Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Electrochemical and galvanic corrosion effects in thin-film photovoltaic modules

The electrochemical and galvanic corrosion properties of thin-film photovoltaic (TF-PV) modules and module subcomponents are determined and interpreted in the light of established corrosion science. Results of a detailed study of thin-film aluminum metallization corrosion are presented. Bar-graph corrosion, observed in fielded modules, has been induced experimentally and found to be electrochemical in nature. Corrosion rates and passivation techniques for TF-PV modules are discussed.

Mon, G.↗

Industry Facing PV Degradation Prediction Tool and Database to Enable a 50-Year Life Module

The Photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 years. Furthermore, research efforts aim for up to 50 years of service life while keeping performance degradation at a minimum for decades of outdoor weathering - putting additional pressure on improving the accuracy of long-term durability and reliability assessments. Here there is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database to perform geospatial degradation analysis in the US and worldwide. Our repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry.

degradation↗

PVDeg: Development of a Streamlined Tool for PV Degradation Modeling

The photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 to 50 years. research efforts aim to achieve this while keeping performance degradation at a minimum for decades. This puts considerable pressure on improving the accuracy of long-term durability and reliability assessments. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. The tool will simplify many of the routine computational operations that are common to many degradation studies. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. This repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors.

degradation↗

Effects of steady state adiabatic convection on the configuration of the near-earth plasma sheet. II

Convection in the plasma sheet is studied using two new two-dimensional, force-balanced magnetospheres that satisfy pV exp 5/3 = constant in the inner and middle plasma sheet. It is confirmed that there exists a substantial set of steady state adiabatic solutions. Like a previously obtained steady state solution, each of these models exhibit a broad minimum in equatorial magnetic field strength B(ze) tailward of the inner edge region between 10 and 20 R(E), but they possess higher values of flux tube content pV exp 5/3 and thus have more stretched tidal configurations and smaller minimum values of B(ze) than those in the original model. A steady state magnetic field model in which B(ze)/B(lobe) at 36 R(E) geocentric distance is close to the observed value has been constructed. The results indicate that the B(ze) minimum tends to form within the Alfven layers. The broader the Alfven layers, the less pronounced the minimum.

Hau, Lin-Ni↗

Photovoltaic device innovation for a solar future

Photovoltaics (PV), also known as solar cells, are now found everywhere - in utility plants; on roofs of homes and commercial buildings; on platforms at sea; in agricultural fields; on vehicles, buildings, drones, and backpacks; and, in their longest running application, providing power in space. Continuous device innovation has led to increased efficiency and improved reliability for multiple PV technologies. Confronted with an urgent need to deploy PV at multiterawatt (TW) scale over the next two decades to mitigate greenhouse gas emissions, PV device innovation takes on new urgency and impact. This perspective reviews recent progress in device design and performance for PV technologies that are currently in commercial production at greater than 1 GW/year or enabling significant space-based power generation - Si, CdTe, CIGS, and multijunction III-V - and looks ahead to the next 5 years. In conclusion, we also identify device-related topics requiring cross-cutting research and innovation.

14 SOLAR ENERGY↗

Maximum Power Reference Tracking Algorithm for Power Curtailment of Photovoltaic Systems

This paper presents an algorithm for power curtailment of photovoltaic (PV) systems under fast solar irradiance intermittency. Based on the Perturb and Observe (P&O) technique, the method contains an adaptive gain that is compensated in real-time to account for moments of lower power availability. In addition, an accumulator is added to the calculation of the step size to reduce the overshoot caused by large irradiance swings. A testbed of a three-phase single-stage, 500 kVA PV system is developed on the OPAL-RT eMEGAsim real-time simulator. Field irradiance data and a regulation signal from PJM (RTO) are used to compare the performance of the proposed method with other techniques found in the literature. Results indicate an operation with smaller overshoot, less dc-link voltage oscillations, and improved power reference tracking capability.

Paduani, Victor↗

On the Issue of Excess Lower Stratospheric Subtropical Transport in GEOS-DAS

In recent years, data assimilation has become an indispensable tool for our understanding of the global features of meteorological variables. However, assessments of transport characteristics using trajectory related methods as well as chemical transport models (CTMs) show that results derived from assimilated (or analyzed) winds exhibit significantly larger mixing and entrainment rates compared to results derived from GCM winds, which are closer to results derived from observations (e.g., Douglass et al., 2002; Schoeberl et al., 2002). This discrepancy presents a serious challenge to our ability to understand and model global trace gas transport and distribution. We use the GEOS-DAS to explore this issue by examining how the process of data assimilation alters the dynamics of the underlying GCM and how this leads to the excess of lower stratospheric mixing and transport in the subtropics. In particular, we show that significant model biases in tropical winds necessitate large analysis increments. These increments directly force large subtropical regions of instability with negative PV gradient on the one hand, and generate excessive noise in the tropical wind fields on the other. The result is an excess of transport in the lower stratospheric subtropics.

Tan, Wei-Wu↗

Data Collection and Analysis [Slides]

The report summarizes the ongoing data collection as well as selection and analysis of field events based on measurement data from project partners.

14 SOLAR ENERGY↗

Data Collection and Analysis [Slides]

The report summarizes the ongoing data collection as well as selection and analysis of field events based on measurement data from project partners.

14 SOLAR ENERGY↗

Measuring the Stress Factors for Photovoltaic (PV) Backsheet Degradation

Back sheet failure has resulted in power loss and large-scale recall of photovoltaic modules, resulting in billions of dollars in lost revenue. The light exposure on the backside of a photovoltaic module comes primarily from reflected light which alters the distribution of natural sunlight. Because of this, modelling the backside exposure and duplicating the exposure is much more difficult than modeling the frontside exposure. This project aims to study how various back sheets and junction box materials degrade under different conditions and to develop Python code to help model and predict degradation. The stress factors for back-sheet degradation must be quantified to extrapolate accelerated stress tests to the field. Test samples were placed in the A3, A4, and A5 conditions, as defined in IEC 62788-7-2, to assess the temperature and humidity dependence of ultraviolet (UV) induced degradation. We are utilizing a custom chamber with exposure from 0.5 UV-suns to 5 UV-suns to understand the dependence of degradation on light intensity. A group of samples put in the A3 condition had glass filters with 50% UV cut-offs of 320 nm, 335 nm, and 360 nm to assess the wavelength dependence of UV degradation. All this data is necessary to assess the impact of non-standard UV light exposure. The material evaluation tests include gloss measurements, attenuated total internal reflectance Fourier transform infrared spectroscopy (ATR-FTIR), UV-visible reflectance/transmittance utilizing a Cary Ci7000 spectrophotometer, and a nano-indenter for surface hardness and modulus measurements. Alongside the experimental work, there is a computational effort using raytracing and Python open-source tools in PVDeg , PVLib, and Bifacial_Radiance. This code will create specific exposure scenarios and enable the evaluation of chamber degradation relative to field degradation. Equation 1 is a strawman equation used to model degradation on the backside of a PV module. We will create simplified code, based on the results of ray-tracing calculations, which uses a view factor approach to provide fast calculations for the most common exposure scenarios.

14 SOLAR ENERGY↗

Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena

Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

First principles modeling of polymer encapsulant degradation in Si photovoltaic modules

An outstanding issue in the longevity of photovoltaic (PV) modules is the accelerated degradation caused by the presence of moisture. Moisture leads to interfacial instability, de-adhesion, encapsulant decomposition, and contact corrosion. However, experimental characterization of moisture in PV modules is not trivial and its impacts can take years or decades to establish in the field, presenting a major obstacle to designing high-reliability modules. First principles calculations provide an alternative way to study the ingress of water and its detrimental effect on the structure and decomposition of the polymer encapsulant and interfaces between the encapsulant and the semiconductor, the metal contacts, or the dielectric layer. Here, we use density functional theory (DFT) computations to model single chain, crystalline and cross-linked structures, infrared (IR) signatures, and degradation mechanisms of ethylene vinyl acetate (EVA), the most common polymer encapsulant used in Si PV modules. IR-active modes computed for low energy EVA structures and possible decomposition products match well with reported experiments. The EVA decomposition energy barriers computed using the Nudged Elastic Band (NEB) method show a preference for acetic acid formation as compared to acetaldehyde, are lowered in the presence of a water solvent or hydroxyl ion catalyst, and match well with reported experimental activation energies. This systematic study leads to a clear picture of the hydrolysis-driven decomposition of EVA in terms of energetically favorable mechanisms, possible intermediate structures, and IR signatures of reactants and products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

Resilience Metrics Framework for Solar Photovoltaics

This presentation was given at the Photovoltaic Specialist Conference (PVSC) 54 in New Orleans, Louisiana. Photovoltaic (PV) systems are routinely exposed to extreme weather, including wind and hail storms. Historically, most systems have proven to be resilient to such events, but some storms have damaged PV systems, leading to physical and financial loss. Storm hardening measures and specific system attributes can reduce this risk. This work introduces a set of resilience metrics and a framework for quantifying, comparing, and predicting PV system resilience. The framework is divided into two parts: 1) predictive, attribute metrics based on site and component characteristics, and 2) impact metrics that assess post-storm performance. Metrics are weighted and aggregated, producing hazard-specific resilience scores. We derive damage functions from storm-impacted PV systems, establishing a baseline against which post-storm performance can be compared. This damage was widely variable across hail and wind intensities, and field hail damage was less than predicted by laboratory tests, suggesting that system features - in addition to storm conditions - influence damage likelihood. Finally, the metrics framework is demonstrated using three case studies of storm damaged PV systems. Although additional data are needed to create attribute specific damage functions and establish metric weights, this study presents a methodology for evaluating PV resilience and contributes new damage functions to the literature.

14 SOLAR ENERGY↗

International Space Station Spacecraft Charging Environments: Modeling, Measurement and Implications for Future Human Space Flight Programs

Spacecraft charging analysis and migration is an interdisciplinary subject combining aspects of electrostatics, plasma physics, ionizing radiation, and materials science, as well as electronic system electromagnetic interference and compatibility (EMI/EMC) effects. Spacecraft charging hazards are caused by the accumulation of electrical charge on spacecraft and spacecraft components produced by interactions with space plasmas, energetic charged particles, and solar UV photons as well as spacecraft electrical power and propulsion systems operations. Spacecraft charging hazard effects include both hard and soft avionics and electrical power system anomalies and have led to the partial or complete loss of numerous spacecraft. The International Space Station (ISS) orbital altitude and inclination (~400 km and 51.6o) determined the dominant natural environment factors affecting ISS spacecraft charging; high speed flight through the geomagnetic field and electrical power system interaction with the cold, high-density ionospheric plasma. In addition ISS is exposed to energetic auroral electrons at high latitude. In this paper we present the results of ISS spacecraft charging modeling and measurements and compare the measurements with numerical modeling of ISS charging processes. ISS is a large metallic structure and flight through the geomagnetic field at orbital speed dominates ISS charging. Collection of ionospheric electrons by the large 160V PV arrays is the next largest contributor. Charging by auroral electrons is detectable but makes a relatively minor contribution. Finally we report the observation of short duration (~ 1 sec) rapid charging peaks associated with shunt/un-shunt operations of the 160V PV arrays, a phenomena not predicted before flight. ISS spacecraft charging environments are radically different from those encountered at higher altitudes in Earth?s magnetosphere and in cis-Lunar space. We present a brief review of those charging environments and an assessment of the applicability of ISS spacecraft charging management and experience to future human spaceflight programs beyond LEO.

Koontz, Steven L.↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Potential vorticity structure of Titan's polar vortices from Cassini CIRS observations

The Cassini mission has provided the best opportunity to date to extensively study the seasonal variation in Titan’s atmosphere, with observations spanning almost half a Titan year (𝐿𝑠 = 293 − 93°). An important feature in the Titan middle-atmosphere is the formation of a polar vortex. Observations have shown that an initially well-developed northern vortex enriched with trace gas species gradually breaks down after spring equinox as a new vortex emerges in southern winter. Here we use Cassini CIRS observations to derive the temperature and composition of the middle-atmosphere. We use the gradient wind equation to first estimate the mean zonal winds, and then the Potential Vorticity (PV) throughout Titan’s atmosphere over the timespan of the Cassini mission. PV is a useful diagnostic quantity for studying the dynamics of polar vortices because it is materially conserved for adiabatic and frictionless flows, and can be inverted to find all other dynamical fields. Our results show the formation of a strong zonal jet in the winter hemisphere, with wind velocities reaching 220 m/s, which is consistent with previous studies. An annular PV structure is also observed over the winter poles, whereby a ring of PV encircles a local minima over the pole. Such distributions are often found to be unstable without a restoring force, yet they are seen here in numerous observations in both the northern and southern hemispheres. A comparison with the annular Martian vortices shows that latent heat release from condensation or subsidence-induced adiabatic heating may explain the origin and stability of the annulus. Finally, we investigate the evolution of the size of the vortices and the role of strong PV gradients as a dynamical mixing barrier for trace gas species across the vortex edge. We find that longer lived gases are less confined to the vortex than those with shorter photochemical lifetimes.

Conor Andrew Nixon↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗