Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFLEXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spatial orientation perception and reflexive eye movements--a perspective, an overview, and some clinical implications

When head motion includes a linear velocity component, eye velocity required to track an earth-fixed target depends upon: a) angular and linear head velocity, b) target distance, and c) direction of gaze relative to the motion trajectory. Recent research indicates that eye movements (LVOR), presumably otolith-mediated, partially compensate for linear velocity in small head excursions on small devices. Canal-mediated eye velocity (AVOR), otolith-mediated eye velocity (LVOR), and Ocular Torsion (OT) can be measured, one by one, on small devices. However, response dynamics that depend upon the ratio of linear to angular velocity in the motion trajectory and on subject orientation relative to the trajectory are present in a centrifuge paradigm. With this paradigm, two 3-min runs yields measures of: LVOR differentially modulated by different subject orientations in the two runs; OT dynamics in four conditions; two directions of "steady-state" OT, and two directions of AVOR. Efficient assessment of the dynamics (and of the underlying central integrative processes) may require a centrifuge radius of 1.0 meters or more. Clinical assessment of the spatial orientation system should include evaluation of central integrative processes that determine the dynamics of these responses.

Review, Tutorial↗

A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

NASA Discipline Number 14-10↗

Reflexive Neurodynamics

Behavioral dynamics of living species is characterized by additional non-Newtonian properties which are not included in the laws of Newtonian or statistical mechanics.

Neurodynamics attractors↗

Lightweight device to stimulate and monitor human vestibulo-ocular reflex

A helmet formed of a rigid shell is disclosed. The shell is lined with several air filled bladders to contact firmly the head of a user. The shell has a rigid chin bar supporting a bite bar connected fixedly to a mouthpiece bearing against the teeth and hard palate to firmly anchor the helmet without movement. The outer shell surface supports various air pumping bulbs and accelerometers. Separate left and right visor pivot on the side guided in a central tongue and groove track to move optical lens mounts into the user's field of vision. The chin bar is connected to the shell by a pair of releasable clasps. A safety lanyard connects to the clasps to quickly pull pins from the clasps to enable quick release in case of motion sickness.

McStravick, M. Catherine↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

Vestibular activation of sympathetic nerve activity

AIM: The vestibulosympathetic reflex refers to sympathetic nerve activation by the vestibular system. Animal studies indicate that the vestibular system assists in blood pressure regulation during orthostasis. Although human studies clearly demonstrate activation of muscle sympathetic nerve activity (MSNA) during engagement of the otolith organs, the role of the vestibulosympathetic reflex in maintaining blood pressure during orthostasis is not well-established. Examination of the vestibulosympathetic reflex with other cardiovascular reflexes indicates that it is a powerful and independent reflex. Ageing, which is associated with an increased risk for orthostatic hypotension, attenuates the vestibulosympathetic reflex. The attenuated reflex is associated with a reduction in arterial pressure. CONCLUSION: These findings suggest that the vestibulosympathetic reflex assists in blood pressure regulation in humans, but future studies examining this reflex in other orthostatically intolerant populations are necessary to address this hypothesis.

Review↗

Use of a radial self-field diode geometry for intense pulsed ion beam generation at 6 MeV on Hermes III

We investigate the generation of intense pulsed focused ion beams at the 6 MeV level using an inductive voltage adder (IVA) pulsed-power generator, which employs a magnetically insulated transmission line (MITL). Such IVA machines typical run at an impedance of few tens of Ohms. Previous successful intense ion beam generation experiments have often featured an “axial” pinch-reflex ion diode (i.e., with an axial anode-cathode gap) and operated on a conventional Marx generator/water line driver with an impedance of a few Ohms and no need for an MITL. The goals of these experiments are to develop a pinch-reflex ion diode geometry that has an impedance to efficiently match to an IVA, produces a reasonably high ion current fraction, captures the vacuum electron current flowing forward in the MITL, and focuses the resulting ion beam to small spot size. A new “radial” pinch-reflex ion diode (i.e., with a radial anode-cathode gap) is found to best demonstrate these properties. Operation in both positive and negative polarities was undertaken, although the negative polarity experiments are emphasized. Particle-in-cell (PIC) simulations are consistent with experimental results indicating that, for diode impedances less than the self-limited impedance of the MITL, almost all of the forward-going IVA vacuum electron flow current is incorporated into the diode current. PIC results also provide understanding of the diode-impedance and ion-focusing properties of the diode. In addition, a substantial high-energy ion population is also identified propagating in the “reverse” direction, i.e., from the back side of the anode foil in the electron beam dump.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reinterpretation of otolith input as a primary factor in space motion sickness

It is hypothesized that exposure to prolonged free fall is a form of sensory/motor rearrangement rather than a direct change in otolith sensitivity or sensory compensation for a reduced otolith input. The rearrangement of stimuli will force a new interpretation by the CNS of otolith input. This reinterpretation is necessary for a structured and meaningful interaction with the new environment. Data from two flight experiments are presented which support an otolith reinterpretation hypothesis. The first experiment measured vestibulo-spinal reflex changes as a function of sustained free fall. Findings indicate that when a monosynaptic reflex (H-reflex), measured from the major postural muscles (soleus), is used adaptation to space flight includes a change in how the CNS interprets a fall. In a normal gravity environment a sudden unexpected fall will produce a potentiated H reflex. After seven days in flight an equivalent fall does not potentiate the reflex. During postflight a greatly increased reflex is observed in those crewmen most susceptible to space motion sickness. In the second experiment self motion perception and torsional eyemovements were modified as a function of exposure to sustained free fall. Preflight roll motion (about the X axis) was perceived as pure roll, and the eye movements recorded were countertorsional. Postflight, roll stimulation was perceived as linear translation (side to side movement) with a small angular motion component. Eye movement measurements confirmed significantly more horizontal motion.

Reschke, M. F.↗

Ocular Counter-Rolling During Centrifugation and Static Tilt

Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1.1 degree of OCR, which was a small but significant decrease in OCR magnitude. The postflight OCR was 5.9 plus or minus 1.4 degree, which was not significantly different from preflight values. During both 0.5-G and one-G centrifugation in microgravity, where the head vertical gravitational component was absent, the OCR magnitude was not significantly different from that produced by an equivalent acceleration during static tilt on Earth. This suggests that the larger OCR magnitude observed during centrifugation on Earth was due to the larger body vertical linear acceleration component, which may have activated either the otoliths or the body tilt receptors. In contrast to previous studies, there was no decrease in OCR gain postflight. Our findings raise the possibility that inflight exposure to artificial gravity, in the form of intermittent one-G and 0.5-G centripetal acceleration, may have been a countermeasure to deconditioning of otolith-based orientation reflexes.

Cohen, Bernard↗

Sensory processing in the vestibular nuclei during active head movements

Many secondary vestibular neurons are sensitive to head on trunk rotation during reflex-induced and voluntary head movements. During passive whole body rotation the interaction of head on trunk signals related to the vestibulo-collic reflex with vestibular signals increases the rotational gain of many secondary vestibular neurons, including many that project to the spinal cord. In some units, the sensitivity to head on trunk and vestibular input is matched and the resulting interaction produces an output that is related to the trunk velocity in space. In other units the head on trunk inputs are stronger and the resulting interaction produces an output that is larger during the reflex. During voluntary head movements, inputs related to head on trunk movement combine destructively with vestibular signals, and often cancel the sensory reafferent consequences of self-generated movements. Cancellation of sensory vestibular signals was observed in all of the antidromically identified secondary vestibulospinal units, even though many of these units were not significantly affected by reflexive head on trunk movements. The results imply that the inputs to vestibular neurons related to head on trunk rotation during reflexive and voluntary movements arise from different sources. We suggest that the relative strength of reflexive head on trunk input to different vestibular neurons might reflect the different functional roles they have in controlling the posture of the neck and body.

Non-NASA Center↗

Role of orientation reference selection in motion sickness

The overall objective of this proposal is to understand the relationship between human orientation control and motion sickness susceptibility. Three areas related to orientation control will be investigated. These three areas are (1) reflexes associated with the control of eye movements and posture, (2) the perception of body rotation and position with respect to gravity, and (3) the strategies used to resolve sensory conflict situations which arise when different sensory systems provide orientation cues which are not consistent with one another or with previous experience. Of particular interest is the possibility that a subject may be able to ignore an inaccurate sensory modality in favor of one or more other sensory modalities which do provide accurate orientation reference information. We refer to this process as sensory selection. This proposal will attempt to quantify subjects' sensory selection abilities and determine if this ability confers some immunity to the development of motion sickness symptoms. Measurements of reflexes, motion perception, sensory selection abilities, and motion sickness susceptibility will concentrate on pitch and roll motions since these seem most relevant to the space motion sickness problem. Vestibulo-ocular (VOR) and oculomotor reflexes will be measured using a unique two-axis rotation device developed in our laboratory over the last seven years. Posture control reflexes will be measured using a movable posture platform capable of independently altering proprioceptive and visual orientation cues. Motion perception will be quantified using closed loop feedback technique developed by Zacharias and Young (Exp Brain Res, 1981). This technique requires a subject to null out motions induced by the experimenter while being exposed to various confounding sensory orientation cues. A subject's sensory selection abilities will be measured by the magnitude and timing of his reactions to changes in sensory environments. Motion sickness susceptibility will be measured by the time required to induce characteristic changes in the pattern of electrogastrogram recordings while exposed to various sensory environments during posture and motion perception tests. The results of this work are relevant to NASA's interest in understanding the etiology of space motion sickness. If any of the reflex, perceptual, or sensory selection abilities of subjects are found to correlate with motion sickness susceptibility, this work may be an important step in suggesting a method of predicting motion sickness susceptibility. If sensory selection can provide a means to avoid sensory conflict, then further work may lead to training programs which could enhance a subject's sensory selection ability and therefore minimize motion sickness susceptibility.

Peterka, Robert J.↗

Vestibulo-Spinal Pathways in Tetrapods: Chapter - 6.26

The vestibulospinal system provides the spinal motor circuits controlling head/neck and limb movements and body posture with rapid reflex adjustments to maintain equilibrium and stability and with a continuous essential excitatory drive, called tonus, to enhance reactive responses to perturbations that force the animal off normal posture. The sensory signals to these reflex circuits originate from hair cells in the inner ear of otolith structures, namely the utricle and saccule, that transduce inertial acceleration and orientation of the head with respect to gravity and in the three orthogonally arranged semicircular canals that transduce angular head rotation. The principal vestibulospinal pathways are 1) the medial vestibulospinal tract that descends in the ventromedial funiculus and innervates inter- and motoneurons located mainly in lamina VII, VIII, and dorsomedial IX throughout the cervical segments; and 2) the lateral vestibulospinal tracts that course in the lateral to ventrolateral funiculi and are distinguished by two divisions: i) a cervical-projecting tract that overlaps many of the targets of medial vestibulospinal tract neurons including the motoneurons in ventromedial IX and also contributes to reflex control of shoulder and forelimb (arm) muscles; and ii) a lumbosacral-projecting tract that provides a rapid input to maintain stable posture and reflex control of the lower body. A striking observation in understanding the functional organization of this sensory-motor system is both that the driving sensory input can be dynamically modified by the behavioral context in which the sensation is made and that it remains able to quickly respond to an external force during self-generated head movements. The structural basis for vestibulospinal inputs to spinal motor control circuits in quadrupeds and bipeds rely in part on the animal's need for coordination between fore- and hind-limb reflex movements. Understanding the sensory-to-motor transformations in the diverse species rely on the correlations of the conserved and unique species behavior, morphology and physiologic function.

Spinal Cord↗

Intravesical ATP instillation induces urinary frequency because of activation of bladder afferent nerves without inflammatory changes in mice: A promising model for overactive bladder

Highlights: • Intravesical ATP instillation induces urinary frequency. • Intravesical ATP instillation activates bladder afferent nerves. • Intravesical ATP instillation do not induce bladder inflammatory changes. • ATP in the bladder lumen is involved in enhancement of the micturition reflex. • Our mouse model of ATP-induced urinary frequency is a promising model of OAB. ATP in the suburothelial layer is released from the bladder urothelium by mechanical stimuli. ATP directly activates purinergic receptors that are expressed on primary bladder afferent neurons and induces the micturition reflex. Although ATP is also released to the bladder lumen from the bladder urothelium, the role of ATP in the bladder lumen is unknown. Recently, clinical studies have reported that urinary ATP levels are much higher in patients with an overactive bladder than healthy controls. These results suggest that ATP in the bladder lumen is also involved in the micturition reflex. In this study, we performed intravesical ATP instillation in the mouse bladder. We evaluated urinary function with novel reliable methods using improved cystometry and ultrasonography, which we previously established. We found that intravesical ATP instillation induced urinary frequency because of activation of bladder afferent nerves without inflammatory changes in the bladder or an increase in post-void residual urine. These results suggest that not only ATP in the suburothelial layer, but also ATP in the bladder lumen, are involved in enhancement of the micturition reflex.

60 APPLIED LIFE SCIENCES↗

New Calabi–Yau manifolds from genetic algorithms

Calabi–Yau manifolds can be obtained as hypersurfaces in toric varieties built from reflexive polytopes. We generate reflexive polytopes in various dimensions using a genetic algorithm. As a proof of principle, we demonstrate that our algorithm reproduces the full set of reflexive polytopes in two and three dimensions, and in four dimensions with a small number of vertices and points. Motivated by this result, we construct five-dimensional reflexive polytopes with the lowest number of vertices and points. By calculating the normal form of the polytopes, we establish that many of these are not in existing datasets and therefore give rise to new Calabi–Yau four-folds. In some instances, the Hodge numbers we compute are new as well.

Astronomy & Astrophysics↗