Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Implementation of the Lifetime Method in Unsteady Pressure Sensitive Paint Measurements

At NASA Ames Research Center, unsteady pressure-sensitive paint (uPSP) measurements are obtained using the ‘intensity method’ which measures paint luminescence in response to a continuous, constant excitation. These measurements are obtained using high-speed cameras and are processed into fluctuating components of pressure. However, the nature of the intensity method also requires a separate steady state (time mean) pressure measurement to be obtained. This steady state measurement has typically been obtained using a separate set of PSP equipment that uses the ‘lifetime method’, which uses pulsed excitation to measure paint decay lifetime. If the lifetime method were implemented in the high-speed uPSP system, both the fluctuating and mean components of pressure could be obtained with a single system. This would greatly streamline setup, operations, and processing. In this paper, we describe work performed at the Fluid Mechanics Laboratory at NASA Ames to implement the lifetime method in our uPSP system. The uPSP acquisition system uses Phantom v2512 high-speed cameras, and it was initially uncertain if results of adequate quality could be obtained - their high framerate comes at the cost of several undesirable characteristics, which are explored in this paper. It was also uncertain if illumination using LED lamps, rather than a stronger source such as lasers, would be adequate. The data acquisition and data processing are discussed and the results analyzed. It was found that satisfactory lifetime method results can indeed be obtained using these high-speed cameras and LED lamps. This will allow the uPSP system to be greatly simplified and will have a large operational impact on how uPSP data is acquired in future wind tunnel tests.

Pressure Sensitive Paint↗

Implementation of the Lifetime Method in uPSP Measurements

At NASA Ames Research Center, unsteady pressure-sensitive paint (uPSP) measurements are obtained using the ‘intensity method’ which measures paint luminescence in response to a continuous, constant excitation. These measurements are obtained using high-speed cameras and are processed into fluctuating components of pressure. However, the nature of the intensity method also requires a separate steady state (time mean) pressure measurement to be obtained. This steady state measurement has typically been obtained using a separate set of PSP equipment that uses the ‘lifetime method’, which uses pulsed excitation to measure paint decay lifetime. If the lifetime method were implemented in the high-speed uPSP system, both the fluctuating and mean components of pressure could be obtained with a single system. This would greatly streamline setup, operations, and processing. In this paper, we describe work performed at the Fluid Mechanics Laboratory at NASA Ames to implement the lifetime method in our uPSP system. The uPSP acquisition system uses Phantom v2512 high-speed cameras, and it was initially uncertain if results of adequate quality could be obtained - their high framerate comes at the cost of several undesirable characteristics, which are explored in this paper. It was also uncertain if illumination using LED lamps, rather than a stronger source such as lasers, would be adequate. The data acquisition and data processing are discussed and the results analyzed. It was found that satisfactory lifetime method results can indeed be obtained using these high-speed cameras and LED lamps. This will allow the uPSP system to be greatly simplified and will have a large operational impact on how uPSP data is acquired in future wind tunnel tests.

Pressure Sensitive Paint↗

Thermosyphon Flooding Limits in Reduced Gravity Environments

Fission Power Systems have long been recognized as potential multi-kilowatt power solutions for lunar, Martian, and extended planetary surface missions. Current heat rejection technology associated with fission surface power systems has focused on titanium water thermosyphons embedded in carbon composite radiator panels. The thermosyphons, or wickless heat pipes, are used as a redundant and efficient way to spread the waste heat from the power conversion unit(s) over the radiator surface area where it can be rejected to space. It is well known that thermosyphon performance is reliant on gravitational forces to keep the evaporator wetted with the working fluid. One of the performance limits that can be encountered, if not understood, is the phenomenon of condenser flooding, otherwise known as evaporator dry out. This occurs when the gravity forces acting on the condensed fluid cannot overcome the shear forces created by the vapor escaping the evaporator throat. When this occurs, the heat transfer process is stalled and may not re-stabilize to effective levels without corrective control actions. The flooding limit in earth's gravity environment is well understood as experimentation is readily accessible, but when the environment and gravity change relative to other planetary bodies, experimentation becomes difficult. An innovative experiment was designed and flown on a parabolic flight campaign to achieve the Reduced Gravity Environments (RGE) needed to obtain empirical data for analysis. The test data is compared to current correlation models for validation and accuracy.

Gibson, Marc A.↗

Orbital spacecraft consumables resupply

The capability to replenish spacecraft, satellites, and laboratories on-orbit with consumable fluids provides significant increases in their cost and operational effectiveness. Tanker systems to perform on-orbit fluid resupply must be flexible enough to operate from the Space Transportation System (STS), Space Station, or the Orbital Maneuvering Vehicle (OMV), and to accommodate launch from both the Shuttle and Expendable Launch Vehicles (ELV's). Resupply systems for storable monopropellant hydrazine and bipropellants, and water have been developed. These studies have concluded that designing tankers capable of launch on both the Shuttle and ELV's was feasible and desirable. Design modifications and interfaces for an ELV launch of the tanker systems were identified. Additionally, it was determined that modularization of the tanker subsystems was necessary to provide the most versatile tanker and most efficient approach for use at the Space Station. The need to develop an automatic umbilical mating mechanism, capable of performing both docking and coupler mating functions was identified. Preliminary requirements for such a mechanism were defined. The study resulted in a modular tanker capable of resupplying monopropellants, bipropellants, and water with a single design.

Dominick, Sam M.↗

Phase Change Processes for Thermal Management Systems and Science Investigations

This white paper focuses on the scientific rationale and motivation for deploying phase change processes-based spacecraft thermal management systems for space missions [1,2]. Phase change processes need to be implemented in the design of various life support systems, sub-critical cryogenic and thermal control systems, taking advantage of the latent heat of phase change so as to significantly increase the heat transfer rate per unit fluid mass. Experimental data are critical to understanding gravitational effects on complex phase change processes using novel materials and working fluids. Experimental data can be acquired by either designing new testing platforms or performing experiments with simulant fluids on existing microgravity platforms. With the acquired data, theoretical flow physics models and numerical simulations can then be validated for use under long-duration microgravity conditions. The acquired data and validated models will enable the deployment of game-changing thermal management systems with remarkably improved efficiency and stability in heat acquisition, transport, and rejection for long-duration space missions.

Fluid mechanics↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗

A Computational Fluid Dynamics Algorithm on a Massively Parallel Computer

The discipline of computational fluid dynamics is demanding ever-increasing computational power to deal with complex fluid flow problems. We investigate the performance of a finite-difference computational fluid dynamics algorithm on a massively parallel computer, the Connection Machine. Of special interest is an implicit time-stepping algorithm; to obtain maximum performance from the Connection Machine, it is necessary to use a nonstandard algorithm to solve the linear systems that arise in the implicit algorithm. We find that the Connection Machine ran achieve very high computation rates on both explicit and implicit algorithms. The performance of the Connection Machine puts it in the same class as today's most powerful conventional supercomputers.

Jespersen, Dennis C.↗

Risk Analysis Associated with Loss of Toxic Gases During Orion Landing and Recovery Operations

Mission, landing and recovery operations for the Orion crew module involve reentry into the Earth's atmosphere and the deployment of three Nomex parachutes to slow the descent before landing along the west coast of the United States. Orion may have residual fuel (hydrazine, N2H4) or coolant (ammonia, NH3) on board which are both highly toxic to crew in the event of exposure. These risks were evaluated using a first principles analysis approach through fluid dynamics modeling. Plume calculations were first performed with the ANSYS Fluent computational fluid dynamics code. Data were then extracted at locations relevant to crew safety such as the snorkel fan inlet and the egress hatch. Mixing calculations were performed to quantify exposure concentrations within the crew bay before and during egress and departure. Finally, results included herein were used to inform the Orion post-landing Concept of Operations (ConOps) so that strategies could be formulated to maintain crew safety in the event of the loss of fuel or coolant.

Orion↗

Validation of Cryogenic Propellant Tank Self-Pressurization by Leveraging Reduced Order Modeling within Computational Fluid Dynamics Simulation

Validation of cryogenic propellant tank self-pressurization was performed using a hybrid Computational Fluid Dynamics (CFD) and reduced order modeling methodology. Data from a liquid hydrogen ground test conducted at the K-site facility at the National Aeronautics and Space Administration (NASA) Glenn Research Center was used for the validation effort. Liquid phase dynamics were explicitly resolved with a CFD tool. Vapor phase dynamics were modeled as a point mass that communicated heat from the tank wall to the liquid phase via a boundary condition used at the gas-liquid interface. The method proved to be more accurate, robust, and efficient than explicit resolution of the dynamics using a standard Volume of Fluid (VOF) methodology. The subject pressurization process was found to be heavily dependent upon both the relatively high liquid temperature gradient near the gas-liquid interface and the natural convection flow path. Modeling the gas-liquid interface as an immovable surface eliminated temperature gradient destroying gas-liquid interface velocities observed in VOF simulations, and correspondingly enabled more rapid simulation since interface advection was not allowed. The single phase computational domain also facilitated the ability to demonstrate spatial resolution convergence of natural convection cells within the liquid which significantly impacted the tank pressurization rate. This work was used to demonstrate the critical physics for tank self-pressurization and numerical methodologies that may be used to best resolve those physics. The findings informed development and operation of production level CFD tools used in the Fluid Dynamics Branch at NASA Marshall Space Flight Center.

J. M. Brodnick↗

Intermediate Temperature Ceramic Heat Pipe Modeling and Optimization

Spacecraft nuclear electric propulsion, as well as other emerging technologies, can benefit from heat pipes with optimal performance in the intermediate temperature, 450–700 K, regime. In this work, a 1D model was developed to investigate the performance of halide working fluids coupled with 3D printed-ceramic shells to operate at 500–600 K and interface with a nuclear electric propulsion system. An initial conceptual design and performance limits of a 3D printed-AlN heat pipe radiator with AlBr 3 as the working fluid is presented. An areal density of 5.2 kg/m 2 and mass per unit heat performance of 1.00kg/kW is estimated.

thermal management↗

GFFC experiment progress

Vibration, out-gas, and acoustic tests performed on the Geophysical Fluid Flow Cell (GFFC) instrument are reported. The slope of the 59 experiments to be performed by GFFC is outlined. Spacelab 3 crew training on the operation of the GFFC instrument is mentioned.

Leslie, F.↗

Performance of a hybrid chemical/mechanical heat pump

The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

Silvestri, John J.↗

Lubricating properties of molybdenum disulfide. Part 3: Performance of molybdenum disulfide-containing oils in fluid lubrication

The lubricating properties of a straight mineral oil with and without MoS2 powder were studied. Bearing testers of thrust-collar type and of journal bearing type were used for thin- and fluid-film conditions, respectively. The effectiveness of the MoS2 powder in the oil differed depending on the conditions of the rubbing surfaces. For fluid film conditions, considerable effects of the MoS2 were observed, in contrast to the thin-film cases. The addition of MoS2 powder was effective only when the lubricant film was formed between surfaces thickly enough to allow the inflow of MoS2 particles.

Soda, Norimune↗

Parametric Performance of a Spiral-Artery, Liquid-Trap-Diode Heat Pipe

A series of parametric investigations are described which determine the effect of various fluid charges on the performance of a 0.635-cm-diam spiral-artery, liquid-trap diode in both the forward and reverse modes. Specific parameters such as forward- and reverse-mode conductances, shutdown times and energies, and recovery to forward-model operation, are evaluated for ethane as a working fluid in the temperature range 170 K to 220 K. Results indicate that the heat pipe will not reliably start up in the forward mode. However, startup can be initiated when preceded by a diode reversal. Also included are data which show the susceptibility of the diode to fluid charge and tilt. The optimum fluid charge was found to be 2.67 g and transport capability at this charge was in excess of 1200 W-cm at 200 K. The diode in the reverse mode exhibited a rapid shutdown (within 9 min) with a shutdown energy of 1150 J (0.32 Wh).

Williams, R. J.↗

Space station experiment definition: Long term cryogenic fluid storage

A preliminary design of an experiment to demonstrate and evaluate long-term cryogenic fluid storage and transfer technologies has been performed. This Long-Term Cryogenic Fluid Storage (LTCFS) experiment is a Technology Development Mission (TDM) experiment proposed by the NASA Lewis Research Center to be deployed on the Initial Operational Capability (IOC) space station. Technologies required by future orbital cryogenic systems such as Orbital Transfer Vehicles (OTV's) were defined, and critical technologies requiring demonstration were chosen to be included in the experiment. A three-phase test program was defined to test the following types of technologies: (1) Passive Thermal Technologies; (2) Fluid Transfer Technologies; and (3) Active Refrigeration Technologies. The development status of advanced technologies required for the LTCFS experiment is summarized, including current, past and future programs.

Riemer, David H.↗