Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOFREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

LAMP Manufacturing Survey (Final Report)

This report presents the results of a market manufacturing survey performed for fabricating radiofrequency quadrupoles (RFQ) and Drift Tube Linear Accelerator (DTL) components needed for the Los Alamos Neutron Science Center (LANSCE) Modernization Project (LAMP). A review on existing RFQs and DTLs with their parameters, a summary of specific capabilities needed to manufacture them, the common issues during the fabrication process, their consequences, and resolutions to these problems is presented in this report. The goal of this study is to identify potential collaborators and companies capable of manufacturing the necessary accelerator equipment, while minimizing cost and schedule risks that could impact the future modernization of the LANSCE facility.

43 PARTICLE ACCELERATORS↗

CHEETAH: Compact High Efficiency Electrically Tunable Amplifier (Final Report)

The goal of this project was to develop a new type of optically triggered, high speed and high power switch for radiofrequency applications with potential to exceed current state-of-the-art power and bandwidth. This device operates under a new operation principle, where discrete packets of charge carriers are generated with defined size. These are then swept out of the device at high enough fields to prevent diffusion and expansion of these packets. Individual pulse widths are determined by the spatial extent of these packets and their drift velocity, which would enable control over both amplitude and frequency by control of the initial packet size, illumination intensity, and applied voltage. This effort demonstrated this new mode of operation, while uncovering a new regime of pulse compression using negative differential mobility (NDM) semiconductors such as GaAs, where the output electrical pulse is substantially shorter than the input optical pulse.

42 ENGINEERING↗

CHEETAH: Compact High Efficiency Electrically Tunable Amplifier (Abbreviated Final Report)

The goal of this project was to develop a new type of optically triggered, high speed and high power switch for radiofrequency applications with potential to exceed current state-of-the-art power and bandwidth. This device operates under a new operation principle, where discrete packets of charge carriers are generated with defined size. These are then swept out of the device at high enough fields to prevent diffusion and expansion of these packets. Individual pulse width are determined by the spatial extent of these packets and their drift velocity, which would enable control over both amplitude and frequency by control of the initial packet size, illumination intensity, and applied voltage. This effort demonstrated this new mode of operation, while uncovering a new regime of pulse compression using negative differential mobility (NDM) semiconductors such as GaAs, where the output electrical pulse is substantially shorter than the input optical pulse.

42 ENGINEERING↗

Improving Nb3Sn Cavity Performance Using Centrifugal Barrel Polishing

Nb3Sn superconducting radiofrequency (SRF) cavities have been an ongoing research topic for many years motivated by the potential for higher accelerating gradients and quality factors compared to niobium SRF cavities. The highest performing Nb3Sn cavities are manufactured using tin vapor-diffusion coating, which creates a Nb3Sn film with a surface roughness of around 100-200 nm. This is thought to be one of the limiting factors for the accelerating gradient of Nb3Sn cavities due to enhancement of magnetic field near sharp surface features. To smooth Nb3Sn SRF cavities, we have developed a mechanical polishing procedure which uses centrifugal barrel polishing to smooth the surface followed by a secondary tin coating step to repair the surface. We show that the accelerating field of a Nb3Sn SRF cavity is improved by applying this procedure. We also investigate the quench mechanism of the polished cavity by utilizing temperature mapping to measure which regions of the cavity e xperience heating during RF operation. We then cut samples from these regions and analyze the film microstructure and chemical composition in 3D using EDS and EBSD measurements together with a focused ion-beam (FIB) tomography technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Low Temperature Nitrogen Baking on Superconducting Radio Frequency Cavities With Different Frequency

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Forged Ingot Niobium Technology for Accelerator Applications and Scientific Frontiers

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge per Micro-Pulse Calculation for Ideal Lujan and WNR beams

A complete redesign of the LANSCE front-end is currently under development for the Los Alamos Modernization Project (LAMP). This includes the replacement of the traditional Cockroft-Walton injection system to the newer radiofrequency quadrupole (RFQ) standard. LANSCE accelerates both H- and H+ beams and therefore requires an unconventional application for RFQ systems. A new facility could consider using an independent RFQ for each beam species. However, with the tight space of the LANSCE injector facility, it would prove difficult to instrument. Our initial studies have shown that a single RFQ could be used. The negatively- and positively-charged direct current (DC) beams are shaped, bunched, and accelerated out of phase to each other, with very little interaction. This would work for all possible H+ beam gates and most H- Beam gates. However, a challenge arises with the Weapons Neutron Research (WNR) beam structure that requires the acceleration of bunched beams at higher charge density per pulse. The Long Bunch Enable Gate (LBEG) used for the Lujan center is the best example of a standard injector beam gate. The beam gate, or Macro-Pulse (MP), is 625-us long, separated by at least 8.3 ms. A chopper is used to dice the MP into 1750 mini-Pulses (mP), which are 290-ns wide. After chopping, the MP contains 100,000 micro-Pulses (uP), which are generated by the linac acceleration structure modulated at 201.25 MHz; that is, the micro-Pulses are separated 5 ns apart from each other. The H+ beam structure will be very similar once a chopper is added to its transport. However, the Multi-Pulse Enable Gate (MPEG) used for WNR is significantly different in structure. In this case, the mP is chopped to be only 35-ns wide. This width is then rotated into a single 201.25 MHz RF bucket using the Low Frequency Buncher (LFB). This is proving difficult for the RFQ design in the LAMP upgrade. We began investigating the amount of current sent to WNR for two reasons. Firstly, we wanted to find a solution to avoid using the Low Frequency Buncher to simplify the LAMP RFQ design. It is simple to inject and accelerate a 35 mA DC beam in the LAMP RFQ (this is done in numerous accelerator facilities). However, injecting a short bunch with a larger current (once compressed to 5 ns to meet the RFQ frequency) may be difficult. Second, we have a technique called PSR2WNR in which we do not employ the Low Frequency Buncher, but rather accumulate 5 LBEG uP (5 ns) in the PSR and deliver the accumulated beam to WNR every 1.8 us. As a result, we could provide to WNR with five accumulated LBEG uPs every shot. The goal here is to create a rapid kicker with a frequency response of 555 kHz. DARHT-II and other accelerator facilities have constructed kickers of this type for other uses, and our engineers consider this technology as feasible.

43 PARTICLE ACCELERATORS↗

Surface properties and RF performance of Vapor Diffused Nb3Sn on Nb after sequential anneals below 1000 °C

Nb3Sn is a next-generation superconducting material that can be used for future superconducting radiofrequency (SRF) accelerator cavities, promising better performance, cost reduction, and higher operating temperature than Nb. The Sn vapor diffusion method is currently the most preferred and successful technique to coat niobium cavi-ties with Nb3Sn. Among post-coating treatments to opti-mize the coating quality, higher temperature annealing without Sn is known to degrade Nb3Sn because of Sn loss. We have investigated Nb3Sn/Nb samples briefly annealed at 800-1000 °C for 10 and 20 minutes to poten-tially improve the surface to enhance the performance of Nb3Sn-coated cavities. Following the sample studies, a coated single-cell cavity was sequentially annealed at 900 °C and tested its performance each time, improving the cavity's quality factor relatively. This paper summarizes the sample studies and discusses the RF test results from sequentially annealed SRF Nb3Sn/Nb cavity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Simulation of the Photoionization of H- Together With the Subsequent Tracking of the Liberated Electrons

The Proton Improvement Plan - II (PIP-II) is a new linear accelerator (LINAC) complex being built at Fermilab. It is based on superconducting radiofrequency cavities and will accelerate H- ions to 800 MeV kinetic energy before injection into the existing Booster ring. Measurements of the profile of the beam along the LINAC must be done by non-intercepting methods due to the superconducting cavities. The method chosen is photoionization of a small number of H- by a focused infrared laser, aka laserwire. The number of ionized electrons is measured as a function of laser position within the H- beam. To aid in the design of the collection mechanism, a simulation was written in MATLAB with input from the commercial electromagnetic simulation, CST. This simulation calculates the number and positions of the liberated electrons and tracks them through the magnetic collection and H- beam fields to the collection point. Results from this simulation for various points along the LINAC will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

LAMP RFQ vane tip macro-based 3D modeling

This report covers the workflow and the demonstration of modeling the radiofrequency quadrupole (RFQ) vane tip geometry in 3D, for the Front End Upgrade of the LANSCE Modernization Project (LAMP). The goal is to develop an automated procedure to generate the 3D model of the LAMP RFQ vane tip geometry, so as to eliminate the need to manually enter the design parameters for each RFQ cell, when building the 3D model. With the developed procedure, the LAMP RFQ design optimization work can be significantly more efficient.

43 PARTICLE ACCELERATORS↗

Final CRADA Report – NFE-21-08693

TAE Technologies is developing a magnetic fusion energy concept known as the beam-driven field-reversed configuration (FRC) with the ultimate goal of developing a reactor for commercial electricity production capable of burning aneutronic pB11 fuel. To achieve the high plasma temperatures this requires, auxiliary radiofrequency (RF) heating will likely be needed. High Harmonic Fast Wave (HHFW) heating has been identified as a candidate RF heating scheme to overcome the unique challenges posed to RF heating by the FRC, including the large distance from the plasma edge to the last closed flux surface and a magnetic field profile with strength decreasing from edge to core and reversing sign at a null point inside the plasma. The purpose of this project was to develop the experimental capabilities to test HHFW on TAE’s C-2W device through the design of a phased array antenna and accompanying matching network. The design was performed by ORNL and informed by experiments with a prototype four-strap phased antenna-array that was manufactured and installed on the LArge Plasma Device (LAPD) at UCLA and simulations conducted with the Petra-M code under the purview of a previous INFUSE grant. The ORNL team completed the conceptual design of the antenna and matching network which was then handed off to the TAE Mechanical Design team. The design was then iterated on to ensure changes to the mechanical design did not interfere with the RF performance. This process is now complete, and, with mechanical design in hand, TAE is proceeding with plans for final integration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decoupling of Nitrogen and Oxygen Impurities in Nitrogen Doped SRF Cavities

The performance of superconducting radiofrequency (SRF) cavities is critical to enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry of niobium samples baked at temperatures varying from 75-800 $^\circ$C with and without nitrogen injection. From these results, we developed treatments recipe that decouple the effects of oxygen and nitrogen in doping treatments. Understanding how these impurities and their underlying mechanisms drive further optimization in the tailoring of impurity profiles for high-performance SRF cavities.

43 PARTICLE ACCELERATORS↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Criteria for Determining the Safety of Wireless Technologies at Nuclear Power Plants

This report provides an initial discussion of the potential impact to safety-related/important-to-safety (SR/ITS) systems by the possible expanded use of wireless technologies. One aspect of this discussion is focused on a review of Regulatory Guide (RG) 1.180 Rev. 2 to determine whether any revisions are necessary to reflect the current state of practice in evaluating and protecting instrumentation and control (I&C) systems and components from electromagnetic interference (EMI) or radiofrequency interference (RFI) on safety and nonsafety I&C. Electromagnetic compatibility (EMC) is the ability of a device or system to function satisfactorily in its electromagnetic (EM) environment, which is achieved by limiting the unintentional generation, propagation, and reception of EM energy that may cause unwanted effects such as EMI. The goal of EMC is to ensure the correct operation of different types of equipment in a common EM environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of the Surface Morphology and Chemical Composition of Zr-Nb3Sn Alloys with Zr Different Concentrations

The inclusion of zirconium (Zr) in niobium-tin (Nb3Sn) significantly enhances the performance of Nb3Sn radiofrequency cavities in high magnetic fields. This research project is dedicated to characterizing the surface properties and chemical composition of Zr-doped Nb3Sn. Two different concentrations of Zr were used for doping: approximately 0.5% and 24%. Various spectroscopy techniques were employed to analyze how the surface morphology and chemical composition of Nb3Sn change with increasing Zr content. The findings of this study indicate that the grain size decreases as the Zr concentration increases. In samples with 24% Zr, nanometer-sized particles, likely oxides, were observed. X-ray photoelectron spectroscopy (XPS) data revealed that the thickness of niobium oxides (NbOx) decreases with increasing Zr, while the thickness of tin oxides (SnOx) increases. Additionally, grain size distribution analysis showed that the average grain size is around 5300 nm , with a grain area density of about 165 grains/μm .

Sue, Micah↗