Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Study of bone mineral metabolism

The use of Sr-85 as an indicator of the skeletal location and relative amount of bone demineralization which occurs during immobilization of the body or body parts, bed-rest or space flight was studied. The bone mineral replacement which occurs after immobilization was measured rather than the bone loss which occurs during immobilization. In a study with two adult beagle dogs, the Sr-85 uptake in a leg which had been immobilized for two months was 400 percent higher than the uptake in the legs in regular use. This increased uptake probably resulted from only a few percent loss in bone mineral and indicates that losses less than one percent can be easily detected and located. The sensitivity, simplicity, and low radiation dose associated with the use of this method indicates that it should receive consideration for use on humans in bed-rest and space flight studies. Methods for measuring changes in total body nitrogen and in assisting the Johnson Space Center in calibrating a whole body counter for total body potassium measurements were also investigated.

Palmer, H. E.↗

Prediction of the noise from a propeller at angle of attack

An analysis is presented to predict the noise of a propeller at angle of attack. The analysis is an extension of that reported by Mani (1990) which predicted the change in noise due to angle of attack due to both unsteady loading and to azimuthal variation of the radiation efficiency of steady noise sources. Mani's analysis, however, was limited to small angles of attack. The analysis reported herein removes this small angle limitation. Results from the analysis are compared with the data of Woodward (1987, 1988), for a single rotation propeller and for a counter rotating propeller. The comparison shows that including the effect of angle of attack on the steady noise sources significantly improves the agreement with data. Including higher order effects of angle of attack, while changing the predicted noise at far forward and aft angles, has little effect near the propeller plane.

Krejsa, Eugene A.↗

Depth dependence of absorbed dose, dose equivalent and linear energy transfer spectra of galactic and trapped particles in polyethylene and comparison with calculations of models

A matched set of five tissue-equivalent proportional counters (TEPCs), embedded at the centers of 0 (bare), 3, 5, 8 and 12-inch-diameter polyethylene spheres, were flown on the Shuttle flight STS-81 (inclination 51.65 degrees, altitude approximately 400 km). The data obtained were separated into contributions from trapped protons and galactic cosmic radiation (GCR). From the measured linear energy transfer (LET) spectra, the absorbed dose and dose-equivalent rates were calculated. The results were compared to calculations made with the radiation transport model HZETRN/NUCFRG2, using the GCR free-space spectra, orbit-averaged geomagnetic transmission function and Shuttle shielding distributions. The comparison shows that the model fits the dose rates to a root mean square (rms) error of 5%, and dose-equivalent rates to an rms error of 10%. Fairly good agreement between the LET spectra was found; however, differences are seen at both low and high LET. These differences can be understood as due to the combined effects of chord-length variation and detector response function. These results rule out a number of radiation transport/nuclear fragmentation models. Similar comparisons of trapped-proton dose rates were made between calculations made with the proton transport model BRYNTRN using the AP-8 MIN trapped-proton model and Shuttle shielding distributions. The predictions of absorbed dose and dose-equivalent rates are fairly good. However, the prediction of the LET spectra below approximately 30 keV/microm shows the need to improve the AP-8 model. These results have strong implications for shielding requirements for an interplanetary manned mission.

Flight Experiment↗

Decay rate of the second radiation belt

Variations in the Earth's trapped (Van Allen) belts produced by solar flare particle events are not well understood. Few observations of increases in particle populations have been reported. This is particularly true for effects in low Earth orbit, where manned spaceflights are conducted. This paper reports the existence of a second proton belt and it's subsequent decay as measured by a tissue-equivalent proportional counter and a particle spectrometer on five Space Shuttle flights covering an eighteen-month period. The creation of this second belt is attributed to the injection of particles from a solar particle event which occurred at 2246 UT, March 22, 1991. Comparisons with observations onboard the Russian Mir space station and other unmanned satellites are made. Shuttle measurements and data from other spacecraft are used to determine that the e-folding time of the peak of the second proton belt. It was ten months. Proton populations in the second belt returned to values of quiescent times within eighteen months. The increase in absorbed dose attributed to protons in the second belt was approximately 20%. Passive dosimeter measurements were in good agreement with this value.

Badhwar, G. D.↗

Investigation of the NOAA N' S Search and Rescue Antenna Inadvertent Deployment: Type C Mishap

The NOAA N' Search and Rescue Antenna (SRA) inadvertently deployed during a spacecraft rotation on April 14,2007. This rotation was part of a normal operation to configure the spacecraft for additional antenna and the solar array boom deployments. This procedure (red flag written) had been modified to look for a lost metal washer and a thermal blanket button. The modification to the procedure was reviewed and approved by the Lockheed Martin Missiles and Space (LMMS) Material Review Board (MRB) per standard procedures. The flag to the procedure introduced a counter clockwise rotation before the normal clockwise rotation. The antenna was temporally stowed and held in place via lacing cord. The lacing cord broke and allowed the SRA to inadvertently deploy during the clockwise rotation. The SRA broke through a hard stop bracket and damaged an instrument optical sensor radiator panel. The satellite damage appears to be minimal and there were no injuries to personnel. The damage to the Advanced Microwave Sounding Unit (AMSU)-A1 instrument has not been fully assessed. Based on mishap site visits, interviews and data analysis, the Mishap Investigation Team (MIT) identified the underlying causes of the mishap. Event and causal factor tree diagrams were developed, resulting in the identification of the proximate (or direct) cause and root causes of the mishap.

Sabelhaus, Phil↗

Artemis III Neutron Surface Science

This paper highlights lunar neutron science that can be performed in support of the Artemis 2024 mission within 6 degrees of the lunar south pole. There are two primary science goals: the characterization of the radiation environment, and secondly, inference of regolith composition including the presence of water. Characterizing the surface radiation environment is important for risk identification and mitigation during crewed lunar missions. The lunar surface radiation environment includes a unique neutron contribution. The relative contribution from neutrons is higher outside the shielding effects of Earth’s magnetic field, which the Moon experiences ~25% of its orbit. To evaluate the radiation risk to astronauts at the lunar surface, fast neutron measurements are needed. Neutrons are generated when galactic cosmic rays (GCR) collide with the lunar regolith and provide valuable elemental composition information about the near surface (< 1m). For the characterization of regolith composition, a low energy neutron spectrometer or counter can determine surface composition. This provides ground truth for orbital neutron data from the Lunar Reconnaissance Orbiter and Lunar Prospector missions.

Lunar science, Moon, geology, geophysics, neutron ↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Radiative pion capture by C12.

The energy spectrum of neutrons from radiative pion capture by carbon is investigated. Radiative pion capture is identified by coincidence of a stop signal and a signal from one of six lead-glass gamma detectors when negative pions traverse a beam telescope and are stopped in a carbon target. The energy of the neutrons is measured using the time interval between a stop signal coincident with a gamma-counter signal and a signal from a liquid-oscillator neutron counter. Asymmetry in the neutron-photon angular correlation increases with neutron energy and is accounted for by direct neutron emission.

Lam, W. C.↗

The search for absorption of 1 keV X-rays by the Small Magellanic Cloud

The contribution of the extragalactic component of the diffuse background to the 1 keV energy band remains unknown. An effective way to ascertain this contribution is to measure the absorption of the extragalactic component by the neutral hydrogen in the Small Magellanic Cloud (SMC) with an instrument capable of eliminating point sources from the X-ray data that compensate for absorption. The image proportional counter data from the Einstein observatory can be used for this purpose. Additionally, any extended emission must also be eliminated. The resulting source free data can be compared to the neutral hydrogen and the amount of absorption can then be obtained when compared to the diffuse flux away from the SMC. However, due to other types of radiation contaminating the X-ray data, a true measure of the X-ray absorption was not obtained.

Marazas, Brad↗

Background Simulation of the MSFC GSPC Balloon Payload

Numerical simulations are used to predict the cosmic-ray induced background in a passively shielded gas scintillation proportional counter to be used as the focal plane instrument of a balloon-borne hard x-ray telescope system. The predicted background in the 20-75 keV operating range of the detector shows a spectral shape characteristic of a power law photoelectrically absorbed by the stainless steel pressure vessel walls. It is found that the dominant background radiation component is simply cosmic diffuse and atmospheric gamma-ray leakage though there is a contribution from nuclear interactions of energetic particles in the walls and nearby payload structures. The correlation between shielding properties and background flux is examined parametrically using one-dimensional slab models, within material and weight constraints, in order to optimize predicted sensitivity. The addition of a few mm thick Sn passive shielding reduces the primary photon contribution by up to 50% at the spectral peak, E 150 keV, and adds only negligibly to the flux due to photon production within the high-Z shields at lower energies.

Swartz, D. A.↗

Background estimation in a (gnu e)-diffusion detector

Background conditions for detecting (gamma e)-diffusion are discussed with reference to the utilization of a hodoscope system consisting of wide area flat Geiger counters connected for coincidence and of a controllable spark chamber. When calculating the background, any organic compounds synthesized from C, O2 and H2 with radioactive admixtures is presumed to be the preferrable material for the construction of the detector. The number of background events simulating the effect sought is estimated by analyzing the spectrum of the organic glass gamma radiation caused by disintegration and fission of long lived isotopes and by nuclear reactions with the participation of alpha particles and neutrons.

Glotov, V. I.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Initial Results from the Radiation Dosimetry Experiment (RaD-X) Balloon Flight Mission

The NASA Radiation Dosimetry Experiment (RaD-X) high-altitude balloon mission was successfully launched from Fort Sumner, New Mexico USA on 25 September, 2015. Over 15 hours of science data were obtained from four dosimeters at altitudes above about 25 km. The four dosimeters flown on the RaD-X science payload are a Hawk version 3.0 Tissue Equivalent Proportional Counter (TEPC) manufactured by Far West Technologies, a Liulin dosimeter-spectrometer produced by the Solar Research and Technology Institute, Bulgarian Academy of Sciences, a total ionizing dose detector manufactured by Teledyne Microelectronic Technologies, and the RaySure detector provided by the University of Surrey.

Mertens, Christopher J.↗

Intensity of primary cosmic-ray electrons of energy exceeding 8 GeV

Results are reported for measurement of the intensity and energy spectrum of primary cosmic-ray electrons with a spark-chamber-counter-emulsion detector flown at a mean altitude of 3 g/sq cm residual atmosphere. A least-squares fit to the flight data yields an electron spectrum from 8 to 80 GeV of approximately 93E to the -2.91 power electrons/sq m/sec per sr/GeV. The results are compared with those of previous experiments as well as with the spectrum obtained for galactic nonthermal radiation. It is concluded that a 'clumpy' magnetic field proportional to the square root of matter density is consistent with measurements of high-energy electrons and synchrotron radiation toward the center of the Galaxy, that a gradual steepening of the electron spectrum relative to the proton spectrum is consistent with an electron lifetime of 1 million years, and that the density of cosmic-ray nucleons and electrons should be essentially uniform throughout the Galaxy if the nucleons have the same lifetime as the electrons and if they traversed 4 to 5 g/sq cm in that lifetime.

Freier, P.↗

Heat transfer from an internal combustion (Otto-cycle) engine on the surface of Mars

The cooling requirements for an average car sized engine (spark-ignition, V-6, four-stroke, naturally aspirated, about 200 kg, about 100 kW) were looked at for Mars. Several modes of cooling were considered, including forced convection, exhaust, radiation and closed loop systems. The primary goal was to determine the effect of the thinner Martian atmosphere on the cooling system. The results show that there was only a 6-percent difference in the cooling requirements. This difference was due mostly to the thinner atmosphere during forced convection and the heat capacity of the exhaust. A method using a single pass counter-flow heat exchanger is suggested to offset this difference in cooling requirements.

Gwynne, Owen↗

Measurement of the Abundance of Radioactive Be-10 and Other Light Isotopes in Cosmic Radiation Up to 2 GeV /Nucleon with the Balloon-Borne Instrument Isomax

The Isotope Magnet Experiment (ISOMAX), a balloon-borne superconducting magnet spectrometer, was designed to measure the isotopic composition of the light isotopes (3 les than or = Z less than or = 8) of cosmic radiation up to 4 GeV/nucleon with a mass resolution of better than 0.25 amu by using the velocity versus rigidity technique. To achieve this stringent mass resolution, ISOMAX was composed of three major detector systems: a magnetic rigidity spectrometer with a precision drift chamber tracker in conjunction with a three-layer time-of-flight system, and two silica-aerogel Cerenkov counters for velocity determination. A special emphasis of the ISOMAX program was the accurate measurement of radioactive Be-10 with respect to its stable neighbor isotope Be-9, which provides important constraints on the age of cosmic rays in the Galaxy. ISOMAX had its first balloon flight on 1998 August 4-5 from Lynn Lake, Manitoba, Canada. Thirteen hours of data were recorded during this flight at a residual atmosphere of less than 5 g/sq cm. The isotopic ratio at the top of the atmosphere for Be-10/Be-9 was measured to be 0.195 +/- 0.036 (statistical) +/- 0.039 (systematic) between 0.26 and 1.03 GeV/nucleon and 0.317 +/- 0.109(statistical) +/- 0.042(systematic) between 1.13 and 2.03 GeV/nucleon. This is the first measurement of its kind above l GeV/nucleon. ISOMAX results tend to be higher than predictions from current propagation models. In addition to the beryllium results, we report the isotopic ratios of neighboring lithium and boron in the energy range of the time-of-flight system (up to approx. 1 GeV/nucleon). The lithium and boron ratios agree well with existing data and model predictions at similar energies.

Hams, T.↗