Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

ELDRS Characterization for a Very High Dose Mission

Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

Radiation Damage↗

ISS Radiation Shielding and Acoustic Simulation Using an Immersive Environment

The International Space Station Environment Simulator (ISSES) is a virtual reality application that uses high-performance computing, graphics, and audio rendering to simulate the radiation and acoustic environments of the International Space Station (ISS). This CAVE application allows the user to maneuver to different locations inside or outside of the ISS and interactively compute and display the radiation dose at a point. The directional dose data is displayed as a color-mapped sphere that indicates the relative levels of radiation from all directions about the center of the sphere. The noise environment is rendered in real time over headphones or speakers and includes non-spatial background noise, such as air-handling equipment, and spatial sounds associated with specific equipment racks, such as compressors or fans. Changes can be made to equipment rack locations that produce changes in both the radiation shielding and system noise. The ISSES application allows for interactive investigation and collaborative trade studies between radiation shielding and noise for crew safety and comfort.

Verhage, Joshua E.↗

Riding the Banzai Pipeline at Jupiter: Balancing Low Delta-V and Low Radiation to Reach Europa

Europa's tantalizing allure as a possible haven for life comes cloaked in a myriad of challenges for robotic spacecraft exploration. Not only are the propulsive requirements high and the solar illumination low, but the radiation environment at Jupiter administers its inexorable death sentence on any electronics dispatched to closely examine the satellite. So to the usual trades of mass, delta-V, and cost, we must add radiation dose, which tugs the trajectory solution in a contrary direction. Previous studies have concluded that adding radiation shielding mass is more efficient than using ?V to reduce the exposure time, but that position was recently challenged by a study focusing on delivering simple landers to the Europa surface. During this work, a new trajectory option was found to occupy a strategic location in the delta-V/radiation continuum - we call it the "Banzai pipeline" due to the visual similarity with the end-on view down a breaking wave, as shown in the following figures.

McElrath, Timothy P.↗

Degradation of optical components in space

This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.

Blue, M. D.↗

Mutation induction in bacteria after heavy ion irradiation

From a compilation of experimental data on the mutagenic effects of heavy ions in bacteria, main conclusions have been drawn as follows: (1) The mutagenic efficacy of heavy ions in bacteria depends on physical and biological variables. Physical variables are the radiation dose, energy and charge of the ion; the biological variables are the bacterial strain, the repair genotype of bacteria, and the endpoint investigated (type of mutation, induction of enzymes related to mutagenesis); (2) The responses on dose or fluence are mainly linear or linear quadratic. The quadratic component, if found for low LET radiation, is gradually reduced with increasing LET; (3) At low values of Z and LET the cross section of mutation induction sigma m (as well as SOS response, sigma sos. and lambda phage induction, sigma lambda versus LET curves can be quite consistently described by a common function which increases up to approximately 100 keV/mu m. For higher LET values, the sigma(m) versus LET curves show the so-called 'hooks' observed also for other endpoints; (4) For light ions (Z is less than or equal to 4), the cross sections mostly decrease with increasing ion energy, which is probably related to the decrease of the specific energy departed by the ion inside the sensitive volume (cell). For ions in the range of Z = 10, sigma(m) is nearly independent on the ion energy. For heavier ions (Z is greater than or equal to 16), sigma(m) increases with the energy up to a maximum or saturation around 10 MeV/u. The increment becomes steeper with increasing atomic number of the ion. It correlates with the increasing track radius of the heavy ion; (5) The mutagenic efficiency per lethal event changes slightly with ion energy, if Z is small indicating a rough correlation between cellular lethality and mutation induction, only. For ions of higher Z this relation increases with energy, indicating a change in the 'mode' of radiation action from 'killing-prone' to 'mutation-prone'; and (6) Repair genotype substantially influences the radiation induced mutagenesis. Different mechanisms of mutation induction and/or different types of biologically significant lesions in wild type cells compared to repair deficient strains are a likely explanation.

Horneck, G.↗

Biological dosimetry by interphase chromosome painting

Both fluorescence in situ hybridization of metaphase spreads with whole-chromosome probes and premature chromosome condensation in interphase nuclei have been used in the past to estimate the radiation dose to lymphocytes. We combined these techniques to evaluate the feasibility of using painted interphase chromosomes for biodosimetry. Human peripheral lymphocytes were exposed to gamma rays and fused to mitotic Chinese hamster cells either immediately after irradiation or after 8 h incubation at 37 degrees C. Interphase or metaphase human chromosomes were hybridized with a composite probe specific for human chromosomes 3 and 4. The dose-response curve for fragment induction immediately after irradiation was linear; these results reflected breakage frequency in the total genome in terms of DNA content per chromosome. At 8 h after irradiation, the dose-response curve for chromosome interchanges, the prevalent aberration in interphase chromosomes, was linear-quadratic and similar to that observed for metaphase chromosomes. These results suggest that painting prematurely condensed chromosomes can be useful for biological dosimetry when blood samples are available shortly after the exposure, or when interphase cells are to be scored instead of mitotic cells.

NASA Discipline Radiation Health↗

1986 Annual Conference on Nuclear and Space Radiation Effects, 23rd, Providence, RI, July 21-23, 1986, Proceedings

The present conference on the effects of nuclear and space radiation on electronic hardware gives attention to topics in the basic mechanisms of radiation effects, dosimetry and energy-dependent effects, electronic device radiation hardness assurance, SOI/SOS radiation effects, spacecraft charging and space radiation, IC radiation effects and hardening, single-event upset (SEU) phenomena and hardening, and EMP/SGEMP/IEMP phenomena. Specific treatments encompass the generation of interface states by ionizing radiation in very thin MOS oxides, the microdosimetry of meson energy deposited on 1-micron sites in Si, total dose radiation and engineering studies, plasma interactions with biased concentrator solar cells, the transient imprint memory effect in MOS memories, mechanisms leading to SEU, and the vaporization and breakdown of thin columns of water.

Ellis, Thomas D.↗

Summary of LET spectra and dose measurements on ten STS missions

A comparison of linear energy transfer (LET) spectra measurements made with plastic nuclear track detectors (PNTD's) from area passive dosimeters (APD's), was made for ten different STS missions under similar shielding. The results show that integral flux, dose rate and equivalent dose rate values follow a general increase with respect to increasing orbital inclination and altitude but that there are large variations from a simple relationship. This is to be expected since it has been shown that Shuttle attitude variations, combined with the anisotropic particle flux at the South Atlantic Anomaly (SAA), can result in differences of a factor of 2 in dose rate inside the Shuttle (Badhwar et al., 1995). Solar cycle and shielding differences also result in variations in radiation dose between STS missions. Spaceflight dosimeters from the STS missions are also being used in the development of a method for increasing LET spectra measurement accuracy by extending LET measurements to particle tracks of ranges 10-80 microns. Refinements in processing and measurement techniques for the flight PNTD's have yielded increased detection efficiencies for the short tracks when LET spectra determined by using the standard and refined methods were intercompared.

Source record↗

Galactic Cosmic-Ray-Produced Thermoluminescence Profiles in Meteorites Lunar Samples and a Terrestrial Analog

The long-term radiation shielding properties of common extraterrestrial materials are poorly known, although these materials are the most likely structural elements on airless worlds such as the Moon. We report on radiation dose profiles in meteorites and lunar soil cores using specific minerals as naturally-occurring "dosimeters". We find that radiation profiles are fairly flat in typical meteoroid bodies (less than 85 cm radius) and drop by only about 40% through about 2.5 m of lunar soil. These profiles are produced by primary galactic cosmic rays and the secondary proton cascade but with a significant contribution by secondary neutrons at depths of about 2 m (300 g/sq cm).

Benoit, Paul H.↗

The Impact on Space Radiation Requirements and Effects on ASIMS

The evolution of highly miniaturized electronic and mechanical systems will be accompanied by new problems and issues regarding the radiation response of these systems in the space environment. In this paper we discuss some of the more prominent radiation problems brought about by miniaturization. For example, autonomous micro-spacecraft will require large amounts of high density memory, most likely in the form of stacked, multichip modules of DRAM's, that must tolerate the radiation environment. However, advanced DRAM's (16 to 256 Mbit) are quite susceptible to radiation, particularly single event effects, and even exhibit new radiation phenomena that were not a problem for older, less dense memory chips. Another important trend in micro-spacecraft electronics is toward the use of low-voltage microelectronic systems that consume less power. However, the reduction in operating voltage also caries with it an increased susceptibility to radiation. In the case of application specific integrated microcircuits (ASIM's), advanced devices of this type, such as high density field programmable gate arrays (FPGA's) exhibit new single event effects (SEE), such as single particle reprogramming of anti-fuse links. New advanced bipolar circuits have been shown recently to degrade more rapidly in the low dose rate space environment than in the typical laboratory total dose radiation test used to qualify such devices. Thus total dose testing of these parts is no longer an appropriately conservative measure to be used for hardness assurance. We also note that the functionality of micromechanical Si-based devices may be altered due to the radiation-induced deposition of charge in the oxide passivation layers.

Barnes, C.↗

Space radiation.

Cosmic, solar flare, trapped radiation and radiation dose investigated to determine design requirements for spacecraft shielding

TRAPPED RADIATION↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Radiation model predictions and validation using LDEF satellite data

Predictions and comparisons with the radiation dose measurements on Long Duration Exposure Facility (LDEF) by thermoluminescent dosimeters were made to evaluate the accuracy of models currently used in defining the ionizing radiation environment for low Earth orbit missions. The calculations include a detailed simulation of the radiation exposure (altitude and solar cycle variations, directional dependence) and shielding effects (three-dimensional LDEF geometry model) so that differences in the predicted and observed doses can be attributed to environment model uncertainties. The LDEF dose data are utilized to assess the accuracy of models describing the trapped proton flux, the trapped proton directionality, and the trapped electron flux.

Armstrong, T. W.↗

Enigmatic Isovaline: Investigating the Stability, Racemization, and Formation of a Non-biological Meteoritic Amino Acid

Among the Murchison meteoritic amino acids, isovaline stands out as being both nonbiological (non-protein) and having a relatively high abundance. While approximately equal amounts of D- and L-isovaline have been reported in Murchison and other CM meteorites, the molecule's structure appears to prohibit its racemization in aqueous solutions. We recently have investigated the low-temperature solid-phase chemistry of both isovaline and valine with an eye toward each molecule's formation, stability, and possible interconversions of D and L enantiomers. Ion-irradiated isovaline- and valinecontaining ices were examined by IR spectroscopy and highly-sensitive liquid chromatography/time-of-flight mass spectral methods to assess both amino acid destruction and racemization. Samples were studied in the presence and in the absence of water-ice, and the destruction of both isovaline and valine was measured as a function of radiation dose. In addition, we have undertaken experiments to synthesize isovaline, valine, and their amino acid isomers by solid-phase radiation-chemical pathways other than the oft-invoked Strecker process. This presentation will review and summarize some of our recent findings. -- Our work has been supported by a grant to the Goddard Center for Astrobiology through the NASA Astrobiology Institute. Experiments were performed in the Cosmic Ice Laboratory (RLH, MHM, AL) and the Astrobiology Analytical Laboratory (JPD, DPG) at the NASA Goddard Space Flight Center.

Hudson, Reggie↗

Total Ionizing Dose Effects on High Resolution (12-/14-bit) Analog-to-Digital Converters

This paper reports total dose radiation test results for high resolution 12-/14-bit A/D converters. Small changes in internal components can cause these devices to fail their specifications at relatively low total dose levels. Degradation of signal-to-noise ratio becomes increasingly importamt for high accuracy converters. Rebound effects in the thick-oxide MOS devices causes these responses to be different at low and high dose rates, which is a major concern for space applications.

radiation ionizing analog-to-digital converters MO↗

Effects of radiation on charge-coupled devices

The effects of 1 MeV electron irradiation upon the performance of two phase, polysilicon aluminum gate CCDs are reported. Both n- and p-surface channel and n-buried channel devices are investigated using 64- and 128-stage line arrays. Characteristics measured as a function of radiation dose include: Transfer inefficiency, threshold voltage, field effect mobility, interface state density, full well signal level and dark current. Surface channel devices are found to degrade considerably at less than 10 to the 5th power rads (Si) due to the large increase in fast interface state density caused by radiation. Buried channel devices maintain efficient operation to the highest dose levels used.

Carnes, J. E.↗

Improvements to the Ionizing Radiation Risk Assessment Program for NASA Astronauts

To perform dosimetry and risk assessment, NASA collects astronaut ionizing radiation exposure data from space flight, medical imaging and therapy, aviation training activities and prior occupational exposure histories. Career risk of exposure induced death (REID) from radiation is limited to 3 percent at a 95 percent confidence level. The Radiation Health Office at Johnson Space Center (JSC) is implementing a program to integrate the gathering, storage, analysis and reporting of astronaut ionizing radiation dose and risk data and records. This work has several motivations, including more efficient analyses and greater flexibility in testing and adopting new methods for evaluating risks. The foundation for these improvements is a set of software tools called the Astronaut Radiation Exposure Analysis System (AREAS). AREAS is a series of MATLAB(Registered TradeMark)-based dose and risk analysis modules that interface with an enterprise level SQL Server database by means of a secure web service. It communicates with other JSC medical and space weather databases to maintain data integrity and consistency across systems. AREAS is part of a larger NASA Space Medicine effort, the Mission Medical Integration Strategy, with the goal of collecting accurate, high-quality and detailed astronaut health data, and then securely, timely and reliably presenting it to medical support personnel. The modular approach to the AREAS design accommodates past, current, and future sources of data from active and passive detectors, space radiation transport algorithms, computational phantoms and cancer risk models. Revisions of the cancer risk model, new radiation detection equipment and improved anthropomorphic computational phantoms can be incorporated. Notable hardware updates include the Radiation Environment Monitor (which uses Medipix technology to report real-time, on-board dosimetry measurements), an updated Tissue-Equivalent Proportional Counter, and the Southwest Research Institute Radiation Assessment Detector. Also, the University of Florida hybrid phantoms, which are flexible in morphometry and positioning, are being explored as alternatives to the current NASA computational phantoms.

Semones, E. J.↗

Circulating miRNA Signature Predicts Health Risks Associated with Cancer and Spaceflight

Biological risks associated with space radiation and microgravity are major concerns for long-term space travel. Through a Systems Biology approach, our previous NASA work has shown both TGF signaling pathways and miRNAs have a critical impact on defining health risks with and without space irradiation. We hypothesize that circulating microRNA (miRNA) signatures are driving microvascular disease and muscle degeneration associated with accelerating aging and will be enhanced by exposure to the space environment (radiation and microgravity). We are investigating this hypothesis with both in vivo and in vitro models to test novel antagonist therapies to these miRNA signatures as countermeasures to reduce space radiation-induced health risks. A comprehensive Systems Biology approach is utilized to examine the influence by high atomic number by high (H) atomic number (Z) and energy (E) (HZE) irradiation. To simulate low-dose exposure due to galactic cosmic rays (GCR), we used ions, energy, and doses determined by a NASA consensus formula of 7 different ions to represent GCR (referred to as GCR sim model). To similate high-dose radiation exposure due to solar particle events (SPE), we used a solar particle event (SPE) sim model which gave a total dose of 1Gy protons with energy ranges from 50MeV to 150MeV. C57BL/6 wild-type female mice were utilized for the irradiations with our established simulated microgravity model (hindlimb suspension model) and an in vitro 3D microvasculature tissue model under simulated microgravity (clinostat) conditions was also irradiated. To expand on the circulating miRNA signature determined from our preliminary data, we determined a group of conserved miRNAs which are commonly being regulated in the majority of the organs and tissues throughout the host using our established techniques. MiRNA-sequencing was done on serum (at time of sacrifice), liver, heart, and muscle (soleus muscle) tissue for all radiation groups. Additional validation of the key miRNAs was performed by droplet digital PCR (ddPCR). This revealed a key circulating miRNA signature (consisting of multiple miRNAs) impacting cardiovascular and muscular disease risk. Further in vitro experiments with CRISPR/Cas9 system to knockout the key miRNA signatures, novel self-delivering antagomirs, overexpression of the miRNAs test the functional impact of the miRNA signatures on both microvascular disease and muscle degeneration due to space irradiation. The current work has started to allow the possible development of a novel minimally invasive miRNA based radioprotector to be used as a countermeasure for space radiation. Collectively, understanding of how whole body space radiation impacts microvascular and tissue degeneration through circulating miRNAs will greatly enhance health risk prognostication and provide possible new mechanisms for protection against space radiation. This work is supported by the Translational Research Institute through NASA Cooperative Agreement NNX16AO69A (T-0404) awarded to AB.

Beheshti, Afshin↗