Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power offset”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High-performance InGaP/GaAs pnp {delta}-doped heterojunction bipolar transistor

In this article, a novel InGaP/GaAs pnp {delta}-doped heterojunction bipolar transistor is first demonstrated. Though the valence band discontinuity at InGaP/GaAs heterojunction is relatively large, the addition of a {delta}-doped sheet between two spacer layers at the emitter-base (E-B) junction effectively eliminates the potential spike and increases the confined barrier for electrons, simultaneously. Experimentally, a high current gain of 25 and a relatively low E-B offset voltage of 60 mV are achieved. The offset voltage is much smaller than the conventional InGaP/GaAs pnp HBT. The proposed device could be used for linear amplifiers and low-power complementary integrated circuit applications.

36 MATERIALS SCIENCE↗

Measurement-driven large-eddy simulations of a diurnal cycle during a wake-steering field campaign

Abstract. High-fidelity flow modeling with data assimilation enables accurate representation of the wind farm operating environment under realistic, nonstationary atmospheric conditions. Capturing the temporal evolution of the turbulent atmospheric boundary layer is critical to understanding the behavior of wind turbines under operating conditions with simultaneously varying inflow and control inputs. This paper has three parts: the identification of a case study during a field evaluation of wake steering; the development of a tailored mesoscale-to-microscale coupling strategy that resolved local flow conditions within a large-eddy simulation (LES), using observations that did not completely capture the wind and temperature fields throughout the simulation domain; and the application of this coupling strategy to validate high-fidelity aeroelastic predictions of turbine performance and wake interactions with and without wake steering. The case study spans 4.5 h after midnight local time, during which wake steering was toggled on and off five times, achieving yaw offset angles ranging from 0 to 17°. To resolve nonstationary nighttime conditions that exhibited shear instabilities, the turbulence field was evolved starting from the diurnal cycle of the previous day. These background conditions were then used to drive wind farm simulations with two different models: an LES with actuator disk turbines and a steady-state engineering wake model. Subsequent analysis identified two representative periods during which the up- and downstream turbines were most nearly aligned with the mean wind direction and had observed yaw offsets of 0 and 15°. Both periods corresponded to partial waking on the downstream turbine, which had errors in the LES-predicted power of 4 % and 6 %, with and without wake steering. The LES was also able to capture conditions during which an upstream turbine wake induced a speedup at a downstream turbine and increased power production by up to 13 %.

17 WIND ENERGY↗

Offset-aligned three-dimensional integrated circuit

A three-dimensional integrated circuit includes a first die having a first geometry. The first die includes a first region that operates with a first power density and a second region that operates with a second power density. The first power density is less than the second power density. The first die includes first electrical contacts disposed in the first region on a first side of the first die along a periphery of the first die. The three-dimensional integrated circuit includes a second die having a second geometry. The second die includes second electrical contacts disposed on a first side of the second die. A stacked portion of the second die is stacked within the periphery of the first die and an overhang portion of the second die extends beyond the periphery of the first die. The second electrical contacts are aligned with and coupled to the first electrical contacts.

42 ENGINEERING↗

Integrated, Automated Distributed Generation Technologies Demonstration

The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kW new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.

17 WIND ENERGY↗

1D Transient Study of Glidcop Surface Heating by Beam Power

Radiation fans from Insertion Devices and Bending Magnets are “trimmed” by various water-cooled absorbers located strategically downstream of those sources. Mostly, the absorber surfaces onto which power is deposited is constructed from Glidcop (rarely OFHC copper). A ring-resident Active Interlock (AI) system is designed to protect against overheating by disabling mis-steered beam within an allotted time. The Synchrotron Radiation Protection (SRP) protocol has the limiting criterion of 100*C maximum allowable temperature at any point when subject to mis-steered beam for a fixed period before the AI takes action. After 0.2 msec, radiation in excess of the +/- 500 um offset and +/- 250 urad angular error from the HEX SCW will trip in fault. AI specified beam parameters allow 1.0 msec to fully dump the electron beam. Given such short periods of peak power deposition we explore here these brief thermal transients to glean a general understanding of highest reachable limits before the onset of AI protection.

36 MATERIALS SCIENCE↗

Regulation control and energy management scheme for wireless power transfer

Power transfer rate at a charging facility can be maximized by employing a feedback scheme. The state of charge (SOC) and temperature of the regenerative energy storage system (RESS) pack of a vehicle is monitored to determine the load due to the RESS pack. An optimal frequency that cancels the imaginary component of the input impedance for the output signal from a grid converter is calculated from the load of the RESS pack, and a frequency offset f* is made to the nominal frequency f.sub.0 of the grid converter output based on the resonance frequency of a magnetically coupled circuit. The optimal frequency can maximize the efficiency of the power transfer. Further, an optimal grid converter duty ratio d* can be derived from the charge rate of the RESS pack. The grid converter duty ratio d* regulates wireless power transfer (WPT) power level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Near-Infrared Ternary Tandem Solar Cells

The paucity of near-infrared (NIR) organic materials with high absorption at long wavelengths, combined with large diffusion lengths and charge mobilities, is an impediment to progress in achieving high-efficiency organic tandem solar cells. Here a subcell is employed within a series tandem stack that comprises a solution-processed ternary blend of two NIR-absorbing nonfullerene acceptors and a polymer donor combined with a small-molecular-weight, short-wavelength fullerene-based subcell grown by vacuum thermal evaporation. Additionally, the ternary cell achieves a power conversion efficiency of 12.6 ± 0.3% with a short-circuit current of 25.5 ± 0.3 mA cm -2 , an open-circuit voltage of 0.69 ± 0.01 V, and a fill factor of 0.71 ± 0.01 under 1 sun, AM 1.5G spectral illumination. The success of this device is a result of the nearly identical offset energies between the lowest unoccupied molecular orbitals (LUMOs) of the donors with the highest occupied molecular orbital (HOMO) of the acceptor, resulting in a high open-circuit voltage. A tandem structure with an antireflection coating combining these subcells demonstrates a power conversion efficiency of 15.4 ± 0.3%.

36 MATERIALS SCIENCE↗

A continuum of H- to He-rich tidal disruption candidates with a preference for E+A galaxies

We present the results of a Palomar Transient Factory (PTF) archival search for blue transients that lie in the magnitude range between 'normal' core-collapse and superluminous supernovae (i.e., with –21 ≤ M {sub R} {sub (peak)} ≤ – 19). Of the six events found after excluding all interacting Type IIn and Ia-CSM supernovae, three (PTF09ge, 09axc, and 09djl) are coincident with the centers of their hosts, one (10iam) is offset from the center, and a precise offset cannot be determined for two (10nuj and 11glr). All the central events have similar rise times to the He-rich tidal disruption candidate PS1-10jh, and the event with the best-sampled light curve also has similar colors and power-law decay. Spectroscopically, PTF09ge is He-rich, while PTF09axc and 09djl display broad hydrogen features around peak magnitude. All three central events are in low star formation hosts, two of which are E+A galaxies. Our spectrum of the host of PS1-10jh displays similar properties. PTF10iam, the one offset event, is different photometrically and spectroscopically from the central events, and its host displays a higher star formation rate. Finding no obvious evidence for ongoing galactic nuclei activity or recent star formation, we conclude that the three central transients likely arise from the tidal disruption of a star by a supermassive black hole. We compare the spectra of these events to tidal disruption candidates from the literature and find that all of these objects can be unified on a continuous scale of spectral properties. The accumulated evidence of this expanded sample strongly supports a tidal disruption origin for this class of nuclear transients.

79 ASTRONOMY AND ASTROPHYSICS↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and system for managing power grid data

A system and method of managing time-series data for smart grids is disclosed. Data is collected from a plurality of sensors. An index is modified for a newly created block. A one disk operation per read or write is performed. The one disk operation per read includes accessing and looking up the index to locate the data without movement of an arm of the disk, and obtaining the data. The one disk operation per write includes searching the disk for free space, calculating an offset, modifying the index, and writing the data contiguously into a block of the disk the index points to.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MREG V1.1 : a multi-scale image registration algorithm for SAR applications.

MREG V1.1 is the sixth generation SAR image registration algorithm developed by the Signal Processing&Technology Department for Synthetic Aperture Radar applications. Like its predecessor algorithm REGI, it employs a powerful iterative multi-scale paradigm to achieve the competing goals of sub-pixel registration accuracy and the ability to handle large initial offsets. Since it is not model based, it allows for high fidelity tracking of spatially varying terrain-induced misregistration. Since it does not rely on image domain phase, it is equally adept at coherent and noncoherent image registration. This document provides a brief history of the registration processors developed by Dept. 5962 leading up to MREG V1.1, a full description of the signal processing steps involved in the algorithm, and a user's manual with application specific recommendations for CCD, TwoColor MultiView, and SAR stereoscopy.

Eichel, Paul H.↗

Variable Ion Compositions of Solar Energetic Particle Events in the Inner Heliosphere: A Field Line Braiding Model with Compound Injections

We propose a model for interpreting highly variable ion composition ratios in solar energetic particle (SEP) events recently observed by the Parker Solar Probe (PSP) at 0.3–0.45 au. We use numerical simulations to calculate SEP propagation in a turbulent interplanetary magnetic field with a Kolmogorov power spectrum from large scales down to the gyration scale of energetic particles. We show that when the source regions of different species are offset by a distance comparable to the size of the source regions, the observed energetic particle composition He/H can be strongly variable over more than two orders of magnitude, even if the source ratio is at the nominal value. Assuming a 3 He/ 4 He source ratio of 10% in impulsive 3 He-rich events and the same spatial offset of the source regions, the 3 He/ 4 He ratio at observation sites also vary considerably. The variability of the ion composition ratios depends on the radial distance, which can be tested by observations made at different radial locations. We discuss the implications of these results on the variability of ion composition of impulsive events and on further PSP and Solar Orbiter observations close to the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Offset-aligned three-dimensional integrated circuit

A three-dimensional integrated circuit includes a first die structure having a first geometry. The first die structure includes a first region that operates with a first power density and a second region that operates with a second power density. The first power density is less than the second power density. The three-dimensional integrated circuit includes a second die structure having a second geometry. A stacked portion of the second die structure is aligned with the first region. The three-dimensional integrated circuit includes an additional die structure stacked with the first die structure and the second die structure. The additional die structure has the first geometry or the second geometry.

Wilkerson, Brett P.↗

Performance and Economic Analysis of Distributed Power Electronics in Photovoltaic Systems

Distributed electronics like micro-inverters and DC-DC converters can help recover mismatch and shading losses in photovoltaic (PV) systems. Under partially shaded conditions, the use of distributed electronics can recover between 15-40% of annual performance loss or more, depending on the system configuration and type of device used. Additional value-added features may also increase the benefitof using per-panel distributed electronics, including increased safety, reduced system design constraints and added monitoring and diagnostics. The economics of these devices will also become more favorable as production volume increases, and integration within the solar panel?s junction box reduces part count and installation time. Some potential liabilities of per-panel devices includeincreased PV system cost, additional points of failure, and an insertion loss that may or may not offset performance gains under particular mismatch conditions.

14 SOLAR ENERGY↗

Narrow-Channel, Fluidized Beds for Effective Particle Thermal Energy Transport and Storage

Colorado School of Mines (Mines) led this program in collaboration with Sandia National Laboratories (Sandia) to characterize narrow-channel fluidized beds of aluminosilicate particles – supplied by Carbo Ceramics – as a means for releasing high-temperature thermal energy in particle heat exchangers and for capturing concentrated solar energy in indirect particle receivers. Single-channel, heat transfer experiments at Mines and reduced-order 1-D models and 3-D two-fluid, CFD models explored many aspects of counterflow, bubbling fluidized beds (net downward particle flow and upward gas flow) for enhancing particle-wall heat transfer at elevated temperatures. Results at Mines on single-channel test sections consistently showed that mild bubbling fluidization increases particle-wall heat transfer coefficients (h T,w ) regularly by more than 4.0x over h T,w values without fluidization at similar conditions (mean particle diameter d p , bed depth Δz b , and bed particle temperatures T p ). Insights from lab-scale tests and modeling studies provided Nusselt number correlations for h T,w and informed the design and fabrication (by Vacuum Process Engineering) of a nominal 40-kWth, particle-sCO 2 plate heat exchanger (HX) with 12 parallel narrow-channel, fluidized beds bounded by stainless-steel walls with embedded microchannels for high-pressure sCO 2 flows. Tests of the 40-kW th HX at the particle-sCO 2 HX test stand at Sandia's National Solar Thermal Test Facility (NSTTF) were limited, due to HX design, to particle inlet temperatures T p,in ≤ 520°C with maximum sCO 2 outlet temperatures T sCO2,out ≈ 440°C, which are well below design conditions for a primary HX in a sCO 2 power cycle for a Gen-3 concentrating solar power (CSP) plant. Total heat transfer $\dot{Q}_{HX}$ remains relatively constant with increased fluidization for fixed particle and sCO 2 inlet conditions because higher h T,w due to fluidization is offset by increased axial dispersion, which suppresses temperature differences between the particles and sCO 2 in the counterflow configuration. The axial dispersion reduces the effective overall heat transfer coefficient U based on T p,in to values around 200 W m -2 K -1 .

14 SOLAR ENERGY↗

Solvent-Engineering Method to Deposit Compact Bismuth-Based Thin Films: Mechanism and Application to Photovoltaics

Bismuth-based materials have been studied as alternatives to lead-based perovskite materials for photovoltaic applications. However, poor film quality has limited device performance. Here, we developed a solvent-engineering method and show that it is applicable to several bismuth-based compounds. Through this method, we obtained compact films of methylammonium bismuth iodide (MBI), cesium bismuth iodide (CBI), and formamidinium bismuth iodide (FBI). On the basis of film growth theory and experimental analyses, we propose a possible mechanism of film formation. Additionally, we demonstrate that the resultant compact MBI film is more suitable to fabricate efficient and stable photovoltaic devices compared to baseline MBI films with pinholes. We further employed a new hole-transporting material to reduce the valence-band offset with the MBI. The best-performing photovoltaic device exhibits an open-circuit voltage of 0.85 V, fill factor of 73%, and a power conversion efficiency of 0.71%, the highest reported values for MBI-based photovoltaic devices.

14 SOLAR ENERGY↗