Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Theoretical Model Images and Spectra for Comparison with HESSI and Microwave Observations of Solar Flares

We have computed bremsstrahlung and gyrosynchrotron images and spectra from a model flare loop. Electrons with a power-law energy distribution are continuously injected at the top of a semi-circular magnetic loop. The Fokker-Planck equation is integrated to obtain the steady-state electron distribution throughout the loop. Coulomb scattering and energy losses and magnetic mirroring are included in the model. The resulting electron distributions are used to compute the radiative emissions. Sample images and spectra are presented. We are developing these models for the interpretation of the High Energy Solar Spectroscopic Imager (HESSI) x-ray/gamma ray data and coordinated microwave observations. The Fokker-Planck and radiation codes are available on the Web at http://hesperia.gsfc.nasa.gov/hessi/modelware.htm This work is supported in part by the NASA Sun-Earth Connection Program.

Fisher, Richard R.↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarization images of Comet Halley

Observations from two dates 5 Jan. and 7 Jan. 1986 are presented. The images were obtained with the Durham imaging polarimeter on the 1-m telescope of the Wise Observatory, Israel. The observations were made through a broadband filter centered at 0.67 microns with a 0.17 micron effective bandwidth. This wavelength region should be dominated by continuum radiation. The intensity images cover 46 x 78 arcsecs. The intensity images are shown in logorithmic form and they are analyzed.

Eaton, N.↗

Fluorescence imaging to quantify crop residue cover

Crop residues, the portion of the crop left in the field after harvest, can be an important management factor in controlling soil erosion. Methods to quantify residue cover are needed that are rapid, accurate, and objective. Scenes with known amounts of crop residue were illuminated with long wave ultraviolet (UV) radiation and fluorescence images were recorded with an intensified video camera fitted with a 453 to 488 nm band pass filter. A light colored soil and a dark colored soil were used as background for the weathered soybean stems. Residue cover was determined by counting the proportion of the pixels in the image with fluorescence values greater than a threshold. Soil pixels had the lowest gray levels in the images. The values of the soybean residue pixels spanned nearly the full range of the 8-bit video data. Classification accuracies typically were within 3(absolute units) of measured cover values. Video imaging can provide an intuitive understanding of the fraction of the soil covered by residue.

Daughtry, C. S. T.↗

A Framework for Patient-Centered Pathways of Care for Radiopharmaceutical Therapy: An ASTRO Consensus Document

Radiopharmaceutical therapy (RPT) is an area of projected growth and importance with several agents in clinical use, new agents in late-phase clinical trials, and many others under testing and development. This article proposes a framework for developing pathways of care that can be broadly applied to all RPTs, representing the current status of RPT. It suggests foundational elements for many pathways of care for patients with cancer and concludes with areas in active development and the future horizon for RPT treatment centers. Developing a framework for patient-centered pathways of care is a critical step in establishing RPT as standard therapy for patients with a diverse spectrum of cancers. This expected increase in RPT treatment options will affect a much larger population of patients with complex cancer. It will also require enhanced coordination and collaboration among appropriately qualified personnel with diverse expertise in image acquisition, image interpretation, quantitative imaging, dosimetry calculation, radiation quality assurance and safety as well as oncology care and RPT-induced sequelae and response assessment. The essential role of this evolving RPT care team within multidisciplinary oncology care is a cornerstone of this framework for a patient-centered pathway of care for RPT. Given the status of current RPT practice and the horizon for future applications, this patient-centered pathway of care guidance is timely and should help inform future clinical RPT practice paradigms. A task force was recruited from the Theranostic Working Group of the American Society for Radiation Oncology (ASTRO) in May 2019 with equal representation from the nuclear medicine community. The task force expanded on a framework that was originally conceived by the Working Group for patient-centered care. This framework was developed to incorporate the strengths of both radiation oncologists and nuclear medicine physicians. The manuscript was then developed by the task force and posted on the ASTRO website for a 6-week public comment period ending in July 2020. Comments were adjudicated, and the draft was sent to external organizations for potential endorsement. This document was sent to the ASTRO Board of Directors in October 2020 for approval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Properties of scatterers in the troposphere and lower stratosphere of Uranus based on Voyager imaging data

Scalar and vector radiative transfer and microphysical models are presently constructed from photometrically and geometrically corrected Voyager images of Uranus defining spatially-resolved intensities over a range of phase angles for two latitude bands. The methane ice cloud occupying 1.2-1.3 bar is of 0.7 optical depth at 22.5 deg S, rising to 2.4 at 65 deg S; the volume absorption coefficient of the cloud particles is 50 percent greater at the low latitude than at the high, assuming constant mean cloud particle size. The scattering model also includes photochemically-produced stratospheric hydrocarbon ices in the upper troposphere and stratosphere, as well as an optically thick hydrogen sulfide cloud.

Rages, Kathy↗

Validation of Atmospheric Correction of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Radiance Data Based on Radiative Transfer Modeling

An evaluation of atmospheric correction of AVIRIS data using radiative transfer codes LOWTRAN7 and MODTRAN is presented. The algorithm employed is based on a simple model of radiance L at each wavelength at the sensor that can be written approximately LAV=Lp+Tp, where subscript AV referes to AVIRIS, Lp is the path radiance and Tp is the diffuse + direct transmitted radiance of the atmosphere at AVIRIS.

Infrared Mapping↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-Real Time Cloud Properties and Aircraft Icing Indices from GEO and LEO Satellites

Imagers on many of the current and future operational meteorological satellites in geostationary Earth orbit (GEO) and lower Earth orbit (LEO) have enough spectral channels to derive cloud microphysical properties useful for a variety of applications. The products include cloud amount, phase, optical depth, temperature, height and pressure, thickness, effective particle size, and ice or liquid water path, shortwave albedo, and outgoing longwave radiation for each imager pixel. Because aircraft icing depends on cloud temperature, droplet size, and liquid water content as well as aircraft variables, it is possible to estimate the potential icing conditions from the cloud phase, temperature, effective droplet size, and liquid water path. A prototype icing index is currently being derived over the contiguous USA in near-real time from Geostationary Operational Environmental Satellite (GOES-10 and 12) data on a half-hourly basis and from NOAA- 16 Advanced Very High Resolution (AVHRR) data when available. Because the threshold-based algorithm is sensitive to small errors and differences in satellite imager and icing is complex process, a new probability based icing diagnosis technique is developed from a limited set of pilot reports. The algorithm produces reasonable patterns of icing probability and intensities when compared with independent model and pilot report data. Methods are discussed for improving the technique for incorporation into operational icing products.

Minnis, Patrick↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase Contrast X-ray Imaging of Shuttle Insulating Foam

X-ray radiation has been widely used for imaging applications since Rontgen first discovered X-rays over a century ago. Its large penetration depth makes it ideal for the nondestructive visualization of internal structure of materials or objects unobtainable otherwise. Currently widely used nondestructive evaluation (NDE) tools-X-ray radiography and tomography are absorption-based, and work well in highly absorbing materials where density or composition variations due to internal structure or defects are high enough to be spatially distinguished in terms of absorption contrast. However, in many cases where materials such as insulating foam are light-weight, the conventional absorption-based X-ray methods for NDE become less effective. Indeed, the low-density shuttle insulating foam used for flight mission poses a great challenge to the standard NDE tools in that the absorption contrast arising from internal defects of such a low- density material is either weak or indistinguishable. In this presentation, the latest progress in phase contrast X-ray imaging of internal defects of insulating foam will be presented and discussed, demonstrating new opportunities to solve challenging issues involved in advanced materials development and processing for space exploration.

Hu, Zhengwei↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗