Measurements of plasma energy density and conductivity from 3 to 120 kbar.
Plasma energy density, conductivity and temperature measurements at various pressures
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Plasma energy density, conductivity and temperature measurements at various pressures
Density irregularities play a vital role in determining how radio frequency (RF) waves travel through plasmas. In the Earth’s ionosphere, these density irregularities also impact radio communication. In this study, we conduct a detailed numerical analysis of RF wave propagation in small-scale ionospheric density irregularities using the advanced Petra-M code. We focus specifically on high-frequency (HF) waves, ranging from 3 to 30 MHz, which are essential for military, amateur radio operators, and emergency communications. By introducing density structures, such as equatorial plasma bubbles derived from fluid simulations, we demonstrate that HF waves can scatter in multiple directions when they encounter these irregularities. Additionally, we observe significant mode conversion, where incoming electromagnetic waves transform into electrostatic modes within the density gradient layer. This shows that smaller density irregularities can greatly weaken signals or cause complete signal loss for receivers, emphasizing the need for increased awareness and innovative solutions in radio communication transmission.
Due to intrinsically low magnetic fields, at low density the drift speed of the current-carrying electrons in spherical tokamaks can exceed fraction of the Alfvén speed sufficient for the excitation of the Alfvén gap modes. A particular case of the toroidal mode, observed during minor disruptions in Ohmic shots on SUNIST [Liu et al., Phys. Plasmas 23, 120706 (2016)], is considered in the present communication. Due to the negligible effect of the electron pressure gradient, the growth rate scales linearly with the drift speed, with slope inversely proportional to electron thermal velocity. In the absence of continuum damping, the threshold value of the drift speed for TAE excitation is independent of electron temperature.
A 16-cm diameter plasma source operated on argon is described that is capable of producing a plasma environment that closely simulates the low Earth orbit (LEO) conditions experienced by satellites in the altitude range between 300 to 500 km. The plasma source uses a transverse-field magnetic filter, and has been successful in producing low electron temperature plasmas that contain streaming ion populations. Both of these characteristics are important because the plasma in LEO is relatively cold (e.g., Te approx. 0.1 eV) and the ram energy of the ions due to the motion of the satellite relative to the LEO plasma is high (e.g., 7,800 m/s which corresponds to approx. 5 eV for O+ ions). Plasma source operational conditions of flow rate and discharge power are presented that allow the electron temperature to be adjusted over a range from 0.14 to 0.4 eV. The expanding plasma flow field downstream of the source contains both low-energy, charge-exchange ions and streaming ions with energies that are adjustable over a range from 4 eV to 6 eV. At low flow rates and low facility pressures, the streaming ion component of the ion population comprises over 90% of the total plasma density. In the work described herein, a large area retarding potential analyzer was used to measure both electron and ion energy distribution functions in the low density, expanding plasma produced downstream of the plasma source. The benefits of using this type of plasma diagnostic tool in easily perturbed, low-density plasma are identified, and techniques are also discussed that can be used to perform real-time measurements of electron temperature. Finally, recommendations are made that may enable lower electron temperatures to be produced while simultaneously decreasing the plasma source flow rate below 1 to 2 sccm.
We study experimentally the effect of linear plasma density gradients on the self-modulation of a 400 GeV proton bunch. Results show that a positive or negative gradient increases or decreases the number of microbunches and the relative charge per microbunch observed after 10 m of plasma. The measured modulation frequency also increases or decreases. With the largest positive gradient we observe two frequencies in the modulation power spectrum. Results are consistent with changes in wakefields’ phase velocity due to plasma density gradients adding to the slow wakefields’ phase velocity during self-modulation growth predicted by linear theory.
The origin of lion roars, intense electromagnetic whistler-mode waves which occur throughout the magnetosheath, is investigated based on particle and field data obtained on the ISEE satellites. Analysis of the measured magnetic fields, plasma densities and plasma wave intensities during periods of lion roar emission reveals the lion roar bursts to be correlated with decreases in magnetic field intensity, while the plasma density exhibits a strong anticorrelation with the magnetic field variability during the bursts and the total plasma pressure remains essentially constant. Results indicate that the waves can originate by the cyclotron resonant instability with anisotropic magnetosheath electrons whenever the magnetic energy per particle falls to values comparable with the electron thermal energy. Variations in the magnetic energy appear to be associated with the hydromagnetic mirror instability which in turn is excited by a pressure anisotropy in the magnetosheath ion population.
Astrophysical flows may be studied by reproducing similar conditions using a coaxial plasma accelerator operating in the deflagration regime (or plasma deflagration accelerator). This allows for the recreation and investigation of dynamics present in complex highly coupled plasma systems at the laboratory scale. Here we report on measurements of the plasma density, temperature, plasma potential and velocity found using a quadruple Langmuir probe (QLP) on such a deflagration accelerator in the form of the Stanford Coaxial High ENerGy (CHENG) device operating with multiple gases – specifically argon, nitrogen and hydrogen. Experiments show a general decrease in bulk plasma velocity with gas atomic mass from upwards of 120 km s –1 with hydrogen to less than 30 km s –1 with argon. There was an accompanying increase in peak plasma density with increasing atomic mass from ~3 × 10 20 m –3 with hydrogen to ~1.5 × 10 21 m –3 with argon. It was found that the momentum flux and internal energy density also generally increase with atomic mass while the particle flux is constant between shots. Further investigation is needed to understand these correlations and the underlying physics. Lastly, comparisons with scaling laws show that while the CHENG device may be operated in such a way as to simulate the effects of bulk solar wind movement, it may not properly capture the thermal effects.
On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.
For a three-hour period in the magnetotail over which plasma density varied from less than 0.1 to about 1/cu cm, comparisons of ISEE-1 spherical double probe (dawn to dusk) electric field measurements and ISEE-2 plasma flows (converted to electric fields) show the zero lag cross correlation coefficient between 768 second averages of the two data sets to have been 0.93. A statistical relative uncertainty between pairs of points in the two data sets, estimated by only including counting statistics in the plasma measurement and time variations of the observed electric field over the measurement interval, is able to account for at least 75 percent of the deviations between the two data sets. In agreement with simple Langmuir probe theory, it has been found that the spacecraft potential measured over the three-hour interval by the double probe instrument varied as the log of the product of the plasma density and the square root of the electron temperature.
A recent effort to digitize the plasma density by using the low frequency cutoff of trapped continuum radiation in the vicinity of the Jovian plasma sheet has revealed the existence of sharply defined density structures in the plasma sheet. These structures typically have a plasma density which is relatively constant but of order 50 percent greater or less than in the surrounding plasma. At the boundaries of these structures, the transitions from low to high density occur on time scales of about ten seconds, which correspond to spatial dimensions on the order of a few ion Larmor radii. The structures themselves last for intervals from less than a minute to more than five minutes, corresponding to size scales from a fraction of a Jovian radius to more than a Jovian radius, depending of the velocity of the structure relative to the spacecraft. In view of the importance of near corotation plasma flows, these structures are likely to be limited in both the longitudinal and radial dimensions and, therefore, could represent flux tubes with greatly varying plasma content. These observations are presented as among the first to directly address the theoretically proposed interchange instability.
A recent effort to digitize the plasma density by using the low frequency cutoff of trapped continuum radiation in the vicinity of the Jovian plasma sheet has revealed the existence of sharply defined density structures in the plasma sheet. These structures typically have a plasma density which is relatively constant but of order 50 percent greater or less than in the surrounding plasma. At the boundaries of these structures, the transitions from low to high density occur on time scales of about ten seconds, which correspond to spatial dimensions on the order of a few ion Larmor radii. The structures themselves last for intervals from less than a minute to more than five minutes, corresponding to size scales from a fraction of a Jovian radius to more than a Jovian radius, depending on the velocity of the structure relative to the spacecraft. In view of the importance of near corotation plasma flows, these structures are likely to be limited in both the longitudinal and radial dimensions and, therefore, could represent flux tubes with greatly varying plasma content. These observations are presented as among the first to directly address the theoretically proposed interchange instability.
Plasma energy density and conductivity measured at pressures from 3 to 120 kilobars
Understanding the physics of collisionless, magnetized plasmas is key to unlocking a number of important problems in space and astrophysics. Magnetic reconnection is a fundamental mechanism which can explosively release stored magnetic energy, convert it to plasma heat and flows, and accelerate particles. In this project we developed technique and conducted experiments and simulations of magnetic reconnection in laser produces plasmas. Through this project, we also developed experimental techniques to generate magnetized collisionless shocks, and we therefore expanded the scope of the project to develop these experiments. These projects make fundamental progress on understanding the dynamics of magnetized laser-produced plasmas. In additional to plasma astrophysics, these results have broad interest for laboratory high energy density plasmas, since magnetic fields can be used to confine and control plasmas in many contexts and may offer new capabilities toward laboratory ignited plasmas.
The intensities of X-ray transitions in highly charged ions in the Be I, B I, and Ne I isoelectronic sequences have been calculated as functions of electron density. The intensities of the transitions from the 2s(n)2p(m)3p configuration, relative to the intensities from the 2s(n)2p(m)3s and 2s(n)p(m)3d configurations, are strong functions of electron density in high-density plasmas. The density sensitivity occurs at electron densities between 10 to the 16th/cu cm (for Si ions) and 10 to the 22nd/cu cm (for Kr ions). Opacity is unimportant for plasma dimensions that are characteristic of dense laser-produced plasmas. These X-ray line ratios represent a promising new density diagnostic for high-density plasmas.
The generation of solid-density plasmas in a controlled manner using an X-ray free electron laser (XFEL) has opened up the possibility of diagnosing the atomic properties of hot, strongly coupled systems in novel ways. Previous work has concentrated on K-shell emission spectroscopy of low Z (<= 14) elements. Here, we extend these studies to the mid-Z(=32) element Germanium, where the XFEL creates copious L-shell holes, and the plasma conditions are interrogated by recording of the associated L-shell X-ray emission spectra. Given the desirability of generating as uniform a plasma as possible, we present here a study of the effects of the FEL photon energy on the temperatures and electron densities created, and their uniformity in the FEL beam propagation direction. We show that good uniformity can be achieved by tuning the photon energy of the XFEL such that it does not overlap significantly with L-shell to M-shell bound-bound transitions, and lies below the L-edges of the ions formed during the heating process. Reasonable agreement between experiment and simulations is found for the emitted X-ray spectra, demonstrating that for these higher Z elements, the selection of appropriate XFEL parameters is important for achieving uniformity in the plasma conditions.
The generation of plasma density fluctuations by nonlinear Alfven waves is considered. Of particular interest is the modification to the 'static approximation', describing the relationship between wave intensity and plasma density, when the Alfven wave packet is rapidly steepening. The study concentrates on a forced wave equation for the plasma density, which yields the static approximation in a select approximnation. An analytic solution to this equation is obtained for a reasonable model of a steeping wave packet. The principal results are: (1) the static approximation should give a surprisingly robust description of the coupling between Alfven wave intensity and plasma density; (2) departures of the plasma density perturbation from the static approximation result are determined by a parameter that is a simple function of the wave amplitude and plasma beta; (3) for rapidly evolving wave packets, the position of maximum density change is displaced from that of maximum wave intensity, and (4) the magnitude of the density fluctuation will not be much different than the static approximation estimate.
We measured blood density (BD). plasma density (PD) and hematocrit (Ht) during repeated 70 deg head-up tilt (HUT) consisting of a pre-drink period with two supine (P and P3) and two HUT (P2 and P4) phases of 45 min each. At the end of P4 test subjects (N=8) drank 10 ml/kg body weight of isotonic (290 mOsm/kg) sodium chloride (ISO) or hypotonic (<10 mOsm/kg) unsweetened us (HYP), or nothing (control: CON). The following periods continued the supine (P5, P7) / upright (P6) sequence. Mass density of plasma and whole blood using a "mechanical oscillation" technique were measured from ear lobe blood. Tilting altered (p<0.001) BD, PD, and Ht in all consecutive Phases. BD and PD were different (p<0.05) between CON. HYP. and ISO Phases 6 and 7. The computed mass density of fluid (FD). which moved between intra. and extravascular compartments. averaged 1008 g/l and was the same in any conditions. In the non-drink treatment (P3, P5, P7), supine PV steadly decreased when compared to P1. Tilt-induced PV shifts ranged from 9.7 to 16.7% when compared to PV du. ring the respective previous Phases. After drinking, PV increased above CON values at the end of Phase 7 by 12.9% with ISO, and by 6.6% with HYP. Progressive hemoconcentration. occurred during non-drink supine; isotonic saline ingestion increased supine PV a control level but did not stop or reverse the decrease of upright hemoconcentration. Upright density values were not slowed with repeated upright tilting; decreased fluid loss occurred in consecutive upright periods. Upright capillary pressure balance was achieved with diminished plasma volume loss during repeated tilting.
Linear and nonlinear responses of a magnetoplasma resulting from inhomogeneity in the background plasma density are studied. The plasma response to an impulse electric field was measured and the results are compared with the theory of an inhomogeneous cold plasma. Impulse responses were recorded for the different plasma densities, static magnetic fields, and neutral pressures and generally appeared as modulated, damped oscillations. The frequency spectra of the waveforms consisted of two separated resonance peaks. For weak excitation, the results correlate with the linear theory of a cold, inhomogeneous, cylindrical magnetoplasma. The damping mechanism is identified with that of phase mixing due to inhomogeneity in plasma density. With increasing excitation voltage, the nonlinear impulse responses display stronger damping and a small increase in the frequency of oscillation.