Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physics, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fabrication of carbon film composites for high-strength structures

Physical and mechanical properties of fiber composite materials consisting of carbon films are described. Application of carbon film structural composites for constructing microwave filters or optical instruments is proposed. Applications in aerospace and architectural structures for high strength and low density properties are discussed.

Preiswerk, P. R.↗

An optical radar for airborne use over natural waters

An optical radar for detecting targets in natural waters was built and tested in the Gulf of Mexico. The transmitter consists of a Q switched neodymium glass laser, with output amplified and doubled in KDP to 0.53 micrometer wavelength. The receiver incorporates a noval optical spatial filter to reduce the dynamic range required of the photodetector to a reasonable value. Detection of targets to a depth of 26 meters (84 feet) was achieved with a considerable sensitivity margin. The sensitivity of the radar is highly dependent on the optical attenuation coefficient. In general, measured returns fell between the values predicted on the basis of monopath and multipath attenuation. By means of simple physical arguments, a radar equation for the system was derived. To validate this theoretical model, measurements of optical attenuation and of water surface behavior were also instrumented, and some of these results are given.

Levis, C. A.↗

Detecting Super-Thin Clouds with Polarized Sunlight

We report a novel method for detecting cloud particles in the atmosphere. Solar radiation backscattered from clouds is studied with both satellite data and a radiative transfer model. A distinct feature is found in the angle of linear polarization of solar radiation that is backscattered from clouds. The dominant backscattered electric field from the clear-sky Earth-atmosphere system is nearly parallel to the Earth surface. However, when clouds are present, this electric field can rotate significantly away from the parallel direction. Model results demonstrate that this polarization feature can be used to detect super-thin cirrus clouds having an optical depth of only ~0.06 and super-thin liquid water clouds having an optical depth of only ~0.01. Such clouds are too thin to be sensed using any current passive satellite instruments.

Aerosols and particles↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Quasi-Distributed Fiber Sensor-Based Approach for Pipeline Health Monitoring: Generating and Analyzing Physics-Based Simulation Datasets for Classification

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.

36 MATERIALS SCIENCE↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Power Laser Diode Array Qualification and Guidelines for Space Flight Environments

High-power laser diode arrays (LDAs) are used for a variety of space-based remote sensor laser programs as an energy source for diode-pumped solid-state lasers. LDAs have been flown on NASA missions including MOLA, GLAS and MLA and have continued to be viewed as an important part of the laser-based instrument component suite. There are currently no military or NASA-grade, -specified, or - qualified LDAs available for "off-the-shelf" use by NASA programs. There has also been no prior attempt to define a standard screening and qualification test flow for LDAs for space applications. Initial reliability studies have also produced good results from an optical performance and stability standpoint. Usage experience has shown, howeve that the current designs being offered may be susceptible to catastrophic failures due to their physical construction (packaging) combined with the electro-optical operational modes and the environmental factors of space application. design combined with operational mode was at the root of the failures which have greatly reduced the functionality of the GLAS instrument. The continued need for LDAs for laser-based science instruments and past catastrophic failures of this part type demand examination of LDAs in a manner which enables NASA to select, buy, validate and apply them in a manner which poses as little risk to the success of the mission as possible.

Ott, Melanie N.↗

Remote sensing of smoke, clouds, and radiation using AVIRIS during SCAR experiments

During the past two years, researchers from several institutes joined together to take part in two SCAR experiments. The SCAR-A (Sulfates, Clouds And Radiation - Atlantic) took place in the mid-Atlantic region of the United States in July, 1993. remote sensing data were acquired with the Airborne Visible Infrared Imaging Spectrometer (AVIRIS), the MODIS Airborne Simulator (MAS), and a RC-10 mapping camera from an ER-2 aircraft at 20 km. In situ measurements of aerosol and cloud microphysical properties were made with a variety of instruments equipped on the University of Washington's C-131A research aircraft. Ground based measurements of aerosol optical depths and particle size distributions were made using a network of sunphotometers. The main purpose of SCAR-A experiment was to study the optical, physical and chemical properties of sulfate aerosols and their interaction with clouds and radiation. Sulfate particles are believed to affect the energy balance of the earth by directly reflecting solar radiation back to space and by increasing the cloud albedo. The SCAR-C (Smoke, Clouds And Radiation - California) took place on the west coast areas during September - October of 1994. Sets of aircraft and ground-based instruments, similar to those used during SCAR-A, were used during SCAR-C. Remote sensing of fires and smoke from AVIRIS and MAS imagers on the ER-2 aircraft was combined with a complete in situ characterization of the aerosol and trace gases from the C-131A aircraft of the University of Washington and the Cesna aircraft from the U.S. Forest Service. The comprehensive data base acquired during SCAR-A and SCAR-C will contribute to a better understanding of the role of clouds and aerosols in global change studies. The data will also be used to develop satellite remote sensing algorithms from MODIS on the Earth Observing System.

Gao, Bo-Cai↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Injection of electron beams into two laser wakefields and generation of electron rings

Throughout this work, mutual injection of electron beams into two laser plasma wakefields was observed experimentally when driving laser pulses interfered in plasma at a small crossing angle and were slightly relatively delayed, approximately by one pulse duration. Particle-in-cell simulations revealed that the mutual injection was sensitive to the spatial overlap of the laser pulses, which therefore could be used to control the mutual injection. The dual synchronized, femtosecond electron beams are potentially useful for pump-probe experiments in ultrafast science. In addition, out-of-axis ring-shaped electron beams were detected in both experiments and simulations.

47 OTHER INSTRUMENTATION↗

Development of moored oceanographic spectroradiometer

Biospherical Instruments has successfully completed a NASA sponsored SBIR (Small Business Innovational Research Program) project to develop spectroradiometers capable of being deployed in the ocean for long periods of time. The completion of this project adds a valuable tool for the calibration of future spaceborne ocean color sensors and enables oceanographers to extend remote sensing optical techniques beyond the intermittent coverage of spaceborne sensors. Highlights of the project include two moorings totalling 8 months generating extensive sets of optical, biological, and physical data sets in the ocean off La Jolla, California, and a 70 day operational deployment of the resulting commercial product by the ONR and NASA sponsored BIOWATT program. Based on experience gained in these moorings, Biospherical Instruments has developed a new line of spectroradiometers designed to support the oceanographic remote sensing missions of NASA, the Navy, and various oceanographers.

Booth, Charles R.↗

The Mars oxidant experiment (MOx) for Mars '96

The MOx instrument was developed to characterize the reactive nature of the martian soil. The objectives of MOx were: (1) to measure the rate of degradation of organics in the martian environment; (2) to determine if the reactions seen by the Viking biology experiments were caused by a soil oxidant and measure the reactivity of the soil and atmosphere: (3) to monitor the degradation, when exposed to the martian environment, of materials of potential use in future missions; and, finally, (4) to develop technologies and approaches that can be part of future soil analysis instrumentation. The basic approach taken in the MOx instrument was to place a variety of materials composed as thin films in contact with the soil and monitor the physical and chemical changes that result. The optical reflectance of the thin films was the primary sensing-mode. Thin films of organic materials, metals, and semiconductors were prepared. Laboratory simulations demonstrated the response of thin films to active oxidants.

Flight Experiment↗