Specifying capacitors for performance and reliability in switching power supplies

The three most commonly used switching circuits are the full bridge converter, the half bridge converter, and the forward converter. All three circuits use the same pulse width concept for regulation with the major difference being how many transistors are used for power handling. The full bridge uses four transistors, the half bridge uses two, and the forward converter uses one. In practical design, forward converters are used at 300 watts and below, half bridges at 300 to 600 watts, and full bridges above 600 watts. Regulation is achieved by alternately saturating diagonal pairs of transistors in the full bridge, alternately saturating transistors in the half bridge, and simply pulse modulating one transistor in the forward converter.

Greenhalgh, F. E.↗

System and method of wireless power supply

A system and method for sensorless coil detection that exploits a dead-time effect in a WPT inverter as an indicator of presence of a receiver. In one embodiment, a system described herein may be configured to detect arrival of a moving receiver prior to alignment of the moving receiver with the transmitter for power transmission.

Kavimandan, Utkarsh D.↗

A multi-model assessment of global freshwater temperature and thermoelectric power supply under climate change

Water temperature is a key abiotic factor influencing aquatic ecosystem health and the services provided to both nature and humans. Global water temperature models offer possibilities to improve our understanding of water temperature regimes, which is increasingly important against the backdrop of climate change. Yet, existing studies have predominantly relied on a single model, which can lead to an incomplete representation of uncertainty and potential biases, in addition to limited insight into the range of possible future conditions, which ultimately reduces the robustness of climate impact assessments. Here, we provide a comprehensive assessment of surface freshwater temperature changes from various river and lake models for both past conditions and under future scenarios of climate change. Global models consistently simulate that surface water temperatures are currently 0.5 °C–0.8 °C higher than at the turn of the century (i.e. 1981–2000), and that warming will extend and intensify with future global change throughout the 21st century. While the strength of warming is highly sensitive to the different water temperature models, emissions scenarios and global climate models, our multi-model ensemble shows a global average annual water temperature rise of between +1.3 °C and +4.1 °C by the end of the century. To illustrate a potential societal impact of our results, we evaluate how future changes in discharge and water temperature may affect existing thermoelectric power plants, estimating average annual reductions of 1.5%–6% in global usable capacity by the end of the century. However, with river water temperatures projected to exhibit more pronounced seasonal patterns in the future—especially under the more extreme climate change scenarios and during summer months in the Northern Hemisphere—intra-annual reductions in usable capacity can be much more severe. Given the challenges associated with (large-scale) adaptation to control water temperature regimes, strong climate change mitigation is crucial for minimising water temperature rises and its associated negative impacts on humankind and ecosystems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synchronization and phase locking of resonant magnet power supplies for Mu2e experiment at Fermilab

The Mu2e Experiment has stringent beam structure requirements; namely, it requires short (~200 ns) proton bunches separated by 1.5-2.0 $\mu$s. This beam structure will be produced using the Fermilab 8 GeV Booster, the 8 GeV Recycler Ring, and the Delivery Ring, which was formerly part of the antiproton accumulator system. Out of time beam is limited to a fraction of level of no more than $1\times 10^{-10}$, a requirement known as "extinction". Achieving this level of extinction requires a system of resonant magnets and collimators, phased such that only in time particles will pass through. The Mu2e magnet system involves two components: a 300 kHz component, timed such that the 600 kHz beam will pass through the collimators at the nodes, and a 4.5 MHz system to reduce the slewing of the in-time beam. These two systems must be precisely phase locked to the bunch rate coming from the Delivery Ring, which itself must be phased to match beam transfers coming from the Recycler. This poster describes the control system for the magnets, which is based on an Intel Arria FPGA, which handles phase locking of the magnets to the Delivery Ring, including the phase jumps required to match transfers from the Recycler.

43 PARTICLE ACCELERATORS↗

Electron storage ring power supply system design report

In January 2020, U.S. Secretary of Energy Dan Brouillette announced the decision to build an Electron Ion Collider (EIC) at Brookhaven National Laboratory (BNL). While advancing the state of the art of particle colliders, the EIC will enable the U.S. nuclear physics community, with world wide participation, to take a giant step forward in the centuries-old quest to understand the nature of matter at its most fundamental level, providing the clearest picture yet of how the elemental quarks and gluons interact to form the basic structure of atoms and nuclei. The EIC at Brookhaven National Laboratory will be the first particle accelerator capable of colliding polarized ions with polarized electrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual-voltage power supply has increased efficiency

Simple circuit provides two different dc output voltages from an ac source. It employs a full-wave rectifier connected to two passive branches from which the separate dc voltages are taken. The outputs have low ripple and good voltage regulation.

Sturman, J. C.↗

Circuit protects regulated power supply against overload current

Sensing circuit in which a tunnel diode controls a series regulator transistor protects a low voltage transistorized dc regulator from damage by excessive load currents. When a fault occurs, the faulty circuit is limited to a preset percentage of the current when limiting first occurs.

Airth, H. B.↗