Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High Performance Nickel Electrodes for Space Power Applications

Performance characteristics such as efficiency, specific energy density and power density of nickel electrodes are generally limited by the electrode microstructure and nature of the active material within the electrode matrix. Progress is being made in our laboratory in a collaborative effort with NASA-Lewis Research Center to develop lighter weight, mechanically stable and highly efficient nickel electrodes for aerospace applications. Our approach is based on an electrode microstructure fabricated from a mixture of nickel fibers as small as 2 microns diameter and cellulose fibers. Performance data in flooded cell tests and cycle life data are presented. Performance characteristics are compared to other electrode microstructures such as the Fibrex Fiber mat and the Fibrex Powder substrate. The flexibility of our electrode microstructure and the significant advantages it offers in terms of weight and performance are demonstrated, in particular, its ability to accept charge at high rates and to discharge at high rates.

Adanuvor, Prosper K.↗

Wind Turbine Generator System Duration Test Report for the ARE 442 Wind Turbine

This test is being conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, four turbines are being tested at the NWTC as a part of this project. Duration testing is one of up to 5 tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality tests. The results of the testing provide manufacturers with reports that may be used for small wind turbine certification. The test equipment includes a grid connected ARE 442 wind turbine mounted on a 30.5 meter (100 ft) lattice tower manufactured by Abundant Renewable Energy. The system was installed by the NWTC Site Operations group with guidance and assistance from Abundant Renewable Energy.

17 WIND ENERGY↗

Wind Turbine Generator System Duration Test Report for the Gaia-Wind 11 kW Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, five turbines are being tested at the National Renewable Energy Laboratory's (NRELs) National Wind Technology Center (NWTC) as a part of thisproject. Duration testing is one of up to five tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality tests. The results of the testing will provide the manufacturers with reports that may be used for small wind turbine certification. The test equipment includes a Gaia-Wind 11 kW wind turbine mounted on an 18 m monopole tower.Gaia-Wind Ltd. manufactured the turbine in Denmark, although the company is based in Scotland. The system was installed by the NWTC Site Operations group with guidance and assistance from Gaia-Wind.

17 WIND ENERGY↗

Cross-Layer Self-Adaptive/Self-Aware System Software for Exascale Systems

The extreme level of parallelism coupled with the limited available power budget expected in the exascale era brings unprecedented challenges that demand optimization of performance, power and resiliency in unison. Scalability on such systems is of paramount importance, while power and reliability issues may change the execution environment in which a parallel application runs. To solve these challenges exascale systems will require an introspective system software that combines system and application observations across all system stack layers with online feedback and adaptation mechanisms. In this paper we propose the design of a novel self-aware, self-adaptive system software in which a kernel-level Monitor, which continuously inspects the evolution of the target system through observation of Sensors, is combined with a user-level Controller, which reacts to changes in the execution environment, explores opportunities to increase performance, save power and adapts applications to new execution scenarios. We show that the monitoring system accurately monitors the evolution of parallel applications with a runtime overhead below 1-2%. As a test case, we design and implement a user-runtime system that aims at optimizing application’s performance and system power consumption on complex hierarchical architectures. Our results show that our adaptive system reaches 98% of performance efficiency of manually-tuned applications.

High Performance computing, Self-aware/self-adapti↗

Duration Test Report for the Ventera VT10 Wind Turbine

This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small wind turbines. Five turbines were tested at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of round one of this project. Duration testing is one of up to five tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality. Test results will provide manufacturers with reports that can be used to fulfill part of the requirements for small wind turbine certification. The test equipment included a grid-connected Ventera Energy Corporation VT10 wind turbine mounted on an 18.3-m (60-ft) self-supporting lattice tower manufactured by Rohn.

17 WIND ENERGY↗

Wind Turbine Generator System Acoustic Noise Test Report for the ARE 442 Wind Turbine

This test was conducted on the ARE 442 as part of the U.S. Department of Energy's (DOE's) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, five turbines are being tested at the National Wind Technology Center (NWTC) as a part of this project. Acoustic noise testingis one of up to five tests that may be performed on the turbines, including duration, safety and function, power performance, and power quality tests. The acoustic noise test was conducted to the IEC 61400-11 Edition 2.1.

17 WIND ENERGY↗

Next-Generation Performance-Based Regulation: Emphasizing Utility Performance to Unleash Power Sector Innovation

Performance-based regulation (PBR) enables regulators to reform hundred-year-old regulatory structures to unleash innovations within 21st century power systems. An old regulatory paradigm built to ensure safe and reliable electricity at reasonable prices from capital-intensive electricity monopolies is now adjusting to a new century of disruptive technological advances that change the way utilities make money and what value customers expect from their own electricity company. Advanced technologies are driving change in power sectors around the globe. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. These emerging technology drivers include renewable generation, distributed energy resources such as distributed generation and energy storage, demand-side management measures such as demand-response, electric vehicles, and smart grid technologies and energy efficiency (EE). PBR enables regulators to recognize the value that electric utilities bring to customers by enabling these advanced technologies and integrating smart solutions into the utility grid and utility operations. These changes in the electric energy system and customer capacities means that there is an increasing interest in motivating regulated entities in other areas beyond traditional cost-of-service performance regulation. This report addresses best practices gleaned from more than two decades of PBR in practice, and analyzes how those best practices and lessons can be used to design innovative PBR programs. Readers looking for an introduction to PBR may want to focus on Chapters 1-5. Chapters 6 and 7 contain more detail for those interested in the intricate workings of PBR or particularly innovative PBR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Increasing Main Cooler Thermal Performance for sCO2 Power Cycles

Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For mixed mean temperatures away from the pseudocritical temperature, the heat transfer coefficient matched the Dittus-Boelter correlation. As the mixed mean temperature approached the pseudocritical temperature, the heat transfer coefficient deviated from the Dittus-Boelter correlation due to transverse property variation and buoyancy. The local and average heat transfer coefficients for angled rib tubes were nominally 150% to 300% greater than the heat transfer coefficients for the smooth tube. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.

Searle, Matthew↗