Search NASA⌕ Search

SEARCH · Search NASA

Results for “Permeability Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Lunar surface magnetometer experiment

The Apollo 15 lunar-surface magnetometer (LSM) is one of a network of magnetometers that have been deployed on the moon to study intrinsic remanent magnetic fields and global magnetic response of the moon to large-scale solar and terrestrial magnetic fields. From these field measurements, properties of the lunar interior such as magnetic permeability, electrical conductivity, and temperature can be calculated. In addition, correlation with solar-wind-spectrometer data allows study of the the solar-wind plasma interaction with the moon and, in turn, investigation of the resulting absorption of gases and accretion of an ionosphere. These physical parameters and processes determined from magnetometer measurements must be accounted for by comprehensive theories of origin and evolution of the moon and solar system.

Dyal, P.↗

New insights into the drainage of inundated ice-wedge polygons using fundamental hydrologic principles

Abstract. The pathways and timing of drainage from the inundated centers of ice-wedge polygons in a warming climate have important implications for carbon flushing, advective heat transport, and transitions from methane to carbon dioxide dominated emissions. Here, we expand on previous research using a recently developed analytical model of drainage from a low-centered polygon. Specifically, we perform (1) a calibration to field data identifying necessary model refinements and (2) a rigorous model sensitivity analysis that expands on previously published indications of polygon drainage characteristics. This research provides intuition on inundated polygon drainage by presenting the first in-depth analysis of drainage within a polygon based on hydrogeological first principles. We verify a recently developed analytical solution of polygon drainage through a calibration to a season of field measurements. Due to the parsimony of the model, providing the potential that it could fail, we identify the minimum necessary refinements that allow the model to match water levels measured in a low-centered polygon. We find that (1) the measured precipitation must be increased by a factor of around 2.2, and (2) the vertical soil hydraulic conductivity must decrease with increasing thaw depth. Model refinement (1) accounts for runoff from rims into the ice-wedge polygon pond during precipitation events and possible rain gauge undercatch, while refinement (2) accounts for the decreasing permeability of deeper soil layers. The calibration to field measurements supports the validity of the model, indicating that it is able to represent ice-wedge polygon drainage dynamics. We then use the analytical solution in non-dimensional form to provide a baseline for the effects of polygon aspect ratios (radius to thaw depth) and coefficient of hydraulic conductivity anisotropy (horizontal to vertical hydraulic conductivity) on drainage pathways and temporal depletion of ponded water from inundated ice-wedge polygon centers. By varying the polygon aspect ratio, we evaluate the relative effect of polygon size (width), inter-annual increases in active-layer thickness, and seasonal increases in thaw depth on drainage. The results of our sensitivity analysis rigorously confirm a previous analysis indicating that most drainage through the active layer occurs along an annular region of the polygon center near the rims. This has important implications for transport of nutrients (such as dissolved organic carbon) and advection of heat towards ice-wedge tops. We also provide a comprehensive investigation of the effect of polygon aspect ratio and anisotropy on drainage timing and patterns, expanding on previously published research. Our results indicate that polygons with large aspect ratios and high anisotropy will have the most distributed drainage, while polygons with large aspect ratios and low anisotropy will have their drainage most focused near their periphery and will drain most slowly. Polygons with small aspect ratios and high anisotropy will drain most quickly. These results, based on parametric investigation of idealized scenarios, provide a baseline for further research considering the geometric and hydraulic complexities of ice-wedge polygons.

Harp, Dylan R. (ORCID:0000000197778000)↗

Corrosion protection of steel pipelines with metal-polymer composite barrier liners

Pipelines are efficient in transporting natural gas over large distances. Wet carbon dioxide present in pipelines can create an environment that is corrosive to steel. Polymer liners made from either polyethylene or polyamide (nylon) are presently used to mitigate internal corrosion in natural gas pipelines. Gas diffuses through all polymers over time, and polymer-only liners lower the steel corrosion rate by reducing the reactive gas flux to the internal surface of a pipeline. Composite liners, which incorporate one or more metallic layers that are impermeable to corrosive gases, offer better protection than polymer-only liners. In this study, we measured the methane, water vapor, and carbon dioxide permeability of a multi-layer barrier film and found it to be more effective in resisting gas permeation than polyethylene and nylon-11 films.

03 NATURAL GAS↗

Bayesian Poroelastic Aquifer Characterization From InSAR Surface Deformation Data. Part I: Maximum A Posteriori Estimate

Characterizing the properties of groundwater aquifers is essential for predicting aquifer response and managing groundwater resources. In this work, we develop a high-dimensional scalable Bayesian inversion framework governed by a three-dimensional quasi-static linear poroelastic model to characterize lateral permeability variations in groundwater aquifers. In this work, we determine the maximum a posteriori (MAP) point of the posterior permeability distribution from centimeter-level surface deformation measurements obtained from Interferometric Synthetic Aperture Radar (InSAR). The scalability of our method to high parameter dimension is achieved through the use of adjoint-based derivatives, inexact Newton methods to determine the MAP point, and a Mat´ern class sparse prior precision operator. Together, these guarantee that the MAP point is found at a cost, measured in number of forward/adjoint poroelasticity solves, that is independent of the parameter dimension. We apply our methodology to a test case for a municipal well in Mesquite, Nevada, in which InSAR and GPS surface deformation data are available. We solve problems with up to 320,824 state variable degrees of freedom (DOFs) and 16,896 parameter DOFs. A consistent treatment of noise level is employed so that the aquifer characterization result does not depend on the pixel spacing of surface deformation data. Our results show that the use of InSAR data significantly improves characterization of lateral aquifer heterogeneity, and the InSAR-based aquifer characterization recovers complex lateral displacement trends observed by independent daily GPS measurements.

54 ENVIRONMENTAL SCIENCES↗

An Additively Manufactured Fe-3Si Stator for a High-Performance Electrical Motor

Additive manufacturing (AM) has the potential to produce novel high-performance electrical machines, enabling the direct printing of complex shapes and the simultaneous processing of multiple feedstocks in a single build. We examined the properties and functional performance of Fe-3 wt.% Si materials that were printed via selective laser melting, machined down to thin laminates, and stacked to form a stator core of a prototype brushless permanent-magnet electrical motor. Big Area Additive Manufacturing of Nd2Fe14B (NdFeB)–polyphenylene sulfide (PPS) bonded magnets was performed, with them then being magnetized and used for the rotor. The magnetic, mechanical, and electrical properties of the as-printed and various heat-treated thin laminates and the back electromotive force (EMF) of the electrical motors at different rotational speeds were measured. The thin laminates exhibit a maximum relative permeability of 7494 at an applied field of 0.8 Oe and a core loss of about 20 W/lb at 60 Hz with the maximum induction of 15 kg. In addition to the demonstration of AM printing, motor assembly, and complete characterization of printed Fe-3 wt.% Si, this report highlights the areas of improvement needed in printing technologies to achieve AM built electrical motors and the need for isotropic microstructure refinements to make the laminates appropriate for high-mechanical-strength and low-loss rotational electrical devices.

36 MATERIALS SCIENCE↗

VARTM Process Modeling of Aerospace Composite Structures

A three-dimensional model was developed to simulate the VARTM composite manufacturing process. The model considers the two important mechanisms that occur during the process: resin flow, and compaction and relaxation of the preform. The model was used to simulate infiltration of a carbon preform with an epoxy resin by the VARTM process. The model predicted flow patterns and preform thickness changes agreed qualitatively with the measured values. However, the predicted total infiltration times were much longer than measured most likely due to the inaccurate preform permeability values used in the simulation.

Song, Xiao-Lan↗

Validation of Play Fairway Analysis of the geothermal potential of Camas Prairie, south-central Idaho, by an exploration well

Abstract Play Fairway Analysis (PFA) methodology was adapted for geothermal exploration at Camas Prairie, Idaho. Geophysical data, structural and geologic mapping, volcanic rock ages and vent locations, and the distribution of thermal springs and wells all indicated a relatively high geothermal potential along the southern margin of the Prairie. An exploration well (USU Camas-1) was drilled to a depth of 618.3 m to validate the PFA. A permeable zone was encountered at ~ 357.5 m with a maximum measured temperature of ~ 80 °C, which was suppressed following the injection of cold water. A moderate transmissivity of ~ 0.25–1 cm 2 /s estimated from an injection test as well a seasonal artesian flow at ~ 0.7 L/s corroborate the presence of a permeable zone. The existence of a lacustrine clay seal was confirmed near the bottom of the basin-fill sediment occupying the upper 314 m of the well. Geothermometers suggest the USU Camas-1 well water equilibrated at a reservoir temperature of ~ 120 °C. Based on the locations of both thermal and cold wells, geothermal fluids appear to be flowing upward along one or both of two fault systems. The presence of young basalts and elevated helium isotope ratios suggest that the heat source of Camas Prairie is magmatic. However, the faults may be acting as a conduit for geothermal fluids to rise from great depth without a shallow magmatic source being present. Camas Prairie is a promising area for geothermal development, but the relatively low reservoir temperatures indicate this resource may not be suitable for electric generation. Perhaps the best use would be for heating.

Lachmar, Thomas E. (ORCID:0000000249640119)↗

Characterization of Aquifer Poroelastic Response to Impulse and Oscillatory Well Pressure Using Distributed Acoustic Sensing

Abstract The storage of fluids in the subsurface is critical for a broad spectrum of applications including managed aquifer recharge, storage of liquefied carbon dioxide and hydrogen, geothermal heat extraction and exploitation of hydrocarbon. It is surprising then, that there has been relatively little measurement of the vertical distribution of poroelastic storage in geologic formations as compared with permeability. We present experiments in which fluid was injected into an important regional aquifer and the depth‐dependent strain response measured using fiber optic distributed acoustic sensing. The formation expansion and contraction in response to fluid injection were several 100 nanostrain. Strain, and the implied storage distribution, was highly localized in specific strata and demonstrated complex, hydromechanical behavior. This new window into fluid‐geomechanical coupling undermines some typically use models and observations currently in practice, but provides potential for complete representation and prediction of fluid storage in the subsurface.

58 GEOSCIENCES↗

Complexity of Fault Rupture and Fluid Leakage in Shale: Insights From a Controlled Fault Activation Experiment

Abstract We observed rupture growth caused by controlled fluid injections at 340‐m depth within a fault zone in the low‐permeability Opalinus Clay in the Mont Terri Underground Research Laboratory (Switzerland). The rupture mechanisms were evaluated using measurements of the three‐component borehole wall displacements and fluid pressure in two sections of the fault zone and located horizontally 3 m apart from each other. One section was set across a secondary segment of the fault and used for stepwise fluid injection intended to trigger rupture growth. The other section was set across the principal shear zone of the fault for monitoring. After stepwise pressure increase up to 5.95 MPa at injection, rupture initiated as slip activation, followed by an overall opening of the fault planes connected to the injection. After 19 s of continued injection, displacements arrived at the monitoring point on the principal shear zone. These displacements are about 2.4 times larger than in the secondary fault segment. Overall, the displacements corresponded to a normal fault activation. About 9 s after the displacement front arrived, a strong pressure increase of 4.17 MPa was measured at the monitoring point, indicating a hydraulic connection had formed along the initially very low permeability fault planes between the injection and the monitoring points. Our analyses highlight that the fault activation is consistent with the state of stress but that injection pressure must be close to the normal stress acting on the fault for permeability to be generated and for fluid leakage to occur.

Guglielmi, Yves↗

Stress Analysis and Permeability Testing of Cryogenic Composite Feed Line

For the next generation Single-Stage-To-Orbit (SSTO) Reusable Launch Vehicle (RLV), the use of advanced composite materials is highly desirable and critical to the success of the mission. NASA Marshall Space Flight Center (MSFC) has been working with the aerospace industry for many years to develop and demonstrate the cryogenic composite propellant tanks and feed lines technologies. A 50.8-mm diameter composite feed line for the Clipper Graham (DCY.A) was developed and tested. The purpose of the program is to demonstrate the LH2 permeability, composite to composite and metal joints, as well as composite flange interface of the composite feed line. Stress analysis and permeability testing have been performed on this article. Recently, a larger composite feed line design is being investigated and developed at MSFC for potential use in future RLV. The diameter of the feed line is 203 mm and the overall length is approximately 2.2 meters. This one piece unlined feed line consists of three straight tubular sections joined by two 90 degree elbows. The material chosen is IM7/977-3 prepreg fabric. The lay-up pattern is [0/90, plus or minus 45]s and is built up to 18 plies to the flanges at both ends. A preliminary stress analysis has been conducted to identify potential critical stresses and to develop the finite element analysis (FEA) capability of composite feed lines. As expected, the critical stresses occurred at the rims of some flange holes and the onset of the tapered tubular sections. Further analysis is required to determine the loads, flange deflection, vibration, and combined maximum loads. Two permeability-testing apparatuses were also designed for both flat panel specimens and curved feed line sections after impact damage. A larger permeant gas exposed area is required to accurately determine the effect of impact damage on the permeability of the feed line materials. The flat panel tester was fabricated and assembled. Three test coupons were made of graphite/epoxy plain weave prepreg and unidirectional prepreg. The flow rate was calculated by measuring the change of manometer fluid height per unit time. The permeability of the coupons is then calculated according to Darcy's Law. The pressure increase due to the head rise in the manometer was not considered for the initial estimation. The result of the unidirectional composite coupon agreed with that obtained from the DC-XA feed line testing of a similar material. Further improvement on the design may be required to improve the accuracy and efficiency of permeability testing.

Chu, Tsuchin Philip↗

A proposed magnetic digital temperature transducer, volume 1

A study has been made of the feasibility of using the discontinuous permeability versus temperature characteristics of some magnetic materials for a digital temperature transducer and a thermally controlled ON-OFF switch. Simple logic converts the number of output pulse to a digital word recognizable by the system. Efforts have been concentrated on materials with Curie temperatures between 0 and 100 C. One compound has the composition Mn(5-x)Fe(x)Ge3 where the amount of iron determines the transition temperature. The other compound is Ni-Zn ferrite and has the compositon Ni(1-x)Zn(x)Fe(1.95)O4 where the nickel: zinc ratio determines the transition temperature. A detailed report of materials prepared is presented. Toroidal inductors of the material have been constructed and the change in inductance with temperature measured. In view of these initial measurements, it is felt that a transducer utilizing the permeability versus temperature characteristics of these materials has promise as a reliable and sensitive solid state digital temperature transducer.

Collier, T. E.↗

Quantifying the Influence of Defects on Selectivity of Electrodes Encapsulated by Nanoscopic Silicon Oxide Overlayers

Encapsulation of electrocatalysts and photocatalysts with semipermeable nanoscopic oxide overlayers that exhibit selective transport properties is an attractive approach to achieve high redox selectivity. However, defects within the overlayers-such as pinholes, cracks, or particle inclusions-may facilitate local high rates of parasitic reactions by creating pathways for facile transport of undesired reactants to exposed active sites. Scanning electrochemical microscopy (SECM) is an attractive method to determine the influence of defects on macroscopic performance metrics thanks to its ability to measure the relative rates of competing electrochemical reactions with high spatial resolution over the electrode. Here, we report the use of SECM to determine the influence of overlayer defects on the selectivity of silicon oxide (SiOx) encapsulated platinum thin-film electrocatalysts operated under conditions where two competing reactions-the hydrogen evolution and Fe(III) reduction reactions-can occur. After an SECM methodology is described to determine spatially resolved selectivity, representative selectivity maps are correlated with the location of defects that are characterized by optical, electron, and atomic force microscopies. This analysis reveals that certain types of defects in the oxide overlayer are responsible for ∼60-90% of the partial current density toward the undesired Fe(III) reduction reaction. By correcting for defect contributions to Fe(III) reduction rates, true Fe(III) permeability values for the SiOxoverlayers were determined to be over an order of magnitude lower than permeabilities determined from analyses that ignore the presence of defects. Lastly, different types of defects were studied revealing that defect morphology can have varying influence on both redox selectivity and calculated permeability. This work highlights the need for spatially resolved measurements to evaluate the performance of oxide-encapsulated catalysts and understand their performance limits.

25 ENERGY STORAGE↗

Noncontacting transducer measures shaft torque

Transducer for measuring the output torque of a rotating shaft uses a magnetically permeable sleeve fitted over a section of the shaft which deflects axially in direct proportion to the output torque. A corresponding change in reluctance occurs in pickup coils mounted in close proximity to the sleeve. This change is measured by attached conventional circuitry.

Source record↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

Salt and ion transport in a series of crosslinked AMPS/PEGDA hydrogel membranes

Salt permeability and ionic conductivity are critical properties for membranes in water purification and energy applications. Both properties depend on individual ion sorption and diffusion coefficients, which are significantly influenced by polymer chemical and physical parameters such as fixed charge concentration and membrane water content. However, systematic studies connecting polymer structure to ion transport properties are still lacking. In this study, a series of uncharged and charged membranes were synthesized using poly(ethylene glycol) diacrylate (PEGDA) as a cross-linker and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) as a charged monomer. Membrane fixed charge concentration and water uptake were systematically varied by adjusting AMPS content in the pre-polymerization mixture. Salt sorption and permeability coefficients and ionic conductivity of these membranes were measured as a function of NaCl solution concentration (0.01–1 M). Combining the solution-diffusion model and Nernst-Planck equation, individual ion diffusion coefficients were calculated. Experimental Na + diffusion coefficients for all materials were well described by the Mackie and Meares tortuosity model, highlighting the strong influence of water content on ion diffusivity in both uncharged and charged polymers. Model predictions for Cl – diffusion coefficients agree reasonably well with experimental values, with some deviations occurring in more highly charged membranes. Finally, this discrepancy might result from interactions not captured by the Mackie and Meares model (e.g., fixed charge-ion interactions).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ammonia Permeation Through Inorganic Membranes

Moisture probes are used in the tritium facility to measure the moisture content of the gas stream. When tritium reacts with nitrogen to form ammonia, the ammonia gas damages the sensitive moisture probe. The gas stream tested during this experiment for moisture probe protection is composed of nitrogen and argon gas in conjunction with ammonia and water vapor. The gas stream is filtered through an inorganic membrane due to the high reactivity of tritium and a residual gas analyzer (RGA) is used to measure the ammonia and water vapor in the gas stream, as well as the permeability of nitrogen and argon through the inorganic membranes. The membranes tested were boron nitride and silver. The permeability was compared for each membrane at different pressures and flow rates. Fourier-transformed infrared spectroscopy (FT-IR) was used to compare the membranes before and after ammonia permeation. Ammonia gas is a byproduct formed from tritium gas reacting with nitrogen in the gas stream, similar to the Haber Process which occurs when hydrogen reacts with nitrogen [2]. The corrosive nature of ammonia damages metals and sensitive instruments such as moisture probes. Moisture probes are essential in various gas and liquid processes for measuring the moisture content of a gas. Membrane research has found that graphene oxide membranes successfully uptake ammonia from the gas stream at a humidity of approximately 30% at which point the pores pin closed, preventing gas permeation. Further research is being conducted to find an inorganic membrane that will prevent ammonia permeation thus circumventing damage to the sensitive moisture probe. The permeation measurements for argon and nitrogen gas and water and ammonia vapor were measured at various pressures of 800, 1000, 1200, 1500, 1800, and 2000 torr. The permeability average (PA) was calculated for each filter using a Barrer calculation. The average permeations for each filter were then compared. The gas composition was measured using the RGA Nitrogen was permeated through the membranes after ammonia permeation and a FT-IR spectrum was obtained. Boron Nitride: As the nitrogen pressure increased, the permeability of the membrane decreased from 800-1200 torr and remained relatively unchanged from 1200-2000 torr. The membrane exhibited a slight decrease in argon permeability from 800-1200 torr and a slight increase from 1500-2000 torr. The boron nitride membrane when permeated with ammonia and nitrogen prevented less ammonia permeation compared to the blank filter. The boron nitride filter demonstrated a decrease in permeability after ammonia permeation. Silver Membrane: When permeated with nitrogen alone, the membrane permeability decreased from 800 torr to 1200 torr. The permeability of the membrane showed little difference as pressure increased from 1200 torr. When permeated with argon, the same phenomenon occurred but on a much smaller scale. When compared to the blank and the boron nitride membranes the silver membrane exhibited significantly lower permeability. This may be in part due to the coating on the silver membrane and differences in pore size of the membranes. During permeation with ammonium hydroxide vapor and nitrogen, the partial pressure of the ammonia increased as compared to the blank membrane. The permeability before and after permeation with ammonia and nitrogen were compared. Permeability values suggested that after being permeated with the ammonia that the permeability for lower pressures increased slightly. There was no significant change in the FT-IR spectrums before and after permeation. Future work: Continue testing various inorganic membranes for ammonia permeation. Further research chemical separation of ammonia from the gas stream, which may prove difficult due to the high reactivity of tritium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of wall permeability on turbulent boundary-layer properties

Experimental boundary-layer studies of a series of low pressure drop, permeable surfaces have been conducted to characterize their surface interaction with a turbulent boundary layer. The models were flat and tested at nominally zero pressure gradient in low speed air. The surfaces were thin metal sheets with discrete perforations. Direct drag balance measurements of skin friction indicate that the general effect of surface permeability is to increase drag above that of a smooth plate reference level. Heuristic arguments are presented to show that this type of behavior is to be expected. Other boundary-layer data are also presented including mean velocity profiles and conditionally sampled streamwise velocity fluctuations (hot wire) for selected models.

Wilkinson, S. P.↗