Search NASA⌕ Search

SEARCH · Search NASA

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An Interface for Specifying Rigid-Body Motions for CFD Applications

An interface for specifying rigid-body motions for CFD applications is presented. This interface provides a means of describing a component hierarchy in a geometric configuration, as well as the motion (prescribed or six-degree-of-freedom) associated with any component. The interface consists of a general set of datatypes, along with rules for their interaction, and is designed to be flexible in order to evolve as future needs dictate. The specification is currently implemented with an XML file format which is portable across platforms and applications. The motion specification is capable of describing general rigid body motions, and eliminates the need to write and compile new code within the application software for each dynamic configuration, allowing client software to automate dynamic simulations. The interface is integrated with a GUI tool which allows rigid body motions to be prescribed and verified interactively, promoting access to non-expert users. Illustrative examples, as well as the raw XML source of the file specifications, are included.

Murman, Scott M.↗

System Levelized Cost of Energy Analysis for Floating Offshore Vertical-Axis Wind Turbines

The levelized cost of energy for an offshore wind plant consisting of floating vertical-axis wind turbines is studied in this report. A 5 MW Darrieus vertical-axis wind turbine rotor is used as the study turbine as this architecture was determined to have the greatest ability to reduce the system cost. The rotor structural design was used with blade manufacturing cost model studies to estimate its cost. A two-bladed, carbon fiber rotor was selected in this analysis since the lower topside mass resulted in a reduction of the platform costs which exceeded the increased rotor cost. A direct-drive, medium efficiency drivetrain was designed which represents 25% of the costs and 45% of the mass of the combined rotor/drivetrain system. A direct-drive, permanent magnet generator drivetrain was selected due to the improved reliability of this type of system, while the cost was not significantly higher than for geared drivetrains. A platform was designed by first identifying the optimal architecture for the vertical-axis wind turbine at a water depth of 150 m. A survey was performed of floating platform types, and six characteristic designs were analyzed which span the range of stability mechanisms available to floating systems. A multi-cellular tension-leg platform was identified as the lowest cost platform which additionally provided some interesting performance benefits. The small motions of the tension-leg platform benefit the system energy capture while limiting inertial loads placed on the rotor’s tower and blades. A final design was produced for the multi-cellular tension-leg platform considering operational fatigue, storm wind and wave conditions, and tow-out design cases. The driving design load was stability during tow-out while ballasting the platform. System levelized cost of energy was calculated, including operational expenses and balance of system costs estimated for the wind plant. Opportunities for reduction in the component costs are predicted and used to make projections of the system levelized cost of energy for future developments. The opportunities and challenges for floating vertical-axis wind turbines are identified by the system design and levelized cost of energy analysis.

17 WIND ENERGY↗

Voyager engineering improvements for Uranus encounter

Engineering changes made on the Voyager spacecraft during their explorations of the outer solar system are discussed. A recovery from a scan actuator fault, achieved by ground testing, in flight capability enhancement and testing, conservation of actuator usage and a set of contingency plans to substitute roll motion of the spacecraft for motion of the scan platform in the AZ direction, is discussed. General engineering improvements made are addressed, including a scan platform anticreep patch modification, an improvement of dynamic performance during maneuvers, and adaptive control of the attitude control deadband. Changes made in the power management are described. Finally, engineering improvements made in order to enhance scientific findings at the Uranus encounter are reviewed in detail. The two most important were the increased gyro drift turn rate capability to accommodate image motion compensation for the close fly-by of Miranda and the reduction in spacecraft rates to accommodate increased imaging exposure times without incurring excessive image smear.

Marderness, H. P.↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Optical alignment of Centaur's inertial guidance system

During Centaur launch operations the launch azimuth of the inertial platform's U-accelerometer input axis must be accurately established and maintained. This is accomplished by using an optically closed loop system with a long-range autotheodolite whose line of sight was established by a first-order survey. A collimated light beam from the autotheodolite intercepts a reflecting Porro prism mounted on the platform azimuth gimbal. Thus, any deviation of the Porro prism from its predetermined heading is optically detected by the autotheodolite. The error signal produced is used to torque the azimuth gimbal back to its required launch azimuth. The heading of the U-accelerometer input axis is therefore maintained automatically. Previously, the autotheodolite system could not distinguish between vehicle sway and rotational motion of the inertial platform unless at least three prisms were used. One prism was mounted on the inertial platform to maintain azimuth alignment, and two prisms were mounted externally on the vehicle to track sway. For example, the automatic azimuth-laying theodolite (AALT-SV-M2) on the Saturn vehilce used three prisms. The results of testing and modifying the AALT-SV-M2 autotheodolite to simultaneously monitor and maintain alignment of the inertial platform and track the sway of the vehicle from a single Porro prism.

Gordan, Andrew L.↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

60 APPLIED LIFE SCIENCES↗

Visualization and 3D Mesh Generation for ASSEMBLERS Range of Motion

In an effort to create a base and foundation for ASSEMBLERS with an informed layout, data representing the range of motion of varying heights of Stewart platforms were analyzed. 3D shapes were generated first to be approximately representative of these data in the form of rotationally symmetric shells, making use of 2D alpha shapes to create a border that did not account for asymmetry inherent in the true range of motion. Further work was performed to generate mesh files more fully representative of reach, creating 3D alpha shapes based directly on point clouds generated from uniformly random platform positions. These shapes were initially not representative of the entire range of motion of a platform stack due to the low likelihood of the most extreme positions being added to a given point cloud but were more representative of the asymmetry inherent in the possible positions of a Stewart platform as they no longer relied on a single 2D contour. The same algorithm for generating 3D alpha shapes was then applied to point clouds designed to represent extreme positions, generating larger smooth shells with six clear planes of symmetry. All shells were converted to STLs to aid in further modeling of range of motion for base layouts and in visualizing reachable area for varying stack heights, successfully creating closed shells representative of typical and extreme positions for platform stacks of varying heights.

Jonah DeGuire Vanke↗

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo↗

TU-CD-304-02: Planning and Delivery of Fully Dynamic Trajectory Modulated Arc Therapy On Pituitary Adenoma: Dosimetric Advantages Over Conventional Volumetric Modulated Arc Therapy

Purpose: To assess the potential benefit of trajectory modulated arc therapy (TMAT) for treatments of small benign intracranial tumor, pituitary adenoma. Methods: A TMAT planning platform that incorporates complex source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement was used for the study. The platform couples an interactive trajectory generation tool with a VMAT algorithm that performs multi-resolution, progressive sampling MLC optimization on a user-designed trajectory. A continuous couch rotation of 160° angular span with ±20° mini gantry arcs was used to emulate a non-coplanar horizontal arc-like trajectory. Compared to conventional non-coplanar gantry arcs (60°-100° gantry rotation with couch kicks), TMAT limited the unnecessary low to medium dose spread in the anterior and posterior directions, where primary OARs (e.g., brainstem, optic chiasm, optic nerves, and lens) are in close proximity to the targeted pituitary tumor volume. For 5 standard fractionation pituitary adenoma cases (50.4Gy/28fractions), TMAT and non-coplanar VMAT plans were generated and compared under equivalent objectives/constraints. TMAT delivery was implemented and demonstrated on Varian TrueBeam via XML scripts. Results: Both techniques showed good target coverage while OARs were able to meet the constraints on QUANTEC guidelines. Notably, TMAT decreased the dose deposition in the anterior-to-posterior direction surrounding PTV. TMAT significantly reduced the mean doses on brainstem, optic nerves, eyes and lens by 47.29%±13.17%, 28.51%±8.68%, 80.82%±8.71% and 65.38%±19.99% compared with VMAT, all p≤0.01. Percentage reductions of maximum point dose in eyes and lens were 75.68%±10.30% and 70.72%±18.62% respectively for TMAT versus VMAT, all p≤0.01. A representative isocentric TMAT pituitary plan was delivered via an XML script with 200 control points and 282 MUs. Conclusion: Deliverable TMAT plans were achieved in developer mode in TrueBeam. TMAT was shown to be superior for pituitary adenoma irradiation in terms of OARs sparing.

60 APPLIED LIFE SCIENCES↗

Ground Simulation of an Autonomous Satellite Rendezvous and Tracking System Using Dual Robotic Systems

A hardware-in-the-loop ground system was developed for simulating a robotic servicer spacecraft tracking a target satellite at short range. A relative navigation sensor package "Argon" is mounted on the end-effector of a Fanuc 430 manipulator, which functions as the base platform of the robotic spacecraft servicer. Machine vision algorithms estimate the pose of the target spacecraft, mounted on a Rotopod R-2000 platform, relay the solution to a simulation of the servicer spacecraft running in "Freespace", which performs guidance, navigation and control functions, integrates dynamics, and issues motion commands to a Fanuc platform controller so that it tracks the simulated servicer spacecraft. Results will be reviewed for several satellite motion scenarios at different ranges. Key words: robotics, satellite, servicing, guidance, navigation, tracking, control, docking.

Trube, Matthew J.↗

A fast band–Krylov eigensolver for macromolecular functional motion simulation on multicore architectures and graphics processors

We introduce a new iterative Krylov subspace-based eigensolver for the simulation of macromolecular motions on desktop multithreaded platforms equipped with multicore processors and, possibly, a graphics accelerator (GPU). The method consists of two stages, with the original problem first reduced into a simpler band-structured form by means of a high-performance compute-intensive procedure. This is followed by a memory-intensive but low-cost Krylov iteration, which is off-loaded to be computed on the GPU by means of an efficient data-parallel kernel. The experimental results reveal the performance of the new eigensolver. Concretely, when applied to the simulation of macromolecules with a few thousands degrees of freedom and the number of eigenpairs to be computed is small to moderate, the new solver outperforms other methods implemented as part of high-performance numerical linear algebra packages for multithreaded architectures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Many-isocenter optimization for robotic radiotherapy

Despite significant dosimetric gains, clinical implementation of the 4π non-coplanar radiotherapy on the widely available C-arm gantry system is hindered by limited clearance, and the need to perform complex coordinated gantry and couch motion. A robotic radiotherapy platform would be conducive to such treatment but a new conflict between field size and MLC modulation resolution needs to be managed for versatile applications. This study investigates the dosimetry and delivery efficiency of purposefully creating many isocenters to achieve simultaneously high MLC modulation resolution and large tumor coverage. An integrated optimization framework was proposed for simultaneous beam orientation optimization (BOO), isocenter selection, and fluence map optimization (FMO). The framework includes a least-square dose fidelity objective, a total variation term for regularizing the fluence smoothness, and a group sparsity term for beam selection. A minimal number of isocenters were identified for efficient target coverage. Colliding beams excluded, high-resolution small-field 4π intensity-modulated radiotherapy (IMRT) treatment plans with 50 cm source-to-isocenter distance (SID-50) on 10 Head and Neck (H&N) cancer patients were compared with low-resolution large-field plans with 100 cm SID (SID-100). With the same or better target coverage, the average reduction of [Dmean, Dmax] of 20-beam SID-50 plans from 20-beam SID-100 plans were [2.09 Gy, 1.19 Gy] for organs at risk (OARs) overall, [3.05 Gy, 0.04 Gy] for parotid gland, [3.62 Gy, 5.19 Gy] for larynx, and [3.27 Gy, 1.10 Gy] for mandible. R50 and integral dose were reduced by 5.3% and 9.6%, respectively. Wilcoxon signed-rank test showed significant difference (p < 0.05) in planning target volume (PTV) homogeneity, PTV Dmax, R50, Integral dose, and OAR Dmean and Dmax. The estimated delivery time of 20-beam [SID-50, SID-100] plans were [19, 18] min and [14, 9] min, assuming 5 fractions and 30 fractions, respectively. Finally, with clinically acceptable delivery efficiency, many-isocenter optimization is dosimetrically desirable for treating large targets with high modulation resolution on the robotic platform.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seakeeping considerations in the employment of V/STOL on Naval ships

Compatibility of Naval ships as V/STOL support platforms and the ship motions that V/STOL aircraft must endure are discussed. A methodology which evaluates the impact of motion criteria such as the maximum ship motion allowable during V/STOL landing/launch is presented. Emphasis is given to design alternatives that reduce ship motion.

Olson, S. R.↗

Fast Plasma Instrument for MMS: Data Compression Simulation Results

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eights (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 deg x 180 deg fields-of-view (FOV) are set 90 deg apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 deg x 180 deg fan about its nominal viewing (0 deg deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the results in the DES complement of a given spacecraft generating 6.5-Mbs(exp -1) of electron data while the DIS generates 1.1-Mbs(exp -1) of ion data yielding an FPI total data rate of 6.6-MBs(exp -1). The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. Currently, the FPI data rate allocation to the CIDP is 1.5-Mbs(exp -1). Consequently, the FPI-IDPU must employ data/image compression to meet this CIDP telemetry allocation. Here, we present simulations of the CCSDS 122.0-B-1 algorithm-based compression of the FPI-DES electron data. Compression analysis is based upon a seed of re-processed Cluster/PEACE electron measurements. Topics to be discussed include: review of compression algorithm; data quality; data formatting/organization; and, implications for data/matrix pruning. To conclude a presentation of the base-lined FPI data compression approach is provided.

Barrie, A.↗

Fast Plasma Instrument for MMS: Simulation Results

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. The Dual Electron Spectrometer (DES) of the Fast Plasma Instrument (FPI) for MMS meets these demanding requirements by acquiring the electron velocity distribution functions (VDFs) for the full sky with high-resolution angular measurements every 30 ms. This will provide unprecedented access to electron scale dynamics within the reconnection diffusion region. The DES consists of eight half-top-hat energy analyzers. Each analyzer has a 6 deg. x 11.25 deg. Full-sky coverage is achieved by electrostatically stepping the FOV of each of the eight sensors through four discrete deflection look directions. Data compression and burst memory management will provide approximately 30 minutes of high time resolution data during each orbit of the four MMS spacecraft. Each spacecraft will intelligently downlink the data sequences that contain the greatest amount of temporal structure. Here we present the results of a simulation of the DES analyzer measurements, data compression and decompression, as well as ground-based analysis using as a seed re-processed Cluster/PEACE electron measurements. The Cluster/PEACE electron measurements have been reprocessed through virtual DES analyzers with their proper geometrical, energy, and timing scale factors and re-mapped via interpolation to the DES angular and energy phase-space sampling measurements. The results of the simulated DES measurements are analyzed and the full moments of the simulated VDFs are compared with those obtained from the Cluster/PEACE spectrometer using a standard quadrature moment, a newly implemented spectral spherical harmonic method, and a singular value decomposition method. Our preliminary moment calculations show a remarkable agreement within the uncertainties of the measurements, with the results obtained by the Cluster/PEACE electron spectrometers. The data analyzed was selected because it represented a potential reconnection event as currently published.

Figueroa-Vinas, Adolfo↗

Fast Plasma Investigation for MMS: Simulation of the Burst Triggering System

The Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eight (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 degree x 180 degree fields-of-view (FOV) are set 90 degrees apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 degree x 180 degree fan about the its nominal viewing (0 deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the diffusion regions of reconnection, the highest temporal/spatial resolution mode of FPI results in the DES complement of a given spacecraft generating 6.5-Mb (raised dot) per second of electron data while the DIS generates 1.1-Mb (raised dot) per second of ion data yielding an FPI total data rate of 6.6-Mb (raised dot) per second. The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. This requires a data ranking process known as the burst trigger system. The burst trigger system uses pseudo physical quantities to approximate the local plasma environments. As each pseudo quantity will have a different value, a set of two scaling factors is employed for each pseudo term. These pseudo quantities are then combined at the instrument, spacecraft, and observatory level leading to a final ranking of data based on expected scientific interest. Here, we present simulations of the fixed point burst trigger system for the FPI. A variety of data sets based on previous mission data as well as analytical formulations are tested. Comparisons of floating point calculations versus the fixed point hardware simulation are shown. Analysis of the potential sources of error from overflows, quantization, etc. are examined and mitigation methods are presented. Finally a series of calibration curves are presented, showing the expected error in pseudo quantities based solely on the scale parameters chosen and the expected data range. We conclude with a presentation of the current base-lined FPI burst trigger approach.

Barrie, A. C.↗

Slice-Write

SAND2022-1477 O Slice-Write is an extremely powerful toolpath generation technology for the extrusion 3D printing community. This application was developed as a standalone post-processor capable of interpreting and translating gcode output from Ultimaker Cura, an open-source slicing application for additive manufacturing, not designed or intended for direct ink write (DIW) printing. Slice-Write can convert output gcode from Cura into a format compatible with Aerotech-based motion control DIW printing platforms. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Roach, Devin↗