Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation↗

Construction of a Cosmic Ray Telescope for the hpDIRC Radiators at the Electron Ion Collider

Nuclear physics pertains to the understanding of the structure and dynamics of the nuclei of atoms, accounting for almost all of the visible matter in the universe. The future Electron-Ion Collider (EIC) will play a crucial role in discovering new laws of Nuclear physics. A pivotal aspect of the EIC is exceptional particle identification (PID). Identifying charged hadrons in their final state can be done with special types of Cherenkov Detectors. One type of detector utilizes the Detection of Internally Reflected Cherenkov radiation (DIRC) phenomena. Able to provide precise PID separation up to relatively high momenta, DIRC radiators, made of synthetic fused silica, produce Cherenkov radiation when hit by high energy electromagnetically charged particles. In this thesis we present details of the construction of a cosmic ray telescope (CRT) to utilize high energy muons from cosmic rays to test DIRC radiators. These types of radiators will be used for the high-performance DIRC (hpDIRC) to be used in the ePIC detector in the future EIC. We go into detail on the DIRC process and the individual pieces of hardware required to make the CRT. Lots of labor was used for certain parts of the CRT, specifically the construction of a dark box for the DIRC radiators. The CRT construction and implementation of all of its components are planned to be completed before 2025.

Shankman, Nathan↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

OR22-Neuromorphic Rad Detector-PD3Ra (Final Report)

In unattended monitoring scenarios, automated radiation detection algorithms must be able to detect low signal-to-noise ratio (SNR) anomalies in a potentially dynamic and noisy background and report these anomalies in a timely fashion. Dynamic and noisy backgrounds complicate the use of simple gross-counting algorithms because they can lead to either high false positive rates or low sensitivity. Algorithms that use the entire spectrum have been the most successful in this area; notable examples are the NSCRAD algorithm developed at Pacific Northwest National Laboratory and recently the nonnegative matrix factorization approach developed at Lawrence Berkeley National Laboratory (LBNL). These approaches use either spectral regions of interest or spectral decomposition to detect threat isotopes in the background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of η c ( 1 S , 2 S ) and χ c J decays to 2 ( π + π − ) η via ψ ( 3686 ) radiative transitions

Based on ( 2712.4 ± 14.1 ) × 10 6 ψ ( 3686 ) decays collected with the BESIII detector, we have observed, for the first time, the hadronic decays of S- and P-wave charmonium states into 2 ( π + π − ) η via radiative transitions from ψ ( 3686 ) . The branching fraction of the decay η c ( 1 S ) → 2 ( π + π − ) η has a significant dependence on the interference pattern between η c ( 1 S ) and non- η c ( 1 S ) processes. We measure it in both the destructive and constructive interference scenarios for the first time. The mass and width of the η c ( 1 S ) are measured to be M = ( 2984.14 ± 0.13 ± 0.38 ) MeV / c 2 and Γ = ( 28.82 ± 0.11 ± 0.82 ) MeV , respectively. Clear signals for the decays of the χ c J ( J = 0 , 1 , 2 ) and the η c ( 2 S ) to 2 ( π + π − ) η are also observed for the first time, and the corresponding branching fractions are measured. The ratio of the branching fractions between the η c ( 2 S ) and η c ( 1 S ) decays is significantly lower than the theoretical prediction, which might suggest different dynamics in their decays. Published by the American Physical Society 2025

Ablikim, M.↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Independence of the Collins Asymmetry in 𝑝 ↑⁢ 𝑝 Collisions

The STAR experiment reports new, high-precision measurements of the transverse single-spin asymmetries for 𝜋 ± within jets, namely the Collins asymmetries, from transversely polarized 𝑝 ↑⁢ 𝑝 collisions at $\sqrt{s}$ = 510 GeV. The energy-scaled distribution of jet transverse momentum, 𝑥 T = 2⁢𝑝 T, jet /$\sqrt{s}$, shows a remarkable consistency for Collins asymmetries of 𝜋 ± in jets between $\sqrt{s}$ = 200 GeV and 510 GeV. This indicates that the Collins asymmetries are nearly energy independent, with, at most, a very weak scale dependence in 𝑝 ↑ ⁢𝑝 collisions. These results extend to high-momentum scales (𝑄 2 ≤ 3400 GeV 2 ) and enable unique tests of evolution and universality in the transverse-momentum-dependent formalism, thus providing important constraints for the Collins fragmentation functions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗