Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Target Acquisition and Positioning Study (TAPS)

The Scientific Instruments for the Large Space Telescope (LST) require a high degree of accuracy for positioning targets within their respective entrance apertures. The acquisition, verification of position, and guidance during an experiment must be accomplished with a minimum loss of observing time for the maximum effectiveness of the total mission. This study evaluates several viable concepts and modes of operation that are applicable for a Target Acquisition and Positioning System (TAPS) that is responsive to the LST instrument requirements.

Source record↗

Acoustic field positioning for containerless processing

The non-contact positioning of materials in a space processing chamber is accomplished using a new type of acoustic levitator. Liquid and solid materials are positioned using a single source of sound. Fine control of position may be obtained by motion of an acoustical reflector. Electrical power required is usually less than 100 watts. The system operates satisfactorily at high and low temperatures and is adaptable as an add-on feature to existing space experiments. Containerless melting and solidification can be performed and a freely suspended liquid can be shaped to the contour of the sound field. Experiments are described in which aluminum, glass and plastic materials are melted and solidified in the containerless state. The system has applications to containerless crystal growth, melting and related processes.

Whymark, R. R.↗

Acoustic chamber for weightless positioning

The objective of this work is to perfect and extend the acoustic position technique that was developed at JPL for use in the future Space Processing Laboratory in Space. The main effort is centered on design of a position device for processing of molten materials. Namely, a resonator has the capability of positioning in an extreme temperature gradient and a frequency servo loop to maintain it there as the temperature varies.

Wang, T. G.↗

Intrathoracic and venous pressure relationships during responses to changes in body position

Simultaneous end-expiratory pressures, referred to midthoracic level, in the superior and abdominal venae cavae, pericardial space, and right and left heart, were recorded without thoracotomy in three anesthetized dogs during sudden changes from supine to vertical head-up or head-down body positions. Intrathoracic and dependent great vein pressures referred to midchest level (sixth thoracic vertebra) decreased and showed simple hydrostatic gradients in either vertical position. However, a discontinuity in the large vein hydrostatic gradient occurred just distal to the superior margin of the thorax in either body position and was resumed again above this level. It is concluded that, just as the cerebrospinal fluid and intraperitoneal pressures minimize the effects of gravitational and inertial forces on the cerebral and visceral circulations, the pericardial and pleural pressures have a similar role for the heart proper.

Avasthey, P.↗

Continuous-output terminal-shock-position sensor for mixed-compression inlets evaluated in wind tunnel tests of YF-12 aircraft inlet

An electronic sensor was built to measure the position of the terminal shock in a supersonic inlet. The sensor uses several static-pressure taps in the inlet wall. The sensor output is continuously proportional to shock position. When the sensor was installed in a YF-12 aircraft flight inlet during wind tunnel tests, it indicated shock position within + or - 5 percent of the total distance covered by the static-pressure-tap region. The maximum error caused by an angle of attack change of 4 deg was less than 25 percent. In the region of normal inlet operation, the angle of attack error is negligible. Frequency-response tests show the amplitude ratio is constant out to 60 Hz, and decreases to about 50 percent at 100 Hz, with a phase lag of 50 deg.

Dustin, M. O.↗

Position error propagation in the simplex strapdown navigation system

The results of an analysis of the effects of deterministic error sources on position error in the simplex strapdown navigation system were documented. Improving the long term accuracy of the system was addressed in two phases: understanding and controlling the error within the system, and defining methods of damping the net system error through the use of an external reference velocity or position. Review of the flight and ground data revealed error containing the Schuler frequency as well as non-repeatable trends. The only unbounded terms are those involving gyro bias and azimuth error coupled with velocity. All forms of Schuler-periodic position error were found to be sufficiently large to require update or damping capability unless the source coefficients can be limited to values less than those used in this analysis for misalignment and gyro and accelerometer bias. The first-order effects of the deterministic error sources were determined with a simple error propagator which provided plots of error time functions in response to various source error values.

Source record↗

A transformation method for deriving from a photograph, position and heading of a vehicle in a plane

Equations have been derived that transform perspectively viewed planar surface coordinates, as seen in a photograph, into coordinates of the original plane surface. These transformation equations are developed in terms of nine geometric variables that define the photographic setup and are redefined in terms of eight parameters. The parameters are then treated as independent quantities that fully characterize the transformation and are expressed directly in terms of the four corner coordinates of a reference rectangle in the object plane and their coordinates as seen in a photograph. Vehicle position is determined by transforming the perspectively viewed coordinate position of a representative vehicle target into runway coordinates. Vehicle heading is determined from the runway coordinates of two vehicle target points. When the targets are elevated above the plane of the reference grid, the computation of the heading angle is unaffected; however, the computation of the target position may require adjustment of two parameters. Methods are given for adjusting the parameters for elevation and an example is included for both nonelevated and elevated target conditions.

Sleeper, R. K.↗

Acoustic field positioning for containerless processing

The noncontact positioning of materials in a space processing chamber is accomplished using a new type of acoustic levitator. Liquid and solid materials are positioned using a single source of sound. Fine control of position may be obtained by motion of an acoustical reflector. The electrical power required is usually less than 100 watts. The system operates satisfactorily at high and low temperatures and is adaptable as an 'add-on' feature to existing space experiments. Containerless melting and solidification can be performed and a freely suspended liquid can be shaped to the contour of the sound field. Experiments are described in which aluminum, glass and plastic materials are melted and solidified in the containerless state. The system has applications to containerless crystal growth, melting and related processes.

Whymark, R. R.↗

Comparison of susceptibility to motion sickness during rotation at 30 rpm in the earth-horizontal, 10 deg head-up, and 10 deg head-down positions

Normal persons rotated about an earth-horizontal axis vary in their susceptibility to motion sickness. An experimental study was conducted to measure intraindividual differences in susceptibility in 12 subjects when rotated 10 deg head up and 10 deg head down as well as in the horizontal position. Subjects assumed the test-position 60 min prior to rotation, thus providing an opportunity for translocation of body fluids. Physiological and psychological measurements were conducted throughout the experiment. There were no intraindividual differences in susceptibility to motion sickness in the three positions tested, although there were significant differences in vital capacity, demonstrating the expected fluid shifts. It was concluded that, in the sample of subjects tested, short-term effects of fluid shifts greater than those that would be manifested in zero gravity had no definite effect on motion sickness susceptibility.

Graybiel, A.↗

Experiments for improved positioning by means of integrated Doppler satellite observations and the NNSS broadcast ephemeris

An effort to improve station position recovery using broadcast ephemeris in Doppler data reduction was studied. A comparison of precise and broadcast ephemerides, treating the former as the standard, yielded information about the state disturbance that can be associated with the broadcast ephemeris. Statistical information about the state disturbance was used with current observational data for improved position recovery. The rank deficiency problem encountered in the short arc geodetic adjustment procedure was analysed and it was deduced that the fundamental rank deficiency is six, scale information being derivable from the wavelength of transmission. Coordinate differences between stations coobserving a pass are estimable. The uncertainty of the broadcast ephemeris, now in the WGS72 system, was assessed. It was conservatively estimated that its positional uncertainty may vary between 19 to 26 m in-track, 15 to 20 m cross-track and 9 to 10 m in radial directions depending on the incidence of the epoch of observations in the interinjection period.

Arur, M. G.↗

On Nth roots of positive operators

A bounded operator A on a Hilbert space H was positive. These operators were symmetric, and as such constitute a natural generalization of nonnegative real diagonal matrices. The following result is thus both well known and not surprising: A positive operator has a unique positive square root (under operator composition).

Brown, D. R.↗

Station position results using concentrated C-band tracking of GEOS-3

Station positions for the GEOS 3 C Band tracking network were estimated using C Band and laser data taken during a two-week concentrated tracking period. The C Band stations are located primarily in the continental United States and on Western Atlantic islands. The network, however, included stations in Hawaii, in West Germany, and on Kwajalein atoll. Estimated accuracies for the recovered positions are 2 m for the continental U. S. and Atlantic sites, 5 m for Hawaii, and 10 m for Kwajalein. The dominant contributor to these uncertainties is geopotential model error. Thus, the C Band/laser data set could be used for more accurate center-of-mass positioning of a continental network of stations.

Krabill, W. B.↗

Positions of galactic X-ray sources - l/II/ between 320 and 340 deg

The precise (20-40 sec) positions of seven X-ray sources in the celestial region corresponding to the galactic longitude range from 320 to 340 deg are reported. The sources include a recurrent transient X-ray source (MX1608-52) and a source 2S1553-542 coincident with a gamma-ray source within the given errors of position. The positions reported reduce the previously reported areas of the error region for six of the sources by factors ranging from 10 to 100. The presented results add confidence to the proposed radio candidates for 4U1624-49 and 4U1642-45 considered by Sanduleak and Dolan (1974) and Seaquist (1977).

Apparao, K. M. V.↗

The spectrum and position of solar noise storms at decameter wavelengths

Decametric storm radiation during the period July-August 1970 has been observed simultaneously with a high sensitivity spectrograph at Arecibo Observatory and with the log-periodic, swept-frequency array of the Clark Lake Radio Observatory. The observations complement each other; different types of fine structure emissions can be easily identified on the spectrograph records and their position can be determined from the swept-frequency recordings. The relative positions of the different emissions which have been observed during the storms are studied. Four distinct sources appear to be present. The continuum emission, the type I bursts and the flare-related type III's are all emitted at different locations. The storm type III bursts, type IIIb's and drift pairs overlap in position, but appear at different locations than the previously mentioned sources.

De La Noe, J.↗

Measurements of X-ray source positions by the scanning modulation collimator on HEAO 1

This paper reports preliminary results on the positions of X-ray sources obtained with the modulation collimator on the first NASA High Energy Astronomy Observatory, HEAO 1. Calibration on Sco X-1 establishes the experiment capabilities to be within 7 sec as limited by aspect errors. For the reported X-ray sources certain ambiguities in their positions are resolved and the previous optical identifications of four sources are confirmed, two of which are X-ray bursters and one of which is the black hole candidate Cir X-1. An accurate position for a new transient source is also presented.

Gursky, H.↗

The characteristics of a lift cruise fan V/STOL configuration in near proximity to a small deck with finite edge positions

Two V/STOL model configurations utilizing lift-cruise-fans for the propulsion system have been tested in the presence of a small landing platform with finite deck edge positions. Results and analysis of these tests are presented. The model was tested at both static (zero velocity) and forward speed conditions with several heights and deck edge positions. Configurations utilizing three fans and four fans were investigated. Incremental forces and moments induced by the various deck edge positions are analyzed as relating to the model height above the ground and the thrust velocity relationships. The test and analysis show the induced forces to be relatively unaffected by deck edge.

Stewart, V. R.↗

Blood filling and flow in lungs during change in body position in space

In the horizontal position (supine and lateral), in the upright position (head up and head down) and during change of the cat body position in space, quantitative responses of regional blood volume and blood flow in the lungs (ml/100 cu cm) revealed presence of the gradient in the gravitation direction. Blood volume and blood flow of different lung portions changed qualitatively and quantitatively in different ways. These changes occurred only in the direction producing the equality of regional hydrostatical and hemodynamic loads in the lungs at either horizontal level.

Pogodin, A. S.↗

Experiments for improved positioning by means of integrated Doppler satellite observations and the NNSS broadcast ephemeris

A study to improve position determination using broadcast ephemeris in Doppler data reduction is presented. The uncertainty of the broadcast ephemeris was assessed, and sample autocovariances were computed for acceleration, velocity, and position considering the state disturbance as a signal. An experiment was made in which three stations coobserved 12 passes, and the removal of the radial bias resulted in a chord distance which was in better agreement with the ground survey. In the second experiment, the station positions of the first test simulated the range observations, and the autocovariance function of the acceleration signal in the Cartesian coordinate system was used in an adaptive filtering procedure to improve the state of the satellite in one pass.

Arur, M. G.↗