Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

HEAO A-2 soft X-ray source catalog

The HEAO A-2 low energy X-ray detectors have surveyed over 95% of the sky in the spectral bands 0.18-0.44 and 0.44-2.8 keV, down to a typical limiting sensitivity of 1 x 10 to the -11th and 3 x 10 to the -11th ergs per sq cm per sec in each band, respectively. Using a significance criterion of 6 sigma for existence, 114 sources are cataloged, of which 54 were previously undiscovered and 32 remain unidentified. The catalog contains a listing of all counterpart identifications and a cross-reference to all HEAO 1 A-2 low energy detector team publications on the catalog sources complete through the end of 1981. Supplementary material allows the estimation of spectral parameters for the spectral models from the observed intensities. Simple graphs allow the extraction of energy fluxes at the earth, both with and without the effects of interstellar absorption. The angular distribution of the cataloged sources in the 0.44-2.8 keV band is concentrated toward the galactic plane and resembles that seen at higher energy. The distribution in the 0.18-0.44 keV band is more uniform and contains many more newly discovered and unidentified sources.

Nugent, J. J.↗

Journal of Gravitational Physiology, Volume 12, Number 1

The following topics were covered: System Specificity in Responsiveness to Intermittent -Gx Gravitation during Simulated Microgravity in Rats; A Brief Overview of Animal Hypergravity Studies; Neurovestibular Adaptation to Short Radius Centrifugation; Effect of Artificial Gravity with Exercise Load by Using Short-Arm Centrifuge with Bicycle Ergometer as a Countermeasure Against Disused Osteoporosis; Perception of Body Vertical in Microgravity during Parabolic Flight; Virtual Environment a Behavioral and Countermeasure Tool for Assisted Gesture in Weightlessness: Experiments during Parabolic Flight; Artificial Gravity: Physiological Perspectives for Long-Term Space Exploration; Comparison of the Effects of DL-threo-Beta-Benzyloxyaspartate on the Glutamate Release from Synaptosomes before and after Exposure of Rats to Artificial Gravity; Do Perception and Postrotatory Vestibulo-Ocular Reflex Share the Same Gravity Reference?; Vestibular Adaptation to Changing Gravity Levels and the Orientation of Listing's Plane; Compound Mechanism Hypothesis on +Gz - Induced Brain Injury and Dysfunction of Learning and Memory; Environmental Challenge Impairs Prefrontal Brain Functions; Effect of 6-Days of Support Withdrawal on Characteristics of Balance Function; Hypergravity-Induced Changes of Neuronal Activities in CA1 Region of Rat Hippocampus; Audiological Findings in Antiorthostatic Position Modelling Microgravitation; Investigating Human Cognitive Performance during Spaceflight; The Relevance of the Minimization of Torque Exchange with the Environment in Weightlessness is Confirmed by Asimulation Study; Characteristics of the Eyes Pursuit Function during Readaptation to Terrestrial Gravity after Prolonged Flights Aboard the International Space Station; Comparison of Cognitive Performance Tests for Promethazine Pharmacodynamics in Human Subjects; Structural Reappraisal of Dendritic Tree of Cerebellar Purkinje Cell for Novel Functional Modeling of Elementary Sensorimotor Adaptive Processes; Orpheus 0 G or Ear in Microgravity to Establish Symptoms Concomittant of Inner and Middle Ear and Osteoporosis in Microgravity; Understanding Visual Perception in the Perspective of Gravity; Cortical Regions Associated with Orthostatic Stress in Conscious Humans; Restoration of Central Blood Volume: Application of a Simple Concept and Simple Device to Counteract Cardiovascular Instability in Syncope and Hemorrhage; WISE-2005: Integrative Cardiovascular Responses with LBNP during 60-Day Bed Rest in Women; Intracranial Pressure Increases during Weightlessness. A Parabolic Flights Study; Lower Limb & Portal Veins Echography for Predicting Risk of Thrombosis during a 90-D Bed Rest; Calf Tissue Liquid Stowage and Muscular and Deep Vein Distension in Orthostatic Tests after a 90-Day Head Down Bed Rest; Morphology of Brain Vessels in the Tail Suspended Rats Exposed to Intermittent 2 G; Alterations in Vasoreactivity of Femoral Artery Induced by Hindlimb Unweighting are Related to the Changes of Contractile Protein in Rats; and Respiratory Sinus Arrhythmia: A Marker of Decreased Parasympathetic Modulation after Short Duration.

Fuller, Charles A.↗

Mean sea surface and geoid gradient comparisons with TOPEX altimeter data

Cycles 4 to 54 of TOPEX data have been analyzed through comparisons with the mean sea surface given on the disturbed geophysical data record (GDR). Two inverted barometer correction procedures were considered for the data reduction. One used a constant atmospheric pressure for all data while the one adopted for use, for most computations, introduced a cycle average pressure. The maximum difference between the two estimates was 3.0 cm with a clear annual signal. With the modified correction the TOPEX sea surface was compared to The Ohio State University (OSU) mean sea surface, given on the GDR, to estimate three translations ( delta x = -2.3 cm; delta y = 25.0 cm; delta z = -0.3 cm) and a bias (43.3 cm) between the two surfaces. The only significant translation is delta y which indicates the reference frame of the TOPEX system differs from that used in the OSU mean sea surface system. The bias between the TOPEX mean sea surface and the OSU mean sea surface was used to estimate an equatorial radius of 6,378,136.55 m based on an 18-cm biased estimate of the TOPEX altimeter. Examination of the average difference, by cycle, between the TOPEX sea surface and the OSU mean sea surface suggested a bias change of 3.1 +/- 2.2 mm/yr with a positive sign indicating the average ocean surface is rising or the altimeter measured distance is decreasing. Models were implemented that solved directly for a bias, bias rate annual/semiannual, and tide correction terms. The computations indicated that a simultaneous solution for this bias, bias rate, and annual/semiannual terms gave the most accurate results. Nonsimultaneous solutions led to slightly different bias rate values. The root mean square difference between the TOPEX sea surface and OSU sea surface, after translation and bias correction, was +/- 17 cm for a typical cycle. Some locations were indentified where the difference could reach 2.3 cm and were repeated over several cycles indicating errors in the mean sea surface. Most of the large differences occur in regions lacking altimeter data prior to the TOPEX/POSEIDON mission and/or areas of significant bathymetric signature. Geoid gradients are needed for the reduction of individual track data to a reference track. The accuracy of the determination of such gradients was determined through the comparison of predicted along-track gradients to the observed gradients. Among four mean sea surfaces tested the best agreement was found with the OSU mean sea surface placed on the TOPEX geophysical data record.

Rapp, Richard H.↗

Longitudinal Assessments of Quality of Life in Endometrial Cancer Patients: Effect of Surgical Approach and Adjuvant Radiotherapy

Purpose: Adjuvant radiotherapy (RT) is often considered for endometrial cancer. We studied the effect of RT and surgical treatment on patients' quality of life (QOL). Methods and Materials: All patients referred to the gynecologic oncology clinics with biopsy findings showing endometrial cancer were recruited. QOL assessments were performed using the European Organization for Research and Treatment of Cancer QOL questionnaire-C30, version 3. Assessments were obtained at study entry and at regular 3-month intervals for a maximum of 2 years. Open-ended telephone interviews were done every 6 months. Linear mixed regression models were built using QOL domain scores as dependent variables, with the predictors of surgical treatment and adjuvant RT type. Results: A total of 40 patients were recruited; 80% of the surgeries were performed by laparotomy. Significant improvements were seen in most QOL domains with increased time from treatment. Adjuvant RT resulted in significantly more severe bowel symptoms and improvement in insomnia compared with conservative follow-up. No significant adverse effect from adjuvant RT was seen on the overall QOL. Bowel symptoms were significantly increased in patients treated with laparotomy compared with laparoscopy in the patients treated with whole pelvic RT. Qualitatively, about one-half of the patients noted improvements in their overall QOL during follow-up, with easy fatigability the most prevalent. Conclusion: No significant adverse effect was seen on patients' overall QOL with adjuvant pelvic RT after the recovery period. The acute adverse effects on patients' QOL significantly improved with an increasing interval from diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated UF 6 Cylinder Enrichment Assay: Status of the Hybrid Enrichment Verification Array (HEVA) Project: POTAS Phase II

Pacific Northwest National Laboratory (PNNL) intends to automate the UF 6 cylinder nondestructive assay (NDA) verification currently performed by the International Atomic Energy Agency (IAEA) at enrichment plants. PNNL is proposing the installation of a portal monitor at a key measurement point to positively identify each cylinder, measure its mass and enrichment, store the data along with operator inputs in a secure database, and maintain continuity of knowledge on measured cylinders until inspector arrival. This report summarizes the status of the research and development of an enrichment assay methodology supporting the cylinder verification concept. The enrichment assay approach exploits a hybrid of two passively-detected ionizing-radiation signatures: the traditional enrichment meter signature (186-keV photon peak area) and a non-traditional signature, manifested in the high-energy (3 to 8 MeV) gamma-ray continuum, generated by neutron emission from UF 6 . PNNL has designed, fabricated, and field-tested several prototype assay sensor packages in an effort to demonstrate proof-of-principle for the hybrid assay approach, quantify the expected assay precision for various categories of cylinder contents, and assess the potential for unsupervised deployment of the technology in a portal-monitor form factor. We refer to recent sensor-package prototypes as the Hybrid Enrichment Verification Array (HEVA). The report provides an overview of the assay signatures and summarizes the results of several HEVA field measurement campaigns on populations of Type 30B UF 6 cylinders containing low-enriched uranium (LEU), natural uranium (NU), and depleted uranium (DU). Approaches to performance optimization of the assay technique via radiation transport modeling are briefly described, as are spectroscopic and data-analysis algorithms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isomer-resolved unimolecular dynamics of the hydroperoxyalkyl intermediate (•QOOH) in cyclohexane oxidation

The oxidation of cycloalkanes is important in the combustion of transportation fuels and in atmospheric secondary organic aerosol formation. A transient carbon-centered radical intermediate (•QOOH) in the oxidation of cyclohexane is identified through its infrared fingerprint and time- and energy-resolved unimolecular dissociation dynamics to hydroxyl (OH) radical and bicyclic ether products. Although the cyclohexyl ring structure leads to three nearly degenerate •QOOH isomers (β-, γ-, and δ-QOOH), their transition state (TS) barriers to OH products are predicted to differ considerably. Selective characterization of the β-QOOH isomer is achieved at excitation energies associated with the lowest TS barrier, resulting in rapid unimolecular decay to OH products that are detected. A benchmarking approach is employed for the calculation of high-accuracy stationary point energies, in particular TS barriers, for cyclohexane oxidation (C 6 H 11 O 2 ), building on higher-level reference calculations for the smaller ethane oxidation (C 2 H 5 O 2 ) system. The isomer-specific characterization of β-QOOH is validated by comparison of experimental OH product appearance rates with computed statistical microcanonical rates, including significant heavy-atom tunneling, at energies in the vicinity of the TS barrier. Master-equation modeling is utilized to extend the results to thermal unimolecular decay rate constants at temperatures and pressures relevant to cyclohexane combustion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Collection for Current U.S. Wind Energy Projects: Component Costs, Financing, Operations, and Maintenance (January 2011 - September 2011)

DNV Renewables (USA) Inc. (DNV) used an Operations and Maintenance (O&M) Cost Model to evaluate ten distinct cost scenarios encountered under variations in wind turbine component failure rates. The analysis considers 1) a Reference Scenario using the default part failure rates within the O&M Cost Model, 2) High Failure Rate Scenarios that increase the failure rates of three major components(blades, gearboxes, and generators) individually, 3) 100% Replacement Scenarios that model full replacement of these components over a 20 year operating life, and 4) Serial Failure Scenarios that model full replacement of blades, gearboxes, and generators in years 4 to 6 of the wind project. DNV selected these scenarios to represent a broad range of possible operational experiences. Also in thisreport, DNV summarizes the predominant financing arrangements used to develop wind energy projects over the past several years and provides summary data on various financial metrics describing those arrangements.

17 WIND ENERGY↗

Subsonic Aerodynamic Assessment of Vortex Flow Management Devices on a High-Speed Civil Transport Configuration

An experimental investigation of the effects of leading-edge vortex management devices on the subsonic performance of a high-speed civil transport (HSCT) configuration was conducted in the Langley 14- by 22-Foot Subsonic Tunnel. Data were obtained over a Mach number range of 0.14 to 0.27, with corresponding chord Reynolds numbers of 3.08 x 10 (sup 6) to 5.47 x 10 (sup 6). The test model was designed for a cruise Mach number of 2.7. During the subsonic high-lift phase of flight, vortical flow dominates the upper surface flow structure, and during vortex breakdown, this flow causes adverse pitch-up and a reduction of usable lift. The experimental results showed that the beneficial effects of small leading-edge vortex management devices located near the model reference center were insufficient to substantially affect the resulting aerodynamic forces and moments. However, devices located at or near the wiring apex region demonstrated potential for pitch control with little effect on overall lift.

Campbell, Bryan A.↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Observations of Cygnus X-2 with IUE - Ultraviolet results from a multiwavelength campaign

IUE observations of Cyg X-2 obtained during June and October 1988 are reported and analyzed, with reference to data from simultaneous X-ray and radio observations and the predictions of theoretical models. The results are presented in extensive tables and graphs and characterized in detail. The UV flux is shown to increase monotonically as the X-ray emission moves along the Z-shaped trajectory from the horizontal to the flaring branch and the estimated mass accretion rate increases from about 6 x 10 to the -9th to 1.6 x 10 to the -8th solar mass/yr. Model calculations indicate that X-ray illumination of the accretion disk accounts for at least 80 percent of the observed UV emission, with 20 percent or less from the X-ray-heated surface of the companion star and less than 1 percent from the cool surface.

Vrtilek, S. D.↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

Aerodynamic Performance and Flow-Field Characteristics of Two Waverider-Derived Hypersonic Cruise Configurations

The component integration of a class of hypersonic high-lift configurations known as waveriders into hypersonic cruise vehicles was evaluated. A wind-tunnel model was developed which integrates realistic vehicle components with two waverider shapes, referred to as the straight-wing and cranked-wing shapes. Both shapes were conical-flow-derived waveriders for a design Mach number of 4.0. Experimental data and limited computational fluid dynamics (CFD) predictions were obtained over a Mach number range of 1.6 to 4.63 at a Reynolds number of 2.0 x 10(exp 6) per foot. The CFD predictions and flow visualization data confirmed the shock attachment characteristics of the baseline waverider shapes and illustrated the waverider flow-field properties. Experimental data showed that no significant performance degradations, in terms of maximum lift-to-drag ratios, occur at off-design Mach numbers for the waverider shapes and the integrated configurations. A comparison of the fully-integrated waverider vehicles to the baseline shapes showed that the performance was significantly degraded when all of the components were added to the waveriders, with the most significant degradation resulting from aftbody closure and the addition of control surfaces. Both fully-integrated configurations were longitudinally unstable over the Mach number range studied with the selected center of gravity location and for unpowered conditions. The cranked-wing configuration provided better lateral-directional stability characteristics than the straight-wing configuration.

Cockrell, Charles E., Jr.↗

Performance Testing of a Liquid Metal Pump for In-Space Power Systems

Fission surface power (FSP) systems could be used to provide power on the surface of the moon, Mars, or other planets and moons of our solar system. Fission power systems could provide excellent performance at any location, including those near the poles or other permanently shaded regions, and offer the capability to provide on demand power at any time, even at large distances from the sun. Fission-based systems also offer the potential for outposts, crew and science instruments to operate in a power-rich environment. NASA has been exploring technologies with the goal of reducing the cost and technical risk of employing FSP systems. A reference 40 kWe option has been devised that is cost-competitive with alternatives while providing more power for less mass anywhere on the lunar surface. The reference FSP system is also readily extensible for use on Mars, where it would be capable of operating through global dust storms and providing year-round power at any Martian latitude. Detailed development of the FSP concept and the reference mission are documented in various other reports. The development discussed in this paper prepares the way for testing of the Technology Demonstration Unit (TDU), which is a 10 kWe end-to-end test of FSP technologies intended to raise the entire FSP system to technology readiness level (TRL) 6. The Early Flight Fission Test Facility (EFF-TF) was established by NASA s Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a nonnuclear test methodology. This includes fabrication and testing at both the module/component level and at near prototypic reactor components and configurations allowing for realistic thermal-hydraulic evaluations of systems. The liquid-metal pump associated with the FSP system must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National Laboratory (INL) was tasked with the modeling, design, and fabrication of an ALIP suitable for the FSP reference mission. A prototypic ALIP was fabricated under the direction of INL and shipped to MSFC for inclusion in the Technology Demonstration Unit (TDU), a quarter-scale end-to-end reactor simulator system that is scheduled for testing at NASA-GRC. Before inclusion in the TDU, the ALIP was tested in the ALIP test circuit (ATC), which is a rig developed and operated at MSFC for the specific purpose of providing accurate quantification of liquid metal pump performance. Data showing the pump performance curves (pressure, flowrate, and pump efficiency) are presented for various operating power levels, demonstrating the full performance envelope of the pump.

Polzin, Kurt↗

Measurement of the $\Upsilon$(1S) pair production cross section and search for resonances decaying to $\Upsilon$(1S)$\mu^+\mu^-$ in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The fiducial cross section for Y(1S) pair production in proton-proton collisions at a center-of-mass energy of 13 TeV in the region where both Y(1S) mesons have an absolute rapidity below 2.0 is measured to be 79±11(stat)±6(syst)±3(B) pb assuming the mesons are produced unpolarized. The last uncertainty corresponds to the uncertainty in the Y(1S) meson dimuon branching fraction. The measurement is performed in the final state with four muons using proton-proton collision data collected in 2016 by the CMS experiment at the LHC, corresponding to an integrated luminosity of 35.9 fb−1 . This process serves as a standard model reference in a search for narrow resonances decaying to Y(1S)μ+μ− in the same final state. Such a resonance could indicate the existence of a tetraquark that is a bound state of two b quarks and two b¯ antiquarks. The tetraquark search is performed for masses in the vicinity of four times the bottom quark mass, between 17.5 and 19.5 GeV, while a generic search for other resonances is performed for masses between 16.5 and 27 GeV. No significant excess of events compatible with a narrow resonance is observed in the data. Limits on the production cross section times branching fraction to four muons via an intermediate Y(1S) resonance are set as a function of the resonance mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TOTAL SOLAR ECLIPSE OBSERVATIONS OF HOT PROMINENCE SHROUDS

Using observations of the corona taken during the total solar eclipses of 2006 March 29 and 2008 August 1 in broadband white light and in narrow bandpass filters centered at Fe X 637.4 nm, Fe XI 789.2 nm, Fe XIII 1074.7 nm, and Fe XIV 530.3 nm, we show that prominences observed off the solar limb are enshrouded in hot plasmas within twisted magnetic structures. These shrouds, which are commonly referred to as cavities in the literature, are clearly distinct from the overlying arch-like structures that form the base of streamers. The existence of these hot shrouds had been predicted by model studies dating back to the early 1970s, with more recent studies implying their association with twisted magnetic flux ropes. The eclipse observations presented here, which cover a temperature range of 0.9 to 2 x10{sup 6} K, are the first to resolve the long-standing ambiguity associated with the temperature and magnetic structure of prominence cavities.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for three-dimensional projective and tomographic imaging radar networks

Results of a study demonstrating the feasibility of broadband and speckle-free projective imaging of a complex shaped scattering object in the 6-17 GHz range with centimeter resolution are presented. It is shown how angular, spectral, and polarization diversities can be combined in the data acquisition process with a unique target-derived reference technique to access the three-dimensional Fourier space of the scatterer cost-effectively. Imagea retrieval algorithms, based on the projection slice theorem and knowledge of object symmetry, are utilized in obtaining images of a model aircraft with near optical resolution. The implications for high-resolution three-dimensional tomographic imaging radar networks are discussed.

Farhat, N. H.↗

SU-E-T-05: A 2D EPID Transit Dosimetry Model Based On An Empirical Quadratic Formalism

Purpose: To describe a 2D electronic portal imaging device (EPID) transit dosimetry model, based on an empirical quadratic formalism, that can predict either EPID or in-phantom dose distribution for comparisons with EPID captured image or treatment planning system (TPS) dose respectively. Methods: A quadratic equation can be used to relate the reduction in intensity of an exit beam to the equivalent path length of the attenuator. The calibration involved deriving coefficients from a set of dose planes measured for homogeneous phantoms with known thicknesses under reference conditions. In this study, calibration dose planes were measured with EPID and ionisation chamber (IC) in water for the same reference beam (6MV, 100mu, 20×20cm{sup 2}) and set of thicknesses (0–30cm). Since the same calibration conditions were used, the EPID and IC measurements can be related through the quadratic equation. Consequently, EPID transit dose can be predicted from TPS exported dose planes and in-phantom dose can be predicted using EPID distribution captured during treatment as an input. The model was tested with 4 open fields, 6 wedge fields, and 7 IMRT fields on homogeneous and heterogeneous phantoms. Comparisons were done using 2D absolute gamma (3%/3mm) and results were validated against measurements with a commercial 2D array device. Results: The gamma pass rates for comparisons between EPID measured and predicted ranged from 93.6% to 100.0% for all fields and phantoms tested. Results from this study agreed with 2D array measurements to within 3.1%. Meanwhile, comparisons in-phantom between TPS computed and predicted ranged from 91.6% to 100.0%. Validation with 2D array device was not possible for inphantom comparisons. Conclusion: A 2D EPID transit dosimetry model for treatment verification was described and proven to be accurate. The model has the advantage of being generic and allows comparisons at the EPID plane as well as multiple planes in-phantom.

60 APPLIED LIFE SCIENCES↗

Autonomous Navigation with Ground-to-Space Doppler Measurements Referenced to a Temperature-Compensated Crystal Oscillator

The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) has spent several years developing operational Onboard Navigation Systems (ONS's) to provide real-time autonomous, high-accuracy navigation products for spacecraft using NASA's space and ground communication systems. The highly successful Tracking and Data Relay Satellite System (TDRSS) ONS (TONS) experiment on the Explorer Platform/Extreme Ultraviolet Explorer (EP/EUVE) spacecraft, launched June 7, 1992, flight-demonstrated the ONS for high-accuracy navigation using TDRSS forward- link communications services, In late 1994, the ground station ONS (GONS) experiment, using the same EP/EUVE flight hardware, flight-demonstrated the feasibility of high-accuracy autonomous navigation using ground station forward-link communication services, with an ultrastable oscillator (USO) as the frequency reference (1 part in 10(exp 10) over 24 hours). This paper provides a follow-on analysis of GONS performance to assess the navigation accuracy achievable if GONS uses the significantly less stable (5 parts in 10(exp 8) over 24 hours, compared with a specification of 1 part in 10(exp 6)) Temperature-Compensated Crystal Oscillator (TCXO), which is integral to the transponder, as a frequency reference rather than an external USO. The GONS TCXO experiment results from a 20-day period are used to project the expected performance of an operational system. The GONS processes Doppler data derived from nominally scheduled ground station forward-link communication services using a sequential estimation algorithm enhanced by a sophisticated process noise model to provide onboard orbit and frequency determination. To evaluate the navigation accuracies achievable if a TCXO were used, actual experiment data (which used the USO as the frequency reference) were corrupted with errors from real TDRSS one-way return tracking measurements taken from EP/EUVE's TCXO. Analysis of the GONS TCXO experiment performance indicates that real-time onboard position accuracies of better than 300 meters (1 sigma) are achievable with as few as two tracking contacts per day for the EP/EUVE 525-kilometer altitude, 28.5-degree inclination orbit, provided the TCXO is as stable as that in EP/EUVE's TDRSS transponder. GONS using a TCXO frequency reference provides a viable option for many upcoming spacecraft missions with moderate position accuracy requirements and an interest in reducing their operational costs with autonomous navigation.

Radomski, M. S.↗