Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Restoration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning for Resilient Power and Energy Systems: Progress, Prospects, and Future Avenues

In recent years, deep reinforcement learning (DRL) has garnered substantial attention in the context of enhancing resilience in power and energy systems. Resilience, characterized by the ability to withstand, absorb, and quickly recover from natural disasters and human-induced disruptions, has become paramount in ensuring the stability and dependability of critical infrastructure. This comprehensive review delves into the latest advancements and applications of DRL in enhancing the resilience of power and energy systems, highlighting significant contributions and key insights. The exploration commences with a concise elucidation of the fundamental principles of DRL, highlighting the intricate interplay among reinforcement learning (RL), deep learning, and the emergence of DRL. Furthermore, it categorizes and describes various DRL algorithms, laying a robust foundation for comprehending the applicability of DRL. The linkage between DRL and power system resilience is forged through a systematic classification of DRL applications into five pivotal dimensions: dynamic response, recovery and restoration, energy management and control, communications and cybersecurity, and resilience planning and metrics development. This structured categorization facilitates a methodical exploration of how DRL methodologies can effectively tackle critical challenges within the domain of power and energy system resilience. The review meticulously examines the inherent challenges and limitations entailed in integrating DRL into power and energy system resilience, shedding light on practical challenges and potential pitfalls. Additionally, it offers insights into promising avenues for future research, with the aim of inspiring innovative solutions and further progress in this vital domain.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accessibility and Availability of Gas Stations for Liquid Fuel Supply During Severe Weather Events

Energy infrastructure is a pivotal lifeline with wider inter-dependencies. Electric power is essential to the continued functioning of critical assets; liquid fuels and other physical primary energy commodities that are used to supply the local energy needs of these assets during extreme events when electricity infrastructure is compromised. During Superstorm Sandy, the disruption of fuel supplies in the Tri-state area necessitated increasing situational awareness about oil and natural gas (ONG) systems to redirect fuel supplies to first responders and for restoration efforts. During winter storm events over the past several years, the demand for ONG for heating and power generation has skyrocketed in the north-east, which subsequently had caused ONG price to hit their highest level in years. ONG is a major energy source for restoration and recovery activities. However, very little, if any, situational awareness information about ONG supply and demand is available to those coordinating emergency efforts. Often this lack of information is due to the decentralized nature of the ONG supply chain and proprietary data maintained by private entities. To understand the impact of fuel availability on response and recovery efforts, this research focuses on (i) determining the accessibility to gas stations for liquid fuel supply across space and time, and (ii) examining the spatio-temporal variation of fuel availability and demand during extreme weather events. The broader scope of the project focuses on providing spatio-temporal situational awareness information about ONG availability and demand across the fuel supply chain for positioning of resources for response activities.

Kar, Bandana↗

Analog-to-digital converter based on voltage-controlled superconducting devices

The increasing demand for cryogenic electronics in superconducting and quantum computing systems calls for ultra-energy-efficient data conversion architectures that remain functional at deep cryogenic temperatures. Here, in this work, we present the first design of a voltage-controlled superconducting flash analog-to-digital converter (ADC) based on a voltage-controlled quantum-enhanced Josephson junction field-effect transistor (JJFET). Exploiting its strong gate tunability and transistor-like behavior, the JJFET offers a scalable alternative to conventional current-controlled superconducting devices while aligning naturally with CMOS-style design methodologies. Building on our previously developed Verilog-A compact model calibrated to experimental data, we design and simulate a three-bit JJFET-based flash ADC targeted for integration within cryogenic control and readout circuitry in quantum computing. The core comparator block is realized through careful bias current selection and augmented with a three-terminal nanocryotron to precisely define reference voltages. Cascaded JJFET comparators ensure robust voltage gain, cascadability, and logic-level restoration across stages. Simulation results demonstrate accurate quantization behavior with ultra-low power dissipation, underscoring the feasibility of voltage-driven superconducting mixed-signal circuits. This work establishes a critical step toward unifying superconducting logic and data conversion, paving the way for scalable cryogenic architectures in quantum–classical co-processors, low-power artificial intelligence accelerators, and next-generation energy-constrained computing platforms.

Analog-to-digital converter↗

Torque control for electric motors

Method for adjusting electric-motor torque output to accomodate various loads utilizes phase-lock loop to control relay connected to starting circuit. As load is imposed, motor slows down, and phase lock is lost. Phase-lock signal triggers relay to power starting coil and generate additional torque. Once phase lock is recoverd, relay restores starting circuit to its normal operating mode.

Bernard, C. A.↗

Technical Aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation, due to a failure in the Side 2 Low Voltage Power Supply (LVPS2). LVPS2 provided power to the entire instrument, including all detectors and mechanisms. Following the LVPS2 failure, a team was assembled to analyze the fault and to determine if STIS repair (STIS-R) was feasible. The team concluded that by replacing a power supply board within LVPS2, STIS could be brought back to full functionality. STIS-R will be conducted during Servicing Mission 4 (SM4), and will consist of replacing the power supply board and a new passive cooling system. STIS-R will restore full function of the instrument with one of the two redundant sides of the instrument. In this presentation, we focus on the technical aspects associated with STISR.

Rinehart, Stephen↗

On the Formalization of Development and Assessment Process for Digital Twins in the Nearly Autonomous Management and Control System

In recent years, the autonomous control system has been encouraged in advanced reactors for restoring economic viability, simplifying the operation and maintenance, and enabling remote-site power generations [1]. Since the reactor is expected to be operated for a long period of time with a limited number of individuals onsite, it is recommended that the autonomous control system should have access to very realistic models of the state of processes in the whole lifecycle, together with these process behaviors in interaction with their environment in the real world. As a result, digital twin (DT) technology is suggested in autonomous control systems. DT is defined as a digital representation of a physical object or system, which contains a record for the histories of loads, operation and maintenance status, predictions for the near-term transient of important state variables, and decision-making process [2]. Since machine learning (ML) can recognize patterns within a complex system in real-time applications, it has been used to build DTs in the autonomous control systems for advanced reactors. Meanwhile, due to the rareness of operation data in accident scenarios, the development and assessment of DTs is expected to be mainly driven by simulations. Although the capability and feasibility of ML-based DTs are recognized in improving the safety and efficiency of reactor control, a major concern from the regulatory commission and the nuclear industry is whether the information from a DT is developed and assessed in accordance with expectation and requirements by the target decision. Such concerns not only affect the acceptance criteria for DTs, but also values that can be extracted from DTs and autonomous control system during operations. Inspired by the success of formal methods in improving the reliability and robustness of computer programming and software development, it is suggested that the development and assessment process (DAP) for both separate DTs and integral control system should be formalized in a transparent, consistent, and improvable manner. In this study, a digital-twin development and assessment process (DT-DAP) is proposed by adapting the evaluation model development and assessment process (EMDAP) [3] to requirements by the autonomous control system, ML algorithms, and DT technology. To demonstrate the framework, a baseline nearly autonomous management and control (NAMAC) system with ML-based DTs for diagnosis and prognosis is developed and assessed based on the framework. It is found that with selected testing methods and techniques, the DT-DAP can help identify errors in DTs and NAMAC which would otherwise be left unverified. Meanwhile, it is found that the DT-DAP can improve the DTs and NAMAC by continuously learning and iterating through different elements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

Cyber-Physical Reconfiguration for Disaster Resilience of Power Distribution Systems

Cyber-physical distribution systems (CPDS) have emerged from the integration of information technology into distribution systems. While offering substantial benefits, this integration also introduces vulnerabilities. The interaction between cyber networks and distribution systems renders CPDS susceptible to disasters. To ensure critical load supply and system resilience, rapid post-disaster load restoration is required. The paper proposes a critical load restoration (CLR) framework in CPDS using a network reconfiguration approach that exploits the existing post-disaster resources to restore critical loads within the shortest possible time. Using graph theory, the cyber network and distribution system are integrated into a single digraph, minimizing the CLR complexity in CPDS. A cost metric is also defined to satisfy network-specific objectives and constraints. A heuristic is proposed to guide the load restoration process using the cost metric within the integrated digraph. Simulation results confirm the framework's superiority over existing literature, which either overlooks cyber components or prolongs restoration with additional resource deployment.

cyber-physical system↗

Floating Island International PHASE I FINAL TECHNICAL REPORT (Advancing the Development of Floating Solar-Powered Nanobubble Aeration Systems for Use with Floating Treatment Wetlands in Natural and Man-Made Waterbodies)

More and more freshwater lakes are suffering from algae blooms, which deprive water of oxygen and lead to widespread loss of aquatic life and production of dangerous toxins. When oxygen is lacking, methane is generated in the sediments as algae is decomposed; it has been calculated that more than half of global methane emissions come from nutrient-impaired freshwater systems (Beaulieu, 2021). Nutrients, mainly from agricultural run-off, feed algae blooms and are exacerbated by warming related to climate change. Artificial aeration is frequently used to restore oxygen to a waterbody. But diffuser aeration is inefficient and expensive, needs on-site grid power, and is failing to keep pace with the demands of water as it gets warmer with climate change. In the last five years, nanobubble aeration has been introduced into freshwater applications and shows promise for rapidly increasing dissolved oxygen effectively throughout the water column. Nanobubbles deliver oxygen in bubbles that have no buoyancy, so they stay in water longer and release their oxygen more fully, compared to large bubbles that rise and burst at the surface. The prospect of this new technology answering the deficiencies of diffuser aeration drove us to initiate the current project. During our Phase I period, we have successfully tested a nanobubble aeration system that can super-saturate oxygen levels. It is operated on solar power, and both the nanobubbler and solar array are mounted on a proprietary floating island platform, that also performs biological nutrient recycling. A rudimentary system was assembled and tested on a 6.5-acre research lake at our headquarters in Montana, where it was subjected to a summer drought that reduced water levels significantly, periods of severe cold in winter, and spring conditions that included heavy rainfall and violent thunderstorms. Our twice-weekly sampling throughout the project showed that dissolved oxygen levels rose rapidly and were maintained throughout winter and spring, well into June. The nanobubbler was able to run on solar power for long periods. Methane levels were tested periodically and found to decrease as oxygen increased. The nanobubbles appeared to have no adverse impact on fish or other aquatic life exposed to them. The stability of the installation survived the weather conditions. The many problems we encountered taught us what we need to improve in the next iteration. Towards the end of our Phase I, we were awarded a supplementary state grant that enabled us to acquire a new nanobubble system for testing that runs on DC, is extremely efficient and has few moving parts. We plan to team this with low-profile solar panels, lithium batteries and a controller that provides real-time data. The ultimate goal of this project is to commercialize an affordable and scalable lake management system that will oxygenate water from the surface down to the sludge. It will enliven fisheries, prevent toxic algae blooms and – most importantly for the fate of our planet - inhibit the production and release of methane from the sediments. We anticipate that as carbon credits expand to include methane, the cost of remediating waterbodies that produce methane will be offset. We firmly believe that this is a practical technology that works and will make a big difference when fully implemented.

14 SOLAR ENERGY↗

Black-Starting Microgrids Using Inverter-Based Distributed Energy Resources

Recent trends in power systems show increasing deployment of inverter-based distributed energy resources (DERs) at the distribution level. Efforts have also been made to use inverter-based DERs for system restoration of critical sections of distribution feeders. In the past few years, there has been active consideration of using local grid-forming (GFM) DERs, which can form their own voltage and frequency, to black-start microgrids instead of waiting for the bulk system for supply restoration. However, using current-limited inverter-based DERs for black-start operations with high inrush currents can pose some technical challenges. This paper presents detailed electromagnetic transient studies on a digital real-time simulator to assess the operational feasibility of using local inverter-based GFM DERs for microgrid black-start operations as a bottom-up approach instead of a top-down approach where the substation is used to restore critical sections of the feeder. The paper presents key modeling details for distribution system components for studying GFM DER-based microgrid black-start operations. The paper presents simulation results comparing different black-start approaches using GFM DERs for two test systems: i) a simple test microgrid and ii) a real-world utility microgrid currently being designed and deployed by Holy Cross Energy in Colorado.

black start↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Dynamic response and stability of a gas-lubricated Rayleigh-step pad

The quasi-static, pressure characteristics of a gas-lubricated thrust bearing with shrouded, Rayleigh-step pads are determined for a time-varying film thickness. The axial response of the thrust bearing to an axial forcing function or an axial rotor disturbance is investigated by treating the gas film as a spring having nonlinear restoring and damping forces. These forces are related to the film thickness by a power relation. The nonlinear equation of motion in the axial mode is solved by the Ritz-Galerkin method as well as the direct, numerical integration. Results of the nonlinear response by both methods are compared with the response based on the linearized equation. Further, the gas-film instability of an infinitely wide Rayleigh step thrust pad is determined by solving the transient Reynolds equation coupled with the equation of the motion of the pad. Results show that the Rayleigh-step geometry is very stable for bearing number A up to 50. The stability threshold is shown to exist only for ultrahigh values of Lambda equal to or greater than 100, where the stability can be achieved by making the mass heavier than the critical mass.

Cheng, C.↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Lunar Surface temperatures can span from equatorial highs near 400K and polar lows of 50K. The extreme cold combined with the 354-hour duration of the lunar night is particularly challenging for small robotic lander missions. NASA’s Commercial Lunar Payload Services (CLPS) missions involve robotic landers intended to provide low-cost access to the lunar surface. Current CLPS Missions are solar powered and are only intended to survive a single lunar day. The ability to survive the night and continue operations over many lunar cycles would provide a dramatic increase in science productivity. The Power Hibernation approach relies on battery cells that can tolerate the extreme cold night and recover once temperatures return to normal. System recovery from hibernation depends on power electronics that can “cold start” at lunar dawn and operate on solar array output alone. Once battery and avionics systems are restored the spacecraft resumes daytime operations. The challenge is to achieve this capability with minimum impact to the spacecraft design and payload capacity. This talk will describe recent and ongoing investigations in battery and electronics technologies that will enable power hibernation and recovery.

Space Power↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Lunar Surface temperatures can span from equatorial highs near 400K and polar lows of 50K. The extreme cold combined with the 354-hour duration of the lunar night is particularly challenging for small robotic lander missions. NASA’s Commercial Lunar Payload Services (CLPS) missions involve robotic landers intended to provide low-cost access to the lunar surface. Current CLPS Missions are solar powered and are only intended to survive a single lunar day. The ability to survive the night and continue operations over many lunar cycles would provide a dramatic increase in science productivity. The Power Hibernation approach relies on battery cells that can tolerate the extreme cold night and recover once temperatures return to normal. System recovery from hibernation depends on power electronics that can “cold start” at lunar dawn and operate on solar array output alone. Once battery and avionics systems are restored the spacecraft resumes daytime operations. The challenge is to achieve this capability with minimum impact to the spacecraft design and payload capacity. This talk will describe recent and ongoing investigations in battery and electronics technologies that will enable power hibernation and recovery.

Space Power↗

Safeguarding the Grid: Diverse Resources for Resilience [In My View]

Reports on the vulnerability of the power grid. From wildfires, hurricanes, and floods to cyberattacks, the grid is vulnerable to natural and human-made disasters, which can cause widespread outages that last from hours to months and leave lasting economic impacts. Imagine a coastal region in the United States that has just been hit by a hurricane and lost all power. Besides the electricity infrastructure going out, communications networks, rail transportation, and gasoline pumps may also stop working after the emergency event, which often delays repair efforts to the grid. Unresponsive communications make it difficult to dispatch workers to repair the grid, and missing transportation links delay shipments of replacement equipment for the grid’s restoration.

cybersecurity↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power spectral ensity of markov texture fields

Texture is an important image characteristic. A variety of spatial domain techniques were proposed for extracting and utilizing textural features for segmenting and classifying images. for the most part, these spatial domain techniques are ad hos in nature. A markov random field model for image texture is discussed. A frequency domain description of image texture is derived in terms of the power spectral density. This model is used for designing optimum frequency domain filters for enhancing, restoring and segmenting images based on their textural properties.

Shanmugan, K. S.↗