Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRINTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Evolution of Dust in the Multiphase ISM: Grain Destruction Processes

This proposal covered year one of a long term project in which we acquired the necessary hardware and softwaxe needed to calculate grain destruction processes in the interstellar medium (ISM). The long term goal of this research is to develop a model for the dust evolution in the ISM capable of explaining observations of elemental depletions, the grain size distribution, and the emission characteristics of the ISM from the X-ray through the FIR. We purchased a SUN Ultra 10 workstation and peripheral devices including an Exabyte Tape drive, HP Laser Printer, and Seagate External Hard Disk. The PI installed the hardware and Solaris operating system on the workstation and integrated the hardware into the network. Software was also purchased to enable connections to the workstation from a PC (Hummingbird Exceed). Additional freeware required to carry out the proposed program was installed on the system including compilers (g77, gcc, g++), editors (emacs), a markup language (LaTeX), and display programs (WIP, XV, SAOtng). We have also successfully modified the required plot files to work with our system which display the results of grain processing.

Wolfire, Mark↗

Database Reports Over the Internet

Most of the summer was spent developing software that would permit existing test report forms to be printed over the web on a printer that is supported by Adobe Acrobat Reader. The data is stored in a DBMS (Data Base Management System). The client asks for the information from the database using an HTML (Hyper Text Markup Language) form in a web browser. JavaScript is used with the forms to assist the user and verify the integrity of the entered data. Queries to a database are made in SQL (Sequential Query Language), a widely supported standard for making queries to databases. Java servlets, programs written in the Java programming language running under the control of network server software, interrogate the database and complete a PDF form template kept in a file. The completed report is sent to the browser requesting the report. Some errors are sent to the browser in an HTML web page, others are reported to the server. Access to the databases was restricted since the data are being transported to new DBMS software that will run on new hardware. However, the SQL queries were made to Microsoft Access, a DBMS that is available on most PCs (Personal Computers). Access does support the SQL commands that were used, and a database was created with Access that contained typical data for the report forms.

Dean Lance Smith↗

Controllable Mirror Devices

A deformable Mirror Device (DMD) is a type of spatial light modulator in which mirrors fabricated monolithically on a silicon chip are deformed, or tilted, under electronic control to change the direction of light that falls upon the mirror. NASA and Texas Instruments (TI) have worked to develop this technology, which has subsequently been commercialized by TI. Initial application is the DMD 2000 Travel Information Printer for high speed, high volume printing of airline tickets and boarding passes. Other possible applications range from real-time object tracking to advanced industrial machine vision systems.

Source record↗

Balance System

TherEx Inc.'s AT-1 Computerized Ataxiameter precisely evaluates posture and balance disturbances that commonly accompany neurological and musculoskeletal disorders. Complete system includes two-strain gauged footplates, signal conditioning circuitry, a computer monitor, printer and a stand-alone tiltable balance platform. AT-1 serves as assessment tool, treatment monitor, and rehabilitation training device. It allows clinician to document quantitatively the outcome of treatment and analyze data over time to develop outcome standards for several classifications of patients. It can evaluate specifically the effects of surgery, drug treatment, physical therapy or prosthetic devices.

Source record↗

System Security Authorization Agreement (SSAA) for the WIRE Archive and Research Facility

The Wide-Field Infrared Explorer (WIRE) Archive and Research Facility (WARF) is operated and maintained by the Department of Physics, USAF Academy. The lab is located in Fairchild Hall, 2354 Fairchild Dr., Suite 2A103, USAF Academy, CO 80840. The WARF will be used for research and education in support of the NASA Wide Field Infrared Explorer (WIRE) satellite, and for related high-precision photometry missions and activities. The WARF will also contain the WIRE preliminary and final archives prior to their delivery to the National Space Science Data Center (NSSDC). The WARF consists of a suite of equipment purchased under several NASA grants in support of WIRE research. The core system consists of a Red Hat Linux workstation with twin 933 MHz PIII processors, 1 GB of RAM, 133 GB of hard disk space, and DAT and DLT tape drives. The WARF is also supported by several additional networked Linux workstations. Only one of these (an older 450 Mhz PIII computer running Red Hat Linux) is currently running, but the addition of several more is expected over the next year. In addition, a printer will soon be added. The WARF will serve as the primary research facility for the analysis and archiving of data from the WIRE satellite, together with limited quantities of other high-precision astronomical photometry data from both ground- and space-based facilities. However, the archive to be created here will not be the final archive; rather, the archive will be duplicated at the NSSDC and public access to the data will generally take place through that site.

Source record↗

Programmable Pacemaker

St. Jude Medical's Cardiac Rhythm Management Division, formerly known as Pacesetter Systems, Inc., incorporated Apollo technology into the development of the programmable pacemaker system. This consists of the implantable pacemaker together with a physician's console containing the programmer and a data printer. Physician can communicate with patient's pacemaker by means of wireless telemetry signals transmitted through the communicating head held over the patient's chest. Where earlier pacemakers deliver a fixed type of stimulus once implanted, Programalith enables surgery free "fine tuning" of device to best suit the patient's changing needs.

Source record↗

Space Derived Health Aids (Cardiac Pacemaker)

St. Jude Medical's Cardiac Rhythm Management Division's (formerly known as Pacesetter Systems, Inc.) pacer is a rechargeable cardiac pacemaker that eliminates the recurring need for surgery to implant a new battery. The Programalith is an advanced cardiac pacing system which permits a physician to reprogram a patient's implanted pacemaker without surgery. System consists of a pacemaker, together with a physician's console containing the programmer and a data printer. Signals are transmitted by wireless telemetry. Two-way communications, originating from spacecraft electrical power systems technology, allows physician to interrogate the pacemaker as to the status of the heart, then to fine tune the device to best suit the patient's needs.

Source record↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. electronic sensors. The system comprises any number of transmitting units and a single receiving unit. Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal-conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient temperature sensor that is in addition to the external thermocouples. The control module is a system-on-chip embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display. Each transmitting unit is battery-powered and can operate for at least seven days continuously while reporting temperatures every half hour. The receiving unit is powered by a wall-mounted transformer source. The receiving unit responds to each transmitting unit and reports the readings of each of the four thermocouples and of the ambient-temperature sensor of the transmitting unit. The end-to-end accuracy of the system is plus or minus 0.2 C over the temperature range from 0 to 100 C. The radio-communication range between the receiving and transmitting units is approximately equal to 0.5 mile (approximately equal to 0.8 km).

Solano, Wanda↗

A microarray immunoassay for simultaneous detection of proteins and bacteria

We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

Non-NASA Center↗

Parallel line analysis: multifunctional software for the biomedical sciences

An easy to use, interactive FORTRAN program for analyzing the results of parallel line assays is described. The program is menu driven and consists of five major components: data entry, data editing, manual analysis, manual plotting, and automatic analysis and plotting. Data can be entered from the terminal or from previously created data files. The data editing portion of the program is used to inspect and modify data and to statistically identify outliers. The manual analysis component is used to test the assumptions necessary for parallel line assays using analysis of covariance techniques and to determine potency ratios with confidence limits. The manual plotting component provides a graphic display of the data on the terminal screen or on a standard line printer. The automatic portion runs through multiple analyses without operator input. Data may be saved in a special file to expedite input at a future time.

NASA Discipline Cell Biology↗

Rotordynamics on the PC: Transient Analysis With ARDS

Personal computers can now do many jobs that formerly required a large mainframe computer. An example is NASA Lewis Research Center's program Analysis of RotorDynamic Systems (ARDS), which uses the component mode synthesis method to analyze the dynamic motion of up to five rotating shafts. As originally written in the early 1980's, this program was considered large for the mainframe computers of the time. ARDS, which was written in Fortran 77, has been successfully ported to a 486 personal computer. Plots appear on the computer monitor via calls programmed for the original CALCOMP plotter; plots can also be output on a standard laser printer. The executable code, which uses the full array sizes of the mainframe version, easily fits on a high-density floppy disk. The program runs under DOS with an extended memory manager. In addition to transient analysis of blade loss, step turns, and base acceleration, with simulation of squeeze-film dampers and rubs, ARDS calculates natural frequencies and unbalance response.

Fleming, David P.↗

Information Technology Support in the 8000 Directorate

My summer internship was spent supporting various projects within the Environmental Management Office and Glenn Safety Office. Mentored by Eli Abumeri, I was trained in areas of Information Technology such as: Servers, printers, scanners, CAD systems, Web, Programming, and Database Management, ODIN (networking, computers, and phones). I worked closely with the Chemical Sampling and Analysis Team (CSAT) to redesign a database to more efficiently manage and maintain data collected for the Drinking Water Program. This Program has been established for over fifteen years here at the Glenn Research Center. It involves the continued testing and retesting of all drinking water dispensers. The quality of the drinking water is of great importance and is determined by comparing the concentration of contaminants in the water with specifications set forth by the Environmental Protection Agency (EPA) in the Safe Drinking Water Act (SDWA) and its 1986 and 1991 amendments. The Drinking Water Program consists of periodic testing of all drinking water fountains and sinks. Each is tested at least once every 2 years for contaminants and naturally occurring species. The EPA's protocol is to collect an initial and a 5 minute draw from each dispenser. The 5 minute draw is what is used for the maximum contaminant level. However, the CS&AT has added a 30 second draw since most individuals do not run the water 5 minutes prior to drinking. This data is then entered into a relational Microsoft Access database. The database allows for the quick retrieval of any test@) done on any dispenser. The data can be queried by building number, date or test type, and test results are documented in an analytical report for employees to read. To aid with the tracking of recycled materials within the lab, my help was enlisted to create a database that could make this process less cumbersome and more efficient. The date of pickup, type of material, weight received, and unit cost per recyclable. This information could then calculate the dollar amount generated by the recycling of certain materials. This database will ultimately prove useful in determining the amounts of materials consumed by the lab and will help serve as an indicator potential overuse.

FROM↗

Going End to End to Deliver High-Speed Data

By the end of the 1990s, the optical fiber "backbone" of the telecommunication and data-communication networks had evolved from megabits-per-second transmission rates to gigabits-per-second transmission rates. Despite this boom in bandwidth, however, users at the end nodes were still not being reached on a consistent basis. (An end node is any device that does not behave like a router or a managed hub or switch. Examples of end node objects are computers, printers, serial interface processor phones, and unmanaged hubs and switches.) The primary reason that prevents bandwidth from reaching the end nodes is the complex local network topology that exists between the optical backbone and the end nodes. This complex network topology consists of several layers of routing and switch equipment which introduce potential congestion points and network latency. By breaking down the complex network topology, a true optical connection can be achieved. Access Optical Networks, Inc., is making this connection a reality with guidance from NASA s nondestructive evaluation experts.

Source record↗

Programmatic Approach to Device-Independent Color

Describes an effort to produce device-independent color on three types of devices: color monitors, high precesion color film recorder, and color printer using a dye sublimation process.

device-independent color color management system↗

High Power Laser Diode Array Qualification and Guidelines for Space Flight Environments

Semiconductor laser diodes emit coherent light by simulated emission generated inside the cavity formed by the cleaved end facets of a slab of semiconductor that is typically less than a millimeter in any dimension for single emitters. The diode is pumped by current injection in the p-n junction through the metallic contacts. Laser diodes emitting in the range of 0.8 micron to 1.06 micron have a wide variety of applications from pumping erbium doped fiber amplifiers, dual-clad fiber lasers, solid-state lasers used in telecom, aerospace, military, medical purposes and all the way to CD players, laser printers and other consumer and industrial products. Laser diode bars have many single emitters side by side and spaced approximately .5 mm on a single slab of semiconductor material approximately .5 mm x 10 mm. The individual emitters are connected in parallel maintaining the voltage at -2V but increasing the current to ~50-100A/bar. Stacking these laser diode bars in multiple layers, 2 to 20+ high, yields high power laser diode arrays capable of emitting several hundreds of Watts. Electrically the bars are wired in series increasing the voltage by 2V/bar but maintaining the total current at ~50-100A. These arrays are one of the enabling technologies for efficient, high power solid-state lasers. Traditionally these arrays are operated in QCW (Quasi CW) mode with pulse widths ~10-200 (mu)s and with repetition rates of ~10-200Hz. In QCW mode the wavelength and the output power of the laser reaches steady-state but the temperature does not. The advantage is a substantially higher output power than in CW mode, where the output power would be limited by the internal heating and hence the thermal and heat sinking properties of the device. The down side is a much higher thermal induced mechanical stress caused by the constant heating and cooling cycle inherent to the QCW mode.

Eegholm, Niels↗

Computer Assets Recovery Project

This document reports on the project that was performed during the internship of the author. The project involved locating and recovering machines in various locations that Boeing has no need for, and therefore requires that they be transferred to another user or transferred to a non-profit organization. Other projects that the author performed was an inventory of toner and printers, loading new computers and connecting them to the network.

CortesPena, Aida Yoguely↗

NASA Tech Briefs, November 1995

The contents include: 1) Mission Accomplished; 2) Resource Report: Marshall Space Flight Center; 3) NASA 1995 Software of the Year Award; 4) Microbolometers Based on Epitaxial YBa2Cu3O(sub 7-x) Thin Films; 5) Garnet Random-Access Memory; 6) Fabrication of SNS Weak Links on SOS Substrates; 7) High-Voltage MOSFET Switching Circuit; 8) Asymmetric Switching for a PWM H-Bridge Power Circuit; 9) Better Ohmic Contacts for InP Semiconductor Devices; 10) Low-Bandgap Thermovoltaic Materials and Devices; 11) Digital Frequency-Differencing Circuit; 12) Imaging Magnetometer; 13) Computer-Assisted Monitoring of a Complex System; 14) Buffered Telemetry Demodulator; 15) Compact Multifunction Inspection Head; 16) Optical Detection of Fractures in Ceramic Diaphragms; 17) Eddy-Current Detection of Cracks in Reinforced Carbon/Carbon; 18) Apparent Thermal Conductivity of Multilayer Insulation; 19) Optimizing Misch-Metal Compositions in Metal Hydride Anodes; 20) Device for Sampling Surface Contamination; 21) Probabilistic Failure Assessment for Fatigue; 22) Probabilistic Fatigue and Flaw-Propagation Analysis; 23) Windows Program for Driving the TDU-850 Printer; 24) Subband/Transform MATLAB Functions for Processing Images; 25) Computing Equilibrium Chemical Compositions; 26) Program Processes Thermocouple Readings; 27) ICAN-Second-Generation Integrated Composite Analyzer; 28) Integrated Composite Analyzer with Damping Capabilities; 29) Computing Efficiency of Transfer of Microwave Power; 30) Program Calculates Power Demands of Electronic Designs; 31) Cost-Estimation Program; 32) Program Estimates Areas Required by Electronic Designs; 33) Program to Balance Mapped Turbopump Assemblies; 34) BiblioTech; 35) Controlling Mirror Tilt With a Bimorph Actuator; 36) Burst-Disk Device Simulates Effect of Pyrotechnic Device; 37) Bearing-Mounting Concept Accommodates Thermal Expansion; 38) Parallel-Plate Acoustic Absorbers for Hot Environments; 39) Adjustable-Length Strut Withstands Large Cyclic Loads; 40) Tool Indicates Contact Angles in Bearing Raceways; 41) Gravity Slides With Magnetic Braking; 42) High-Torque, Lightweight, Pneumatically Driven Wrench for Small Spaces; 43) Device for Testing Compatibility of an O-Ring; 44) Magnetic Heat Pump Containing Flow Diverters; 45) Variable-Tilt Helicopter Rotor Mast; 46) "Beach-Ball" Robotic Rovers; 47) Apparatus Would Measure Temperatures of Ball Bearings; 48) Flexible Borescope for Inspecting Ducts; 49) Texturing Copper To Reduce Secondary Emission of Electrons; 50) Automated Laser Cutting in Three Dimensions; 51) Algorithm Helps Monitor Engine Operation; 52) Flexible Revision of Data-Processing Communications; 53) Software for Managing the Use of Land; 54) Thermal Strap Increases Cryocooling Efficiency; 55) Reversible Nut With Engagement Indication; 56) Control Algorithms for Kinematically Redundant Manipulators; 57) Computed Hydrogen-Flow Splits in a Rocket Engine; 58) Pressure and Thermal Modeling of Rocket Launches; 59) Field of View of a Spacecraft Antenna: Analysis and Software; 60) Digital Controller for Laser-Beam-Steering Subsystem; 61) More About Beam-Steering Subsystem for Laser Communication; 62) Digital Controller for Laser-Beam-Steering Subsystem: Part 2; 63) Interface Circuit Board for Space-Shuttle Communications; 64) Automated Planning of Spacecraft Telecommunications; 65) Artifacts of Spectral Analysis of Instrument Readings; 66) Neural-Network Controller for Vibration Suppression; 67) Adaptive Finite-Element Computation in Fracture Mechanics; 68) Attitude Control for the Cassini Spacecraft; 69) Analytical Model for Fluid Dynamics in a Microgravity Environment; 70) Study of Rocket-Engine Joints Bonded by NVCU/NARloy-Z; 71) Improved Silicon Nitride for Advanced Heat Engines; 72) Parameters for Welding Aluminum/Lithium Alloys; 73) Lightweight Composite Intertank Structure; 74) Foil Patches Seal Small Vacuum Leaks; 75) Data Base on Cables and Connectors; 76) Effect of Clock Mode on Radiation Hardnessf an ADC; and 77) Fault-Tolerant Control for a Robotic Inspection System.

Source record↗

Video-Camera-Based Position-Measuring System

A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.

Lane, John↗