Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Carbon Arc Apparatus For Production Of Nanotubes In Microgravity

Although many methods are available for production of single-walled carbon nanotubes (SWNTs), the conventional carbon arc process remains the most popular due to its simplicity and large production rate. However, high temperatures inside the carbon arc generate strong buoyancy driven convection, and it is hypothesized that the non-uniform environment created by this flow will have large effects on the growth and morphology of SWNTs produced by the arc process. Indeed, using normal gravity experiments, Marin et al. have demonstrated that changes in the buoyant convection plume produced by altering the arc electrode orientation can be used to change the diameter distribution of the SWNTs produced; an effect they attribute to changes in the temperature of the local nanotube growth environment. While these experiments present convincing evidence that buoyant convection has a strong effect on nanotube growth, normal gravity experiments are severely limited in scope. The ideal way to study the effect of buoyancy on SWNT production is to remove it completely. Toward this goal, a microgravity carbon arc reactor has been designed for use in the NASA Glenn 2.2 and 5 second drop towers. Although simple in principle, conventional carbon arc machines, which generally employ large reaction chambers and require heavy duty welding power supplies capable of supplying kilowatts of power, are not suitable for microgravity experiments. Here we describe a miniature carbon arc machine for SWNT production that fits into a conventional drop rig for use on the NASA Glenn 2.2 and 5 second drop towers, but that has a performance (production rate) that is better than most large ground-based machines.

Alford, J. M.↗

Recovering the Waste Energy from the Electron-Ion Collider Cooling Water Systems

While only a fraction of the electricity required for the EIC goes into the collision itself, most of the energy ultimately ends up being rejected to the environment via the infrastructure cooling systems. The energy utilized by the RF amplifiers, power supplies, magnets, vacuum systems, and cryogenics systems is rejected to the cooling towers that ultimately dissipate the energy to the atmosphere. Current estimates indicate approximately 50 MW of heat is dissipated at a low temperature by the cooling towers. This technical note is prepared to conceptually demonstrate that feasible options exist to recover the low temperature energy from the EIC cooling water systems.

43 PARTICLE ACCELERATORS↗

Thunderstorm detection and warning system atmospheric potential monitor

An new type of electric field instrumentation was developed for lighting prediction at KSC. Currently, it is being installed at several government laboratories and is being made available to the public. It has important advantages over the previous method for measuring electric fields with motor driven field mills: (1) it has no moving parts and requires little maintenance compared to rotating machinery; (2) it is unaffected by rain, snow, sand, or insects, all of which can influence field mills; and (3) the lightweight sensor can be mounted easily on a tall mast. By mounting the instrumentation on a tall mast the instrumentation is placed above much of the blanket of point discharge ions that are emitted from objects on the ground during thunderstorms. This space charge limits the ability of any ground based electric field sensor to accurately measure cloud electric fields which produce lightning. The elevated mounting was demonstrated to significantly improve monitoring of thunderstorm electric fields. This instrumentation measures the atmospheric potential relative to earth at a corona needle sensor on top of a mast which normally is mounted on a tower or roof. The needle is kept in corona at all times by a low power high voltage power supply. This produces a small cloud of ions around the needle allowing a current to flow. Measurement of the current provides the atmospheric potential. The potential divided by the height of the needle above the ground is proportional to the average electric field between the needle and earth. The potential on top of a tall pole or above a rooftop is more representative of the intensity of cloud electrification than electric field measurements made at ground level. Photographs that depict the computer terminal, video display of a two sensor system, and the individual components installed on a tower are presented.

Source record↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

Informing Transmission Supply Chain Needs from National Transmission Studies

Recent national studies indicate significant transmission expansion can provide the lowest-cost option to maintain grid reliability while meeting growing demand. However, constraints in domestic supply chains may limit grid expansion across the U.S., with higher costs and longer delays for required transmission equipment. Despite growing evidence of supply chain constraints for transmission components, transmission planning studies often assume transmission equipment is readily available for deployment or analyze future demand using historical trade and manufacturing data that may not capture evolving grid needs. This report aims to address this gap by demonstrating methods to quantify future demand for critical transmission components and input materials from national-scale planning models. These components include power transformers, generator step-up transformers, converter transformers, conductors, circuit breakers, and transmission towers and the materials include aluminum, steel, grain-oriented electrical steel (GOES), and copper. The analytical approach is applied to two nodal transmission expansion scenarios from the National Transmission Planning Study (NTP) to illustrate the methods. These scenarios represent different transmission expansion strategies for the contiguous U.S. to the year 2035: the Alternating Current (AC) scenario includes AC transmission expansion within each interconnection and the Multiterminal (MT) scenario includes interregional transmission expansion across the country using both AC and multiterminal HVDC options between neighboring zones. We also explore potential heuristics to derive transmission component demand from zonal capacity expansion models (CEMs) with coarse representation of the transmission grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Informing Transmission Supply Chain Needs from National Transmission Studies

Recent national studies indicate significant transmission expansion can provide the lowest-cost option to maintain grid reliability while meeting growing demand. However, constraints in domestic supply chains may limit grid expansion across the U.S., with higher costs and longer delays for required transmission equipment. Despite growing evidence of supply chain constraints for transmission components, transmission planning studies often assume transmission equipment is readily available for deployment or analyze future demand using historical trade and manufacturing data that may not capture evolving grid needs. This report aims to address this gap by demonstrating methods to quantify future demand for critical transmission components and input materials from national-scale planning models. These components include power transformers, generator step-up transformers, converter transformers, conductors, circuit breakers, and transmission towers and the materials include aluminum, steel, grain-oriented electrical steel (GOES), and copper. The analytical approach is applied to two nodal transmission expansion scenarios from the National Transmission Planning Study (NTP) to illustrate the methods. These scenarios represent different transmission expansion strategies for the contiguous U.S. to the year 2035: the Alternating Current (AC) scenario includes AC transmission expansion within each interconnection and the Multiterminal (MT) scenario includes interregional transmission expansion across the country using both AC and multiterminal HVDC options between neighboring zones. We also explore potential heuristics to derive transmission component demand from zonal capacity expansion models (CEMs) with coarse representation of the transmission grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

Thermoplastic Space Point Design (TSPD) Tall Tower Lunar Thermal Analysis

The Thermoplastics Development for Exploration Applications (TDEA) project seeks to advance NASA’s thermoplastic composites capabilities by developing structurally efficient joining solutions for large-scale space structures to support NASA’s future exploration missions. A key objective is to develop and understand advanced thermoplastic joining techniques relevant to space environments and applicable to unitized and/or reconfigurable composite structures. The TDEA project uses NASA Langley’s Tall Lunar Tower (TLT) concept as a target application for the design and development of in-space assembled thermoplastic composites. TLT is a 50-meter-tall tower constructed on the lunar surface near the south pole. The tower’s height at this location on the moon allows for extended durations of incident solar flux which can be used to generate power via photovoltaic arrays. The thermal environment present on lunar south pole represents a challenging environment for any space-based asset. This study provides an overview of the analysis techniques used to determine the temperature extremes, gradients, and timelines of a tall composite tower over a one-year duration at the Shackleton Connecting Ridge. The developed thermal model includes tower and lunar surface elements with anisotropic and temperature-dependent material properties and incorporates a solar vector orbit with time-varying solar flux. Study topics include: a comparison between the effects of simplified lunar surface topologies on thermal results, prediction of surface temperature values versus Lunar Reconnaissance Orbiter (LRO) flight data, and tower structural-thermal deformation.

Lunar↗

Modeling Offshore Wind Farm Performance in Coastal Low-Level Jets Using Coupled Mesoscale-Microscale Large Eddy Simulations

Accurately predicting wind farm reliability under complex offshore atmospheric conditions remains a key challenge, particularly during noncanonical meteorological events such as coastal low-level jets (LLJs). LLJs, characterized by strong nonmonotonic vertical shear and directional veer, depart significantly from the simplified inflow assumptions embedded in conventional design standards, low-fidelity engineering models, and microscale large eddy simulations of the atmospheric boundary layer. In this work, we use the virtual wind farm framework—an exascale, graphics processing unit–accelerated large eddy simulation platform coupled with high-fidelity aeroservoelastic turbine models and advanced mesoscale-microscale coupling via the ExaWind software stack—to investigate turbine responses under realistic LLJ forcing. Simulations are performed over the U.S. North Atlantic offshore domain with the use of meteorological inputs from New York State Energy Research and Development Authority buoy data, focusing on a representative LLJ case impacting the International Energy Agency 15 MW reference turbine. Our results show that LLJs can cause up to 50% power deficits in downstream turbine rows and significantly amplify low-speed shaft and tower loads through nonlinear coupling between complex inflow characteristics and turbine structural dynamics. Two primary mechanisms drive these load amplifications: (1) unique LLJ inflow features—including veer and vertical/lateral shear—and (2) the downstream evolution of the flow under stable thermal stratification, which suppresses turbulence mixing and alters wake recovery. These mechanisms produce streamwise variations in turbine loading not captured by standard hub height–based metrics or existing design load case (DLC) definitions. This study highlights the critical role of rotor-scale flow gradients in driving fatigue and system-level aeroelastic responses, challenging current DLC and control strategies. We advocate the integration of full-flow field, environment-aware wind inputs into load modeling and control algorithms. By leveraging exascale computing to resolve mesoscale-microscale coupling, this work lays the groundwork for next-generation offshore wind turbine design and operation in meteorologically complex marine environments.

17 WIND ENERGY↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

The Oregon State University wind studies

The economic feasibility of commercial use of wind generated power in selected areas of Oregon is assessed. A number of machines for generating power have been examined. These include the Savonius rotor, translators, conventional wind turbines, the circulation controlled rotor and the vertical axis winged turbine. Of these machines, the conventional wind turbine and the vertical axis winged turbine show the greatest promise on the basis of the power developed per unit of rotor blade area. Attention has been focused on the structural and fatigue analysis of rotors since the economics of rotary winged, wind generated power depends upon low cost, long lifetime rotors. Analysis of energy storage systems and tower design has also been undertaken. An economic means of energy storage has not been found to date. Tower design studies have produced cost estimates that are in general agreement with the cost of the updated Putnam 110-foot tower.

Wilson, R. E.↗

Offshore Space Center (offshore launch site)

Any activity requiring the development of the HLLV can benefit by operations from an offshore space center (OSC) since operating near the equator provides a twenty percent increase in payload in an ecliptic plan orbit. Some OSC concepts considered include a moored floating (semisubmersible) design, a stationary design supported by fixed piles, and a combination of these two. The facility supports: a 15,000 foot long, 300 foot wide runway, designed to accommodate a two staged winged launch vehicle, with a one million pound payload capacity to low earth orbit; an industrial area for HLLV maintenance; an airport terminal, control and operation center, and observation tower; liquid hydrogen and liquid oxygen production and storage, and fuel storage platforms; a power generation station, docks with an unloading area; two separate launch sites; and living accommodations for 10,000 people. Potential sites include the Paramount Seamount in the Pacific Ocean off the north coast of South America. Cost estimates are considered.

Harvey, D. G.↗

Simultaneous measurements of sunspot umbral oscillations in the photosphere, chromosphere, and transition region

Measurements of umbral oscillations in a sunspot were made simultaneously from space (with the SMM/UVSP instrument) in the C IV transition-region line and from the ground (with the tower telescope at NSO/sunspot) in spectral lines formed in the photosphere and chromosphere. The power spectra of velocity and intensity variations show multiple peaks in the 3 min band (4.5-10 mHz). A strong oscillation at 5.5 mHz is coherent between the chromosphere and transition region. Another strong oscillation mode at 7.5 mHz is coherent between the photosphere and transition region and appears to have a node in the chromosphere. The rms velocity in the 3 min band is a little over 12 km/sec in both the chromosphere and transition region, but the kinetic energy density is lower in the transition region (by a factor of 10 or more) due to the lower mass density there. These measurements of amplitude and phase of the waves at different heights provided a new, independent method of testing or fitting models of the vertical temperature distribution in the umbral chromosphere and transition regions.

Thomas, John H.↗

Leaf temperature raw data, 2015 - 2017, at Manaus, Brazil

This data package contains raw leaf surface temperature data from the NGEE Tropics K34 tower site on a plateau near Manaus, Brazil, including automated and manually collected time series data on leaf surface temperature (thermocouples, IR radiometer, thermocamera). Leaf surface temperature (LST) was determined throughout diurnal periods using individual type T thermocouples (Omega Engineering) on 8 individual leaves of a single tree. Mature leaves at the same height and general area near the tower were selected. LST measurements were taken every 15 s and recorded on a field portable self-powered data logger (OM-CP-OCTTEMP-A, Omega Engineering). Measurements were stopped in the case of a storm or rain which can remove the attached thermocouple wires from the leaf due to large wind-driven branch movements. Included in the attached zip file are six folders: three with LST data in Excel and CSV file formats from both the K34 and B34 towers, one folder with data logger configuration programs that were used for data collection, a fifth folder with PDF files of manuals for instruments used and a final folder with two Excel metadata files. See dataset references for associated metadata package. This dataset replaces the leaf surface temperature data of two retired packages, http://dx.doi.org/10.15486/ngt/1507764 and http://dx.doi.org/10.15486/ngt/1507767

54 ENVIRONMENTAL SCIENCES↗

In-Space Transportation for GEO Space Solar Power Satellites

This report summarizes results of study tasks to evaluate design options for in-space transportation of geostationary Space Solar Power Satellites. Referring to the end-to-end architecture studies performed in 1988, this current activity focuses on transportation of Sun Tower satellite segments from an initial low Earth orbit altitude to a final position in geostationary orbit (GEO; i.e., 35,786 km altitude, circular, equatorial orbit). This report encompasses study activity for In-Space Transportation of GEO Space Solar Power (SSP) Satellites including: 1) assessment of requirements, 2) design of system concepts, 3) comparison of alternative system options, and 4) assessment of potential derivatives.

Martin, James A.↗