Search NASA⌕ Search

SEARCH · Search NASA

Results for “Range expansion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spectral line profiles of nickel and argon in supernova 1987A - Expansion velocity and electron scattering effects

Spectra of SN 1987A showing the Ni II 6.634-micron and Ar II 6.983-micron fine-structure lines were obtained from the Kuiper Airborne Observatory in April 1988. The signal-to-noise ratio of 100 near the peaks and resolving power of 200 are sufficient to show the average velocity of expansion from the core of about 1400 km/s and to indicate the range of velocities. An asymmetry in the profiles of both lines and a redshift of the line centroids of about 440 km/s above the 280-km/s recessional velocity of the LMC can be explained in terms of scattering of the photons by electrons in the expanding hydrogen envelope of the supernova. A mass of 0.0030 solar masses of Ni II can be deduced from the line strength of the Ni II line and a mass of 0.0009 solar masses of Ar II from the Ar II line strength.

Witteborn, F. C.↗

The millimeter- and submillimeter-wave spectrum of (C-13)H3OH revisited

A total of 245 previously unobserved millimeter- and submillimeter-wave transitions of (C-13)H3OH for J not above 10 were assigned on the basis of measurements with a spectrometer which uses 40-60 GHz klystrons as fundamental radiation sources. These transitions were combined with the previously assigned 596 transitions and were analyzed using a modified internal-axis-method model which treats the symmetric (A) and degenerate (E) substates separately. As a result of the expansion of the (C-13)H3OH data set to cover the same range as the data set of a previous (C-12)H3OH analysis by Anderson et al. (1990), rigid criteria of self-consistency could be applied for the selection and the value of the constants between the isotopic species. The spectral constants obtained were used to make accurate predictions of 562 additional transitions of (C-13)H3OH for v(t) = 0, 1, 2 and rotational quantum number J equal to or less than 12.

Anderson, Todd↗

A hardened CARS system utilized for temperature measurements in a supersonic combustor

A coherent anti-Stokes Raman scattering (CARS) system has been hardened for utilization in a NASA Langley supersonic combustion test cell that can obtain temperature cross sections of the flow at three locations. This system is remotely operated and environmentally protected. Measurements were obtained in a scramjet combustor model consisting of a rearward-facing step, followed by an expansion duct. The freestream conditions were Mach 2, with static pressure that ranged from 0.8 to 1.9 atm, and a static temperature of about 800 K. Data for two different flow conditions were obtained that provided a comparison between reacting and nonreacting mixing of injected hydrogen fuel with the combustion-heated supersonic stream.

Antcliff, Richard R.↗

Faraday anomalous dispersion optical tuners

Common methods for frequency stabilizing diode lasers systems employ gratings, etalons, optical electric double feedback, atomic resonance, and a Faraday cell with low magnetic field. Our method, the Faraday Anomalous Dispersion Optical Transmitter (FADOT) laser locking, is much simpler than other schemes. The FADOT uses commercial laser diodes with no antireflection coatings, an atomic Faraday cell with a single polarizer, and an output coupler to form a compound cavity. This method is vibration insensitive, thermal expansion effects are minimal, and the system has a frequency pull in range of 443.2 GHz (9A). Our technique is based on the Faraday anomalous dispersion optical filter. This method has potential applications in optical communication, remote sensing, and pumping laser excited optical filters. We present the first theoretical model for the FADOT and compare the calculations to our experimental results.

Wanninger, P.↗

Thrust and drag characteristics of a convergent-divergent nozzle with various exhaust jet temperatures

An investigation was conducted in the 8-by-6 foot supersonic wind tunnel on the effect of exhaust-gas temperatures on the external and internal characteristics of a convergent-divergent nozzle having an area expansion ratio of 1.83. Data were obtained over a pressure-ratio range from 1 to 20 at free-stream Mach numbers of 1.6 and 2.0 for exhaust temperatures of 860 degrees, 1650 degrees, and 2000 degrees R. Results of this investigation indicated that generally both the internal and external performance characteristics were only slightly affected by a large change in jet temperature. The small differences in performance which did occur were predicted satisfactorily from theoretical considerations.

Hearth, Donald P↗

Carbon-carbon grid for ion engines

A method and apparatus of manufacturing a grid member for use in an ion discharge apparatus provides a woven carbon fiber in a matrix of carbon. The carbon fibers are orientated to provide a negatibe coefficient of thermal expansion for at least a portion of the grid member's operative range of use.

Garner, Charles E.↗

Carbon-carbon grid for ion engines

A method and apparatus of manufacturing a grid member for use in an ion discharge apparatus provides a woven carbon fiber in a matrix of carbon. The carbon fibers are orientated to provide a negatibe coefficient of thermal expansion for at least a portion of the grid member's operative range of use.

Garner, Charles E.↗

Flow Testing of Corrugated Metal Flexhoses to Evaluate Flow-Induced Vibration and Stiffness

Corrugated metal flexhoses are used to supply fluid routing where straight rigid pipes cannot meet the design requirements due to vibrations, thermal expansion, or motion. These types of hoses are found in a wide range of applications at KSC (Exploration Ground Systems Program in particular) with various fluid commodities such as fuel, oxidizers, coolant, and cryogenics. However, flexibility of design comes at a price: due to increased levels of turbulence generated by the hose geometry, the necessary supply pressure must increase to achieve the same flow rate. Furthermore, the convolutes of the flexhoses interact with the flow field to generate areas of flow separation which leads to a phenomenon known as vortex shedding. When the frequency of vortex shedding couples with the natural frequency of the hose, this can be detrimental and cause premature failure. There are a limited amount of software that can correctly model the coupled fluid structure interactions(FSI) between the solid and fluid physics. This project aims to develop a computer model that can predict Flow-Induced Vibration (FIV) on flexhoses in one of the atypical configurations found in the State-of-the-Art (SOTA) standard for hoses in an angulated state. Our research seeks to extend the literature and expand NASA’s FIV standard. The computational rigor and resources available in the Apollo Era did not allow for flow coupling between fluids and structure interfaces to evaluate FIV of the flexhose. Our team believes that modern techniques and methods of evaluation should be used to reevaluate and extend the database of FIV and stiffness properties of flexhoses to assess the risk of failure. The core performance criteria is a computer model that is able to predict the FIV frequency within 10%.

Jared F. Congiardo↗

Development and Testing of a Lab-Scale Electrochemical Refrigerator

Eta Space and NASA have been developing a lab-scale electrochemical hydrogen refrigerator (ECHR) capable of providing isothermal heat exchange for applications in the 20-Kelvin range. The cryocooler utilizes an electrochemical compressor paired with Joule-Thomson expansion to cool the hydrogen working fluid down to its saturation point within a purpose-built cold box. The use of electrochemical compression allows the cycle to operate with no moving parts presenting several key advantages for a variety of applications. Testing of the integrated system occurred in Eta Space’s cryogenic test facility where the system was able to achieve and maintain saturated temperatures at low pressure. Results of this test campaign demonstrate the feasibility of the ECHR concept in practice.

D J Hollibaugh↗

Harmonic and Anharmonic Properties of Diamond Structure Crystals with Application to the Calculation of the Thermal Expansion of Silicon

Silicon has interesting harmonic and anharmonic properties such as the low lying transverse acoustic modes at the X and L points of the Brillouin zone, negative Gruneisen parameters, negative thermal expansion and anomalous acoustic attenuation. In an attempt to understand these properties, a lattice dynamical model employing long range, nonlocal, dipole-dipole interactions was developed. Analytic expression for the Gruneisen parameters of several modes are presented. These expressions explain how the negative Gruneisen parameters arise. This model is applied to the calculation of the thermal expansion of silicon from 5K to 1700K. The thermoelastic contribution to the acoustic attenuation of silicon is computed from 1 to 300 K. Strong attenuation anomalies associated with negative thermal expansion are found in the vicinity of 17K and 125K.

Wanser, K. H.↗

A laser interferometer dilatometer for thermal expansion measurements of composites

A high precision Fizeau type, laser interferometer dilatometer system has been developed for low expansion composite materials. The strain resolution is about 1 microstrain. The system is automated to operate over a large temperature range and record data during the test in real time. A technique has been developed to reduce the fringe data in real time to length changes. The dilatometer system is described and thermal expansion measurements for several fiber-reinforced and particle filled composites are presented.

Tompkins, S. S.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

A Noncontact Measurement Technique for the Density and Thermal Expansion Coefficient of Solid and Liquid Materials

A noncontact measurement technique for the density and the thermal expansion refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator (HTESL) at the Jet Propulsion Laboratory in which 2-3 mm diameter samples can be levitated, melted, and radiatively cooled in a vacuum. Due to the axisymmetric nature of the molten samples when levitated in the HTESL, a rather simple digital image analysis can be employed to accurately measure the volumetric change as a function of temperature. Density and the thermal expansion coefficient measurements were made on a pure nickel sample to test the accuracy of the technique in the temperature range of 1045-1565 C. The result for the liquid phase density can be expressed by p = 8.848 + (6.730 x 10(exp -4)) x T (degC) g/cu cm within 0.8% accuracy, and the corresponding thermal expansion coefficient can be expressed by Beta=(9.419 x 10(exp -5)) - (7.165 x 10(exp -9) x T (degC)/K within 0.2% accuracy.

Chung, Sang K.↗

Baroreflex-mediated heart rate and vascular resistance responses 24 h after maximal exercise

INTRODUCTION: Plasma volume, heart rate (HR) variability, and stimulus-response relationships for baroreflex control of forearm vascular resistance (FVR) and HR were studied in eight healthy men after and without performing a bout of maximal exercise to test the hypotheses that acute expansion of plasma volume is associated with 1) reduction in baroreflex-mediated HR response, and 2) altered operational range for central venous pressure (CVP). METHODS: The relationship between stimulus (DeltaCVP) and vasoconstrictive reflex response (DeltaFVR) during unloading of cardiopulmonary baroreceptors was assessed with lower-body negative pressure (LBNP, 0, -5, -10, -15, -20 mm Hg). The relationship between stimulus (Deltamean arterial pressure (MAP)) and cardiac reflex response (DeltaHR) during loading of arterial baroreceptors was assessed with steady-state infusion of phenylephrine (PE) designed to increase MAP by 15 mm Hg alone and during application of LBNP (PE+LBNP) and neck pressure (PE+LBNP+NP). Measurements of vascular volume and autonomic baroreflex responses were conducted on two different test days, each separated by at least 1 wk. On one day, baroreflex response was tested 24 h after graded cycle exercise to volitional exhaustion. On another day, measurement of baroreflex response was repeated with no exercise (control). The order of exercise and control treatments was counterbalanced. RESULTS: Baseline CVP was elevated (P = 0.04) from a control value of 10.5 +/- 0.4 to 12.3 +/- 0.4 mm Hg 24 h after exercise. Average DeltaFVR/DeltaCVP during LBNP was not different (P = 0.942) between the exercise (-1.35 +/- 0.32 pru x mm Hg-1) and control (-1.32 +/- 0.36 pru x mm Hg-1) conditions. However, maximal exercise caused a shift along the reflex response relationship to a higher CVP and lower FVR. HR baroreflex response (DeltaHR/DeltaMAP) to PE+LBNP+NP was lower (P = 0.015) after maximal exercise (-0.43 +/- 0.15 beats x min-1 x mm Hg-1) compared with the control condition (-0.83 +/- 0.14 beats x min-1 x mm Hg-1). CONCLUSION: Expansion of vascular volume after acute exercise is associated with altered operational range for CVP and reduced HR response to arterial baroreceptor stimulation.

Non-NASA Center↗

Shock shapes of blunt bodies in hypersonic helium, air, and CO2 flows

A primary factor governing hypersonic flowfield characteristics of blunt vehicles entering planetary atmospheres is the normal shock density ratio. Hence, a means of duplicating or simulating the high density ratios experienced during planetary entry is needed. One facility having the capability of generating a range of hypersonic-hypervelocity flow conditions in arbitrary test gases is the expansion tube. Preliminary shock shape results obtained in the Langley 6-in. expansion tube at hypersonic conditions are presented. Normal shock density ratios from approximately 4 to 19 were generated using helium, air, and CO2 test gases at freestream velocities from 5 to 7 km/sec. Test models were a flat-faced cylinder and the Viking aeroshell.

Miller, C. G.↗

A reduced volumetric expansion factor plot

A reduced volumetric expansion factor plot was constructed for simple fluids which is suitable for engineering computations in heat transfer. Volumetric expansion factors were found useful in correlating heat transfer data over a wide range of operating conditions including liquids, gases and the near critical region.

Hendricks, R. C.↗

Synthesis of Al-26 in explosive hydrogen burning

The possibility of Al-26 synthesis during the explosive processing of hydrogen-rich material in the outer layers of a supernova or in nova envelopes is investigated. It is found that in the peak temperature range of 1-3 x 10 to the 8th deg K and for expansion time scales of the order of 1-1000 s, values of (Al-26)/(Al-27) as high as 0.1-1 can be obtained for values of 0.001-100,000 for the product of the peak density in g/cu cm and the proton mass fraction. Such a level of Al-26 production is considerably higher than that of recent carbon/neon burning nucleosynthesis models, and is sufficient to account for the magnesium anomalies detected in certain inclusions from the Leoville and Allende meteorites. Al abundances resulting from a hydrodynamical calculation performed on the grounds of a 25 solar mass presupernova model are also presented, and the influence of uncertainties in the input physics is discussed; in particular, the rates of the (Mg-25)(p,gamma)(Al-26) and (Al-26)(p,gamma)(Si-27) key reactions are studied.

Arnould, M.↗

Performance of a 2D-CD nonaxisymmetric exhaust nozzle on a turbojet engine at altitude

Baseline thrust and cooling data obtained with a 2D-CD versatile research exhaust nozzle mounted on a turbojet engine in an altitude chamber are presented. The tests covered a range of nozzle pressure ratios, nozzle pressure ratios, nozzle throat areas, and internal expansion area ratios. The thrust data obtained show good agreement with theory and scale model results after correcting the data for leakage and bypass cooling flows. Additional work is needed to improve predictability of cooling performance.

Straight, D. M.↗