Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Combiner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Giant Planet Atmospheres: Dynamics and Variability from UV to Near-IR Hubble and Adaptive Optics Imaging

Abstract: Each of the giant planets, Jupiter, Saturn, Uranus, and Neptune, has been observed by at least one robotic spacecraft mission. However, these missions are infrequent; Uranus and Neptune have only had a single flyby by Voyager 2. The Hubble Space Telescope, particularly the Wide Field Camera 3 (WFC3) and Advanced Camera for Surveys (ACS) instruments, and large ground-based telescopes with adaptive optics systems have enabled high spatial resolution imaging at a higher cadence, and over a longer time, than can be achieved with targeted missions to these worlds. These facilities offer a powerful combination of high spatial resolution, often <0.05”, and broad wavelength coverage, from the ultraviolet through the near infrared, resulting in compelling studies of the clouds, winds, and atmospheric vertical structure. This coverage allows comparisons of atmospheric properties between the planets, as well as in different regions across each planet. Temporal variations in winds, cloud structure, and color over time scales of days to years, have been measured for all four planets. With several decades of data already obtained, we can now begin to investigate seasonal influences on dynamics and aerosol properties, despite orbital periods ranging from 12 to 165 years. Future facilities will enable even greater spatial resolution and, combined with our existing long record of data, will continue to advance our understanding of atmospheric evolution on the giant planets.

Amy A Simon↗

Development of a Deployable Opitcal Aperature

The Deployable Optical Receive Aperture (DORA),a new technology being developed jointly between JetPropulsion Laboratory (JPL) and Arizona State University(ASU), is based on deploying arrays of fast optical detectors tocreate large receive apertures and seeks to achieve gigabitconnectivity at distances of thousands of kilometers. Smallspacecraft forming the LunaNet communications network andequipped with optical communications systems, such as theproposed DORA aperture, should be able to communicate atGigabit per second rates over long distances. This data rateenhancement can allow gigabit per second connectivitybetween lunar assets (astronauts, rovers, instruments) and thelunar gateway. Under sponsorship of NASA's Small SpacecraftTechnology Program (SSTP), JPL is deploying the DORApayload and ASU is developing a 3U CubeSat for a follow-onlow-Earth-orbit (LEO) mission to demonstrate DORA'scapabilities. The basic DORA payload consists of 5 receiverpanels, a transmitting telescope and processing units. Eachreceiver panel contains dozens of power-combined detectors tomimic a large optical aperture. The total receive aperture ofDORA is provided by the sum of the effective detecting area ofthe 5 panels. The transmit telescope includes a 200mW, 850nmlaser and a voice-coil fast steering mirror (FSM). The resultingDORA terminal should be able to provide duplex connectivityat rates up to 1 gigabit per second at the distances of interest.We have designed the entire DORA payload and plan topresent the test results of our DORA engineering model. Theseresults include angle-of-arrival, data rate and bit error ratemeasurements.

Yi, Lin↗

Extraterrestrial Molecular Indicators of Life Investigation (EMILI)

Future missions to Enceladus, Europa, Mars, and beyond may seek the molecular signs of extraterrestrial life through chemical analysis of acquired samples. Particularly on ocean worlds such as Enceladus and Europa, samples may contain trace ocean-borne molecular biosignatures of extant life that may or may not share similarities to those of terrestrial life. In situ analyses must be prepared to detect and characterize a wide range of possible molecular species, structures, and patterns, typically with exquisite sensitivity and within a complex, poorly-characterized planetary environment. The Extraterrestrial Molecular Indicators of Life Investigation (EMILI) is designed to meet or exceed the requirements of such missions for organic molecular analysis through a powerful combination of dual chemical separation and both optical and mass spectrometry detection techniques, realized in an integrated, compact instrument package fully compatible with anticipated flight resources and conditions. The full EMILI instrument combines two sample analysis subsystems to provide wide-ranging and complementary detection of organic compounds and inorganic salts. The Gas Analysis Processing System (GAPS) uses a chemical derivatization protocol with gas chromatography (GC) separation prior to detection in an ion trap mass spectrometer (ITMS) to enable full characterization of lower-polarity, volatile and semi-volatile molecules such as fatty acids and hydrocarbons. The Organic Capillary Electrophoresis ANalysis System (OCEANS) uses a liquid-based extraction protocol with CE separation to enable precise analysis of more water-soluble/polar compounds. OCEANS features a laser-induced fluorescence detection mode to perform ultra-sensitive quantitative analysis of chiral amino acids. In EMILI, OCEANS is additionally coupled to the same ITMS through a novel electrospray ionization interface. The common ITMS allows EMILI to identify and cross-correlate molecular species and patterns, detected through either or both protocols, of molecular weights to over 1000 u, potentially even revealing complex biosignatures such as alien oligopeptides and informational polymers.

Europa↗

How to Design and Implement an Equitable Building Performance Standard: Lessons from the Building Performance Standards Technical Assistance Network

States and local governments seek to accomplish the intersecting goals of reducing greenhouse gas emissions, improving building operations, and bettering the daily lives of their communities. Building Performance Standards (BPS) have emerged as a critical policy lever to reach these intertwined climate and societal goals. These policies, if shaped and implemented well, have the chance to not only help reach our nation's climate, energy, and livability goals, but to do so with the active participation of those traditionally excluded from policy processes. This nascent policy movement provides jurisdictions across the country the opportunity to shape these policies from the outset to deliver comfort, health, and safety in our built environment for all. The US Department of Energy in partnership with our National Laboratories have been providing technical assistance for jurisdictions interested in, adopting, and implementing Building Performance Standards. Through this work, the BPS Technical Assistance Network (TA Network) has tracked and documented the innovative and equitable approaches to BPS across the country. The TA Network has crafted foundational technical analysis, such as building stock and emissions impacts, equity prioritization and peak load impacts, and aggregated cost benefit analysis. And by combining powerful technical analysis with dissemination of best practices resources to support equitable implementation, the TA Network provides jurisdictions with the tools and support necessary to embark on their ambitious policy goals.

building performance standards↗

Nuclear Thermal Energy Storage Configurations for Industrial Combined Heat and Power Supply: Conceptual Study and Engineering Designs

The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Minnesota’s Combined Heat and Power (CHP) Action Plan

With funding from the Office of Energy Efficiency and Renewable Energy State Energy Program’s Competitive Financial Assistance program, the Minnesota’s Department of Commerce (COM) created a Combined Heat and Power (CHP) Action Plan that has the potential to double the state’s CHP capacity, help the state achieve its target of 1.5% annual energy savings, and improve the resilience of the distribution grid.

implementation model, combined heat and power acti↗

State-by-State comparison of combined heat and power to photovoltaic installations at manufacturing facilities with heat and power loads

Manufacturing facilities with large electricity and steam loads commonly meet those loads with a grid and boiler (GB) system configuration. In this study, two alternatives, a natural gas turbine cycle driven combined heat and power (CHP) system configuration and a grid boiler system augmented with photovoltaics (GB-PV), are investigated sustainable manufacturing in reference to the GB system configuration. For this purpose, their discounted payback period (DPP), carbon dioxide (CO 2 ) and nitrogen oxides (NO x ) emission reductions, and primary fossil energy impacts are calculated. The major contribution of this study is that it directly compares the application of both CHP and PV technologies at an assumed manufacturing facility in all 50 states of the United States. This highlights the location-specific impacts of the facility. The examined manufacturing facility utility requirements are 5 MW of power and over 12,000 kg/h of 250 kPa and 400 K saturated steam. A DPP of less than 25 years, the technology lifetime, is found in 44 states for the CHP system configuration and 6 states for the GB-PV system configuration. GB-PV and CHP cost-effectively reduce CO 2 in 44 and 38 states, respectively. CHP is better for NO x reduction, whereas GB-PV is better for primary fossil energy reduction.

14 SOLAR ENERGY↗

Incorporating Combined Heat and Power Modeling into the REopt Lite Web Tool

The National Renewable Energy Laboratory (NREL) is working with project partners to extend the U.S. Department of Energy’s (DOE’s) REopt Lite tool to include combined heat and power (CHP) modeling capabilities. REopt Lite currently provides technoeconomic optimization and resilience analysis for grid-connected solar photovoltaics, (PV), wind, and battery storage at a site. The tool analyzes hourly data across the project lifecycle and evaluates the trade-off between capital costs, operating costs, and savings to find the most cost-effective mix of technologies.

Combined Heat and Power, CHP, Modeling, Tool, Fact↗

Integrated Renewable Combined Heat and Power for Ethanol

Conference presentation at 48th International Technical Conference on Clean Energy (Clearwater Clean Energy Conference), Clearwater, Florida, June 16–19, 2024. This project evaluates the technical and economic feasibility of small‑scale combined heat and power (CHP) systems using corn stover to support bioenergy with carbon capture and storage (BECCS) at ethanol facilities. The work includes resource characterization, pilot‑scale gasification and CO 2 capture testing to support techno‑economic analysis, economic evaluation of CHP deployment and potential carbon revenue, and life‑cycle assessment of gasification‑based CHP systems.

09 BIOMASS FUELS↗

Transmitter switch for high-power microwave output

Combiner system can be used for combining output powers of two transmitters or for switching from one to the other. This can be done when pair of transmitters operate on same frequency and carriers are phase coherent as by excitation from single exciter.

Wiggins, C. P.↗

Optimization of the oxidant supply system for combined cycle MHD power plants

An in-depth study was conducted to determine what, if any, improvements could be made on the oxidant supply system for combined cycle MHD power plants which could be reflected in higher thermal efficiency and a reduction in the cost of electricity, COE. A systematic analysis of air separation process varitions which showed that the specific energy consumption could be minimized when the product stream oxygen concentration is about 70 mole percent was conducted. The use of advanced air compressors, having variable speed and guide vane position control, results in additional power savings. The study also led to the conceptual design of a new air separation process, sized for a 500 MW sub e MHD plant, referred to a internal compression is discussed. In addition to its lower overall energy consumption, potential capital cost savings were identified for air separation plants using this process when constructed in a single large air separation train rather than multiple parallel trains, typical of conventional practice.

Juhasz, A. J.↗

Natural Gas Combined Cycle (NGCC) Power Plants with Carbon Capture and Exhaust Gas Recycle (EGR)

The purpose of this study is to determine the cost and performance of natural gas combined cycle (NGCC) power plants using state-of-the-art gas turbines with post combustion carbon capture and recycle streams designed to increase the CO 2 concentration in the inlet to the capture system. Increasing the inlet CO 2 concentration by exhaust gas recycle (EGR) is expected to improve the efficiency of the capture system and reduce its costs. Primary results indicate that adding EGR to NGCC plants with CO 2 capture results in minimal improvement to the cost of electricity. The addition of 50 percent EGR in NGCC plants with CO 2 capture reduces the LCOE by 2 percent over the LCOE of the same design without EGR as reference. Including the EGR ductwork and cooler in a greenfield plant design could still be prudent since there is some cost advantage to EGR and it would allow more flexibility for taking advantage of future improvements in the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Model Guidance to Address Barriers to Combined Heat and Power and Waste Heat to Power

Congress directed that the US Department of Energy (DOE) initiate a review of interconnection rules to identify barriers to interconnection and ways to better integrate combined heat and power (CHP) and waste heat to power (WHP) in the electric grid. Oak Ridge National Laboratory (ORNL) supports DOE by providing technical assistance for CHP. DOE tasked ORNL with the interconnection review and development of model guidance to enable developers and CHP owners to interconnect more CHP. This report summarizes the work that DOE initiated in response to the congressional request.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Combined Heat and Power Systems in REopt

This webinar will explore how the National Laboratory of the Rockies' REopt(R) web tool can evaluate the techno-economics of combined heat and power (CHP) technologies and systems to assess performance and financial viability. REopt can analyze both standalone CHP systems, and systems paired with other on-site energy resources. Participants will gain practical insights into using REopt to optimize site energy strategies, reduce energy costs, and improve site energy security and outage recovery.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible Natural Gas/Hydrogen Combined Heat and Power System

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

CHP, ID/3D↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗