Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Blood pressure and plasma renin activity as predictors of orthostatic intolerance

The effect of 3 h standing, followed by a period of head-up tilt (HUT) on physiological response (orthostatic tolerance, blood pressure and heart rate), as well as on plasma vasopressin (PVP) and renin activity (PRA) were studied in 13 dehydrated (to 2.4 pct loss of body weight) subjects. Seven subjects showed signs of orthostatic intolerance (INT), manifested by sweating, pallor, nausea and dizziness. Prior to these symptoms, the INT subjects exhibited lower systolic (SP) and pulse (PP) pressures, and an elevated PRA, compared to the tolerant (TOL) subjects. HUT has aggravated increases of RPA in the INT subjects and caused an increase, higher than in TOL subjects, in PVP, while rehydration has greatly attenuated the PVP response to the HUT and decreased the PRA response. It is concluded that dehydration, together with measurements of SP, PP and PRA, may serve as a means of predicting orthostatic intolerance and may provide a physiological model for studying the causes of intolerance.

Harrison, M. H.↗

Exploration Atmosphere Demonstration of A Multi-Functional Integrated Medical Device (Tempus Pro)

INTRODUCTION The Exploration Medical Capability (ExMC) element within the Human Research Program and the Exploration Medical Integrated Product Team (XMIPT) within the Mars Campaign Office seek to advance medical system design and risk-informed decision-making for exploration missions. This includes assessment of candidate devices and their compatibility within a variety of increasingly Earth-independent medical scenarios. The Tempus Pro (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf (COTS), multi-functional integrated medical device capable of vital signs monitoring, with built-in procedure support (iAssist), patient record and telemedicine communication features, and medical imaging (e.g., camera, laryngoscope, ultrasound) that meets multiple exploration medical capability needs. One of several hypobaric atmospheres being considered for exploration vehicles is 8.2 psi with 34% oxygen. To assess the useability of the Tempus Pro in such environments by individuals without formal medical training, the unit was tested in May and June of 2023 at the Johnson Space Center 20-Foot Exploration Atmosphere Chamber in conjunction with the Exploration Atmospheres-2 (EA-2) study. TECHNOLOGY DEMONSTRATION Eight subjects in the EA-2 study were assigned roles as the caregiver or patient – or both in the case of a self-exam – and caregivers were asked to place sensors for 3-Lead ECG, non-invasive blood pressure (NIBP), pulse oximetry (SpO2), and temperature using Tempus Pro’s iAssist. Depending on the procedure, additional tasks included an oropharyngeal exam of the throat with the laryngoscope and capturing ultrasound images of a cardiac subxiphoid view or of the user’s choice from a pre-specified list. Scenarios ranged from remote-guided to fully autonomous operations and surveyed the effectiveness of support, amount of support desired, and importance of support by type (e.g., written crew procedures, iAssist and device guidance, remote console guidance, etc.). Feedback from the subjects and the support personnel was also gathered to inform future designs for training and support and to determine what operations are plausible given different levels of each. An unweighted NASA task load index (TLX) was used to profile the demands of using the device, however the sample size does not support statistics. The research was exploratory in nature and qualitative information was the main goal. Calibration checks on the Tempus Pro were conducted before and after chamber testing to ensure the device was in useable condition. RESULTS All subjects performed their tasks successfully and found the Tempus Pro easy to use with the support provided. The calibration checks outside the chamber showed that the Tempus Pro remained unchanged and measurements inside the chamber were within normal values. Caregivers taking the NASA TLX reported mean scores ≤ 41/100 showing the tasks to be undemanding and less demanding with repeated use (~20/100). Novice users were able to easily connect sensors and take vital signs with the guidance from Tempus Pro’s iAssist feature. For more complex tasks, such as the oropharyngeal exam and ultrasound image acquisition, guidance beyond iAssist was needed, primarily from a supporting physician. Feedback on the importance of support types varied by person and scenario but greater than 50% of the support used by each was non-native to the device. Overall opinions were positive, but the ultrasound users expressed a lack of confidence in their results and 3 out of 4 desired more time, training, or support. Subjects found the sensors to be comfortable and comparable to prior experiences with such devices, except for the blood pressure cuff, which squeezed too tightly for uncomfortably long periods. Many observations provoked discussion, especially regarding ultrasound, that will aide decisions about future demonstrations.

R. S. Miller↗

Nonlinear vibrations of rectangular plates.

A finite-difference method is developed to determine the large amplitude dynamic responses of thin elastic plates subjected to uniform pressure pulse-type loads. Four different sets of boundary conditions are considered. Some specific problems are solved. The results are compared with approximate solutions obtained by Yamaki (1961). The numerical method presented provides an accurate and efficient approximate solution to the problem, and should be useful as a check on other approximate methods. The grid-size and the time-step necessary for obtaining numerical stability depend on the particular problem. For many cases the method converges rapidly and a rather large grid-size and time-step is adequate.

Bayles, D. J.↗

Low-background trace-gas detector

Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.

Rosengren, L.↗

Basic results of the medical research conducted during the flight of two crews on the Salyut-5 orbital station

The study of the effect of space factors, especially weightlessness, on man, taking into account prophylactic measures and devices to counteract that effect was part of the program for two flights on the Salyut 5 orbital station. Information from the equipment on board was transmitted telemetrically including: an electrocardiogram; a sphygmogram of carotid and femoral arteries; a kinetocardiogram; a tacho-oscillogram of the humeral artery, perimetric oscillations of the femur, venous pulse and pressure in the jugular veins, vital capacity of the lungs, respiration rate and lung ventilation. Stress factors, metabolism, biological and bacteriological and other tests were included. A comparison was made between these data and pre- and postflight test result.

Source record↗

Development of tunable high pressure CO2 laser for lidar measurements of pollutants and wind velocities

The problem of laser energy extraction at a tunable monochromatic frequency from an energetic high pressure CO2 pulsed laser plasma, for application to remote sensing of atmospheric pollutants by Differential Absorption Lidar (DIAL) and of wind velocities by Doppler Lidar, was investigated. The energy extraction principle analyzed is based on transient injection locking (TIL) at a tunable frequency. Several critical experiments for high gain power amplification by TIL are presented.

Levine, J. S.↗

Spectra from nuclear-excited plasmas

The paper discusses the spectra taken from He-3(n,p)H-3 nuclear-induced plasmas under high thermal neutron flux, lasing conditions. Also, initial spectra are presented for U-235F6 generated plasmas. From an evaluation of these spectra, important atomic and molecular processes that occur in the plasma can be inferred. The spectra presented are the first to be generated by He-3 and U-235F6 nuclear reactions under high neutron flux, lasing conditions. The U-235(n,ff)FF reaction, which liberates 165 MeV of fission-fragment kinetic energy, creates plasmas that are of great interest, since at sufficiently high densities of U-235F6 the gas becomes self-critical; thus, there is no need for an external driving reactor (source of neutrons). The spectra from mixtures of He-3 and Ar, Xe, Kr, Ne, Cl2, F2 and N2 indicate little difference between high-pressure nuclear-induced plasmas and high-pressure electrically pulsed afterglow plasmas for noble-gas systems

De Young, R. J.↗

Ways of increasing muscular activity by means of isometric muscular exertion

The effect of isometric muscular exertion on the human body was investigated by having subjects perform basic movements in a sitting position in the conventional manner with additional muscle tension at 50% maximum force and at maximum force. The pulse, arterial pressure, skin temperature, respiratory rate, minute respiratory volume and electrical activity of the muscles involved were all measured. Performance of the exercises with maximum muscular exertion for 20 sec and without movement resulted in the greatest shifts in these indices; in the conventional manner substantial changes did not occur; and with isometric muscular exertion with 50% maximum force with and without movement, optimal functional shifts resulted. The latter is recommended for use in industrial exercises for the prevention of hypodynamia. Ten exercises are suggested.

Kovalik, A. V.↗

Fiber-Optic Pressure Sensor With Dynamic Demodulation Developed

Researchers at the NASA Glenn Research Center developed in-house a method to detect pressure fluctuations using a fiber-optic sensor and dynamic signal processing. This work was in support of the Intelligent Systems Controls and Operations project under NASA's Information Technology Base Research Program. We constructed an optical pressure sensor by attaching a fiber-optic Bragg grating to a flexible membrane and then adhering the membrane to one end of a small cylinder. The other end of the cylinder was left open and exposed to pressure variations from a pulsed air jet. These pressure variations flexed the membrane, inducing a strain in the fiber-optic grating. This strain was read out optically with a dynamic spectrometer to record changes in the wavelength of light reflected from the grating. The dynamic spectrometer was built in-house to detect very small wavelength shifts induced by the pressure fluctuations. The spectrometer is an unbalanced interferometer specifically designed for maximum sensitivity to wavelength shifts. An optimum pathlength difference, which was determined empirically, resulted in a 14-percent sensitivity improvement over theoretically predicted path-length differences. This difference is suspected to be from uncertainty about the spectral power difference of the signal reflected from the Bragg grating. The figure shows the output of the dynamic spectrometer as the sensor was exposed to a nominally 2-kPa peak-to-peak square-wave pressure fluctuation. Good tracking, sensitivity, and signal-to-noise ratios are evident even though the sensor was constructed as a proof-of-concept and was not optimized in any way. Therefore the fiber-optic Bragg grating, which is normally considered a good candidate as a strain or temperature sensor, also has been shown to be a good candidate for a dynamic pressure sensor.

Lekki, John D.↗

Cleaning devices

Cleaning devices are described which include a vacuum cleaner nozzle with a sharp rim for directing incoming air down against the floor; a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes; a vacuum cleaner head having slots that form a pair of counter-rotating vortices, and that includes an outlet that blows a stream of air at the floor region which lies between the vortices; a cleaning device that sweeps a group of brushes against the ground along a first direction, and then sweeps them along the same ground area but in a second direction angled from the first by an amount such as 90.degree., to sweep up particles lying in crevices extending along any direction; a device that gently cleans a surface to remove bacteria for analysis, including an inclined wall along which cleaning fluid flows onto the surface, a vacuum chamber for drawing in the cleaning fluid, and a dividing wall spaced slightly from the surface to separate the fluid source from the vacuum cleaner chamber; and a device for providing pulses of pressured air including a chamber to which pressured air is supplied, a ball that circulates around the chamber to repeatedly close an outlet, and an air source that directs air circumferentially to move the ball around the chamber.

Schneider, Horst W.↗

NASA Propulsion Sub-System Concept Studies and Risk Reduction Activities for Resource Prospector Lander

NASA's exploration roadmap is focused on developing technologies and performing precursor missions to advance the state of the art for eventual human missions to Mars. One of the key components of this roadmap is various robotic missions to Near-Earth Objects, the Moon, and Mars to fill in some of the strategic knowledge gaps. The Resource Prospector (RP) project is one of these robotic precursor activities in the roadmap. RP is a multi-center and multi-institution project to investigate the polar regions of the Moon in search of volatiles. The mission is rated Class D and is approximately 10 days, assuming a five day direct Earth to Moon transfer. Because of the mission cost constraint, a trade study of the propulsion concepts was conducted with a focus on available low-cost hardware for reducing cost in development, while technical risk, system mass, and technology advancement requirements were also taken into consideration. The propulsion system for the lander is composed of a braking stage providing a high thrust to match the lander's velocity with the lunar surface and a lander stage performing the final lunar descent. For the braking stage, liquid oxygen (LOX) and liquid methane (LCH4) propulsion systems, derived from the Morpheus experimental lander, and storable bi-propellant systems, including the 4th stage Peacekeeper (PK) propulsion components and Space Shuttle orbital maneuvering engine (OME), and a solid motor were considered for the study. For the lander stage, the trade study included miniaturized Divert Attitude Control System (DACS) thrusters (Missile Defense Agency (MDA) heritage), their enhanced thruster versions, ISE-100 and ISE-5, and commercial-off-the-shelf (COTS) hardware. The lowest cost configuration of using the solid motor and the PK components while meeting the requirements was selected. The reference concept of the lander is shown in Figure 1. In the current reference configuration, the solid stage is the primary provider of delta-V. It will generate 15,000-lbf of thrust with a single burn of ~ 80's seconds. The lander stage is a bi-propellant, pressure-regulated, pulsing liquid propulsion system to perform all other functions.

Trinh, Huu P.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗

Haemodynamic changes during neck pressure and suction in seated and supine positions

We sought to quantify the contribution of cardiac output (Q) and total vascular conductance (TVC) to carotid baroreflex-mediated changes in mean arterial pressure (MAP) in the upright seated and supine positions. Acute changes in carotid sinus transmural pressure were evoked using brief 5 s pulses of neck pressure and neck suction (NP/NS) via a simplified paired neck chamber that was developed to enable beat-to-beat measurements of stroke volume using pulse-doppler ultrasound. Percentage contributions of Q and TVC were achieved by calculating the predicted change in MAP during carotid baroreflex stimulation if only the individual changes in Q or TVC occurred and all other parameters remained at control values. All NP and NS stimuli from +40 to -80 Torr (+5.33 to -10.67 kPa) induced significant changes in Q and TVC in both the upright seated and supine positions (P < 0.001). Cardiopulmonary baroreceptor loading with the supine position appeared to cause a greater reliance on carotid baroreflex-mediated changes in Q. Nevertheless, in both the seated and supine positions the changes in MAP were primarily mediated by alterations in TVC (percentage contribution of TVC at the time-of-peak MAP, seated 95 +/- 13, supine 76 +/- 17 %). These data indicate that alterations in vasomotor activity are the primary means by which the carotid baroreflex regulates blood pressure during acute changes in carotid sinus transmural pressure.

Clinical Trial↗

Cusp/cleft auroral activity in relation to solar wind dynamic pressure, interplanetary magnetic field B(sub z) and B(sub y)

Continuous optical observations of cusp/cleft auroral activities within approximately equal to 09-15 MLT and 70-76 deg magnetic latitude are studied in relation to changes in solar wind dynamic pressure and interplanetary magnetic field (IMF) variability. The observed latitudinal movements of the cusp/cleft aurora in response to IMF B(sub z) changes may be explained as an effect of a variable magnetic field intensity in the outer dayside magnetosphere associated with the changing intensity of region 1 field-aligned currents and associated closure currents. Ground magnetic signatures related to such currents were observed in the present case (January 10, 1993). Strong, isolated enhancements in solar wind dynamic pressure (Delta p/p is greater than or equal to 0.5) gave rise to equatorward shifts of the cusp/cleft aurora, characteristic auroral transients, and distinct ground magnetic signatures of enhanced convection at cleft latitudes. A sequence of auroral events of approximately equal to 5-10 min recurrence time, moving eastward along the poleward boundary of the persistent cusp/cleft aurora in the approximately equal to 10-14 MLT sector, during negative IMF B(sub z) and B(sub y) conditions, were found to be correlated with brief pulses in solar wind dynamic pressure (0.1 is less than Delta p/p is less than 0.5). Simultaneous photometer observations from Ny Alesund, Svalbard, and Danmarkshavn, Greenland, show that the events often appeared on the prenoon side (approximately equal to 10-12 MLT), before moving into the postnoon sector in the case we study here, when IMF B(sub y) is less than 0. In other cases, similar auroral event sequences have been observed to move westward in the prenoon sector, during intervals of positive B(sub y). Thus a strong prenoon/postnoon asymmetry of event occurence and motion pattern related to the IMF B(sub y) polarity is observed. We find that this category of auroral event sequence is stimulated bursts of electron precipitation that originate from magnetosheath plasma that has accessed that dayside magnetosphere in the noon or near-noon sector, possibly at high latitudes, partly governed by the IMF orientation as well as by solar wind dynamic pressure pulses.

Sandholt, P. E.↗

Ultrasonic Observation of the Calcite-Aragonite Transition

Elastic-wave velocities were measured as a function of pressure by ultrasonic pulse Interferometry in Solenhofen and Manilus limestone specimens to pressures of 27 and 38 kb. Longitudinal velocities decrease sharply from 5.3 km/sec at a mean pressure of 4 kb to a minimum of 4.8 km/sec at 8 kb. Transverse velocities decrease from 3.1 to 2.9 km/sec. At the minimum bulk and rigidity moduli are 25 and 20 per cent below their 4-kb values. A density increase of 1.7 per cent is associated with this minimum. The observed effects are attributed to the calcite-aragonite transition, and they may be due to an inherent property of the material, a component of which undergoes a polymorphic transition, the low- and high-pressure phases coexisting over a considerable pressure range. This may be an additional mechanism to account for low-velocity zones in the earth?s interior.

POLYMORPHISM↗