Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$%, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Zeolite‐Based Catalysts for Conversion of Oxygenated Polymer Waste by Positron Annihilation

Positron Annihilation Lifetime Spectroscopy (PALS) has been employed to investigate the catalysts HZSM-5 and MESO−Y, which play a pivotal role in catalyzing and upgrading plastics, with a primary focus on oxygenated polymers, thereby transforming existing plastic materials into simpler, higher-quality value-added products. Here, in this study, PALS was systematically compared with other complementary analytical techniques. The research outcomes have successfully demonstrated the efficacy of PALS in elucidating the morphology and topology of zeolites at micro/meso-meter scales. The first experiment focuses on H-ZSM-5 zeolite subjected to treatments involving polyurethane and polypropylene. The second experiment delves into H-ZSM-5 zeolites with varying Si/Al ratios, both before and after conversion. The third experiment investigates Y zeolites that are surfactant templated to induce meso-porosity, examining their fresh state as well as their post-conversion condition. The PALS analysis was supplemented by BET (Brunauer-Emmett-Teller) analysis and NMR (Nuclear Magnetic Resonance) spectroscopies. Notably, PALS exhibits superior sensitivity, at the sub-nanometer scale, suggesting its potential as a preferred complementary method for catalysis studies. In conclusion, the integration of PALS into the repertoire of analytical tools enhances our understanding of catalyst behavior and catalytic processes, offering valuable insights for the advancement of plastic recycling and catalysis research.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Evaluation of adsorption and mechanical strength of 13X zeolite mixtures with phyllosilicate binders using molecular dynamics simulation and positron annihilation spectroscopy

There is growing interest in developing zeolites with novel internal structures that have optimal adsorptive capacity and high mechanical strength, while offering advantages, such as being light weight. We integrate computational and experimental methods to explore the effect of binder/zeolite types, and weight percentages on the mechanical strength of 13X zeolite and adsorption capacities of N 2 , H 2 O, and CO 2 for additive manufacturing (AM) applications with the goal of maximizing both adsorption and strength. Zeolite 13X mixtures and phyllosilicate binders (either bentonite or kaolin) are combined using molecular dynamics (MD) simulations to create structures with various binder/zeolite weight percentages. Further, adsorption capabilities and mechanical strength are assessed using the grand canonical Monte Carlo (GCMC) and ReaxFF modules, respectively. Our modeling shows that an optimized zeolite/binder ratio for N 2 adsorption is around 15 wt% for kaolin and roughly 10 wt% for bentonite. The resulting parameters can be applied to facilitate macro-scale computational fluid dynamics (CFD) and finite element method (FEM) simulations of an AM zeolite structure. We also performed Positron Annihilation Lifetime Spectroscopy (PALS) measurements on zeolite samples to explore the effect of changes in the internal volume. The results show an inverse relationship between the free volume and the solid loading and adding a binder changes the morphology of the zeolite-binder compound and decreases open-volume area significantly.

36 MATERIALS SCIENCE↗

Primary Mediastinal B Cell Lymphoma in the Positron-Emission Tomography Era Executive Summary of the American Radium Society Appropriate Use Criteria

Primary mediastinal B cell lymphoma (PMBCL) is a highly curable subtype of non-Hodgkin lymphoma that is diagnosed predominantly in adolescents and young adults. Consequently, long-term treatment-related morbidity is critical to consider when devising treatment strategies that include different chemoimmunotherapy strategies with or without radiation therapy. Furthermore, adaptive approaches using the end-of-chemotherapy (EOC) positron emission tomography (PET)/computed tomography (CT) scanning may help to determine which patients may benefit from additional therapies. We aimed to develop evidence-based guidelines for treating these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Perspectives on relativistic electron–positron pair plasma experiments of astrophysical relevance using high-power lasers

The study of relativistic electron–positron pair plasmas is both of fundamental physics interest and important to understand the processes that shape the magnetic field dynamics, particle acceleration, and radiation emission in high-energy astrophysical environments. Although it is highly desirable to study relativistic pair plasmas in the laboratory, their generation and control constitutes a critical challenge. Significant experimental and theoretical progress has been made over recent years to explore the use of intense lasers to produce dense relativistic pair plasma in the laboratory and study the basic collective plasma processes associated with these systems. Important challenges remain in terms of improving the number of pairs, system size, and control over the charge neutrality required to establish laboratory platforms that can expand our understanding of relativistic pair plasma and help validate underlying models in conditions relevant to high-energy astrophysical phenomena. Furthermore, we highlight recent progress in this field, discuss the main challenges, and the exciting prospects for studying relativistic pair plasmas and astrophysics relevant instabilities in the laboratory in the near future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗