Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

223 records · Page 13

SU-E-T-279: Realization of Three-Dimensional Conformal Dose Planning in Prostate Brachytherapy

Purpose: Successful clinical treatment in prostate brachytherapy is largely dependent on the effectiveness of pre-surgery dose planning. Conventional dose planning method could hardly arrive at a satisfy result. In this abstract, a three-dimensional conformal localized dose planning method is put forward to ensure the accuracy and effectiveness of pre-implantation dose planning. Methods: Using Monte Carlo method, the pre-calculated 3-D dose map for single source is obtained. As for multiple seeds dose distribution, the maps are combined linearly to acquire the 3-D distribution. The 3-D dose distribution is exhibited in the form of isodose surface together with reconstructed 3-D organs group real-timely. Then it is possible to observe the dose exposure to target volume and normal tissues intuitively, thus achieving maximum dose irradiation to treatment target and minimum healthy tissues damage. In addition, the exfoliation display of different isodose surfaces can be realized applying multi-values contour extraction algorithm based on voxels. The needles could be displayed in the system by tracking the position of the implanted seeds in real time to conduct block research in optimizing insertion trajectory. Results: This study extends dose planning from two-dimensional to three-dimensional, realizing the three-dimensional conformal irradiation, which could eliminate the limitations of 2-D images and two-dimensional dose planning. A software platform is developed using VC++ and Visualization Toolkit (VTK) to perform dose planning. The 3-D model reconstruction time is within three seconds (on a Intel Core i5 PC). Block research could be conducted to avoid inaccurate insertion into sensitive organs or internal obstructions. Experiments on eight prostate cancer cases prove that this study could make the dose planning results more reasonable. Conclusion: The three-dimensional conformal dose planning method could improve the rationality of dose planning by safely reducing the large target margin and avoiding dose dead zones for prostate cancer treatment. 1) National Natural Science Foundation of People's Republic of China (No. 51175373); 2) New Century Educational Talents Plan of Chinese Education Ministry (NCET-10-0625); 3) Scientific and Technological Major Project, Tianjin (No. 12ZCDZSY10600)

60 APPLIED LIFE SCIENCES↗

Characterization of a novel two dimensional diode array the ''magic plate'' as a radiation detector for radiation therapy treatment

Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the ''magic plate'' (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. Methods: The prototype MP is an 11 x 11 detector array based on thin (50 {mu}m) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary ''drop-in'' technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Results: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180 deg. Angular dependence was within 3.5% for the gantry angles {+-} 75 deg. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 x 30 cm{sup 2} field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. Conclusions: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with ''drop-in'' packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preclinical Evaluation of Bioabsorbable Polyglycolic Acid Spacer for Particle Therapy

Purpose: To evaluate the efficacy and safety of a polyglycolic acid (PGA) spacer through physical and animal experiments. Methods and Materials: The spacer was produced with surgical suture material made of PGA, forming a 3-dimensional nonwoven fabric. For evaluation or physical experiments, 150-MeV proton or 320-MeV carbon-ion beams were used to generate 60-mm width of spread-out Bragg peak. For animal experiments, the abdomens of C57BL/6 mice, with or without the inserted PGA spacers, were irradiated with 20 Gy of carbon-ion beam (290 MeV) using the spread-out Bragg peak. Body weight changes over time were scored, and radiation damage to the intestine was investigated using hematoxylin and eosin stain. Blood samples were also evaluated 24 days after the irradiation. Long-term thickness retention and safety were evaluated using crab-eating macaques. Results: No chemical or structural changes after 100 Gy of proton or carbon-ion irradiation were observed in the PGA spacer. Water equivalency of the PGA spacer was equal to the water thickness under wet condition. During 24 days' observation after 20 Gy of carbon-ion irradiation, the body weights of mice with the PGA spacer were relatively unchanged, whereas significant weight loss was observed in those mice without the PGA spacer (P<.05). In mice with the PGA spacer, villus and crypt structure were preserved after irradiation. No inflammatory reactions or liver or renal dysfunctions due to placement of the PGA spacer were observed. In the abdomen of crab-eating macaques, thickness of the PGA spacer was maintained 8 weeks after placement. Conclusions: The absorbable PGA spacer had water-equivalent, bio-compatible, and thickness-retaining properties. Although further evaluation is warranted in a clinical setting, the PGA spacer may be effective to stop proton or carbon-ion beams and to separate normal tissues from the radiation field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PIE on Five Irradiated AGR-1 Compacts

Post-irradiation examination (PIE) is in progress on coated particle fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1). PIE has been completed on five compacts at the Oak Ridge National Laboratory (ORNL). Three compacts (Compacts 6-1-1, 4-4-2, and 5-2-3) were examined in the as-irradiated condition and two compacts (Compacts 6-4-3 and 3-3-2) were subjected to safety testing at 1600°C, followed by post-safety testing examination similar to the PIE performed on the as-irradiated compacts. All compacts were subjected to a standard set of analyses that included the following: (1) detection of exposed fission products by Deconsolidation-Leach-Burn-Leach (DLBL), (2) measurement of gamma-emitting fission product inventory using the Irradiated Microsphere Gamma Analyzer (IMGA), and (3) microstructural examination by x-ray tomography and materialography. The equipment and methods used are reported in detail in ORNL/TM-2012/233, AGR-1 Irradiated Compact 6-1-1 PIE Report, and have been summarized in the next section of this report. This report also provides a brief summary of the results of the completed PIE. Preliminary trends are discussed in this report, but final conclusions will require the support of additional data and further analysis. A separate report is being generated for each AGR-1 compact after PIE is complete that describes in detail the examinations performed and fully documents the data obtained. A final AGR-1 PIE summary report will compile all available data and provide a more comprehensive analysis of the AGR-1 fuel performance. In general, it was observed that the tristructural isotropic (TRISO) coated particles remained intact during irradiation and subsequent safety testing to 1600°C. No significant gaseous 85 Kr release was detected during the irradiation or high temperature safety testing, which would be indicative of simultaneous failure of all three outer layers of the TRISO coating. Only three particles with defective SiC layers were detected in the five compacts included in this summary. These particles were detected because they released a significant fraction of their cesium inventory, which was generally well retained. Two particles from Compact 5-2-3 released cesium during irradiation and one particle from Compact 3-3-2 released cesium during safety testing. However, it is evident that some fission products were released through intact SiC during irradiation. Most of these fission products were trapped in the compact matrix, where they could be analyzed by PIE. In terms of fractional release, the main fission products detected outside intact SiC were silver, palladium, and europium. The main impact of irradiation on the microstructure of the TRISO-coating layers was densification and shrinkage of the buffer layer, which often led to buffer fracture and subsequent enhanced swelling of the kernel. Some inner pyrocarbon (IPyC) layers were cracked by the radiation-induced changes in the buffer layer, and on rare occasion these cracks propagated into the SiC. In the two particles that released cesium during irradiation, these SiC cracks penetrated through the entire layer. The particle from Compact 3-3-2 that released cesium was not directly related to irradiation damage. Its SiC layer was determined to be porous as a result of a fabrication defect that occurs when a particle is over-fluidized in the coater, causing it to pick up carbon soot on the surface of the IPyC prior to SiC deposition. This porous SiC layer remained sufficiently intact during irradiation to retain cesium, but finally cracked during high temperature testing. Analysis of fission products remaining in the coated particles showed that the retention of silver varied dramatically from particle-to-particle within each compact. Examination with the IMGA determined that some particles contained a level of 110m Ag equivalent to that calculated to have been generated over the three-year irradiation period, while other particles contained too little to be detected by the gamma analysis. The mechanism for silver release is still being investigated. Attempts to correlate the varied release behavior to obvious radiation-induced changes in the coating layers have not been successful. Scanning electron microscopy (SEM) has provided some evidence that particles with higher silver release also show greater penetration of palladium silicide into the SiC layer, and this should be studied further.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation behavior of high-entropy alloys for advanced reactors. Final report

In the first task, we have demonstrated the radiation damage and the recrystallization behaviors in multicomponent alloys through molecular-dynamics simulations. It is found that by alloying with atoms of different sizes, the atomic-level strain increases, and the propensity of the radiation-induced crystalline to amorphous transition increases as the defects cluster in the cascade body. Recrystallization of the radiation induced supercooled or glass regions show that by tuning the composition and the equilibrium temperature, the multicomponent alloys can be healed. The crystalline-amorphous-crystalline transitions predict the potential high radiation resistance in multicomponent alloys. In the second task, three types of high-entropy alloys (HEAs) were fabricated from AlCoCrFeNi and AlCuCrFeNi quinary alloys. Hardness and reduced contact modulus were measured using nanoindentation tests. Heavy ion irradiation were performed using 10 MeV gold and 5 MeV nickel to study radiation effects. Al 0.5 CrCuFeNi 2 shows phase separation upon the presence of copper. Both hardness and contact modulus exhibit the same trend as increasing the applied load, and it indicates that excessive free volume may alter the growth rate of the plastic zone. The as-cast Al 0.1 CoCrFeNi specimen undergone the hot isostatic pressing (HIP) process and steady cooling rate which mitigate the quenching effect. The swelling behavior was characterized by the atomic force microscopy (AFM), and the swelling rate is approximately 0.02% dpa. Selected area diffraction (SAD) patters show irradiation-induced amorphization throughout the ion projected range. Within the peak damage region, an amorpous ring is observed, and a mixture of amorphous/ crystalline structure at deeper depth is found. The Al 0.3 CoCrFeNi HEAs shows good radiation resistance up to 60 peak dpa. No voids or dislocations are observed. The crystal structures remain face-centered-cubic (FCC) before and after 5 MeV Ni irradiation. Higher dpa might be required to study defects formation mechanisms. In the third task, all the constituent binary and ternary systems of the Al-Co-Cr-Fe-Ni system were thermodynamically modeled within the whole composition range. Comparisons between the calculated phase diagrams and literature data are in good agreement. The multi-component thermodynamic database of the Al-Co-Cr-Fe-Ni system was then obtained via extrapolation. The current Al-Co-Cr-Fe-Ni thermodynamic database enables us to carry out the calculations of phase diagrams, which can be used as useful guidelines to identify the Al-Co-Cr-Fe-Ni HEAs with desirable microstructures. In the fourth task, we discuss how as-cast and homogenized phases can be identified, what phases are usually found in the as-cast and homogenized conditions, and what the thermodynamics and kinetics of phase transformations are in the AlCoCrFeNi HEA. The microstructure and phase composition were studied in as-cast and homogenized conditions. It showed the dendritrical structure in the as-cast condition consisting primarily of a nano-lamellar mixture of A2 [disorder body-centered-cubic (BCC)] and B2 (ordered BCC) phases, in addition to a very small amount of A1 [disorder face-centered-cubic (FCC)] phases. The homogenization heat treatment resulted in an increase in the volume fraction of the A1 phase and formation of a Sigma phase. Tensile properties in as-cast and homogenized conditions are reported at 700 °C. Thermodynamic modeling of non-equilibrium and equilibrium phase diagrams for the AlCoCrFeNi HEA gave good agreement with the experimental observations of the phase contents. The reasons for the improvement of ductility after the heat treatment are discussed.

36 MATERIALS SCIENCE↗

Preliminary Compendium of the Initial Conditions and Evolution of the Fundamental Interactions of SiC with Ag and Pd

Tri-structural isotropic (TRISO) particles are the fuel of choice for very-high temperature reactors. At the core, these spherical particles consist of an inner fuel kernel of UO{sub 2}, UC{sub 2} or a combination of both, which is coated radially outward by successive layers of low density pyrolytic graphite, an inner high density pyrolytic graphite layer, silicon carbide (SiC) and an outer high density pyrolytic graphite layer. SiC is the main diffusion barrier against the release of fission products due to its hardness and high melting point. Irradiation testing of TRISO particles indicates that trace amounts of metallic fission products can damage or potentially escape through the barrier layer. Surrogate experimental studies have previously been performed by various methods seeking to shed light on and explain the diffusion behavior of Ag and Pd. Although some of these experiments have yielded realistic diffusion coefficients the discrepancy of results between different groups is such that the essential details of the diffusive behavior are still to be fully understood. This work aims to understand the fundamental physical and chemical interactions that take place at the interface of SiC and Ag/Pd, and which give rise to the observed diffusion behavior of these metallic species in TRISO particles. Theoretical simulations of the diffusion of Ag through SiC have been exhaustive but typically yield bulk diffusion coefficients that due to the nature of bulk diffusion phenomena (i.e. slow diffusion) the diffusion coefficients are calculated to be orders of magnitude lower than what experimental observations suggest. This in part is due to the difficulty in simulating realistic models that include various polymorphs of SiC, and the dynamical structural transformations that SiC undergoes in the TRISO environment (which are also to be explained). The result is a particularly challenging problem to solve given that the initial conditions of the interactions of Ag and Pd with SiC are difficult to address, both in theoretical models and surrogate experiments. In order to improve these models the approach taken here is to consider fundamental interactions between Ag and SiC that take place in short time scales by varying the initial environmental conditions, i.e. annealing temperature and time, initial amounts of the metallic species (M) Ag, Pd in SiC/M/SiC multilayers. This work aims to understand the fundamental physical and chemical interactions that take place at the interface of SiC and Ag/Pd, and which give rise to the observed diffusion behavior of these metallic species in TRISO particles. In order to do so we have synthesized SiC/Ag/SiC and SiC/Pd/SiC multilayers of various thicknesses by PLD and characterized them using SEM/EDS. Initial results show that upon annealing Ag agglomerates and ruptures the SiC layer to be released. In the case of Pd a strong chemical interaction is deduced from the slow interlayer diffusion and limited release. Further studies using photoelectron spectroscopy and RHEED will be carried out in order obtain detailed information on the chemical and physical transitions that undergo upon annealing of these systems. (authors)

36 MATERIALS SCIENCE↗

Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks

Purpose: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. Methods: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat–muscle interface and at the surface of the ribs. At the fat–muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. Results: At the level of the ribs, the temperature rise–energy density proportionality constant was estimated to be 6.0–7.6 °C/(J/mm{sup 2}). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm{sup 2} with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm{sup 2} was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. Conclusions: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.

60 APPLIED LIFE SCIENCES↗