Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cosmological considerations on the diffuse gamma-ray isotropic background

Bignami et al (1979) have recently studied the problem of the origin of the diffuse gamma-ray isotropic radiation. They have concluded that within standard cosmology with Lambda = 0 and p = 0, BL Lacertae objects and Seyfert galaxies can account for most of the diffuse radiation if they have not evolved in time. For QSOs, an evolutionary factor is allowed by the data. From the study of radio data, however, it is known that strong evolutionary effects are expected. The discrepancy cannot be explained by changing the geometry of the universe. Contrary to the case of standard cosmology, it is found that in order to fit the diffuse gamma-ray background, the evolutionary function required is almost identical to the one previously determined from the study of the log N-log S relation.

Canuto, V. M.↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

Human System Drivers for Exploration Missions

Evaluation of DRM4 in terms of the human system includes the ability to meet NASA standards, the inclusion of the human system in the design trade space, preparation for future missions and consideration of a robotic precursor mission. Ensuring both the safety and the performance capability of the human system depends upon satisfying NASA Space Flight Human System Standards.1 These standards in turn drive the development of program-specific requirements for Near-earth Object (NEO) missions. In evaluating DRM4 in terms of these human system standards, the currently existing risk models, technologies and biological countermeasures were used. A summary of this evaluation is provided below in a structure that supports a mission architecture planning activities. 1. Unacceptable Level of Risk The duration of the DRM4 mission leads to an unacceptable level of risk for two aspects of human system health: A. The permissible exposure limit for space flight radiation exposure (a human system standard) would be exceeded by DRM4. B. The risk of visual alterations and abnormally high intracranial pressure would be too high. 1

Kundrot, Craig E.↗

The complete polarization state of Io-related radio storms from Jupiter: A statistical study

We report on the complete polarization state (four Stokes parameters) as a function of both frequency and time, of Io-related radiation from Jupiter as observed with the spectropolarimeter at Nancay, France. Our observations include 37 radio storms, with events of both lefthand (LH) and righthand (RH) elliptical polarization and from all Io-related sources (A,B,C and D), plus two non-Io events. The high degree of circular polarization often observed, particularly for LH emission, is difficult to explain in terms of the standard theory of cyclotron maser radiation. The interpretation of the observations in terms of the locations of the sources in Jupiter's magnetosphere is the subject of a companion paper.

Dulk, G. A.↗

Radiation-Tolerant DC-DC Converters

A document discusses power converters suitable for space use that meet the DSCC MIL-PRF-38534 Appendix G radiation hardness level P classification. A method for qualifying commercially produced electronic parts for DC-DC converters per the Defense Supply Center Columbus (DSCC) radiation hardened assurance requirements was developed. Development and compliance testing of standard hybrid converters suitable for space use were completed for missions with total dose radiation requirements of up to 30 kRad. This innovation provides the same overall performance as standard hybrid converters, but includes assurance of radiation- tolerant design through components and design compliance testing. This availability of design-certified radiation-tolerant converters can significantly reduce total cost and delivery time for power converters for space applications that fit the appropriate DSCC classification (30 kRad).

Skutt, Glenn↗

235-F GoldSim Fate and Transport Model: Uncertainty Quantification

Building 235-F was configured with two missions in mind: Actinide Billet Line (ABL) and the fabrication of Pu-238 oxide for space program applications. ABL produced Np-237 billets for use in SRS reactors, whereas the design process, fabrication, and examination of Pu-238 oxide powder occurred within the following areas, respectively: Plutonium Experimental Facility (PEF), Plutonium Fuel Form (PuFF), and Old Metallography Lab (OML). By 1990 production ceased and by 2006 de-inventory occurred; however, assays have shown significant holdup remains within ABL and PuFF. As a result, 235-F is a Category 2 nuclear facility, with plans to undergo deactivation and decommission (D and D) via In-Situ Disposal (ISD). The purpose of this project is to ensure United States Environmental Protection Agency (USEPA) groundwater radiation maximum contaminant level (MCL) and dosage standards are met during the D and D of 235-F by quantifying uncertainty through probabilistic modeling and evaluation of various ISD alternatives. GoldSim is a dynamic modeling software package with a graphical, object-oriented interface capable of capturing the influence of complex system input variability on probabilistic system outcomes. A GoldSim stochastic fate and transport model for 235-F was developed and matched with a PORFLOW deterministic model to simulate probabilistic release and flow of radionuclides from ABL and PuFF into the vadose zone, the Upper Three Runs (UTR) Aquifer, and UTR Creek. The GoldSim model was used to probabilistically evaluate four ISD scenarios against USEPA groundwater radiation MCLs and dosage standards. The deterministic 235-F GoldSim fate and transport model continues to be refined to match the results of the PORFLOW deterministic model to ensure the model accurately represents radionuclide movement through the groundwater system. The stochastic variables that are utilized within the GoldSim model are founded on the most current data; a conservative perspective is taken where needed. Alignment with the PORFLOW deterministic model, coupled with input stochastic variability, allows the probabilistic 235-F GoldSim model to capture the conservative breadth of possible outcomes for radionuclide fate within this particular system. This ensures that the USEPA MCLs and dosage limits hold even in the worst case scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scalable standard optical sources in the VUV: Emissions from electron impact on metals

The use of electron impact on metals in the development of a compact optical standard lamp in the vacuum ultraviolet is described. Two different mechanisms are exploited, transition radiation and bremsstrahlung. Transition radiation will be used as a primary standard from 1200A to 3000A using 10 keV electron impact on tungsten. Bremsstrahlung will be used in the soft X-ray region below 1200A to less than 5A as an optical transfer standard from 4 keV electron impact on tantalum or tungsten.

Hughes, R.↗

Update to the Microcontroller Benchmark for Radiation Testing

LANL developed a benchmark of software code for radiation testing of microprocessors several years ago, and it was published under an open-source license on GitHub. Publishing the software is necessary for other researchers to adopt and implement this benchmark for radiation testing of other microprocessors to standardize test practices so that test data can be compared across different microprocessors. The original codes have been used several times by other organizations to test a wide range of microcontrollers and microprocessors. After several years of research, LANL is ready to update the benchmark. Changes include: 1. Addition of new codes that allow common software codes to be tested, 2. Addition of new codes that instrument more microprocessor circuitry, 3. Addition of input patterns that allow for a more compressive understanding of how the memory layout affects the sensitivity to radiation-induced faults and better use of automated test pattern generation standards, and 4. Modification of current codes for faster and more resilient detection, reporting and correction of radiation-induced faults. These codes have been tested by LANL researchers over the last few years, which has been published in the open literature. As the code base for the new benchmarks are stable, it is time to release the update to the GitHub repository, where the original codes were released.

Quinn, Heather↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localized Delivery of Cisplatin to Cervical Cancer Improves Its Therapeutic Efficacy and Minimizes Its Side Effect Profile

Cervical cancer represents the fourth most frequent malignancy in the world among women, and mortality has remained stable for the past 4 decades. Intravenous cisplatin with concurrent radiation therapy is the standard-of-care for patients with local and regional cervical cancer. However, cisplatin induces serious dose-limiting systemic toxicities and recurrence frequently occurs. In this study, we aimed to develop an intracervical drug delivery system that allows cisplatin release directly into the tumor and minimize systemic side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of Radiation Therapy and Short-Term Androgen Blockade With Abiraterone Acetate Plus Prednisone for Men With High- and Intermediate-Risk Localized Prostate Cancer

Long-term androgen-deprivation therapy (ADT) is the standard of care in combination with radiation therapy (RT) in high-risk prostate cancer (PC), despite substantial toxicity from the resulting hypogonadism. We hypothesized that a combination of more potent but shorter-term androgen inhibition in men with intermediate- or high-risk localized PC would synergize with definitive RT to provide short-term testosterone recovery and improve disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Promoting regulatory acceptance of combined ion and neutron irradiation testing of nuclear reactor materials: Modeling and software considerations

As the needs for the nuclear energy industry continue to evolve in the 21st century, timely adoption of new technological solutions acceptable to regulatory agencies is critical. Quantitative prediction of radiation damage in materials and its impact on mechanical properties is a key component of licensing and regulatory decisions regarding nuclear power plants. Accelerated testing methodologies such as combined ion and neutron irradiation data sets are crucial for the development and deployment of new materials and new manufacturing methods (e.g., additive manufacturing). However, regulatory acceptance of accelerated testing methodologies is necessary for their adoption. Further, the present work discusses the fundamental basis for comparing ion- and neutron-induced material microstructures, the theory behind interpreting radiation damage across length and time scales and radiation types, and the codes, standards, and quality assurance concerns surrounding different modeling methods and software. In particular, recommendations are given as to the path forward that will enable national laboratories, academia, and industry to develop the modeling and software basis for regulatory acceptance of the combined use of ion and neutron irradiation for material performance evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Organs at Risk Considerations for Thoracic Stereotactic Body Radiation Therapy: What Is Safe for Lung Parenchyma?

Stereotactic body radiation therapy (SBRT) has become the standard of care for inoperable early-stage non-small cell lung cancer and is often used for recurrent lung cancer and pulmonary metastases. Radiation-induced lung toxicity (RILT), including radiation pneumonitis and pulmonary fibrosis, is a major concern for which it is important to understand dosimetric and clinical predictors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Radiation Detector

Direct photon detector responds to microwave frequencies. Method based on trapped-ion frequency-generation standards proposed to detect radio-frequency (RF) radiation at 40.5 GHz. Technique used for directdetection (RF) communication, radar, and radio astronomy.

Lesh, J. R.↗

Evaluation of Trapped Radiation Model Uncertainties for Spacecraft Design

The standard AP8 and AE8 models for predicting trapped proton and electron environments have been compared with several sets of flight data to evaluate model uncertainties. Model comparisons are made with flux, dose, and activation measurements made on various U.S. low-Earth orbit satellites (APEX, CRRES, DMSP. LDEF, NOAA) and Space Shuttle flights, on Russian satellites (Photon-8, Cosmos-1887, Cosmos-2044), and on the Russian Mir space station. This report gives a summary of the model-data given in a companion report. Results from the model comparisons with flight data show, for example, that the AP8 model underpredicts the trapped proton flux at low altitudes by a factor of about two (independent of proton energy and solar cycle conditions), and that the AE8 model overpredict the flux in the outer electron belt be an order of magnitude or more.

Armstrong, T. W.↗

Evaluation of Trapped Radiation Model Uncertainties for Spacecraft Design

The standard AP8 and AE8 models for predicting trapped proton and electron environments have been compared with several sets of flight data to evaluate model uncertainties. Model comparisons are made with flux, dose, and activation measurements made on various U.S. low-Earth orbit satellites (APEX, CRRES, DMSP, LDEF, NOAA) and Space Shuttle flights, on Russian satellites (Photon-8, Cosmos-1887, Cosmos-2044), and on the Russian Mir Space Station. This report gives a summary of the model-data comparisons-detailed results are given in a companion report. Results from the model comparisons with flic,ht data show, for example, the AP8 model underpredicts the trapped proton flux at low altitudes by a factor of about two (independent of proton energy and solar cycle conditions), and that the AE8 model overpredicts the flux in the outer electron belt by an order of magnitude or more.

Armstrong, T. W.↗

Updating the Jovian Proton Radiation Environment - 2015

Since publication in 1983 by N. Divine and H. Garrett, the Jet Propulsion Laboratory's plasma and radiation models have been the design standard for NASA's missions to Jupiter. These models consist of representations of the cold plasma and electrons, the warm and auroral electrons and protons, and the radiation environment (electron, proton, and heavy ions). To date, however, the high-energy proton model has been limited to an L-shell of 12. With the requirement to compute the effects of the high energy protons and other heavy ions on the proposed Europa mission, the extension of the high energy proton model from approximately 12 L-shell to approximately 50 L-shell has become necessary. In particular, a model of the proton environment over that range is required to estimate radiation effects on the solar arrays for the mission. This study describes both the steps taken to extend the original Divine proton model out to an approximately 50 L-shell and the resulting model developed to accomplish that goal. In addition to hydrogen, the oxygen, sulfur, and helium heavy ion environments have also been added between approximately 6 L-shell and approximately 50 L-shell. Finally, selected examples of the model's predictions are presented to illustrate the uses of the tool.

Garrett, Henry↗