Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Mechanistic Study of Nucleate Boiling Under Microgravity Conditions

The overall objective of this work is to study nucleate boiling heat transfer under microgravity conditions in such a way that while providing basic knowledge of the phenomena, it also leads to development of simulation models and correlations that can be used as design tools for a wide range of gravity levels. In the study a building block type of approach is used and both pool and low velocity flow boiling are investigated. Starting with experiments using a single bubble, the complexity of the experiments is increased to two or three inline bubbles, to five bubbles placed on a two-dimensional grid. Finally, experiments are conducted where a large number of prescribed cavities nucleate on the heater and when a commercial surface is used. So far experiments have been conducted at earth normal gravity and in the reduced gravity environment of the KC-135 aircraft whereas experiments on the space station are planned. Modeling/complete numerical simulation of the boiling process is an integral part of the total effort. Experiments conducted with single bubbles formed on a nucleation site microfabricated on a polished silicon wafer show that for gravity levels (g) varying from 1.5g(sub e) to 0.01g(sub e), the bubble diameter at departure varies approximately as (g(sub e)/g)(exp 1/2) and the growth period as (g(sub e)/g). When bubbles merge either inline or in a plane, the bubble diameter at departure is found to be smaller than that obtained for a single bubble and shows a weaker dependence on the level of gravity. The possible reason is that as the bubbles merge they create fluid circulation around the bubbles, which in turn induces a lift force that is responsible for the earlier departure of the bubbles. The verification of this proposition is being sought through numerical simulations. There is a merger of two inline, three inline, and several bubbles in a plane in the low gravity environment of the KC-135 aircraft. After merger and before departure, a mushroom type of bubble with several stems attached to the heater surface is clearly evident. Local heat fluxes during growth and departure of a single bubble were also measured. It was found that during most of the growth period of the bubble, generally the wall heat flux decreased with time because of the increased dry area under the bubble. However, the heat flux increased rapidly just prior to departure of the bubble because of the transient conduction into the cold liquid rushing to fill the space vacated by the bubble as the bubble base shrinks. The measured heat fluxes at various radial locations are found to be in qualitative agreement with the numerical predictions. Single bubble studies at earth normal gravity have also been performed on surfaces oriented at different angles to the gravitational acceleration with flow parallel to the surface. It is found that in all cases the bubbles slide along the surface before lift-off from the surface. The lift force generated as a result of the relative motion between the sliding bubbles and the imposed flow is found to play an important role when the normal force due to buoyancy is reduced. An experimental apparatus for the study of the bubble behavior with imposed flow under reduced gravity conditions has been developed and will soon be employed for experiments in the KC-135 aircraft.

Dhir, V. K.↗

Twenty years of dry interim storage of spent nuclear fuel (SNF) in Germany- History and developments - 15575

According to article 6 of the German Atomic Energy Act, storage of nuclear fuel requires a license granted by the competent authority in this field, which is the Federal Office of Radiation Protection. In 1983 a license to store spent nuclear fuel (SNF) and later expanded for vitrified high level waste (HAW) for the interim storage facility in Gorleben was granted. Dry Interim storage at the NPP sites in its actual form started in 2002 in the interim storage facility next to the NPP Lingen. Since this time each NPP erected its own storage facility and three central storage facilities have been built. All of these facilities use dry storage in metallic casks. The actual storage licenses for SNF and the HAW (which is stored in Gorleben and Rubenow) are limited to 40 years starting with the first cask emplacement. As no opening of the cask is intended during the storage period the condition of the inventory and the cask before loading has to be known in detail. This requires for instance detailed knowledge of the history of the SNF loaded as well as supervision of the manufacturing process of the cask. Within the last twenty years several mishaps influenced the regulatory point of view. During a loading campaign in a boiling water reactor traces of pool water remained in the gasket slot and during the drying procedure crystalline boron salts prevented the required tightness. After that event a long-term experiment was started and is still going on which studies the effects of water and minor damages to the gasket. As well changes in the loading procedure have been introduced. The pressure switch used to monitor the pressure in the space between primary and secondary lid has a self surveillance function. This indicated a malfunction 23 times in the last twenty years. Examinations of all events indicated no systematic failure, but a weak point seems to be the plug-in connection. The manufacturer introduced some modifications to improve the system. Introduction of FEM methods in safety analysis to amend the existing methods of testing allowed a new view on and in the cask safety analysis. Progress in this field is closely connected to the available computing capacity and stipulates experts to ongoing improvement. After expiring of the storage license which will be the case for the first cask loaded in 1992 and stored in Ahaus 2032 an extension or a new license can only be granted if the at this time relevant requirements are met. This will require detailed knowledge about the happenings and accidents during the previous storage period. All experience of the periodic safety assessment (PSA) which started in 2013 and accompanying experiments conducted till now and during the licensed storage time will be needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-test examination of a pool boiler receiver

A subscale pool boiler test apparatus to evaluate boiling stability developed a leak after being operated with boiling NaK for 791.4 hr at temperatures from 700 to 750 C. The boiler was constructed using Inconel 625 with a type 304L stainless steel wick for the boiler and type 316 stainless steel for the condenser. The boiler assembly was metallurgically evaluated to determine the cause of the leak and to assess the effects of the NaK on the materials. It was found that the leak was caused by insufficient (about 30 pct.) joint penetration in a butt joint. There was no general corrosion of the construction materials, but the room temperature ductility of the Inconel 625 was only about 6.5 pct. A crack in the heat affected zone of the Inconel 625 near the Inconel 625 to type 316 stainless steel butt joint was probably caused by excessive heat input. The crack was observed to have a zone depleted of iron at the crack surface and porosity below that zone. The mechanism of the iron depletion was not conclusively determined.

Dreshfield, Robert L.↗

MELCOR Model of the Spent Fuel Pool of Fukushima Dai-ichi Unit 4

Unit 4 of the Fukushima Dai-ichi Nuclear Power Plant suffered a hydrogen explosion at 6:00 am on March 15, 2011, exactly 3.64 days after the earthquake hit the plant and the off-site power was lost. The earthquake occurred on March 11 at 2:47 pm. Since the reactor of this Unit 4 was defueled on November 29, 2010, and all its fuel was stored in the spent fuel pool (SFP4), it was first believed that the explosion was caused by hydrogen generated by the spent fuel, in particular, by the recently discharged core. The hypothetical scenario was: power was lost, cooling to the SFP4 water was lost, pool water heated/boiled, water level decreased, fuel was uncovered, hot Zircaloy reacted with steam, hydrogen was generated and accumulated above the pool, and the explosion occurred. Recent analyses of the radioisotopes present in the water of the SFP4 and underwater video indicated that this scenario did not occur - the fuel in this pool was not damaged and was never uncovered the hydrogen of the explosion was apparently generated in Unit 3 and transported through exhaust ducts that shared the same chimney with Unit 4. This paper will try to answer the following questions: Could that hypothetical scenario in the SFP4 had occurred? Could the spent fuel in the SPF4 generate enough hydrogen to produce the explosion that occurred 3.64 days after the earthquake? Given the magnitude of the explosion, it was estimated that at least 150 kg of hydrogen had to be generated. As part of the investigations of this accident, MELCOR models of the SFP4 were prepared and a series of calculations were completed. The latest version of MELCOR, version 2.1 (Ref. 1), was employed in these calculations. The spent fuel pool option for BWR fuel was selected in MELCOR. The MELCOR model of the SFP4 consists of a total of 1535 fuel assemblies out of which 548 assemblies are from the core defueled on Nov. 29, 2010, 783 assemblies are older assemblies, and 204 are new/fresh assemblies. The total decay heat of the fuel in the pool was, at the time of the accident, 2.284 MWt, of which 1.872 MWt were from the 548 assemblies of the last core discharged and 0.412 MWt were from the older 783 assemblies. These decay heat values were calculated at Oak Ridge National Laboratory using the ORIGEN2.2 code (Ref. 2) - they agree with values reported elsewhere (Ref. 3). The pool dimensions are 9.9 m x 12.2 m x 11.8 m (height), and with the water level at 11.5 m, the pool volume is 1389 m3, of which only 1240 m3 is water, as some volume is taken by the fuel and by the fuel racks. The initial water temperature of the SFP4 was assumed to be 301 K. The fuel racks are made of an aluminum alloy but are modeled in MELCOR with stainless steel and B4C. MELCOR calculations were completed for different initial water levels: 11.5 m (pool almost full, water is only 0.3 m below the top rim), 4.4577 m (top of the racks), 4.2 m, and 4.026 m (top of the active fuel). A calculation was also completed for a rapid loss of water due to a leak at the bottom of the pool, with the fuel rapidly uncovered and oxidized in air. Results of these calculations are shown in the enclosed Table I. The calculation with the initial water level at 11.5 m (full pool) takes 11 days for the water to boil down to the top of the fuel racks, 11.5 days for the fuel to be uncovered, 14.65 days to generate 150 kg of hydrogen and 19 days for the pool to be completely dry. The calculation with the initial water level at 4.4577 m, takes 1.1 days to uncover the fuel and 4.17 days to generate 150 kg of hydrogen. The calculation with the initial water level at 4.02 m takes 3.63 days to generate 150 kg of hydrogen this is exactly the time when the actual explosion occurred in Unit 4. Finally, fuel oxidation in air after the pool drained the water in 20 minutes, generates only 10 kg of hydrogen this is because very little steam is available and Zircaloy (Zr) oxidation with the oxygen of the air does not generate hydrogen. MELCOR calculated water levels and hydrogen generated in the SFP4 as a function of time for initial water levels of 4.457 m, 4.2 m and 4.02 m are shown in Figs. 1 and 2. Water levels increase at the beginning due to the expansion of the water during the heat-up from 301 K to 373 K. Boiling occurs after the water temperature reaches 373 K. The total amount of hydrogen generated is ~2000 kg, this amount includes hydrogen generated from Zr, which is the largest amount (~1580 kg), from stainless steel (~360 kg), and from B4C (~60 kg). In theory, it is possible to generate up to 3.4 kg of hydrogen per assembly (from oxidation of Zr in the fuel cladding and box), or a total of 4,525 kg from the hot 1331 assemblies stored in the SFP4. The hydrogen generated from oxidation of steel and B4C will be additional. So the answers to the questions are YES according to these MELCOR calculations, enough hydrogen (150 kg) could be generated in the SFP4 3.64 days after the earthquake to produce ...

08 HYDROGEN↗

Pool boiler heat transport system for a 25 kWe advanced Stirling conversion system

Experiments to determine alkali metal/enhanced surface combinations that have stable boiling at the temperatures and heat fluxes that occur in the Stirling engine are reported. Two enhanced surfaces and two alkali metal working fluids were evaluated. The enhanced surfaces were an EDM hole covered surface and a sintered-powder-metal porous layer surface. The working fluids tested were potassium and eutectic sodium-potasium alloy (NaK), both with and without undissolved noncondensible gas. Noncondensible gas (He and Xe) was added to the system to provide gas in the nucleation sites, preventing quenching of the sites. The experiments demonstrated the potential of an alkali metal pool boiler heat transport system for use in a solar-powered Stirling engine. The most favorable fluid/surface combination tested was NaK boiling on a -100 +140 mesh 304L stainless steel sintered porous layer with no undissolved noncondensible gas. This combination provided stable, high-performance boiling at the operating temperature of 700 C. Heat fluxes into the system ranged from 10 to 50 W/sq cm. The transition from free convection to nucleate boiling occurred at temperatures near 540 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.

Anderson, W. G.↗

A study of the deposition of carbide coatings on graphite fibers

The chemical vapor deposition of boron carbide and silicon carbide on graphite fibers to increase their electrical resistance was studied. Silicon carbide coatings were applied without degradation of the mechanical properties of the filaments. These coatings typically added 1000 ohms to the resistance of a filament as measured between two mercury pools. When SiC-coated filaments were oxidized by refluxing in boiling phosphoric acid, average resistance increased by an additional 1000 ohms; in addition resistance increases as high as 150 K ohms and breakdown voltages as high as 17 volts were noted. Data on boron carbide coatings indicated that such coatings would not be effective in increasing resistance, and would degrade the mechanical properties.

Suplinskas, R. J.↗

Apparent Monte Carlo Source Convergence Problem with BWR Fuel Depleted with Partial Control Blade Insertion

Oak Ridge National Laboratory (ORNL) and the US Nuclear Regulatory Commission (NRC) have initiated a multiyear project to investigate application of burnup credit (BUC) to boiling-water reactor (BWR) fuel in storage and transportation casks and spent fuel pools (SFPs). Ideally, a single combination of all operating parameters including moderator density and axial burnup profiles, control blade exposure, and others can be identified to allow a simple, bounding approach to BWR BUC. One aspect of this investigation involves examining the effect of control blade insertion during operation on discharged assembly reactivity. In the course of these calculations, an apparent source convergence problem was discovered for fuel that has experienced partial blade insertion for the entire lifetime of the assembly. The source convergence problem appears not to impact k{sub eff}, but it manifests in predictions of the axial fission density profile. This phenomenon is of interest in identifying areas of concern with BWR BUC since it has not been studied as thoroughly as BUC for pressurized-water (PWR) reactor fuel. There may also be interest in this configuration for further study of a realistic source Monte Carlo convergence problem as opposed to some earlier manufactured source convergence problems through careful selection of initial conditions. This summary presents the depletion conditions used to generate the problem, a description of the models, a background based on well-behaved calculations, the identification of the problem, and attempts made to resolve the problem. Only a brief description of the depletion conditions and models is possible within the limited scope of this summary. Finally, conclusions are presented. This summary identifies a source convergence problem in the process of investigating BUC for BWR spent fuel. The depletion scenario which created the depleted fuel and burnable absorber compositions included a control blade inserted in the bottom 14 nodes throughout the entire depletion. This insertion is slightly over half the length of the assembly, and it appears to create two regions of nearly equal reactivity. As expected, one region is near the top of the assembly, and the other region is near the middle of the assembly. This node includes significant {sup 239}Pu generation as a result of rodded operation, but it is also the top node of the full lattice zone. While the calculated k{sub eff} values appear to be statistically equivalent, the axial neutron production profile varies significantly among independent simulations of the same model. A range of standard approaches has been used to attempt to resolve the source convergence problem and determine the true axial neutron production profile. This profile is of interest in cask criticality safety analysis because it influences the interaction among assemblies loaded in the cask. The forthcoming SCALE 6.2 release will include source convergence testing based on Shannon entropy, which may assist in identifying these types of problems in the future. It should be noted that this source convergence problem results from the depletion conditions and the final distribution of fissile and absorber material within the discharged fuel assembly. The results, while entirely generated within the SCALE code system, are representative of any Monte Carlo program attempting to calculate k{sub eff} for such a system. The most important conclusion of this work is that the BUC criticality safety community must be aware of the potential for this type of source convergence problem. Analysts must approach such partially rodded scenarios with caution and critically examine the results. Fortunately, it is extremely unlikely that BWR assemblies would experience the bladed operation necessary to create this particular source convergence problem. These results may also have some bearing on the analysis of PWR BUC for new plant designs such as AP1000 that incorporate significant rodded operations. In a broader context, the source convergence problem identified here could have been magnified if it had occurred in a Monte Carlo depletion simulation. It may be possible to identify this type of problem in a depletion calculation by comparing the apparently converged fluxes between steps to ensure that no oscillations or other serious shifts are occurring. The depletion calculations performed in this work were performed with a two-dimensional deterministic code and are therefore not subject to this problem. These results may also raise questions about the validity of 2D depletion models with extruded geometry in the 3D k{sub eff} calculation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Study of Molten Metallic Fuel Relocation in Sodium-Filled Fuel Structures

The Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) is being developed by Korea Atomic Energy Research Institute (KAERI). While their design incorporates inherent safety features demonstrated in the landmark Shutdown Heat Removal Test (SHRT) conducted at EBR-II including a large pool configuration and uranium alloy fuel, it is still necessary to evaluate metal fuel relocation and theirs consequences in case of postulated core disruptive accidents. Extensive data regarding fuel relocation in sodium from both in-pile and out-of-pile tests were obtained for oxide fuels in the 1960's - 1970's, while few studies of metallic fuel behavior were performed because of concerns that metallic fuel could not achieve high burnup due to the irradiation induced swelling problem. Following new metal fuel design development that mitigated the swelling problem, experiments regarding interaction of molten metal fuels and liquid sodium have been conducted by several researchers. Most studies that were conducted using metal simulants in various liquids concluded that the molten metals were heavily fragmented after liquid contact and the dominant factors governing the fragmentation were superheating and latent heat of fusion of the molten metal fuel. Gabor et al. conducted experiments using kilogram quantities of various molten uranium alloys in an open sodium pool configuration. They found that the metal fuel fragments were basically in forms of filaments and sheets with a high bed voidage in the order of 0.9. Their calculation indicated that the debris beds formed by relocated metal fuels in an open sodium pool would be largely coolable by conduction heat transfer; and even if deep beds were to form, convective heat transfer and boiling heat transfer could preclude further melt penetration. Although Gabor's tests are useful in evaluating the coolability of relocated metal fuels during a postulated accident in a SFR, they focused on late phase behavior in which the core material relocates downward through the core support plate into the inlet plenum where the structures are more open and thus consistent with the open pool configuration. There is still a knowledge gap related to nature of metal fuel fragmentation and relocation within the fuel assembly structures. Argonne National Laboratory (ANL) is planning to conduct experiments regarding metal fuel relocation in the core structures which mock up the PGSFR's fuel assembly design. In the present study, preliminary tests for demonstration of melting and injecting the metal fuel were conducted using copper. Metal fuel relocation experiments with single fuel pin test section are planned to be conducted for understanding the flow and freezing behavior of the molten metal fuel in a narrow sodium channel and for evaluating the coolability of the relocated fuel. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of an unexpected reflector temperature effect for water-isolated array configurations - 14500

It has been conventional wisdom in the criticality safety discipline that for spent fuel systems like water pit storage and transportation, modeling water at its peak density will maximize reactivity. Thus, modeling water at 3.96 deg. C will produce a conservatively bounding k{sub eff} for that configuration. This assumption has been found to be incorrect for certain high-leakage water-isolated array configurations. In fact, temperatures up to the boiling point of water can in fact be more reactive, and the most reactive temperature is highly dependent upon the specific fuel configuration being analyzed. In light of the accident at Fukushima-Daiichi - where the spent fuel pool temperature increased - knowledge of this unexpected behavior is essential to ensuring that criticality safety evaluations are conservatively bounding. To illustrate the reflector temperature effect, MC21 calculations are provided for a sensitivity study based on LEU-COMP-THERM-044, which models the IPEN/MB-01 reactor at various temperatures between 3.9 deg. C and 93.3 deg. C. (authors)

42 ENGINEERING↗

Effect of Control Blade History, and Axial Coolant Density and Burnup Profiles on BWR Burnup Credit

Oak Ridge National Laboratory (ORNL) and the US Nuclear Regulatory Commission (NRC) have initiated a multiyear project to investigate the application of burnup credit (BUC) for boiling water reactor (BWR) fuel in storage and transportation systems (often referred to as casks) and spent fuel pools (SFPs). This work is divided into two main phases. The first phase investigated the applicability of peak reactivity methods currently used in SFPs to transportation and storage casks and the validation of reactivity calculations and spent fuel compositions within these methods. The second phase focuses on extending BUC beyond peak reactivity. This paper documents the analysis of the effects of control blade insertion history, and moderator density and burnup axial profiles for extended BWR BUC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a pool boiler heat transport system for a 25 kWe advanced Stirling conversion system

The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding a heat transport system to more uniformly supply heat to the heater head tubes. One heat transport system with favorable characteristics is an alkali metal pool boiler. An alkali metal pool boiler heat transport system was designed for a 25-kW advanced Stirling conversion system (ASCS). Solar energy concentrated on the absorber dome boils a eutectic mixture of sodium and potassium. The alkali metal vapors condense on the heater head tubes, supplying the Stirling engine with a uniform heat flux at a constant temperature. Boiling stability is achieved with the use of an enhanced boiling surface and noncondensible gas.

Anderson, W. G.↗

Conversion of Nuclear Waste into Nuclear Waste Glass: Experimental Investigation and Mathematical Modeling

The melter feed, slurry, or calcine charged on the top of a pool of molten glass forms a floating layer of reacting material called the cold cap. Between the cold-cap top, which is covered with boiling slurry, and its bottom, where bubbles separate it from molten glass, the temperature changes by up to 1000 K. The processes that occur over this temperature interval within the cold cap include liberation of gases, conduction and consumption of heat, dissolution of quartz particles, formation and dissolution of intermediate crystalline phases, and generation of foam and gas cavities. These processes have been investigated using thermal analyses, optical and electronic microscopies, x-ray diffraction, as well as other techniques. Properties of the reacting feed, such as heat conductivity and density, were measured as functions of temperature. Investigating the structure of quenched cold caps produced in a laboratory-scale melter complemented the crucible studies. The cold cap consists of two main layers. The top layer contains solid particles dissolving in the glass-forming melt and open pores through which gases are escaping. The bottom layer contains bubbly melt or foam where bubbles coalesce into larger cavities that move sideways and release the gas to the atmosphere. The feed-to-glass conversion became sufficiently understood for representing the cold-cap processes via mathematical models. These models, which comprise heat transfer, mass transfer, and reaction kinetics models, have been developed with the final goal to relate feed parameters to the rate of glass melting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initiation of Flash Boiling of Multicomponent Miscible Mixtures with Application to Transportation Fuels and Their Surrogates

This paper presents methodologies to predict thermodynamic conditions that initiate flash boiling by spontaneous nucleation of liquids consisting of hundreds of miscible liquids and their lower order surrogate mixtures. The methods are illustrated with a kerosene-based fuel and a seven-component surrogate for it. The predictions are compared to measurements of nucleation temperatures obtained from a pulse-heating technique that rapidly heats a microscale platinum film immersed in a pool of the test fluid. Nucleation temperatures are predicted using a generalized corresponding states principle (GCSP), and a modification of classical nucleation theory that considers the mixture as a pseudo single component fluid (PSCF). The intent is to offer a simple means to predict the initiation of flash boiling that can have important consequences for fuel efficiency in combustion engines. We show that contact angle has a strong effect such that predicted and measured spontaneous nucleation temperatures agree for a given heating rate only if contact angle is accounted for in the theory. For low heating rates (less than 2 × 10 7 K/s), predicted nucleation temperatures, assuming a spherical bubble, are 13% higher than measurements. The gap is closed to about 6% as the heating rate reaches 3 × 10 8 K/s (the highest that could be reached in the experiments) and to less than 1% when the measured nucleation temperature is extrapolated to an asymptotic (zero contact angle) limit. Here, the PSCF method (using mixture properties as mole fraction averages of mixture component properties evaluated at the same reduced temperatures as the mixtures) and the GSCP predict virtually identical nucleation temperatures, while the GCSP method does not require any mixture property values.

42 ENGINEERING↗

Multi-Physics Coupled Seismic Safety Analysis of Molten-Salt Reactors

Pool-type Molten Salt Reactors (MSRs) are a promising advanced nuclear reactor concept relying on passive physical behavior to provide increased safety characteristics. The high heat capacity, high boiling point, unpressurized liquid salt contains the nuclear fuel and as it passes through the vessel achieves criticality and produces nuclear power. The salt then carries away the heat produced along with the delayed neutron precursors towards heat exchangers and primary pumps before entering the core. This forms a highly coupled multiphysics problem between neutronics and fluid flow, which makes modeling these reactors challenging. The safety/licensing case heavily relies on modeling and simulation to prove their safety, and significant effort has been expanded by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to develop the appropriate simulation tools. Their safety/licensing will require a thorough analysis of their behavior during earthquake-based transients. Earthquakes are a transient condition commonly experienced in many regions, and are safely survived by dozens of reactors every year. Nonetheless, significant conservatisms were introduced with limited predictive modeling and simulation available. The first-of-a-kind capability developed by this research will allow for engineers to analyze ranges of design-basis and beyond-design basis accident scenarios to assess the integrity of the reactor vessel and surrounding system, possibly allowing for limiting the costly conservatisms in the design. This projects uses MASTODON, Griffin, and Pronghorn in the NEAMS ecosystem to model the coupled multiphysics problem posed by an earthquake in a molten salt reactor. It marches through a number of number of coupling schemes, from uncoupled simulations to tightly two-way coupled simulations. The appropriate level of coupling for these simulations will then be determined based on the accuracy in the quantities of interest (QoI) and computational effort involved in each scheme. The QoIs chosen for this paper include the mass flow rate across the heat exchanger (for Pronghorn simulations), power output of the reactor (for Griffin simulations), and the maximum Von Mises stress (for MASTODON simulations). This summary paper reports on the current progress of this project, with 2D tightly coupled multiphysics results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗