At least 235 records · Page 13

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring, Controlling and Safeguarding Radiochemical Streams at Spent Fuel Reprocessing Facilities with Optical and Gamma-Ray Spectroscopic Methods

The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-useable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MC&A) at these facilities require time-consuming and resourceintensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify offnormal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop and demonstrate the technologies.

controlling↗

Monitoring Radiochemical Processing Streams for the 238 Pu Supply Program with Process Pulse II

Oak Ridge National Laboratory (ORNL) is developing advanced spectroscopic and real-time monitoring capabilities to improve the timeliness of analytical measurements and process decisions for the 238Pu Supply Program. Reducing the time, resources, and costs associated with each production campaign is critical because overlapping campaigns will be required to meet the production goals of the National Aeronautics and Space Administration. Real-time, in situ analytical measurements in the heavily shielded hot cells at the Radiochemical Engineering Development Center (REDC) will allow for rapid process information feedback and operational benefits that help the 238Pu supply program scale-up production efforts. Noteworthy steps were taken during Campaign 5 to establish the ability to monitor processing streams in real time with spectrophotometry and a commercially available online monitoring software called The Unscrambler X Process Pulse II (PP) multivariate statistical process monitoring system by Camo Analytics (version 5.60). PP automates univariate-type calculations within the software itself and executes multivariate models built using The Unscrambler X (version 10.4 or newer). The Unscrambler is a commercially available data analysis software made by the same company. PP is composed of easy-to-use-tools for all personnel, including data scientists and technicians. The software can be used to plot analyte concentration profiles, spectral data, and other process variables in real time. All process data are represented in a single view with interactive charts useful for viewing how a process evolves over time.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Fully Automated Guided Wave System for In-Process Cure Monitoring of CFRP Composite Laminates

A guided wave-based in-process cure monitoring technique for carbon fiber reinforced polymer (CFRP) composites was investigated at NASA Langley Research Center. A key cure transition point (vitrification) was identified and the degree of cure was monitored using metrics such as amplitude and time of arrival (TOA) of guided waves. Using an automated system preliminarily developed in this work, high-temperature piezoelectric transducers were utilized to interrogate a twenty-four ply unidirectional composite panel fabricated from Hexcel (Registered Trademark) IM7/8552 prepreg during cure. It was shown that the amplitude of the guided wave increased sharply around vitrification and the TOA curve possessed an inverse relationship with degree of cure. The work is a first step in demonstrating the feasibility of transitioning the technique to perform in-process cure monitoring in an autoclave, defect detection during cure, and ultimately a closed-loop process control to maximize composite part quality and consistency.

Hudson, Tyler B.↗

Scalable time series change detection for biomass monitoring using gaussian process

Biomass monitoring, specifically detecting changes in the biomass or vegetation of a geographical region, is vital for studying the carbon cycle of the system and has significant implications in the context of understanding climate change and its impacts. Recently, several time series change detection methods have been proposed to identify land cover changes in temporal profiles (time series) of vegetation collected using remote sensing instruments. In this paper, we adapt Gaussian process regression to detect changes in such time series in an online fashion. While Gaussian process (GP) has been widely used as a kernel based learning method for regression and classification, their applicability to massive spatio-temporal data sets, such as remote sensing data, has been limited owing to the high computational costs involved. In this paper we address the scalability aspect of GP based time series change detection. Specifically, we exploit the special structure of the covariance matrix generated for GP analysis to come up with methods that can efficiently estimate the hyper-parameters associated with GP as well as identify changes in the time series while requiring a memory footprint which is linear in the size of input data, as compared to traditional method which involves solving a linear system of equations for the Choleksy decomposition of the quadratic sized covariance matrix. Experimental results show that our proposed method achieves significant speedups, as high as 1000, when processing long time series, while maintaining a small memory footprint. To further improve the computational complexity of the proposed method, we provide a parallel version which can concurrently process multiple input time series using the same set of hyper-parameters. The parallel version exploits the natural parallelization potential of the serial algorithm and is shown to perform significantly better than the serial version, with speedups as high as 10. Finally, we demonstrate the effectiveness of the proposed change detection method in identifying changes in Normalized Difference Vegetation Index (NDVI) data. Moreover, we show that the scalable solution is able to process NDVI data for the entire Iowa region significantly faster than the standard method.

Chandola, Varun↗

Instrumentation complex for Langley Research Center's National Transonic Facility

The instrumentation discussed in the present paper was developed to ensure reliable operation for a 2.5-meter cryogenic high-Reynolds-number fan-driven transonic wind tunnel. It will incorporate four CPU's and associated analog and digital input/output equipment, necessary for acquiring research data, controlling the tunnel parameters, and monitoring the process conditions. Connected in a multipoint distributed network, the CPU's will support data base management and processing; research measurement data acquisition and display; process monitoring; and communication control. The design will allow essential processes to continue, in the case of major hardware failures, by switching input/output equipment to alternate CPU's and by eliminating nonessential functions. It will also permit software modularization by CPU activity and thereby reduce complexity and development time.

Russell, C. H.↗

MONITORING SPENT NUCLEAR FUEL REPROCESSING CONDITIONS NON-DESTRUCTIVELY AND IN NEAR-REAL-TIME USING THE MULTI-ISOTOPE PROCESS (MIP) MONITOR

Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, nondestructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory testing is currently under way and significant results are available. Recent experimental results, along with an overview of the method are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The interplay between vapour, liquid, and solid phases in laser powder bed fusion

The capability of producing complex, high performance metal parts on demand has established laser powder bed fusion (LPBF) as a promising additive manufacturing technology, yet deeper understanding of the laser-material interaction is crucial to exploit the potential of the process. By simultaneous in-situ synchrotron x-ray and schlieren imaging, we probe directly the interconnected fluid dynamics of the vapour jet formed by the laser and the depression it produces in the melt pool. The combined imaging shows the formation of a stable plume over stable surface depressions, which becomes chaotic following transition to a full keyhole. We quantify process instability across several parameter sets by analysing keyhole and plume morphologies, and identify a previously unreported threshold of the energy input required for stable line scans. The effect of the powder layer and its impact on process stability is explored. These high-speed visualisations of the fluid mechanics governing LPBF enable us to identify unfavourable process dynamics associated with unwanted porosity, aiding the design of process windows at higher power and speed, and providing the potential for in-process monitoring of process stability.

36 MATERIALS SCIENCE↗

Stability of Pt/Al 2 O 3 -Based Electrode Langasite SAW Sensors with Al 2 O 3 Capping Layer and Yttria-Stabilized Zirconia Sensing Layer

Surface acoustic wave (SAW) devices have been shown recently to be an appropriate technology for harsh environment sensor applications, such as those in the automotive, aerospace, power plant, and metallurgic industries. Usages include temperature, pressure, torque, strain, gas, liquid, biochemical, and mass sensors in structural health monitoring, industrial process monitoring, environment checking and control, and condition based maintenance. For harsh environment high-temperature applications, battery-free wireless operation associated with sensor robustness, small profile, and mass fabrication capability make SAW sensors a very attractive solution. For high-temperature (< 800°C) gas sensor applications, the stability of SAW sensor platform including protective and sensing film layers must be guaranteed over time and under temperature cycling conditions. This paper reports on the performance and stability of langasite SAW resonator (SAWR) sensor platform using PtAl2O3-based electrode, with atomic layer deposited (ALD) Al2O3 protective layer and yttria-stabilized zirconia (YSZ) gas sensing layer. The effect of 50nm thick Al2O3 or YSZ layers on SAWR sensor resonant frequency and temperature sensitivity responses were investigated. Temperature sensitivities of SAWR sensors with and without ALD Al2O3 protective layer have been compared with numerical predictions for a bare substrate. Measured temperature sensitivities of SAWR sensors with and without the YSZ sensing layers have been compared against each other. In addition, the stability of the SAWR sensor frequency responses have been monitored during multiple 110-hour temperature cycling (over 620 hours in total) from 300°C to 750°C. The measured frequency deviation at 750ºC over six of these 110-hour cycling tests was 0.05%. The results obtained confirm that the presence of the ALD Al2O3 protective layer or the YSZ sensing layer do not compromise the stability of high-temperature harsh environment SAWR sensors, validating their use for the aforementioned applications.

42 ENGINEERING↗

Test chips and ASIC qualification

A test chip set being developed to aid in the qualification of spaceborne Application Specific Integrated Circuits (ASICs) is described. The chip set consists of a process monitor for process parameter verification, a fault chip for yield analysis, a reliability chip for ASIC failure rate analysis, and total ionizing dose and single event upset chips for radiation effect analysis. The test structures contained in these chips are discussed along with representative test results.

Buehler, M. G.↗

Laser Systems

Tunable diode lasers are employed as radiation sources in high resolution infrared spectroscopy to determine spectral characteristics of gaseous compounds. With other laser systems, they are produced by Spectra-Physics, and used to monitor chemical processes, monitor production of quantity halogen lamps, etc. The Laser Analytics Division of Spectra-Physics credits the system's reliability to a program funded by Langley in the 1970s. Company no longer U.S.-owned. 5/22/97

Source record↗

System and process for pulsed multiple reaction monitoring

A new pulsed multiple reaction monitoring process and system are disclosed that uses a pulsed ion injection mode for use in conjunction with triple-quadrupole instruments. The pulsed injection mode approach reduces background ion noise at the detector, increases amplitude of the ion signal, and includes a unity duty cycle that provides a significant sensitivity increase for reliable quantitation of proteins/peptides present at attomole levels in highly complex biological mixtures.

47 OTHER INSTRUMENTATION↗

SPECTROSCOPIC ON-LINE MONITORING FOR PROCESS CONTROL AND SAFEGUARDING OF RADIOCHEMICAL STREAMS

There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the spent nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. In addition, the ability for continuous online monitoring allows for numerous benefits. Our team experimentally assessed the potential of Raman and spectrophotometric techniques for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. Both techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Static spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. This paper summarizes or methodology and results of the U(VI)/nitrate system as a specific example.

separations, PUREX, U, Pu, Np, nitic acid, TBP dod↗

THE MULTI-ISOTOPE PROCESS (MIP) MONITOR: A NEAR-REAL-TIME, NON-DESTRUCTIVE, INDICATOR OF SPENT NUCLEAR FUEL REPROCESSING CONDITIONS

Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, non-destructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory validation is currently under way and significant results are available. The latest experimental results, along with an overview of the method will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safeguards Envelope Progress FY09

The Safeguards Envelope is a strategy to determine a set of specific operating parameters which nuclear facilities may operate within to maximize safeguards effectiveness without sacrificing safety or plant efficiency. This paper details advanced statistical techniques will be applied to real plant process monitoring (PM) data from the Idaho Chemical Processing Plant (ICPP). As a result of the U.S. having no operating nuclear chemical reprocessing plants, there has been a strong interest in obtaining process monitoring data from the ICPP. The ICPP was shut down in 1996 and a recent effort has been made to retrieve the PM data from storage in a data mining effort. In a simulation based on this data, multi-tank and multi-attribute correlations were tested against synthetic diversion scenarios. Kernel regression smoothing was used to fit a curve to the historical data, and multivariable, residual analysis and cumulative sum techniques set parameters for operating conditions. Diversion scenarios were created and tested, showing improved results when compared with a previous study utilizing only one-variable Z- testing7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Power of Priors: Improved Enrichment Safeguards

International safeguards currently rely on material accountancy to verify that declared nuclear material is present and unmodified. Although effective, material accountancy for large bulk facilities can be expensive to implement due to the high precision instrumentation required to meet regulatory targets. Process monitoring has long been considered to improve material accountancy. However, effective integration of process monitoring has been met with mixed results. Given the large successes in other domains, machine learning may present a solution for process monitoring integration. Past work has shown that unsupervised approaches struggle due to measurement error. Although not studied in depth for a safeguards context, supervised approaches often have poor generalization for unseen classes of data (e.g., unseen material loss patterns). This work shows that engineered datasets, when used for training, can improve the generalization of supervised approaches. Further, the underlying models needed to generate these datasets need only accurately model certain high importance features.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗