Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

New interpretation of ion cyclotron emission from a tokamak

The tempting interpretation of ion cyclotron emission in terms of compressional Alfvén eigenmodes involving energetic ions is inconsistent with recent TCV experimental observations in some important aspects, such as (i) the perturbed poloidal field is exceeding the parallel perturbed magnetic field significantly, and (ii) the modes are near cyclotron harmonic and exhibit Alfvèn scaling of their frequency. We show that these characteristics can be explained by considering finite Larmor radius effects of thermal ions in shear Alfvén waves that allow such waves to exist well above the ion cyclotron frequency in the form of wave-packets bouncing within the plasma volume.

Plasma waves↗

Evidence for central venous pressure resetting during initial exposure to microgravity

We measured central venous pressure (CVP); plasma volume (PV); urine volume rate (UVR); renal excretion of sodium (UNa); and renal clearances of creatinine, sodium, and osmolality before and after acute volume infusion to test the hypothesis that exposure to microgravity causes resetting of the CVP operating point. Six rhesus monkeys underwent two experimental conditions in a crossover counterbalance design: 1) continuous exposure to 10 degrees head-down tilt (HDT) and 2) a control, defined as 16 h/day of 80 degrees head-up tilt and 8 h prone. After 48 h of exposure to either test condition, a 120-min course of continuous infusion of isotonic saline (0.4 ml. kg(-1). min(-1) iv) was administered. Baseline CVP was lower (P = 0.011) in HDT (2.3 +/- 0.3 mmHg) compared with the control (4.5 +/- 1.4 mmHg) condition. After 2 h of saline infusion, CVP was elevated (P = 0.002) to a similar magnitude (P = 0.485) in HDT (DeltaCVP = 2.7 +/- 0.8 mmHg) and control (DeltaCVP = 2.3 +/- 0.8 mmHg) conditions and returned to preinfusion levels 18 h postinfusion in both treatments. PV followed the same pattern as CVP. The response relationships between CVP and UVR and between CVP and UNa shifted to the left with HDT. The restoration of CVP and PV to lower preinfusion levels after volume loading in HDT compared with control supports the notion that lower CVP during HDT may reflect a new operating point about which vascular volume is regulated. These results may explain the ineffective fluid intake procedures currently employed to treat patients and astronauts.

NASA Discipline Cardiopulmonary↗

Pressure-driven stochastization of flux surfaces in stellarator equilibria: a review of the experimental observations and their analysis

Stellarator vacuum fields are designed to have a dense set of nested flux surfaces, with only small islands and stochastic regions in the interior of the confinement region. As the plasma pressure is increased, pressure driven currents appear, and they can significantly modify the vacuum field. The question arises whether pressure driven currents can cause significant flux surface breakage. Both the Wendelstein 7-AS and large helical device stellarators had dedicated experimental campaigns to study the β limit in those devices. In this paper, we review the evidence that the flux surfaces in a significant fraction of the plasma volume were stochastized by the pressure-driven currents in the highest β experiments. That phenomenon appears to have been the dominant source of pressure-driven flux surface loss in these experiments.

stellarator equilibrium↗

Effect of simulated weightlessness on exercise-induced anaerobic threshold

The effect of simulated weightlessness, induced by ten days of continuous bedrest (BR) in the -6 deg head-down position, on the exercise-induced anaerobic threshold (AT) was determined by comparing specific ventilatory and gas-exchange measurements during an incremental ergometer test performed before and after BR. The primary index for determining the exercise-induced AT values of each subject was visual identification of the workrate or oxygen uptake (VO2) at which the ratio of the expired minute ventilation volume (VE) to VO2 exhibited a systematic increase without a concomitant increase in the VE/VCO2 value. Following BR, the mean VO2max of the subjects decreased by 7.0 percent, and the AT decreased from a mean of 1.26 L/min VO2 before BR to 0.95 L/min VO2 after BR. The decrease in AT was manifested by a decrease in both absolute and relative workrates. The change in AT correlated significantly with the change in plasma volume but not with the change in VO2max. The results suggest that the reduction in AT cannot be completely explained by the reduction in VO2, and that the AT decrease is associated with the reduction in intravascular fluid volume.

Convertino, V. A.↗

Role of thermal and exercise factors in the mechanism of hypervolemia

The present study was undertaken to determine whether the chronic increase in plasma volume, resulting from heat exposure and exercise training, was due only to elevated rectal temperature or whether there were additional nonthermal factors related to the exercise. The study was conducted on eight volunteer, healthy, moderately trained male college subjects (18-26 yr). Exercise-induced hypervolemia was associated with thermal factor(s) that contributed 40% and nonthermal factors that accounted for the remaining 60%. In addition, some nonthermal, exercise-induced factors were twofold increases in plasma osmotic and vasopressin levels during exercise, and a fivefold increase in resting plasma protein content.

Convertino, V. A.↗

Adaptation of Baroreflexes and Orthostatic Hypotension

The footward shift of blood volume and compensatory autonomic reflex responses initiated during the assumption of the upright posture in terrestrial gravity is a common feature in humans. When regular exposure to upright posture is removed, the headward redistribution of blood induces numerous physiological adaptations which compromise this normal response and the development of low blood pressure upon standing (orthostatic hypotension) can ensue. Such microgravity conditions can be produced by prolonged exposure to spaceflight or prolonged bed rest. Since the reduction of blood and plasma volume during exposure to microgravity has been associated with orthostatic instability following spaceflight and bed rest, it has been a reasonable assumption that hypovolemia may be a primary contributing factor to the development of orthostatic hypotension. This view was supported by the observation that the attempt to restore vascular volume in astronauts by drinking saline solutions just prior to re-entry had proven effective in reducing orthostatic instability after spaceflights of short duration. However, as the duration of spaceflight lengthens, orthostatic instability persists despite fluid loading procedures, suggesting that mechanisms other than hypovolemia may contribute to orthostatic hypotension following prolonged exposure to microgravity conditions. Recent evidence has been generated from spaceflight and groundbase experiments that supports the notion that changes in autonomic baroreflexes that control cardiac and vascular responses during orthostatic challenges may be affected by longer periods of microgravity exposure and can contribute to postflight orthostatic instability.

Convertino, Victor A.↗

Validation study of RWM stability in DIII-D high- β N plasmas

The n = 1 (n is the toroidal mode number) resistive wall mode (RWM) stability is numerically investigated for two DIII-D high-β N discharges 176440 and 172461, utilizing the MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) and MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) codes. Systematic validation efforts are attempted, for the first time, for discharges with very slow or vanishing toroidal flow for a large fraction of the plasma volume. While gaining physics insights in accessing stable operation regime at β N exceeding the Troyon no-wall limit in these slow-rotation experiments, the predictive capability of fluid and non-perturbative magnetohydrodynamic-kinetic hybrid models for the RWM is further confirmed. The MARS-F fluid model, with a strong but numerically tunable viscosity mimicking ion Landau damping of parallel sound waves, finds complete stabilization of the n = 1 RWM in the considered DIII-D plasmas under the experimental flow conditions. Similarly, either full stabilization (for discharge 176440) or marginal stability (for discharge 172461) of the mode is computed by the MARS-K hybrid model, which is first-principle based without free model parameters. In particular, all drift kinetic resonances, including those of thermal and energetic particles, are found to synergistically act to marginally stabilize the RWM in discharge 172461. These MARS-F/K modeling results explain the experimentally observed stable operational regime in DIII-D, as far as the RWM stability is concerned. Extensive numerical sensitivity studies, with respect to the plasma toroidal flow speed as well as the radial location of the resistive wall, are also carried out to further support the validation study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans

Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.

Convertino, V. A.↗

Blood and urine responses to ingesting fluids of various salt and glucose concentrations

To compensate for the reduced blood and fluid volumes that develop during weightlessness, the Space Shuttle crewmembers consume salt tablets and water equivalent to 1 l of normal saline, about 2 hrs before landing. This paper compares the effects on blood, urine, and cardiovascular variables of the ingestion of 1 l of normal (0.9 percent) saline with the effects of distilled water, 1 percent glucose, 0.74 percent saline with 1 percent glucose, 0.9 percent saline with 1 percent glucose, and 1.07 percent saline. It was found that the expansion of plasma volume and the concentration of urine were greater 4 hrs after ingestion of 1.07 percent saline solution than after ingestion of normal saline and that the solutions containig glucose did not enhance any variables as compared with normal saline.

Frey, Mary A.↗

Effect of hypovolemia, infusion, and oral rehydration on plasma electrolytes, ADH, renin activity, and +G/z/ tolerance

Effects on plasma volume, electrolyte shifts, and +G(z) tolerance induced by: (1) blood withdrawal; (2) blood infusion; and (3) oral fluid intake, were determined at 0.5 G/min in centrifugation tests of six ambulatory male patients, aged 21 to 27 yrs. Hypovolemia induced by withdrawal of 400 ml blood, blood infusion followed by repeated centrifugation, effects of consuming an isotonic drink (0.9% NaCl) to achieve oral rehydration, and donning of red adaptation goggles were studied for effects on acceleration tolerance, pre-acceleration and post-acceleration plasma renin activity (PRA) and plasma vasopressin levels. No significant changes in post-acceleration PRA compared to pre-acceleration PRA were found, and administration of oral rehydration is found as effective as blood replacement in counteracting hypovolemic effects.

Greenleaf, J. E.↗

Cardiovascular function following reduced aerobic activity

PURPOSE: The aim of this study was to test the hypothesis that a sustained reduction of physical activity (deconditioning) would alter the cardiovascular regulatory function. METHODS: Nineteen young, healthy volunteers participated in physical deconditioning for a period of 8 wk. Before (pre) and following (post) physical deconditioning, the responses of heart rate (HR), mean arterial pressure (MAP, measured by Finapres), central venous pressure (CVP), stroke volume (SV, Doppler), and forearm blood flow (FBF, plethysmography) were determined during lower body negative pressure (LBNP). The carotid baroreflex (CBR) function was assessed using a train of pulsatile neck pressure (NP) and suction, and the aortic baroreflex control of HR was assessed during steady-state phenylephrine (PE) infusion superimposed by LBNP and NP to counteract the PE increased CVP and carotid sinus pressure, respectively. RESULTS: Active physical deconditioning significantly decreased maximal oxygen uptake (-7%) and LBNP tolerance (-13%) without a change in baseline hemodynamics. Plasma volume (-3% at P = 0.135), determined by Evans Blue dilution, and blood volume (-4% at P = 0.107) were not significantly altered. During LBNP -20 to -50 torr, there was a significantly greater drop of SV per unit decrease in CVP in the post- (14.7 +/- 1.6%/mm Hg) than predeconditioning (11.2 +/- 0.7%/mm Hg) test accompanied by a greater tachycardia. Deconditioning increased the aortic baroreflex sensitivity (pre vs post: -0.61 +/- 0.12 vs -0.84 +/- 0.14 bpm.mm-1 Hg, P = 0.009) and the slope of forearm vascular resistance (calculated from [MAP-CVP]/FBF) to CVP (-2.75 +/- 0.26 vs -4.94 +/- 0.97 PRU/mm Hg, P = 0.086). However, neither the CBR-HR (-0.28 +/- 0.03 VS -0.39 +/- 0.10 bpm.mm-1 Hg) nor the CBR-MAP (-0.37 +/- 0.16 vs -0.25 +/- 0.07 mm Hg/mm Hg) gains were statistically different between pre- and postdeconditioning. CONCLUSIONS: We concluded that the functional modification of the cardiac pressure-volume relationship resulted in the reduced LBNP tolerance, despite the accentuated aortic and cardiopulmonary baroreflex function following deconditioning.

Non-NASA Center↗

The DESC stellarator code suite. Part 1. Quick and accurate equilibria computations

Three-dimensional equilibrium codes are vital for stellarator design and operation, and high-accuracy equilibria are also necessary for stability studies. This paper details comparisons of two three-dimensional equilibrium codes: VMEC, which uses a steepest-descent algorithm to reach a minimum-energy plasma state, and DESC, which minimizes the magnetohydrodynamic (MHD) force error in real space directly. Accuracy as measured by satisfaction of MHD force balance is presented for each code, along with the computation time. It is shown that DESC is able to achieve more accurate solutions, especially near axis. The importance of higher-accuracy equilibria is shown in DESC's better agreement of stability metrics with asymptotic formulae. DESC's global Fourier–Zernike basis also yields solutions with analytic derivatives explicitly everywhere in the plasma volume, provides improved accuracy in the radial direction versus conventional finite differences and allows for exponential convergence. Further, DESC can compute a solution with the same accuracy as VMEC in order-of-magnitude less time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic electromagnetic particle simulations in triangular meshes with C1 finite elements

The triangular mesh-based gyrokinetic scheme enables comprehensive axis-to-edge studies across the entire plasma volume. Our approach employs triangular finite elements with first-derivative continuity (C1), building on previous work to facilitate gyrokinetic simulations. Additionally, we have adopted the mixed variable/pullback scheme for gyrokinetic electromagnetic particle simulations. The filter-free treatment in the poloidal cross-section with triangular meshes introduces unique features and challenges compared to previous treatments using structured meshes. Our implementation has been validated through benchmarks using ITPA-toroidicity-induced Alfvén eigenmode parameters, showing its capability in moderate to small electron skin depth regimes. Additional examinations using experimental parameters confirm its applicability to realistic plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orthostatic stress is necessary to maintain the dynamic range of cardiovascular control in space

In the upright position, gravity fills the low-pressure systems of human circulation with blood and interstitial fluid in the sections below the diaphragm. Without gravity one pressure component in the vessels disappears and the relationship between hydrostatic pressure and oncotic pressure, which regulates fluid passage across the capillary endothelium in the terminal vascular bed, shifts constantly. The visible consequences of this are a puffy face and "bird" legs. The plasma volume shrinks in space and the range of cardiovascular control is reduced. When they stand up for the first time after landing, 30-50% of astronauts suffer from orthostatic intolerance. It remains unclear whether microgravity impairs cardiovascular reflexes, or whether it is the altered volume status that causes the cardiovascular instability following space flight. Lower body negative pressure was used in several space missions to stimulate the cardiovascular reflexes before, during and after a space flight. The results show that cardiovascular reflexes are maintained in microgravity. However, the astronauts' volume status changed in space, towards a volume-retracted state, as measurements of fluid-regulating hormones have shown. It can be hypothesized that the control of circulation and body fluid homeostasis in humans is adapted to their upright posture in the Earth's gravitational field. Autonomic control regulates fluid distribution to maintain the blood pressure in that posture, which most of us have to cope with for two-thirds of the day. A determined amount of interstitial volume is necessary to maintain the dynamic range of cardiovascular control in the upright posture; otherwise orthostatic intolerance may occur more often.

manned↗

Effects of thermal stress and exercise on blood volume in humans

The available experimental data base on the effects of exercise, posture and the environment (heat) on the blood volume, composition and concentration in humans is surveyed in depth to synthesize supportable conclusions. A large disparity is noted in the effective controls which were initiated in previous experimental conditions, resulting in contradictory findings regarding, e.g., hemoconcentrations and hemodilution in response to exercise. Comparisons between the results of exercise and of supine, seated and upright subjects has underscored the importance of gravity in hemoconcentration, particularly in the legs, and the generation of aldotestosterone. Hemoconcentration has been confirmed to increase with exercise in a seated or supine position. Exercise in a heated environment transfers cardiac output from core areas and reduces filtration efficiencies. Also, plasma volume increases, an action which cannot yet be associated with crystalloidal or colloidal influences on the osmotic behavior of cell walls.

Harrison, M. H.↗

Modeling of Macroscopic Dynamics in Three-Dimensional Plasma Configurations (Final Technical Report)

A numerical simulation-based study to investigate the stability properties of inherently three-dimensional plasma magnetic configurations is presented. These configurations, called stellarators and heliotrons, use external helical coils to provide the twisting magnetic field that is required to confine ionized plasma particles. In contrast to the tokamak configuration, which nominally has the property of axisymmetry, electrical current does not need to be induced in stellarator and heliotron plasma. Experiments have shown that these three-dimensional configurations are remarkably robust to macroscopic instability, even when driven to relatively high levels of plasma pressure. Our understanding of how the plasma is able to withstand macroscopic instability will be enhanced by the work proposed here. The effort will generalize existing numerical modeling capability, and it will apply the new capability to model macroscopic dynamics in these three-dimensional configurations. The development work has been applied to the NIMROD simulation code (https://nimrodteam.org) that was originally based on axisymmetric problem domains. It has been generalized to accommodate the three-dimensional shaping of the plasma volume in stellarators and heliotrons. Its use of equilibrium data has also been generalized, and the implementation allows different numerical representation of the magnetic field. Analysis has been performed to inform the selection of numerical methods, and a method to accelerate the iterative solution of the necessary algebraic systems has been developed and implemented. Verification of the new NIMSTELL code on benchmark problems has also been an important part of the effort.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Islands and current singularities in quasisymmetric toroidal plasmas

The presence of current singularities in a quasisymmetric magnetic field is explored. Quasisymmetry is shown effective in isolating Pfirsch–Schlüter singularities, to leading order, to a single magnetic surface resonant with the helicity of the symmetry. The effects of pressure driven currents are analyzed, indicating that exclusion of this surface from the plasma volume reduces the potential opening of islands but does not generally eliminate them completely due to higher order asymmetric geometric effects. These three-dimensional effects are contained in quasisymmetry and indicate the complexity of finding consistent solutions and their potential sensitivity. The δ-function current singularities show a distinct quasisymmetric behavior only when the higher-order Fourier content of B is relevant for the resistive stability parameter D R (not included in leading-order near-axis expansions). In such scenarios, quasisymmetry proves advantageous, both in simplicity and avoidance of amplification by low-order rational surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗