescent technique

A study has been conducted to determine the feasibility of increasing sensitivity for ozone detection. The detection technique employed is the chemiluminescent reaction of ozone with a rhodamine-B impregnated disk. Previously achieved sensitivities are required to be increased by a factor of about 20 to permit measurements at altitudes of 80 km. Sensitivity was increased by using a more sensitive photomultiplier tube, by increasing the gas velocity past the disk, by different disk preparation techniques, and by using reflective coatings in the disk chamber and on the uncoated side of the glass disk. Reflective coatings provided the largest sensitivity increase. The sum of all these changes was a sensitivity increased by an estimated factor of 70, more than sufficient to permit measurement of ambient ozone concentrations at altitudes of 80 km.

Goodman, P.↗

Mossbauer spectrometer radiation detector

A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

Singh, J. J.↗

Feasibility test for a V-slit star mapper for pioneer spacecraft terminal navigation

A laboratory demonstration of the feasibility of using a V-slit star mapper to meet the sensitivity and accuracy of on-board navigational requirements for future Pioneer Missions to the outer planets was conducted by the Control and Sensors Laboratory of TRW. The breadboard was extremely simple in configuration, consisting of an end-on photomultiplier tube and a V-slit reticle located at the focal plane of the objective lens. In addition, a plano-convex lens was used between the reticle and the PMT in a Fabry-Perot configuration. The analytical effort indicated that the sensor should easily meet the requirements. The Pioneer SRA test set was examined to determine its basic accuracy and modify it where necessary to bring its accuracy into the 1-3 arc second range. The test results show that it is feasible to use this type of star mapper in the 10 arc second accuracy range. The test equipment accuracy (approximately 5 arc Sec) was sufficient to bound the sensor errors at less than 10 arc seconds.

Gates, R. F.↗

Improved integrated real-time contamination monitor

The laboratory model of the ITREM including the photomultiplier is described along with the utilization of the instrument. The preliminary designs are reviewed, and the development of the optical module for the instrument is discussed.

Source record↗

Transmission of radiometer data from the Synchronous Meteorological Satellite

The Synchronous Meteorological Satellite uses a spin scanner radiometer which generates eight visual signals and two infrared signals. These signals are multiplexed and converted into a 28-Mbps data stream. This signal is transmitted to ground by quadriphase modulation at 1686.1 MHz. On the ground, the digital signal is reconstructed to an analog signal. To conserve bandwidth, an analog-to-digital converter with a nonlinear transfer function was used for the visual signals. The size of the quantization step was made proportional to the noise output of the scanner photomultiplier tube which increases as the square root of incident light. The radiometer data transmission link was simulated on a digital computer to determine the transfer function. Some results of the simulation are shown.

Davies, R. S.↗

Processing of the laser Doppler velocimeter signals

The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

Meyers, J. F.↗

Use of channel electron multipliers as secondary standard detectors at EUV wavelengths

The procedures available for photometric calibration at extreme ultraviolet (EUV) wavelengths are outlined and the requirements for a secondary standard EUV photomultiplier defined. The performance of a number of commercially available channel electron multipliers over the 304-1350-A wavelength range is described, and their suitability for use as secondary standards is discussed in detail. Although none of the multipliers evaluated fully met the requirements for a secondary standard, it proved possible to calibrate absolutely a Mullard cone channel over the required wavelength range to an accuracy of plus or minus 9% and to employ it as a secondary standard in the calibration of a series of sounding rocket spectrometers.

Timothy, J. G.↗

Astronomical demonstration of an infrared upconverter

An upconverter has been used to convert infrared photons from astronomical sources to higher frequency quanta that were detected with a pulse-counting photomultiplier photometer. It is pointed out that these observations represent the first successful astronomical demonstration of infrared upconversion. Upconversion is carried out in an optically nonlinear medium, which in the upconverter described is a lithium iodate crystal. A 0.6943-micrometer high peak power ruby laser pump was developed for the demonstration.

Gurski, T. R.↗

Integrated laser/radar satellite ranging and tracking system

A laser satellite ranging system that is mounted upon and integrated with a microwave tracking radar is reported. The 1-pulse/sec ruby laser transmitter is attached directly to the radar's elevation axis and radiates through a new opening in the radar's parabolic dish. The laser photomultiplier tube receiver utilizes the radar's existing 20-cm diam f/11 boresight telescope and observes through a similar symmetrically located opening in the dish. The laser system possesses separate ranging system electronics but shares the radar's timing, computer, and data handling/recording systems. The basic concept of the laser/radar is outlined together with a listing of the numerous advantages over present singular laser range-finding systems. The developmental laser hardware is described along with preliminary range-finding results and expectations.

Hoge, F. E.↗

Photoreceiver efficiency measurements

The efficiency and other related parameters of Smithsonian Astrophysical Observatory's four laser receivers were measured at the observing stations by oscilloscope photography. If the efficiency is defined as the number of photoelectrons generated by the photomultiplier tube divided by the number of photons entering the aperture of the receiver, its measured value is about 1% for the laser wavelength of 694 nm. This value is consistent with the efficiency computed from the specified characteristics of the photoreceiver's optical components.

Lehr, C. G.↗

Gas threshold Cerenkov counters

The report describes two designs are reported of gas threshold Cerenkov counters for recording electrons of primary cosmic rays without recording protons. Also presented are design and technological measures which ensure maximum light collection of the Cerenkov radiation originating on the photocathode of the photomultiplier inside the radiator. The dependence of the reflection factor on the length of the light wave for different coatings is shown as well as for the throughput of the different optical materials employed. A range of methods for determining the efficiency of the counters during the recording of cosmic ray nucons and ways of increasing it further are given.

Logachev, V. I.↗

Plastic scintillation counters with an area of 2 sq m

Two designs of plastic scintillation counters with an area of 2 sq m scanned in each case by a single photomultiplier of the FEU-49 type are described. The radial dependence of their light collection at the place of the path of the detected particle does not exceed 10% while the half width of the differential distribution of the pulse amplitudes from nonfiltered cosmic radiation at sea level is 90 to 95%, and 65%, the plastic thickness being 5 cm and 10 cm, respectively. The temperature coefficient of the counter is 0.32% per 1 C.

Yegorov, T. A.↗

Development of a spectroscopic photoelectric imaging Fabry-Perot interferometer preliminary observational results

In order to observe extended astronomical objects at high spatial and spectral resolution, a spectroscopic photoelectric imaging Fabry-Perot interferometer was constructed. Among the properties chosen for the instrument are an air-spaced, piezoelectrically scanned design allowing an accurately settable free spectral range and employing a single etalon of high finesse. Careful design of the etalon mountings and optical train preserves high ligh throughput. Spectra of single spatial elements with a photomultiplier were obtained, and an SEC vidicon detector was used to record a series of images through the interferometer while scanning the wavelength in discrete steps. The latter procedure yields sufficient information to reconstruct spectral features over the entire object, and for the conditions assumed, either series of observations requires only a small fraction of a rotational period for Jupiter or Saturn. An electronic control system was also constructed which permits rapid and flexible variation of the operational mode of the Fabry-Perot and its ancilliary devices so as to minimize loss of observational time.

Smith, W. H.↗

Development of a laser fluorosensor for airborne surveying of the aquatic environment

A field based laser fluorosensor, employing a pulsed nitrogen laser and telescope photomultiplier detector system, has been successfully tested at night from a cliff top site overlooking Lake Ontario providing target ranges greater than 274 meters. Remotely sensed spectra and amplitude changes in the fluorescence emission of natural waters have shown potential as a water quality indicator. In this connection, a convenient internal reference standard with which to gauge the amplitude of the fluorescence signal is realized in the form of the concurrent water Raman emission. Remote measurements of oil fluorescence emission spectra suggest that airborne laser fluorosensors are capable of detecting and characterizing the oil in a given slick and that environmental aging of these slicks does not significantly alter their fluorescence emission signature.

Bristow, M. P. F.↗

A remote sensing laser fluorometer

A sensor is reported which is able to identify certain specific substances in water by means of their fluorescence spectra. In particular, the sensor detects oil, ligninsulfonates and chlorophyll. The device is able to measure the fluorescence spectra of water at ranges up to 75 m and to detect oil spills on water at altitudes up to 300 m. Blue light from a laser is used to excite the fluorescence of the target. Any light from the ambient background illumination, from the reflected laser light or from the induced fluorescence is gathered by a small telescope focused on the target. Optical filters are used to block the reflected laser light and to select the wavelengths of interest in the fluorescence spectrum of the target. The remaining light is detected with a photomultiplier tube. The amplitude of the laser induced fluorescence in the wavelength interval selected by the optical filters is displayed on a meter or strip chart recorder.

Oneill, R. A.↗

Asteroid observations and planetary atmospheres analysis

Photoelectric observations of Eros and 30 other asteroids providing information on their surface characteristics, shape, and rotation axes are reported. Photographs of 18 asteroids and 4 comets yielding accurate position information on various dates were obtained. Photometric observations were made of the Saturn satellite lapetus, and electronographic images of the Uranus and Neptune satellites were obtained experimentally with a Spectracon tube to assess photometry by that method. Planetary patrol photographs of Venus and deconvolved area scans of Uranus were taken. UBV photometry of the Galilean satellites for the period 1973-1974 was completely analyzed and accepted for publication. An improved magnitude and color index for Minas were derived from 1974 area scans. A special photomultiplier tube with a suppressor grid was incorporated into a pulse-counting photometer with special added circuitry for carrying out the observations concerning the constancy of solar system dimensions over cosmic time.

Baum, W. A.↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗