Aerosols at 20 kilometers altitude
Stratospheric aerosols were collected at the 20 km altitude zone by direct impaction on 0.2mm palladium wires in view of the previously observed minimum in particle size frequency distribution between 0.1 and 0.2 microns. Since no minimum in size distribution around 0.2 microns was found, it is concluded that previous equipment was inefficient in collection in this range. Concentration results suggest that low particle concentrations result from small particles agglomerating to form larger ones. Since no indentations were found on the wires used in this experiment, and since there were no differences in the number of particles found on oil-coated surfaces vs uncoated surfaces, the particles in the stratosphere must be liquid, liquid coated, or a slurry.