Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dose reconstruction for plutonium-239 intakes at the Rocky Flats Plant

Purpose: The Rocky Flats (RF) Plant was a weapons manufacturing facility that operated from the early 1950s to 1989. Its primary missions were the production of plutonium (Pu) pits for thermonuclear weapons and the processing of retired weapons for Pu recovery. The purpose of this study was to estimate radiation doses to a cohort of 4499 RF workers from an intake of 239 Pu, the primary plutonium isotope handled at the site. Materials and methods: The latest biokinetic models of the International Commission on Radiological Protection, or site-specific variations of those models, were used to estimate 239 Pu intakes for each worker based on model fits to bioassay data often coupled with lung measurements. Results: Urinary excretion and lung retention data for most 239 Pu intakes could be fit reasonably well by a mixture of Pu dioxide and moderately soluble material. For some workers, better fits were obtained by application of other absorption types including Type S, 239 Pu nitrate, or pure 239 Pu dioxide, or by assuming intake via a wound. The lungs typically received the highest tissue doses, with fifty-year committed equivalent doses in the range of 0.5–1 Sv for 275 workers, 1–5 Sv for 115 workers, and greater than 5 Sv for 12 workers. Conclusions: RF was a unique site regarding a large number of lung measurements available for determining the appropriate absorption types for inhaled material. Further, this provided higher confidence in reconstructed 239 Pu doses than is generally gained from urinary data alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of BPM options for the EIC Beam Accumulator Ring

The electron injection system for the Electron-Ion Collider (EIC) at BNL is designed to provide a beam of polarized electrons, which is crucial for studying the structure of protons and atomic nuclei. The Beam Accumulator Ring (BAR) is a part of the injection chain between the 750 MeV linear accelerator and the Rapid Cycling Synchrotron (RCS), which accelerates the beam up to full energy (5–18 GeV). The functional role of the BAR is to accumulate the charge injected from the linear accelerator in order to achieve the high intensity of the polarized electron beam required by the specifications for injection into the RCS. This objective will be realized through the sequential injection of bunches with a charge of 1.1 nC at a repetition rate of 30 Hz. Once the charge of a single bunch reaches 28 nC, the beam will be extracted from the BAR and injected into the RCS. The beam instrumentation needs to provide reliable measurements with the required accuracy over the dynamic range from 0.1 nC (one tenth of a typical injected bunch charge) to 32 nC – the maximum expected accumulated current. There are 10 Beam Position Monitors (BPMs) in the ring, 1 extra button-electrode assembly for the RF system, and 8 BPMs in the beam transport lines. The BPM locations are shown in Fig. 1, marked by blue rectangles. The ring BPMs will be capable of both average orbit and turn-by-turn measurement modes. Accurate measurement of the beam position with a large horizontal offset requires polynomial correction of the BPM nonlinearity.

43 PARTICLE ACCELERATORS↗

Measurement of the LCLS-II dark current using the LDMX Trigger Scintillator Prototype

The Light Dark Matter eXperiment (LDMX) is a proposed fixed-target missing momentum search for sub-GeV thermal relic dark matter. LDMX aims to probe thermal dark matter targets with 1016 electrons on target. Such an approach requires a high-repetition rate, low-current beam, with an average of one electron on target per event. These requirements are well-suited to the DArk Sector Experiments at LCLS-II (DASEL) facility, which will take advantage of the unused RF buckets between LCLS-II bunches to produce a well-defined low-current beam with a 26.9 ns bunch spacing. This document describes the results of a measurement of dark current in the Sector 30 transfer line (S30XL) of the LCLS-II beam, using a prototype of the LDMX trigger scintillator (TS) subsystem.

Berzin, Elizabeth [SLAC]↗

Technical Report for Bayesian Optimization and Reinforcement Learning for Beam Polarization Increase in the BNL Hadron Injectors

This project developed and evaluated physics-informed Bayesian learning and machine learning (ML)-based optimization methods for improving beam polarization preservation in the BNL hadron injector chain. The work focused on uncertainty-aware digital twin modeling, Bayesian calibration of accelerator simulations using beam measurements, and data-efficient optimization strategies including Bayesian optimization and reinforcement learning. These methods were applied to injector tuning and RF control problems in realistic accelerator settings to support improved operational robustness and readiness for RHIC operations and future Electron–Ion Collider facilities. No subject inventions were disclosed under this award.

43 PARTICLE ACCELERATORS↗

Integrated frequency-modulated optical parametric oscillator

Optical frequency combs have revolutionized precision measurement, time-keeping, and molecular spectroscopy. A substantial effort has developed around "microcombs": integrating comb-generating technologies into compact, reliable photonic platforms. Current approaches for generating these microcombs involve either the electro-optic (EO) or Kerr mechanisms. Despite rapid progress, maintaining high efficiency and wide bandwidth remains challenging. Here, we introduce a new class of microcomb -- an integrated optical frequency comb generator that combines electro-optics and parametric amplification to yield a frequency-modulated optical parametric oscillator (FM-OPO). In stark contrast to EO and Kerr combs, the FM-OPO microcomb does not form pulses but maintains operational simplicity and highly efficient pump power utilization with an output resembling a frequency-modulated laser. We outline the working principles of FM-OPO and demonstrate them by fabricating the complete optical system in thin-film lithium niobate (LNOI). We measure pump to comb internal conversion efficiency exceeding 93% (34% out-coupled) over a nearly flat-top spectral distribution spanning approximately 1,000 modes (approximately 6 THz). Compared to an EO comb, the cavity dispersion rather than loss determines the FM-OPO bandwidth, enabling broadband combs with a smaller RF modulation power. The FM-OPO microcomb, with its robust operational dynamics, high efficiency, and large bandwidth, contributes a new approach to the field of microcombs and promises to herald an era of miniaturized precision measurement, and spectroscopy tools to accelerate advancements in metrology, spectroscopy, telecommunications, sensing, and computing.

42 ENGINEERING↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-line installation of the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap

The Cabibbo-Kobayashi-Maskawa quark mixing matrix currently does not satisfy unitarity at the 2σ-level. This could be the result of an inaccurate value of one or both of its largest matrix elements V us and V ud . In the case of V ud , the most precise measurement is obtained from the f t -value measurements of superallowed beta-transitions between 0 + states. The accuracy of this determination can, in turn, be tested by extracting V ud in other transitions including superallowed transitions between mirror nuclei. The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the Nuclear Science Laboratory of the University of Notre Dame to perform such a determination, with the goal of shedding more light on this tension with unitarity. St. Benedict will take a radioactive ion beam produced by TwinSol , thermalize it in a large volume gas catcher, then transport it in two separate differentially-pumped volumes using a radio-frequency (RF) carpet and a radio-frequency quadrupole (RFQ) ion guide before injecting it in an RFQ trap to create cool ion bunches for injection in the measurement Paul trap. In this paper, we detail the installation of the beam preparation components of St. Benedict, and present the results of the first RIBs successfully stopped and extracted from its gas catcher.

Brodeur, M.↗

Addressing qubits with a software-defined radio FPGA (Full Technical Final Report)

Superconducting transmons can be configured as qubits and can also be used for weak signal axion searches. During a prior LDRD (17-ERD-006), a robust capability for system simulation and analysis, algorithm development, algorithm to FPGA workflow and experimental measurements was developed. During that project it was determined that a new software-defined radio FPGA would be a significant improvement in cost, simplicity, and software maintainability over the X6-1000M FPGA plus RF front-end system that had been used. In this Feasibility Study, we successfully developed the interface to the new NI USRP-2954R SDR platform, generated and optimized the VHDL of the existing algorithms, and experimentally tested the new FPGA system on real qubit in the laboratory. These tests showed it had the same SNR on weak measurements as the prior FPGA.

42 ENGINEERING↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

Surface Impedance of Nb$_3$Sn and YBa$_2$Cu$_3$O$_{7-\sigma}$ in High Magnetic Fields

New potential rf applications of superconductors emerged with the need to operate in high dc magnetic fields (up to 16 T) where vortex motion dictates the response: the beam screen coating of the Future Circular Collider (FCC) [1] and haloscopes, i.e. rf cavities for the axions detection [2]. However, very few data are available in the required regimes. We present in this work measurements of the surface impedance Z up to 12 T on bulk Nb₃Sn and YBCO thin films grown by different techniques. The measurements are performed with a dielectric loaded resonator operating at 15 GHz. We obtained the vortex motion resistivity and extracted the high frequency vortex motion parameters [3]: the depinning frequency, the flux-flow resistivity and the pinning constant, as well as their temperature and field dependences. Substantial differences are highlighted in the high frequency pinning properties of the studied materials, providing useful information on possible improvements in view of applications. A comparison with the results obtained in the microwave frequency range at lower fields (up to 1 T) is given.

43 PARTICLE ACCELERATORS↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

Hollow-cathode chemical vapor deposition of thick, low-stress diamond-like carbon films

A radio-frequency (RF), hollow-cathode plasma source with confining magnetic field is described for the chemical vapor deposition of thick ( > 10 µm), amorphous diamond-like carbon ablator films for inertial confinement fusion applications. Plasma is characterized by optical emission spectroscopy, while properties of the resultant films are measured by a combination of profilometry, Rutherford backscattering spectrometry, elastic recoil detection analysis, X-ray diffraction, Raman spectroscopy, and atomic force microscopy. The dependence of the deposition rate, film density, elemental composition, self-bias and residual stress is reported as a function of RF power. Higher density films were found when using Ar plasma, than N 2 or H 2 plasma. The coatings produced are x-ray amorphous, exhibit low compressive stress ( ~ 100 MPa), high density ( < 1.7 g/cm 3 ), hydrogen content of ~ 30 at.%, and a low average roughness of 0.75 nm. Finally, applications of these films as tunable-density ablators for inertial confinement fusion experiments are discussed.

36 MATERIALS SCIENCE↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of plasma in RF jet interacting with water: Thomson scattering versus spectral line broadening

Here, we carry out a detailed characterization of an Ar radiofrequency plasma jet interacting with liquid. The focus of the paper is measurement of the electron density by examining the Stark broadening of hydrogen Balmer α line and Thomson scattering (TS). Supporting diagnostics are done to investigate the channel evolution and movement, and gas temperature. The comparison of the two approaches shows the caveats and the advantages that should gain attention in future applications. In particular, the plasma channel dynamics have a significant impact on the TS signal and may result in physical phenomena being missed due to channel dislocations. The conclusions of the work elucidate the pitfalls for interpreting the results of TS when the discharge is a dynamic filamentary plasma. This work establishes the temporal evolution of the plasma and the gas parameters in a plasma–liquid system employed for investigation of plasma-induced electrodeless electrochemistry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping wall-to-wall fractional cover of Arctic tundra plant functional types in Alaska using 20-m spatial resolution satellite imagery and harmonized plot observations

Estimates of fractional cover (fCover) across given land surfaces are used to assess, and often model, vegetation composition and diversity, which are crucial for understanding the health and functioning of terrestrial ecosystems. Remote sensing provides a useful means for scaling local, plot-measured fCover estimates to regional scales. Leveraging a recently synthesized and harmonized plot database, this study generated wall-to-wall maps of fCover for six Alaskan-Arctic plant functional types (PFT), including non-vascular plants, forbs, graminoids, and deciduous and evergreen shrubs, using 20-m satellite data (Sentinel-1, Sentinel-2, ArcticDEM) using a machine learning regression approach, specifically the random forest (RF) algorithm, which is well-suited for handling nonlinear relationships and high-dimensional satellite datasets. This study additionally addressed the spatio-temporal inconsistencies e.g., sampling scale, plot size, and collection year in plot measured fCover by adopting a multivariate outlier detection approach—Cook’s distance—to identify high-quality plots for model training and validation. Our approach achieves high accuracy (R 2 = 0.59–0.93, root mean squared errors = 0.02–0.10 for all PFTs) between plot-observed and satellite-derived fCover when using high-quality plot samples. The mapped fCover characterizes the spatial patterns of different PFTs across the tundra biome at a 20-m resolution, providing key information needed for improved representation of Arctic tundra vegetation in terrestrial biosphere models to better understand climate-vegetation feedback across the Arctic tundra.

Arctic tundra↗