Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulate matter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Air quality and health impacts of the 2020 wildfires in California

Abstract Background Wildfires in 2020 ravaged California to set the annual record of area burned to date. Clusters of wildfires in Northern California surrounded the Bay Area covering the skies with smoke and raising the air pollutant concentrations to hazardous levels. This study uses the Fire Inventory from the National Center for Atmospheric Research database and the Community Multiscale Air Quality model to estimate the effects of wildfire emissions on air quality during the period from August 16 to October 28 of 2020. In addition, low-cost sensor data for fine particulate matter (PM 2.5 ) from the PurpleAir network is used to enhance modeled PM 2.5 concentrations. The resulting impacts on ozone and PM 2.5 are used to quantify the health impacts caused by wildfires using the Benefits Mapping and Analysis Program – Community Edition. Results Wildfire activity significantly increased direct PM 2.5 emissions and emissions of PM 2.5 and ozone precursors. Direct PM 2.5 emissions surged up to 38 times compared to an average day. Modeling results indicated that wildfires alone led to a rise in ozone daily maximum 8-h average by up to 10 ppb and exceeded PM 2.5 air quality standards in numerous locations by up to 10 times. While modeled PM 2.5 concentrations were lower than measurements, correcting these with PurpleAir data improved the accuracy. The correction using PurpleAir data increased estimates of wildfire-induced mortality due to PM 2.5 exposure by up to 16%. Conclusions The increased hospital admissions and premature mortality attributed to wildfires were found to be comparable to the health impacts avoided by strategies aimed at meeting ozone and PM2.5 air quality standards. This suggests that widespread wildfire emissions can negate years of efforts dedicated to controlling air pollution. The integration of low-cost sensor data proved invaluable in refining the estimates of health impacts from PM2.5 resulting from wildfires.

54 ENVIRONMENTAL SCIENCES↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Impact of acute temperature and air pollution exposures on adult lung function: A panel study of asthmatics

Background Individuals with respiratory conditions, such as asthma, are particularly susceptible to adverse health effects associated with higher levels of ambient air pollution and temperature. This study evaluates whether hourly levels of fine particulate matter (PM 2.5 ) and dry bulb globe temperature (DBGT) are associated with the lung function of adult participants with asthma. Methods and findings Global positioning system (GPS) location, respiratory function (measured as forced expiratory volume at 1 second (FEV 1 )), and self-reports of asthma medication usage and symptoms were collected as part of the Exposure, Location, and Lung Function (ELF) study. Hourly ambient PM 2.5 and DBGT exposures were estimated by integrating air quality and temperature public records with time-activity patterns using GPS coordinates for each participant (n = 35). The relationships between acute PM 2.5 , DBGT, rescue bronchodilator use, and lung function collected in one week periods and over two seasons (summer/winter) were analyzed by multivariate regression, using different exposure time frames. In separate models, increasing levels in PM 2.5 , but not DBGT, were associated with rescue bronchodilator use. Conversely DBGT, but not PM 2.5 , had a significant association with FEV 1 . When DBGT and PM 2.5 exposures were placed in the same model, the strongest association between cumulative PM 2.5 exposures and the use of rescue bronchodilator was identified at the 0–24 hours (OR = 1.030; 95% CI = 1.012–1.049; p-value = 0.001) and 0–48 hours (OR = 1.030; 95% CI = 1.013–1.057; p-value = 0.001) prior to lung function measure. Conversely, DBGT exposure at 0 hours (β = 3.257; SE = 0.879; p-value>0.001) and 0–6 hours (β = 2.885; SE = 0.903; p-value = 0.001) hours before a reading were associated with FEV 1 . No significant interactions between DBGT and PM 2.5 were observed for rescue bronchodilator use or FEV 1 . Conclusions Short-term increases in PM 2.5 were associated with increased rescue bronchodilator use, while DBGT was associated with higher lung function (i.e. FEV 1 ). Further studies are needed to continue to elucidate the mechanisms of acute exposure to PM 2.5 and DBGT on lung function in asthmatics.

60 APPLIED LIFE SCIENCES↗

Association between long-term exposure to ambient air pollution and COVID-19 severity: a prospective cohort study

The tremendous global health burden related to COVID-19 means that identifying determinants of COVID-19 severity is important for prevention and intervention. We aimed to explore long-term exposure to ambient air pollution as a potential contributor to COVID-19 severity, given its known impact on the respiratory system. Methods: We used a cohort of all people with confirmed SARS-CoV-2 infection, aged 20 years and older and not residing in a long-term care facility in Ontario, Canada, during 2020. We evaluated the association between long-term exposure to fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ) and ground-level ozone (O 3 ), and risk of COVID-19-related hospital admission, intensive care unit (ICU) admission and death. We ascertained individuals’ longterm exposures to each air pollutant based on their residence from 2015 to 2019. We used logistic regression and adjusted for confounders and selection bias using various individual and contextual covariates obtained through data linkage. Results: Among the 151105 people with confirmed SARS-CoV-2 infection in Ontario in 2020, we observed 8630 hospital admissions, 1912 ICU admissions and 2137 deaths related to COVID-19. For each interquartile range increase in exposure to PM 2.5 (1.70 µg/m 3 ), we estimated odds ratios of 1.06 (95% confidence interval [CI] 1.01–1.12), 1.09 (95% CI 0.98–1.21) and 1.00 (95% CI 0.90–1.11) for hospital admission, ICU admission and death, respectively. Estimates were smaller for NO 2 . We also estimated odds ratios of 1.15 (95% CI 1.06–1.23), 1.30 (95% CI 1.12–1.50) and 1.18 (95% CI 1.02–1.36) per interquartile range increase of 5.14 ppb in O 3 for hospital admission, ICU admission and death, respectively.

60 APPLIED LIFE SCIENCES↗

Lead isotopic compositions of airborne particulates collected from snow and from dry deposition in the East River Watershed, Colorado and at the Southern Sierra Critical Zone Observatory, California

The data set consists of lead (Pb) isotopic ratios (206Pb/207Pb and 208Pb/207Pb, as well as 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb) for particulate samples collected from snow and dry deposition. This was part of a study (O’Day et al. 2020) that was looking at the speciation of phosphorous in splits of these samples to evaluate the flux and bio-availability of phosphorous to the mountain sites in the study. The Pb isotopic data allow sourcing of long-range transported Pb, specifically the fraction of Pb sourced in Asia, and so a comparison of the relative distances of PM sources between the high and low elevation sites. Samples were collected at the East River Watershed, CO (dry deposition collected over Sept.-Oct. 2016, show sampling winter 2017) and at the Southern Sierra Critical Zone Observatory (dry deposition collected over Sept-Nov 2016, July-Sept 2017, June-July 2017). The data includes Pb concentration data, as well as calculated fraction of the Pb sourced in Asia. This data set was published in part in O’Day et al. (2020) Phosphorus Speciation in Atmospherically Deposited Particulate Matter and Implications for Terrestrial Ecosystem Productivity. ES&T, https://dx.doi.org/10.1021/acs.est.9b06150

54 ENVIRONMENTAL SCIENCES↗

Influence of root- vs needle-derived litter on soil C and N stabilization in a California coniferous forest from 2001 to 2011

How plant inputs from above- versus below-ground affect long term carbon (C) and nitrogen (N) retention and stabilization in soils is not well known. We present results of a decade-long field study that traced the decomposition of 13C- and 15N-labeled Pinus ponderosa needle and fine root litter placed in O or A soil horizons of a sandy Alfisol under a coniferous forest. We measured the retention of litter-derived C and N in particulate (>2 mm) and bulk soil (<2 mm) fractions, as well as in density-separated free light and three mineral-associated fractions. After 10 years, the influence of slower initial mineralization of root litter compared to needle litter was still evident: almost twice as much root litter (44% of C) was retained than needle litter (22–28% of C). After 10 years, the O horizon retained more litter in coarse particulate matter implying the crucial comminution step was slower than in the A horizon, while the A horizon retained more litter in the finer bulk soil, where it was recovered in organo-mineral associations. Retention in these A horizon mineral-associated fractions was similar for roots and needles. Nearly 5% of the applied litter C (and almost 15% of the applied N) was in organo-mineral associations, which had centennial residence times and potential for long-term stabilization. Vertical movement of litter-derived C was minimal after a decade, but N was significantly more mobile. Overall, the legacy of initial litter quality influences total SOM retention; however, the potential for and mechanisms of long-term SOM stabilization are influenced not by litter type but by soil horizon.This dataset comprises (1) litter recovery for each of 5 timepoints in >2mm, <2mm, and density fractions, (2) density fractionation results for the 10-year timepoint, and (3) vertical movement of applied litter.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Air Quality Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Air Quality Data at Chicago State University Prairie Site

The Air Quality Transmitter (AQT) (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (Nitric Oxide (NO), Nitrogen Dioxide (NO2), Ozone (O3)), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments.This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Air Quality Data at Argonne National Laboratory Prairie Site

The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-002 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-002), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Capture from ArcelorMittal Hot Briquetted Iron Plant Using Air Liquide Cryocap™ FG Technology – FEED Study

The process of steel production is energy and carbon intensive with global average energy consumption of 5.5 MWh/tonne of steel and CO2 emission intensity of 1.83 tonne CO2/tonne of steel. The steel making process has inherent CO2 emissions from mineral conversion and is considered major contributors to the global carbon emissions. The steel industry is responsible for 8% of global carbon emissions. The main objective of this research project is to execute and complete a front-end engineering and design (FEED) study for a commercial-scale, carbon capture project that separates 95% of the total CO2 emissions at the ArcelorMittal’s Hot Briquetted Iron (HBI) plant in Portland, TX (Figure 1). The HBI is an ore-based metallic that is used as high-grade feedstock for high-quality steel via an Electric Arc Furnace (EAF) route. The HBI plant produces 2.0 million metric tonnes of high-quality HBI and emits approximately 1 million tonnes CO2/yr. The capture system is a Pressure Swing Adsorption (PSA) system assisted Cryocap™ FG technology (Figure 2). The captured CO2 will be pipeline grade and will be geologically stored in a facility within 10 miles of the CO2 source. The Host Site location in Corpus Christi, TX, is near hydrocarbon processing facilities and near Environmental Justice (EJ) and Qualified Opportunity Zone (QOZ) communities. Due to the location of the Host Site, the retrofit project offers the ability to demonstrate how a workforce focused on the fossil energy sector can be redirected to the clean- energy sector. The Air Liquide Cryocap™ capture technology is a proven technology and has been extensively examined for large industrial applications. It has been shown to be applicable to a variety of industrial applications including the steel industry. Cryocap™ FG (specific setup for Flue Gas application) consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The scope of this study incorporates completing FEED study of the CO2 capture system which includes point-source CO2 capture and balance-of-plant; Business Case Analysis (BCA) outlining the current and projected volumes of the steel plant’s point sources of CO2 and the potential utilization of tax credits, including its projected revenue and duration; Life Cycle Analysis (LCA); Environmental Justice Analysis; Economic Revitalization and Job Creation Outcomes Analysis; and Workforce Readiness Plan. The plant design work was divided into two components: Inside Battery Limits (ISBL) and Outside Battery Limits (OSBL). The ISBL focuses on the capture system, while the OSBL focuses on the utility feeds and ducting from the plant to the capture system. Various design and engineering deliverables will be developed to define commodity quantities, equipment specifications, and labour effort required to execute the project. These FEED study deliverables will be prepared with the intent to develop an overall project capital cost estimate consistent with an AACE Class 3 estimate. The modular approach for the Cryocap™ FG that is being designed for this study integrates compression, PSA, and cryogenic “bricks” to achieve the desired CO2 capture rates. This carbon capture system integrates easily with the existing plant, thus reducing project costs and risks. It is also capable of managing impurities such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, hydrocarbons, and particulate matter. The capture system has a smaller footprint than amine-based systems. The two-step process uses PSA to preconcentrate the CO2 in the feedstream and then uses the cryogenic portion to purify and compress the resulting high purity CO2 product. This combination of purification and compression (i.e., process intensification) significantly reduces the CAPEX associated with use of a separate compressor commonly utilized for amine solvent-based systems. Successful completion of the FEED study will provide DOE with a detailed understanding of the costs for scaling up this proven capture technology for commercial applications at industrial facilities.

42 ENGINEERING↗

Energy Performance Validation of a Gaseous Air Cleaning Technology for Commercial Buildings

The U.S. Department of Energy (DOE) Building Technologies Office Commercial Building Integration group conducts evaluations of new energy efficiency technologies as part of the High Impact Technology Catalyst program. The subject of this field validation project is an air cleaning technology that removes gaseous contaminants from indoor air to reduce outdoor air ventilation requirements. Reducing the volume of outdoor air required reduces heating, ventilating, and air conditioning (HVAC) loads and can provide significant energy savings for some buildings in certain climates. The technology, called the HLR (HVAC Load Reduction), was developed by enVerid. The technology uses a solid regenerable sorbent material that was developed by DOE's National Energy Technology Laboratory and licensed to the vendor for this application. The sorbent material was originally developed to adsorb carbon dioxide (CO2); the vendor continued to develop the sorbent and the overall system so that it can also remove volatile organic compounds (including aldehydes), carbon monoxide, ozone, and particulate matter 2.5 micrometers in diameter or smaller (PM2.5) from the air. This material has low regeneration temperature requirements, and its sorption properties are unaffected by humidity levels, both of which are beneficial for building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Final Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2010. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past decade, the study has now been completed, and all forty-nine HEPA filters have been replaced, due to either technical issues listed in this report, or the previously recommended filter “age limit” of 10 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spray Combustion and Soot Formation

Mitigating particulate matter (PM) emissions while simultaneously controlling nitrogen oxide and hydrocarbon emissions is critical for both gasoline and diesel engines. The problem is especially critical during cold-start cycles where aftertreatment devices are less effective. Understanding how liquid sprays and films form PM and designing to change the outcome requires advanced combustion concepts developed through joint experimental and computational efforts. However, existing spray and soot computational models are oversimplified and non-physical, and are therefore unable to reliably capture quantitative or even qualitative trends over a wide range of engine operating conditions. This task involves the development and application of advanced optical diagnostics and high-pressure gas and particle sampling/analysis in unique high-temperature, high-pressure vessels to investigate spray dynamics and soot formation with the objective of providing fundamental understanding about soot processes under relevant engine conditions to aid the development of improved soot models for commercial CFD codes

02 PETROLEUM↗

Heavy-Duty Low-Temperature and Diesel Combustion & Heavy-Duty Combustion Modeling (FY 2018 Annual Progress Report)

Regulatory drivers and market demands for lower pollutant emissions, lower carbon dioxide emissions, and lower fuel consumption motivate the development of clean and fuel-efficient engine operating strategies. Most current production engines use a combination of both in-cylinder and exhaust emission control strategies to achieve these goals. The emissions and efficiency performance of in-cylinder strategies depend strongly on flow and mixing processes associated with fuel injection. Both heavy- and light-duty engine/vehicle manufacturers use multiple-injection strategies to reduce noise, emissions, and fuel consumption. For both conventional and low-temperature diesel combustion, the state of knowledge and modeling tools for multiple injections are far less advanced than for single-injection strategies. Engine efficiency is limited to some degree by tradeoffs that must be accepted to meet particulate matter (including soot) emissions limits. Recent work on this project has filled some knowledge gaps on soot oxidation with multiple injections, and the current work for Fiscal Year (FY) 2018 addresses knowledge gaps on soot formation for multiple injections. While total in-cylinder soot is readily measured, discerning formation from oxidation is difficult. The FY 2018 experiments are designed to create in-cylinder conditions at the threshold of soot formation, where processes that affect soot formation can be more readily discerned. Soot formation pathways under such conditions are fraught with uncertainties, and soot models significantly overpredict polyaromatic hydrocarbon (PAH) and soot, so experimental data at these conditions will provide much needed data for improvements to PAH and soot models.

02 PETROLEUM↗