Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESISTANCE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Tenderness Tester

Space telemetry has been transferred to food processing in the Armour;Tenderorneter, an instrument that predicts the tenderness of meat. The space component of the instrument is a sensitive, highly reliable strain gage originally produced for NASA's Surveyor lunar lander and other space programs by BLH Electronics, Waltham, Mass. Several years ago Armour & Co. began to develop a method of testing a hanging carcass to predict how tender the meat would be after cooking; no such method then existed. After considerable experimentation, Armour came up with a manifold-mounted group of-needle-like probes, which when stuck into a carcass, could measure the degree to which the meat resisted penetration. This provided a basis for predicting tenderness, but the development required one more . step; a device that could translate meat resistance into an electrical readout. Armour found it in the BLH strain gage. The resulting Tenderometer, now a standard and important part of Armour's meat processing operation, includes a large, 10-pronged fork which is plunged into a carcass and a cable-connected, handheld electronic device that translates the sensings of the prongs into a tenderness reading on a dial. The instrument is used by Armour to select and guarantee a premium line of beef known as TesTender, whose annual sales run into tens of millions of pounds.

Source record↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), Results: Eight subjects (2 Active [CEVIS + ARED], 6 Control) have been recruited for this study. Data collection is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Computer modelling of aluminum-gallium arsenide/gallium arsenide multilayer photovoltaics

The modeled cascade cells offer an alternative to conventional series cascade designs that require a monolithic intercell ohmic contact. Selective electrodes provide a simple means of fabricating three-terminal devices, which can be configured in complementary pairs to circumvent the attendant losses and fabrication complexities of intercell ohmic contacts. Moreover, selective electrodes allow incorporation of additional layers in the upper subcell which can improve spectral response and increase radiation tolerance. Realistic simulations of such cells operating under one-sun AMO conditions show that the seven-layer structure is optimum from the standpoint of beginning-of-life efficiency and radiation tolerance. Projected efficiencies exceed 26 percent. Under higher concentration factors, it should be possible to achieve efficiencies beyond 30 percent. However, to simulate operation at high concentration will require a model for resistive losses. Overall, these devices appear to be a promising contender for future space applications.

Wagner, Michael Broderick↗

GaAs VLSI for aerospace electronics

Advanced aerospace electronics systems require high-speed, low-power, radiation-hard, digital components for signal processing, control, and communication applications. GaAs VLSI devices provide a number of advantages over silicon devices including higher carrier velocities, ability to integrate with high performance optical devices, and high-resistivity substrates that provide very short gate delays, good isolation, and tolerance to many forms of radiation. However, III-V technologies also have disadvantages, such as lower yield compared to silicon MOS technology. Achieving very large scale integration (VLSI) is particularly important for fast complex systems. At very short gate delays (less than 100 ps), chip-to-chip interconnects severely degrade circuit clock rates. Complex systems, therefore, benefit greatly when as many gates as possible are placed on a single chip. To fully exploit the advantages of GaAs circuits, attention must be focused on achieving high integration levels by reducing power dissipation, reducing the number of devices per logic function, and providing circuit designs that are more tolerant to process and environmental variations. In addition, adequate noise margin must be maintained to ensure a practical yield.

Larue, G.↗

High Temperature / High Frequency Temperature Measurement: Achieving MHz Response at Temperatures > 1000 Deg-F

High frequency temperature measurements are not possible with current SOA temperature measurement devices at temperatures higher than ~700 deg-F. Temperature measurements above ~1000 deg-F are typical for entry vehicle thermal protection systems (TPS), rocket engines, ram/scramjet engines, etc. A new technology capable of achieving ~1200 deg-F temperature measurements with MHz response has been achieved. Investigations are underway to extend the concept to even higher temperatures. A U.S. patent application is about to be submitted.

High Frequency↗

Microwave and millimeter-wave power generation in silicon carbide (SiC) IMPATT devices

There are two points that should be noted. First, in the thermal resistance calculations it is assumed that the device is operating at 773 K while the results of the room temperature simulations are used. This was done because there is not enough information to correctly predict the material parameters at 773 K. Since, in general, device performance degrades with increasing temperature, the cw results are perhaps a bit optimistic. Second, the electric field in these structures gets extremely high and there might be some possibility of tunneling. This was not incorporated into the simulation. Again, this could result in different device operating conditions.

Mehdi, I.↗

Electronically Controlled Resistor Bank

Resistance quickly varied in small steps over wide range. Device with no moving parts provides variable electrical resistance. Used with analog or digital circuity to provide electronic selection of large number of resistance values for testing, simulation, control, or other purposes. Nearest electromechanical equivalent of all-electronic device is potentiometer driven by servomotor.

Ross, Walter L.↗

Durability tester for FCC connectors

Testing device monitors continuity and resistance of each circuit, it includes springloaded stationary fixture which holds plug, and moving fixture which is driven by small electric motor and is geared to mate and unmate connector 10 times per minute.

Chambers, C. M.↗

Carbon fiber study. A compilation of an intergovernmental committee study

Carbon fibers have opened a wealth of new structural engineering and consumer product opportunities. The potential benefits are higher strength, and lighter weight military and commercial products, which portend energy savings and increases safety. Unfortunately, these benefits are not realized without risk. Inadvertent fiber release, during manufacture or by destruction of the resin binder in fire, is the major hazard associated with composites. The carbon (or graphite) fibers are finer than human hair and if released into the air, they can be easily transported by winds or currents. In contact with electrical devices, they can create resistive loading, short circuits, and arcing, resulting in stoppages or destruction. Their health impact is not fully known and requires careful research and analysis before any firm conclusions can be reached; however, based upon current available information, they are primarily an irritant to the eyes and skin, like fiberglass, rather than carcinogenic or destructive to lung tissue. Major manufacturers are aware of the unique problems associated with these materials and have successfully applied controls to avoid the inplant problems.

Source record↗

Basic mechanisms study for MIS solar cell structures on GaAs

The solar cell structure examined is the MIS configuration on (n) GaAs. The metal room temperature oxide/(n) GaAs materials system was studied. Metals with electronegativities varying from 2.4 (Au) to 1.5 (Al) were used as the upper electrode. The thinnest metallization that did not interfere with the measurement techniques (by introducing essentially transmission line series resistance problems across a device) was used. Photovoltaic response was not optimized.

Fonash, S. J.↗

Isokinetic exercise: A review of the literature

Isokinetic muscle training has all the advantages of isometrics and isotonics while minimizing their deficiencies. By holding the speed of movement constant throughout the full range of motion, isokinetic training devices respond with increased resistance rather than acceleration when the power output of the muscle is increased. Isokinetic training is superior to isometric and isotonic training with respect to increases in strength, specificity of training, desirable changes in motor performance tasks, lack of muscle soreness, and decreases in relative body fat.

Olree, H. D.↗

Thin silicon solar cell performance characteristics

Refined techniques for surface texturizing, back surface field and back surface reflector formation were evaluated for use with shallow junction, single-crystal silicon solar cells. Each process was characterized individually and collectively as a function of device thickness and bulk resistivity. Among the variables measured and reported are open circuit voltage, short circuit current and spectral response. Substantial improvements were obtained by the utilization of a low cost aluminum paste process to simultaneously remove the unwanted n(+) diffused region, form the back surface field and produce an ohmic contact metallization. The highly effective BSF which results from applying this process has allowed fabrication of cells 0.05 mm thick with initial outputs as high as 79.5 mW/4 sq cm (28 C, AM0) and superior electron radiation tolerance. Cells of 0.02 mm to 0.04 mm thickness have been fabricated with power to mass ratios well in excess of 2 watts per gram.

Gay, C. F.↗

Skin friction measuring device for aircraft

A skin friction measuring device for measuring the resistance of an aerodynamic surface to an airstream is described. It was adapted to be mounted on an aircraft and is characterized by a friction plate adapted to be disposed in a flush relationship with the external surface of the aircraft and be displaced in response to skin friction drag. As an airstream is caused to flow over the surface, a potentiometer connected to the plate for providing an electrical output indicates the magnitude of the drag.

Montoya, L. C.↗

Defects and device performance

The necessity for a low-cost crystalline silicon sheet material for photovoltaics has generated a number of alternative crystal growth techniques that would replace Czochralski (Cz) and float-zone (FZ) technologies. Efficiencies of devices fabricated from low resistivity FZ silicon are approaching 20%, and it is highly likely that this value will be superseded in the near future. However, FZ silicon is expensive, and is unlikely ever to be used for photovoltaics. Cz silicon has many of the desirable qualities of FZ except that minority-carrier lifetimes at lower resistivities are significantly less than those of FZ silicon. Even with Cz silicon, it is unlikely that cost goals can be met because of the poor-material yield that results from sawing and other aspects of the crystal rowth. Although other silicon sheet technologies have been investigated, almost all have characteristics that limit efficiency to approx. 16%. In summary, 20% efficient solar cells can likely be fabricated from both FZ and Cz silicon, but costs are likely to be ultimately unacceptable. Alternate silicon technologies are not likely to achieve this goal, but cost per watt figures may be eventually better than either of the single crystal technologies and may rival any thin-film technology.

Storti, G.↗

Design, fabrication, and performance of a whiskerless Schottky diode for millimeter and submillimeter wave applications

Design considerations, fabrication techniques, and performance predictions are presented for a planar whiskerless Schottky diode to be used (in radio astronomy applications) at 100-300 GHz. The anode and ohmic contacts are on the same side of the device, and proton bombardment is used to establish the divided surface (by making some regions of the GaAs wafer semiinsulating) prior to definition of a B-doped SiO2 finger, ohmic contacting, anode formation, and anode contact metallization (all using photolithographic techniques). The contributions of parasitic elements are calculated for a device with a 3.5-micron-deep n(+) layer doped at 2 x 10 to the 18th/cu cm, a 250-nm-thick epitaxial layer doped at 5 x 10 to the 16th/cu cm, and a 1-micron-radius anode (providing zero-bias junction capacitance 7 fE). It is predicted that such a device would have total series resistance 12.58 ohm and total shunt capacitance 1.37 fF, compared with 14.27 ohm and 0.93 fF for the corresponding whiskered device.

Mckinney, K.↗

Inverted thermal conversion - GaAs, a new alternative material for integrated circuits

A new type of GaAs is developed which exhibits inverted thermal conversion (ITC); i.e., it converts from conducting to semiinsulating upon annealing at about 850 C. In device fabrication, its low resistivity prior to high-temperature processing differentiates ITC GaAs from the standard semiinsulating GaAs. The ITC characteristics are obtained through control of the concentration of the midgap donor EL2 based on heat treatment and crystal-growth modification. Thus EL2 does not exist in the conducting state of ITC GaAs. Conversion to the semiinsulating state during 850 C annealing is caused by the formation of EL2.

Lagowski, J.↗